• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 28
  • 1
  • Tagged with
  • 29
  • 29
  • 23
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Sistema de laser de diodo de cavidade estendida para padrões de frequência / Extended cavity diode laser system for primary frequency standards

De Martin Junior, Jair 10 May 2013 (has links)
Este trabalho tem como objetivo principal desenvolver uma nova fonte de laser de diodo compacta e robusta, além de um novo drive de controle para serem utilizados em padrões primário de tempo e frequência tipo chafariz de átomo de Césio e padrões compacto baseados em átomos frios. Um dos requisitos para utilização de laser de diodo em padrões primários de tempo e frequência é sua estabilidade em frequência e baixíssimo ruído espectral. Além disto, dada à aplicação embarcada, o laser deve ser extremamente robusto com relação às condições adversas: mecânicas, térmicas e elétricas. Tanto a parte optomecânica, quanto os controles eletrônicos do novo laser foram desenvolvidos neste trabalho. Vale salientar que tal sistema, em sua concepção, é de grande interesse para diversos outros tipos de aplicação, como espectroscopia de gases (LIDAR), referências em outras frequências e experimentos de física atômica e molecular, que possuem elevados níveis de exigência com relação a ruídos espectrais. / This work has as main objective to develop a new source of diode laser compact and robust, beyond a new drive control for use in primary of time and frequency standards type cesium atom fountain and compact standards-based cold atoms. One of the requirements for the use of diode laser in primary of time and frequency standards are their stability in frequency and are very low spectral noise. Furthermore, given the embedded application, the laser must be extremely robust with respect to adverse conditions: mechanical, thermal and electrical. Both opto-mechanical part, as the electronic controls of the new laser were developed in this work. It is noteworthy that such a system, in its conception, is of great interest to many other types of applications such as spectroscopy of gases (LIDAR), references in other frequencies and experiments of atomic and molecular physics, which have high levels of demand with respect to spectral noise.
2

Efeito da terapia fotodinâmica antimicrobiana na viabilidade e virulência dos Streptococcus mutans / Effect of methylene blue induced photodynamic therapy on biofilm viability and virulence factors of Streptococcus mutans

Nemezio, Mariana Alencar 27 April 2016 (has links)
O objetivo do presente estudo foi avaliar o efeito da Terapia Fotodinâmica Antimicrobiana (aPDT) com a utilização de azul de metileno a 0,01%, combinado ao laser de diodo, na viabilidade e na produção de polissacarídeos, de biofilmes de S. mutans. Biofilmes de cepas de S. mutans UA159 foram cultivados em discos de resina acrílica e expostos oito vezes por dia, durante 1 min, à solução de sacarose a 10%. Após 48 horas da formação do biofilme, as amostras foram distribuídas aleatoriamente em relação aos tratamentos (n=4): aplicação de solução salina a 0,9% (controle negativo), aplicação de 0,12% de digluconato de clorexidina (controle positivo), ou aplicação da terapia fotodinâmica antimicrobiana. Para aplicação da terapia fotodinâmica antimicrobiana, foi utilizado azul de metileno a 0,01%, combinado ao laser de diodo com comprimento de onda de 660 nm. Foram usados os seguintes parâmetros: área da secção transversal do feixe de laser 0,028 cm&sup2;, potência de 100 mW, energia de 9J, densidade de energia de 320J/cm&sup2;, durante 90s. Os tratamentos foram realizados duas vezes ao dia. Após 120 h, os biofilmes de S. mutans formados sobre cada disco de resina acrílica foram coletados, de modo a determinar o número de bactérias viáveis e a concentração do polissacarídeo extracelular insolúvel (PECI) e do polissacarídeo intracelular (PIC). A análise variância um critério (ANOVA) e o teste de Tukey revelaram que as contagens das bactérias nos biofilmes formados foram significativamente diferentes entre os tratamentos. A aPDT mostrou inibição do crescimento do biofilme, quando comparado ao grupo do NaCl (p<0,05). A concentração de PECI e PIC foi maior no biofilme exposto ao NaCl do que a encontrada nos outros grupos (p<0,05) e não foi observada diferença significativa entre os grupos digluconato de clorexidina e aPDT (p>0,05). De acordo com as condições experimentais do presente estudo, sugere-se que o tratamento realizado duas vezes ao dia com aPDT utilizando-se azul de metileno a 0,01%, combinado ao laser de diodo (&lambda; = 660 nm; 320 J/cm&sup2;; 100 mW; 90s; 9J), diminui a viabilidade do biofilme e afeta sua organização estrutural. / The aim of this study was to evaluate the effect of Antimicrobial Photodynamic Therapy (aPDT) using methylene blue 0.01% combined with diode laser on biofilm viability and polysaccharides produced by Streptococcus mutans. S. mutans UA 159 biofilms were grown on acrylic resin discs and exposed eight times/day for 1 min in a 10% sucrose solution. After the biofilms were allowed to grow for 48 h, they were treated two times/day according to the treatments (n=4): 0.9% saline solution (negative control), 0.12% chlorhexidine digluconato (positive control) or Antimicrobial Photodynamic Therapy (aPDT). For the application of Antimicrobial Photodynamic Therapy has been used methylene blue 0.01% in combination with the diode laser with 660 nm wavelength. The parameters adopted were: spot size of 0.028 cm&sup2;, fixed output power of 100 mW, energy density of 320 J/cm&sup2;, time exposure of 90 s and energy of 9 J. Treatments were performed twice daily. After 120 h of growth, the biofilm formed on each disc was collected to determine the number of viable bacteria, and concentration of the insoluble exopolysaccharide (IEPS) and intracellular polysaccharide (IPS). The analysis of variance one-way (ANOVA) and Tukey test revealed that the counts of bacteria in the biofilms formed differ significantly among the treatments and aPDT showed biofilm inhibition when compared to NaCl group (p<0.05). The concentration of IEPS and IPS was higher in biofilm exposed to NaCl than that found in the other groups (p<0.05) and no significant difference was observed among CHX and aPDT groups (p>0.05). According to experimental conditions of the present work, the results suggest that a twice-daily treatment with aPDT using methylene blue 0.01% in combination with the diode laser (&lambda;=660 nm, 320 J/cm&sup2;, 100 mW, 90 s; 9J) decreases biofilm viability and affects its structural organization.
3

