A study of a modified membrane filter technique for the enumeration of stressed fecal coliforms in urban runoffBrown, Edward Ryland January 1977 (has links)
Urban runoff samples collected from a parking lot in Blacksburg, Virginia were analyzed by several techniques for fecal coliform recovery. The samples were also analyzed for heavy metal concentrations.
Statistical analyses of data by the paired-t test showed that the standard membrane filter technique (MF) yielded significantly lower recoveries (0. 05 level) than the standard MPN procedure. A modified membrane filter technique employing a two-layer agar and a two hour 35°C preincubation period (M-2hr) was found to yield recoveries consistently greater (0.01 level) than the standard MF technique. Increasing the preincubation period to five hours in this modified method (M-5hr) resulted in recoveries that were even greater (0.005 level). The recoveries of the M-5hr method were found to closely approximate the MPN recoveries in most cases.
It was concluded that a substantial percentage of the fecal coliform population found in urban runoff may be injured by a host of environmental factors, though no correlations could be made with metal concentrations or elapsed time between rainfalls. The M-5hr method was concluded to be quite useful in the recovery of these stressed organisms. though growth of non-fecal-coliforms was increased and made enumeration of the fecal coliforms more difficult. / Master of Science
|