• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 8
  • 8
  • 5
  • 5
  • 4
  • 4
  • 4
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Comparação entre métodos de inspeção não-destrutiva aplicados a peças compósitas laminadas sólidas estruturais aeronáuticas / Comparing nondestructive inspection methods applied to aeronautical grade solid structural composite laminated parts

Marcos Miranda 27 June 2011 (has links)
Diversos métodos de ensaios não-destrutivos (Ultrasom, Radiografia, Termografia e Shearografia) foram empregados na inspeção de peças laminadas estruturais compósitas sólidas de matriz polimérica manufaturadas pela indústria aeronáutica. Concluiu-se que Ultrasom pulso-eco convencional de contato foi a técnica mais abrangente na indicação de descontinuidades (danos/defeitos de manufatura) considerando-se peças planas e curvas, não obstante tenha falhado na detecção de trincas longas e bem definidas localizada na alma de componentes co-curados. Radiografia convencional por filmes exibiu um potencial interessante como método alternativo, ou complementar ao de Ultrasom. Termografia infravermelha foi a técnica mais veloz na indicação de descontinuidades, sendo uma valiosa alternativa para um mapeamento rápido em inspeções preliminares seguidas pela aplicação de técnicas complementares. Shearografia realizada com equipamento da empresa Photonita detectou inclusões em peça plana compósita, porém a interpretação dos resultados obtidos em geometrias mais complexas se mostrou duvidosa. O uso de equipamento shearográfico da empresa Dantec indicou posições em regiões curvas que podem estar associadas à presença de defeitos/danos locais, porém uma confirmação cabal desta relação não foi efetivada. Evidências visuais da profusa presença de danos/defeitos de manufatura, além da existência de detalhes construtivos nas peças compósitas mais complexas, sugerem que estas descontinuidades podem ter sensibilizado, em maior ou menor extensão, os equipamentos END, juntamente com a eventual presença de delaminações/falhas de adesão nas respectivas peças avaliadas. / Several nondestructive methods (Ultrasonics, Radiography, Thermography and Shearography) were employed for inspection of structural polymer matrix composite laminated parts manufactured by aircraft industry. Is has been concluded that conventional pulse-echo contact Ultrasonics was the most comprehensive technique to indicate discontinuities (manufacture damages/defects) in flat and curved parts, although it has failed to detect long and well-defined cracks in co-cured components. Conventional film radiography exhibited good potential as alternative or complementary method to Ultrasonics. Infrared thermography was the fastest technique to indicate discontinuities, so that it is a valuable option for rapid mapping in preliminary inspection followed by the application of complementary techniques. Sherography by means of Photonita equipment detected inclusions in flat panels, but the interpretation of results from pieces with more complex geometries was dubious. A shearographic of the Dantec device indicated positions in curved regions which might possibly be associated to the presence of damages/defects, however this relationship could not be definitively established. Visual evidences of the profuse existence of manufacture damages/defects, besides constructive details in more complex composite parts, suggest that theses discontinuities might have affected to some extent the NDT equipments, along with the eventual presence of delaminations/lack of adhesion on the respective evaluated parts.
12

Tenacidade à fratura translaminar dinâmica de um laminado híbrido metal-fibra titânio-grafite de grau aeronáutico / Dynamic translaminar fracture toughness of aeronautical grade titanium-graphite hybrid fiber-metal laminate

Gatti, Maria Cristina Adami 09 October 2009 (has links)
Diversos critérios de tenacidade à fratura translaminar dinâmica foram determinados para o laminado híbrido metal-fibra TiGra, empregando-se conceitos e metodologias da Mecânica da Fratura Elástica Linear MFEL (fator-K) e da Mecânica da Fratura Elasto-Plástica MFEP (integral-J). Verificou-se que as tenacidades de iniciação elasto-plástica, Jid, e de carga máxima, Jmd, do TiGra são controladas pelo desenvolvimento, ou supressão de delaminações. Os resultados indicaram que o emprego deste material se justifica mais pela sua resistência à propagação de danos (caracterizada por Jmd) do que à iniciação da fratura dinâmica (por Jid). De modo geral, os requisitos de validade de Jid como verdadeira propriedade do material (JId) foram satisfeitos, embora para Jmd boa parte das restrições quanto ao tamanho mínimo do corpo-de-prova tenha sido violada. Mais freqüentemente, velocidades mais rápidas de impacto beneficiaram as tenacidades-J do TiGra, enquanto que temperaturas mais elevadas afetaram negativamente estas propriedades. Quanto à MFEL, a tenacidade KJd do TiGra foi beneficiada pelo incremento na taxa de carregamento sob temperaturas mais elevadas, enquanto que a tenacidade Kid foi negativamente afetada pela taxa de deformação em todas as temperaturas avaliadas. Temperaturas mais altas também degradaram as propriedades de tenacidade-K do TiGra. Em oposição às tenacidades-J, os critérios KJd e Kid não satisfizeram em absoluto os mais exigentes critérios de contenção de plasticidade estabelecidos pela MFEL, se comparados aos propostos pela MFEP. Por fim, o desempenho mecânico do laminado TiGra foi severamente comprometido quando do cômputo da densidade específica para a determinação das tenacidades J e K por unidade de massa, sendo nesta ocasião o laminado híbrido facilmente superado por vários laminados convencionais da classe dos Carbono-Epóxi. / Several dynamic translaminar fracture toughness criteria have been determined for TiGr hybrid fiber-metal laminate through Linear Elastic (K-factor) and Elastic-Plastic (J-integral) Fracture Mechanics (LEFM and EPFM, respectively) concepts and methodologies. Instrumented Charpy impact testing was carried out over a wide range of temperatures under two loading rates. It has been discovered that the elastic-plastic initiation toughness, Jid, and the toughness at maximum load, Jmd, of TiGr are controlled by either delamination favoring or suppression. Impact tests revealed that the in-service use of TiGr must rely on its resistance to dynamic fracture propagation (as characterized by Jmd) rather than on fracture initiation (by Jid). In a broad sense, the requirements for Jid data validity as a material property (JId) were fulfilled, whereas many restrictive demands in regard to the minimum testpiece size were violated by the Jmd criterion. Generally, higher impact velocities were beneficial to TiGrs J-toughnesses, inasmuch as higher temperatures impaired these properties. Regarding the LEFM approach, KJd toughness of TiGr laminate was imparted by faster impacts at higher temperatures, whilst the strain rate negatively influenced the Kid toughness over the whole temperature range tested. Higher temperatures also degraded the K-toughness properties of TiGr hybrid laminate. Differently from J-toughnesses values, the KJd e Kid criteria did not satisfy at all the more stringent criteria set forth by the LEFM approach with regard to plastic constraint, as compared to those established by EPFM. Finally, the mechanical performance of TiGr laminate was overwhelmingly compromised as the materials specific gravity was taken in account to obtain K and J toughness values by unit weight, so that TiGr was by far exceeded in this regard by conventional Carbon/Epoxy composite laminates.
13