"Interação do laser de diodo de alta potência com a superfície radicular. Efeito na morfologia, na variação de temperatura e na adesão e proliferação de fibroblastos em cultura" / Interaction between high power diode laser and dental root surface. Thermal, morphological and biocompatibility analysis

Haypek, Patrícia 23 February 2006 (has links)
O objetivo do estudo foi analisar a interação entre o laser de diodo de alta potência e a superfície radicular através da análise de: variação de temperatura (Fase A), morfologia superficial das raízes dentárias (Fase B), adesão e a proliferação de fibroblastos cultivados sobre estas superfícies (Fase C). Vinte e um dentes unirradiculares foram utilizados nas 3 fases dos experimentos. Os grupos experimentais foram: Grupo controle - só recebeu o tratamento inicial de raspagem e alisamento radicular; Grupo INT - recebeu o mesmo tratamento do controle seguido de irradiação com o laser de diodo de alta potência, com comprimento de onda de 808 nm e fibra óptica de 400 µm de diâmetro, posicionada paralela à superfície radicular no parâmetro de 1,5 W (597,1 W/cm 2 na ponta da fibra) durante 30 s no modo interrompido; e Grupo CW - onde foi usado o mesmo tratamento do grupo INT, porém com o laser no modo contínuo. Na fase A utilizaram-se termopares para monitorar a temperatura intrapulpar; na Fase B, microscopia eletrônica de varredura (MEV) das superfícies tratadas dos 3 grupos experimentais, e na Fase C, fibroblastos foram plaqueados sobre as superfícies tratadas e em eletromicrografias de varredura as células foram contadas em 24 (adesão), 48 e 72 h (proliferação) após o plaqueamento. A monitoração de temperatura demonstrou que, com os parâmetros utilizados, houve aumento de temperatura dentro dos limites biocompatíveis e que esse aumento foi significantemente maior no grupo CW do que no grupo INT. Nos grupos irradiados observou-se presença de smear-layer modificada, exibindo uma superfície com áreas de aspecto mais liso correspondendo às áreas de fusão e ressolidificação, entremeadas por zonas de aspecto mais corrugado. Túbulos dentinários abertos não foram observados. Os fibroblastos plaqueados sobre as superfícies irradiadas aderiram e aumentaram em número no decorrer do tempo experimental. As curvas de crescimento celular sobre as superfícies irradiadas com os dois modos do laser apresentaram comportamento biológico similar entre si e com o controle. Pode-se concluir, nas condições deste estudo, que o uso do laser de diodo de alta potência é seguro do ponto de vista térmico, e causa alterações morfológicas superficiais similares, independentemente dos modos de irradiação. Adicionalmente, essas superfícies radiculares irradiadas são biocompatíveis, possibilitando a adesão e a proliferação celular / The aim of this study was to analyze the interaction between the high power diode laser and the dental root surface through the temperature variation analysis (Step A), root surface morphological observation (Step B), adhesion and proliferation of fibroblasts cultured on the top of the root surfaces (Step C). Twenty-one uniradicular teeth were used in the 3 steps of the experiments. The experimental groups were, as follows: Control group - root planning and scaling using Gracey curets; INT group - the root surfaces received the same treatment as control group followed by laser irradiation (high power diode laser, wavelength 808 nm, 400 µm optical fiber used parallel to the root surface, 1,5 W for 30 s, 597,1 W/cm 2 ), and CW - treated as the INT group however in a continuous wave. For the step A thermocouples were used; for step B, scanning electron microscopy (SEM) of the treated root surfaces of the 3 experimental groups, and at the Step C, fibroblasts were plated on the top of the root surfaces, and in scanning electronmicrographs the attached cells were counted 24 (adhesion), 48 e 72 h (proliferation) after plating. The temperature monitorization showed that, with the parameters used, there was an increase in temperature within the biological safety limits and, this increase was significantly higher for the CW group. At the root surfaces of irradiated groups a modified smear-layer was observed exhibiting rough areas intermingled to smooth areas corresponding to areas of fusion and resolidification of dental hard tissues. Open dentinal tubules were not observed. The fibroblasts plated on the top of the irradiated surfaces adhered and proliferated throughout the experimental time (0 to 3 days). The growth curves of the irradiated groups, independently of the irradiation mode, showed biological behavior similar between them and with the control group. At the conditions of this study, we concluded that the use of high power diode laser for root surface conditioning is thermically safe and causes similar superficial morphological changes independently of the irradiation mode used. Additionally, these root surfaces are biocompatible because did not impair the cell adhesion and growth
4

Desenvolvimento de sistema LIBS-LIF / Development of a LIBS-LIF system

Fragalli, André 07 November 2017 (has links)
A espectroscopia de emissão atômica de plasma induzido por laser (LIBS, do inglês Laser Induced Breakdown Spectroscopy) é uma técnica multi-elementar que tem ganhado destaque recentemente devido à sua facilidade de uso em diversas aplicações. Entretanto, o limite de detecção da técnica é alto para alguns elementos se comparada com outras técnicas (e.g. ICP). Assim, o objetivo deste trabalho é aperfeiçoar a sensibilidade de um sistema LIBS na configuração de pulso único, através da integração com a técnica de fluorescência induzida por laser (LIF). Isso é feito por meio da inserção de um laser com um comprimento de onda em uma transição ressonante do elemento cuja intensidade de emissão deseja-se ter elevada, visando a redução dos efeitos de matriz das amostras. Para este fim, foram desenvolvidos um laser de diodo contínuo de cavidade estendida e sua eletrônica de controle, almejando um sistema robusto, estável em frequência, com baixo ruído espectral e resistente a estresses mecânicos, elétricos e térmicos. Os mesmos foram integrados a um sistema LIBS para ser feita a comprovação da eficiência da técnica LIBS-LIF. / The laser-induced breakdown plasma spectroscopy (LIBS) is a multi-elemental technique that has been gainning prominence recently due to its easy usability in various applications. However, the limit of detection of this technique is high for some elements compared to other techniques (e.g. ICP). Thus, the objective of this work is to improve the sensitivity of LIBS on the single pulse configuration, through integration with the laser-induced fluorescence (LIF) technique. This is done adding a laser with a wavelength in a resonant transition of the element whose emission intensity needs to be improved, focusing on reducing the matrix effects of samples. To achieve this purpose, a continuous external cavity diode laser was developed and its control driver, aiming to create a robust system, stable in frequency, with low spectral noise and resistant to adverse mechanical, electrical and thermal stresses. Both were integrated with a LIBS system for the evaluation of the LIBS-LIF technique efficiency.
5

\"Avaliação da desinfecção da dentina radicular em profundidade provocada pela irradiação do laser de diodo de alta potência\" / Evaluation of root canal dentin desinfection in depth caused by high power diode laser irradiation.