Tenacidade à fratura translaminar dinâmica de um laminado híbrido metal-fibra titânio-grafite de grau aeronáutico / Dynamic translaminar fracture toughness of aeronautical grade titanium-graphite hybrid fiber-metal laminate

Maria Cristina Adami Gatti 09 October 2009 (has links)
Diversos critérios de tenacidade à fratura translaminar dinâmica foram determinados para o laminado híbrido metal-fibra TiGra, empregando-se conceitos e metodologias da Mecânica da Fratura Elástica Linear MFEL (fator-K) e da Mecânica da Fratura Elasto-Plástica MFEP (integral-J). Verificou-se que as tenacidades de iniciação elasto-plástica, Jid, e de carga máxima, Jmd, do TiGra são controladas pelo desenvolvimento, ou supressão de delaminações. Os resultados indicaram que o emprego deste material se justifica mais pela sua resistência à propagação de danos (caracterizada por Jmd) do que à iniciação da fratura dinâmica (por Jid). De modo geral, os requisitos de validade de Jid como verdadeira propriedade do material (JId) foram satisfeitos, embora para Jmd boa parte das restrições quanto ao tamanho mínimo do corpo-de-prova tenha sido violada. Mais freqüentemente, velocidades mais rápidas de impacto beneficiaram as tenacidades-J do TiGra, enquanto que temperaturas mais elevadas afetaram negativamente estas propriedades. Quanto à MFEL, a tenacidade KJd do TiGra foi beneficiada pelo incremento na taxa de carregamento sob temperaturas mais elevadas, enquanto que a tenacidade Kid foi negativamente afetada pela taxa de deformação em todas as temperaturas avaliadas. Temperaturas mais altas também degradaram as propriedades de tenacidade-K do TiGra. Em oposição às tenacidades-J, os critérios KJd e Kid não satisfizeram em absoluto os mais exigentes critérios de contenção de plasticidade estabelecidos pela MFEL, se comparados aos propostos pela MFEP. Por fim, o desempenho mecânico do laminado TiGra foi severamente comprometido quando do cômputo da densidade específica para a determinação das tenacidades J e K por unidade de massa, sendo nesta ocasião o laminado híbrido facilmente superado por vários laminados convencionais da classe dos Carbono-Epóxi. / Several dynamic translaminar fracture toughness criteria have been determined for TiGr hybrid fiber-metal laminate through Linear Elastic (K-factor) and Elastic-Plastic (J-integral) Fracture Mechanics (LEFM and EPFM, respectively) concepts and methodologies. Instrumented Charpy impact testing was carried out over a wide range of temperatures under two loading rates. It has been discovered that the elastic-plastic initiation toughness, Jid, and the toughness at maximum load, Jmd, of TiGr are controlled by either delamination favoring or suppression. Impact tests revealed that the in-service use of TiGr must rely on its resistance to dynamic fracture propagation (as characterized by Jmd) rather than on fracture initiation (by Jid). In a broad sense, the requirements for Jid data validity as a material property (JId) were fulfilled, whereas many restrictive demands in regard to the minimum testpiece size were violated by the Jmd criterion. Generally, higher impact velocities were beneficial to TiGrs J-toughnesses, inasmuch as higher temperatures impaired these properties. Regarding the LEFM approach, KJd toughness of TiGr laminate was imparted by faster impacts at higher temperatures, whilst the strain rate negatively influenced the Kid toughness over the whole temperature range tested. Higher temperatures also degraded the K-toughness properties of TiGr hybrid laminate. Differently from J-toughnesses values, the KJd e Kid criteria did not satisfy at all the more stringent criteria set forth by the LEFM approach with regard to plastic constraint, as compared to those established by EPFM. Finally, the mechanical performance of TiGr laminate was overwhelmingly compromised as the materials specific gravity was taken in account to obtain K and J toughness values by unit weight, so that TiGr was by far exceeded in this regard by conventional Carbon/Epoxy composite laminates.

Page generated in 0.08 seconds