Souza, Eliana Barbosa de 07 February 2007 (has links)
A presença de microrganismos no interior do sistema de canais radiculares é a principal causa do fracasso na terapia endodôntica. A importância da sanificação durante o preparo do canal fica clara, portanto. Dentre os microrganismos isolados nos casos de insucesso o Enterococcus faecalis é comumente encontrado. O E. faecalis é um microrganismo resistente à terapia endodôntica, à medicação intracanal de hidróxido de cálcio e sua presença contribui para o insucesso em Endodontia. A radiação laser apresenta características antimicrobianas que podem auxiliar no tratamento endodôntico. Esse estudo tem por objetivo avaliar o grau de descontaminação provocado pelo uso do laser de diodo de alta potência na dentina radicular em profundidade, após preparo químico-cirúrgico in vitro. Foram utilizadas 30 raízes de dentes unirradiculares ? esterilizadas em autoclave - que depois de inoculadas por E. faecalis cepa ATCC 29212 durante 4 semanas, foram divididas em 3 grupos: grupo 1 instrumentação rotatória - K3 (Sybron Endo, Orange, CA, EUA) com hipoclorito de sódio 0,5 % e creme Endo PTC, irrigação final com EDTA-T 17 % e posterior irradiação com laser de diodo de alta potência com comprimento de onda 830 nm na potência de 3 W por 5 s com 4 repetições segundo Gutknecht; grupo 2 instrumentação, como grupo 1, sem irradiação e grupo 3 apenas irrigação com 20 mL de solução fisiológica estéril. Os espécimes foram divididos em três terços (cervical, médio e apical), tiveram suas paredes dentinárias desgastadas por brocas Batt e as raspas, bem como o cilindro externo restante de dentina foram imersos em 1 mL de água peptonada. Assim alíquotas foram semeadas em meio seletivo mEnterococcus, em triplicata para contagem de unidades formadoras de colônias. Os resultados foram tratados estatisticamente pelo teste Kruskal-Wallis com método de comparação Dunn e apresentaram as seguintes médias: Grupo 1 ? 0, Grupo 2 ? 2,77 X 102, Grupo 3 ? 171 X 102 u.f.c./mL; com diferenças estatísticas significantes entre os 3 grupos (p<0,05). Em porcentagens, a redução da microbiota provocada pelo Grupo 1 foi de 100% e do Grupo 2 de 98,39% ambas em relação ao Grupo 3 (controle). A irradiação do laser de diodo nos parâmetros e amostras testadas foi eficaz na redução da contaminação em profundidade da dentina radicular frente ao Enterococcus faecalis. / The main cause for failure in Endodontics is the presence of microorganisms in root canal system. Enterococcus faecalis is a resistant microorganism presents in failure endodontic treatment. Therefore the disinfection plays fundamental rule in endodontic therapy. The laser irradiation presents properties that may improve the treatment success rates, reducing the microbial contamination. The aim of this study is evaluate the disinfection degree in depth caused by diode laser irradiation after chemomechanical procedures in vitro. Thirty extracted dental roots were sterilized by autoclave, inoculated by strain of Enterococcus faecalis ATCC 29212 during 4 weeks, and then randomly divided in 3 groups. Group 1: 10 specimens were instrumented by rotary files K3 (Sybron Endo, Orange, CA, USA) with 0.5 % sodium hypochlorite and urea peroxide (Endo PTC cream, Oficinalis Farmácia de Manipulação, São Paulo, SP, Brazil). At the end irrigation by 17 % EDTA-T was performed. The specimens were irradiated intracanal by diode laser 830 nm wavelength 3 W during 5 seconds, four times. Group 2: same procedures of group 1 without laser irradiation. Group 3: irrigation by saline solution. The specimens were divided in three thirds (apical, middle and cervical). Samples of dentin were obtained with carbide burs from inner canal walls of each third. The samples were immersed in 1 mL of peptonic water, and then aliquots were sowed to count viable cells in mEnterococcus agar (Difco?, Becton Drive, NJ, USA). The groups showed the following means: Group 1 ? 0, Group 2 ? 2,77 X 102 and Group 3 ? 171 X 102 CFU/mL. The disinfection degree achieved was 100 % in group 1, 98,39 % in group 2 both compared with group 3. The Kruskal-Wallis statistical analysis with Dunn method of comparison shows better results in group with diode laser irradiation (p<0.05), followed by group 2 and 3. Irradiation by diode laser in that samples and parameters achieved disinfection improvement in root dentin depth.
6

Efeito da terapia fotodinâmica antimicrobiana no controle do biofilme dental cariogênico in vitro / Effect of antimicrobial photodynamic therapy in the control of cariogenic dental biofilm in vitro

Sofia Sampaio de Sousa Farias 07 December 2015 (has links)
O objetivo deste estudo foi avaliar o efeito da terapia fotodinâmica antimicrobiana (TFDa), utilizando laser de baixa potência, em duas densidades de energia, associado ao azul de toluidina em biofilme de S. mutans. Biofilmes de S. mutans UA159 foram crescidos por 5 dias em discos de resina acrílica (3 mm de diâmetro x 2 mm de altura) a 37&ordm;C 5 % de CO2;. Os espécimes foram divididos aleatoriamente em 4 grupos de tratamento (n=3): Digluconato de clorexidina 0,12% (CHX, controle positivo); Solução salina a 0,89% (NaCl, controle negativo); Terapia fotodinâmica antimicrobiana com azul de toluidina e laser de baixa potência (densidade de energia 320 J/cm&sup2;) (TFDa 320); Terapia fotodinâmica antimicrobiana com azul de toluidina e laser de baixa potência (densidade de energia 640 J/cm&sup2;) (TFDa 640). Os tratamentos foram realizados 2x/dia durante 3 dias. Ao final dos 5 dias, os biofilmes foram coletados e número de bactérias viáveis e a concentração de polissacarídeos extracelulares insolúveis (PECI) e intracelulares (PIC) foram determinadas e analisadas estatisticamente (ANOVA e teste de Tukey, p < 0,05). O tratamento com a TFDa (320 e 640 J/cm&sup2;) reduziu o número de bactérias viáveis em biofilmes de S. mutans, de uma maneira dose-dependente (p < 0,05). Além disso, a TFDa 640 J/cm&sup2;, reduziu a viabilidade bacteriana de forma tão eficaz quanto a CHX (p > 0,05). Em relação a PECI e PIC, os grupos TFDa (320 e 640 J/cm&sup2;) não foram significativamente diferentes de CHX (p > 0,05). Os resultados mostraram que a terapia fotodinâmica antimicrobiana, mediada pelo azul de toluidina e laser de diodo (640 J/cm&sup2;), pode ser uma abordagem utilizada no controle do biofilme dental cariogênico. / The aim of this study was to evaluate the effect of antimicrobial photodynamic therapy (aPDT), using low-power laser, with two energy densities, associated with toluidine blue in S. mutans biofilm. S. mutans UA159 biofilms were grown for 5 days on acrylic resin discs (3 mm diameter x 2 mm height) a 37&ordm;C, 5 % de CO2. The specimens were randomly divided into 4 treatment groups (n = 3): 0.12% chlorhexidine digluconate (CHX, positive control); 0,89% Saline (NaCl, negative control); Antimicrobial photodynamic therapy with toluidine blue and low power laser (energy density of 320 J/cm&sup2;) (aPDT 320); Antimicrobial photodynamic therapy with toluidine blue and low power laser (energy density of 640 J/cm&sup2;) (aPDT 640). Treatments were performed 2x/day for 3 days. At the end of 5 days, the biofilms were collected and the number of viable bacteria and the concentration of insoluble extracellular (IEPS) and intracellular polysaccharides (IPS) were determined and analyzed statistically (ANOVA and Tukey\'s test, p<0.05). Treatment with aPDT (320 and 640 J/cm&sup2;) reduced the number of viable bacteria of S. mutans biofilms in a dose-dependent manner (p<0.05). Furthermore, the aPDT 640 group reduced the bacterial viability as effectively as CHX group (p>0.05). For IEPS and IPS, the aPDT groups (320 and 640 J/cm&sup2;) were not significantly different CHX (p>0.05). The results showed that the antimicrobial photodynamic therapy mediated by toluidine blue and diode laser (640 J/cm&sup2;) may be an approach used to control the cariogenic dental biofilm.
7

Avaliação morfológica ultra-estrutural e pirométrica de dentes humanos irradiados com laser de diodo 808nm

Patrocinio, Mônica Cesar do [UNESP] 24 May 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:59Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-05-24Bitstream added on 2014-06-13T21:01:50Z : No. of bitstreams: 1 patrocinio_mc_dr_sjc.pdf: 1950663 bytes, checksum: 0fd579b8b7d9d892acbde252341f7e1b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Foram analisados os efeitos do laser de diodo infravermelho sobre a morfologia ultra-estrutural dos tecidos dentários humanos e a variação da temperatura da câmara pulpar. Utilizamos 22 molares hígidos, resfriados em soro fisiológico. Anteriormente ao experimento, os dentes foram seccionados horizontalmente, separando-se coroa da raiz, a qual foi desprezada. Os espécimes experimentais foram preparados com instalação de termopar tipo J instalado na face interna da câmara pulpar e obliterados com resina, e divididos aleatoriamente em três grupos. Grupo controle: composto por dois espécimes, que não sofreram nenhum procedimento; Grupo 1: composto por dez espécimes, que tiveram a superfície de esmalte da face vestibular, irradiada com laser de diodo l 808nm, contendo laser guia de HeNe de 635nm, fibra óptica de 200mm, 7W de potência, por 2s, em modo pulsado com pulso de 0,5s e foco de 2mm. No momento da irradiação, foi aferida temperatura da câmara pulpar por meio do termopar. Grupo 2: composto por dez espécimes sendo a superfície dentinária irradiada da mesma forma que no grupo 1. Concluímos que as alterações nas superfícies, de esmalte apresentaram perda da continuidade dos prismas de esmalte, presença de material fundido com características vítreas, ressolidificação e trincas; e na dentina irradiada ocorreu fusão e ressolidificação dentinária adquirindo uma superfície vitrificada com bordas irregulares, na região central desgaste irregular atingindo diversos diâmetros e mantendo alguns túbulos abertos com compactação da camada de smear. / We analyzed the effects of diode infrared laser on ultrastrutural morphology of mineralized hard tissue on human teeth and the change temperature in pulpal chamber. We used 22 molar caries free, cooled in physiologic serum. Before the experiment, the teeth were horizontally crosscut, separation the crown by root, we never use this part. The experimental specimens were prepared with place down type J thermocouple put in internal face of pulpal chamber and obliterated with light-curing resin and random divided in three groups. Control group: compound by two specimens, in this specimens we will not doing any procedure; Group 1: compound with ten specimens, the vestibular surface of enamel was irradiated with diode laser l808nm, with guide laser HeNe 635nm, 200mm optical fiber, 7W power, for two seconds, in pulsated mode 0,5 seconds of pulse and 2mm focus. During the irradiation, the temperature of pulpal chamber was compared using type J thermocouple. In palatine or lingual surface we doing the same procedure, using other optical fiber and power (300mm and 10W); and Group 2: compound by the same number of specimens of group 1, however, the dentin surface was irradiated. We conclude the surface alteration on enamel presented prism loss continuity and presence of melt material glasslike, dentin resolidified with glasslike surface with irregular end, on the center irregular wear in several diameter and maintenance open dentin tubules with compact smear layer.
8

Efeito da terapia fotodinâmica antimicrobiana no controle do biofilme dental cariogênico in vitro / Effect of antimicrobial photodynamic therapy in the control of cariogenic dental biofilm in vitro

Farias, Sofia Sampaio de Sousa 07 December 2015 (has links)
O objetivo deste estudo foi avaliar o efeito da terapia fotodinâmica antimicrobiana (TFDa), utilizando laser de baixa potência, em duas densidades de energia, associado ao azul de toluidina em biofilme de S. mutans. Biofilmes de S. mutans UA159 foram crescidos por 5 dias em discos de resina acrílica (3 mm de diâmetro x 2 mm de altura) a 37&ordm;C 5 % de CO2;. Os espécimes foram divididos aleatoriamente em 4 grupos de tratamento (n=3): Digluconato de clorexidina 0,12% (CHX, controle positivo); Solução salina a 0,89% (NaCl, controle negativo); Terapia fotodinâmica antimicrobiana com azul de toluidina e laser de baixa potência (densidade de energia 320 J/cm&sup2;) (TFDa 320); Terapia fotodinâmica antimicrobiana com azul de toluidina e laser de baixa potência (densidade de energia 640 J/cm&sup2;) (TFDa 640). Os tratamentos foram realizados 2x/dia durante 3 dias. Ao final dos 5 dias, os biofilmes foram coletados e número de bactérias viáveis e a concentração de polissacarídeos extracelulares insolúveis (PECI) e intracelulares (PIC) foram determinadas e analisadas estatisticamente (ANOVA e teste de Tukey, p < 0,05). O tratamento com a TFDa (320 e 640 J/cm&sup2;) reduziu o número de bactérias viáveis em biofilmes de S. mutans, de uma maneira dose-dependente (p < 0,05). Além disso, a TFDa 640 J/cm&sup2;, reduziu a viabilidade bacteriana de forma tão eficaz quanto a CHX (p > 0,05). Em relação a PECI e PIC, os grupos TFDa (320 e 640 J/cm&sup2;) não foram significativamente diferentes de CHX (p > 0,05). Os resultados mostraram que a terapia fotodinâmica antimicrobiana, mediada pelo azul de toluidina e laser de diodo (640 J/cm&sup2;), pode ser uma abordagem utilizada no controle do biofilme dental cariogênico. / The aim of this study was to evaluate the effect of antimicrobial photodynamic therapy (aPDT), using low-power laser, with two energy densities, associated with toluidine blue in S. mutans biofilm. S. mutans UA159 biofilms were grown for 5 days on acrylic resin discs (3 mm diameter x 2 mm height) a 37&ordm;C, 5 % de CO2. The specimens were randomly divided into 4 treatment groups (n = 3): 0.12% chlorhexidine digluconate (CHX, positive control); 0,89% Saline (NaCl, negative control); Antimicrobial photodynamic therapy with toluidine blue and low power laser (energy density of 320 J/cm&sup2;) (aPDT 320); Antimicrobial photodynamic therapy with toluidine blue and low power laser (energy density of 640 J/cm&sup2;) (aPDT 640). Treatments were performed 2x/day for 3 days. At the end of 5 days, the biofilms were collected and the number of viable bacteria and the concentration of insoluble extracellular (IEPS) and intracellular polysaccharides (IPS) were determined and analyzed statistically (ANOVA and Tukey\'s test, p<0.05). Treatment with aPDT (320 and 640 J/cm&sup2;) reduced the number of viable bacteria of S. mutans biofilms in a dose-dependent manner (p<0.05). Furthermore, the aPDT 640 group reduced the bacterial viability as effectively as CHX group (p>0.05). For IEPS and IPS, the aPDT groups (320 and 640 J/cm&sup2;) were not significantly different CHX (p>0.05). The results showed that the antimicrobial photodynamic therapy mediated by toluidine blue and diode laser (640 J/cm&sup2;) may be an approach used to control the cariogenic dental biofilm.
9

\"Avaliação da desinfecção da dentina radicular em profundidade provocada pela irradiação do laser de diodo de alta potência\" / Evaluation of root canal dentin desinfection in depth caused by high power diode laser irradiation.

Eliana Barbosa de Souza 07 February 2007 (has links)
A presença de microrganismos no interior do sistema de canais radiculares é a principal causa do fracasso na terapia endodôntica. A importância da sanificação durante o preparo do canal fica clara, portanto. Dentre os microrganismos isolados nos casos de insucesso o Enterococcus faecalis é comumente encontrado. O E. faecalis é um microrganismo resistente à terapia endodôntica, à medicação intracanal de hidróxido de cálcio e sua presença contribui para o insucesso em Endodontia. A radiação laser apresenta características antimicrobianas que podem auxiliar no tratamento endodôntico. Esse estudo tem por objetivo avaliar o grau de descontaminação provocado pelo uso do laser de diodo de alta potência na dentina radicular em profundidade, após preparo químico-cirúrgico in vitro. Foram utilizadas 30 raízes de dentes unirradiculares ? esterilizadas em autoclave - que depois de inoculadas por E. faecalis cepa ATCC 29212 durante 4 semanas, foram divididas em 3 grupos: grupo 1 instrumentação rotatória - K3 (Sybron Endo, Orange, CA, EUA) com hipoclorito de sódio 0,5 % e creme Endo PTC, irrigação final com EDTA-T 17 % e posterior irradiação com laser de diodo de alta potência com comprimento de onda 830 nm na potência de 3 W por 5 s com 4 repetições segundo Gutknecht; grupo 2 instrumentação, como grupo 1, sem irradiação e grupo 3 apenas irrigação com 20 mL de solução fisiológica estéril. Os espécimes foram divididos em três terços (cervical, médio e apical), tiveram suas paredes dentinárias desgastadas por brocas Batt e as raspas, bem como o cilindro externo restante de dentina foram imersos em 1 mL de água peptonada. Assim alíquotas foram semeadas em meio seletivo mEnterococcus, em triplicata para contagem de unidades formadoras de colônias. Os resultados foram tratados estatisticamente pelo teste Kruskal-Wallis com método de comparação Dunn e apresentaram as seguintes médias: Grupo 1 ? 0, Grupo 2 ? 2,77 X 102, Grupo 3 ? 171 X 102 u.f.c./mL; com diferenças estatísticas significantes entre os 3 grupos (p<0,05). Em porcentagens, a redução da microbiota provocada pelo Grupo 1 foi de 100% e do Grupo 2 de 98,39% ambas em relação ao Grupo 3 (controle). A irradiação do laser de diodo nos parâmetros e amostras testadas foi eficaz na redução da contaminação em profundidade da dentina radicular frente ao Enterococcus faecalis. / The main cause for failure in Endodontics is the presence of microorganisms in root canal system. Enterococcus faecalis is a resistant microorganism presents in failure endodontic treatment. Therefore the disinfection plays fundamental rule in endodontic therapy. The laser irradiation presents properties that may improve the treatment success rates, reducing the microbial contamination. The aim of this study is evaluate the disinfection degree in depth caused by diode laser irradiation after chemomechanical procedures in vitro. Thirty extracted dental roots were sterilized by autoclave, inoculated by strain of Enterococcus faecalis ATCC 29212 during 4 weeks, and then randomly divided in 3 groups. Group 1: 10 specimens were instrumented by rotary files K3 (Sybron Endo, Orange, CA, USA) with 0.5 % sodium hypochlorite and urea peroxide (Endo PTC cream, Oficinalis Farmácia de Manipulação, São Paulo, SP, Brazil). At the end irrigation by 17 % EDTA-T was performed. The specimens were irradiated intracanal by diode laser 830 nm wavelength 3 W during 5 seconds, four times. Group 2: same procedures of group 1 without laser irradiation. Group 3: irrigation by saline solution. The specimens were divided in three thirds (apical, middle and cervical). Samples of dentin were obtained with carbide burs from inner canal walls of each third. The samples were immersed in 1 mL of peptonic water, and then aliquots were sowed to count viable cells in mEnterococcus agar (Difco?, Becton Drive, NJ, USA). The groups showed the following means: Group 1 ? 0, Group 2 ? 2,77 X 102 and Group 3 ? 171 X 102 CFU/mL. The disinfection degree achieved was 100 % in group 1, 98,39 % in group 2 both compared with group 3. The Kruskal-Wallis statistical analysis with Dunn method of comparison shows better results in group with diode laser irradiation (p<0.05), followed by group 2 and 3. Irradiation by diode laser in that samples and parameters achieved disinfection improvement in root dentin depth.
10

Desenvolvimento de sistema LIBS-LIF / Development of a LIBS-LIF system

André Fragalli 07 November 2017 (has links)
A espectroscopia de emissão atômica de plasma induzido por laser (LIBS, do inglês Laser Induced Breakdown Spectroscopy) é uma técnica multi-elementar que tem ganhado destaque recentemente devido à sua facilidade de uso em diversas aplicações. Entretanto, o limite de detecção da técnica é alto para alguns elementos se comparada com outras técnicas (e.g. ICP). Assim, o objetivo deste trabalho é aperfeiçoar a sensibilidade de um sistema LIBS na configuração de pulso único, através da integração com a técnica de fluorescência induzida por laser (LIF). Isso é feito por meio da inserção de um laser com um comprimento de onda em uma transição ressonante do elemento cuja intensidade de emissão deseja-se ter elevada, visando a redução dos efeitos de matriz das amostras. Para este fim, foram desenvolvidos um laser de diodo contínuo de cavidade estendida e sua eletrônica de controle, almejando um sistema robusto, estável em frequência, com baixo ruído espectral e resistente a estresses mecânicos, elétricos e térmicos. Os mesmos foram integrados a um sistema LIBS para ser feita a comprovação da eficiência da técnica LIBS-LIF. / The laser-induced breakdown plasma spectroscopy (LIBS) is a multi-elemental technique that has been gainning prominence recently due to its easy usability in various applications. However, the limit of detection of this technique is high for some elements compared to other techniques (e.g. ICP). Thus, the objective of this work is to improve the sensitivity of LIBS on the single pulse configuration, through integration with the laser-induced fluorescence (LIF) technique. This is done adding a laser with a wavelength in a resonant transition of the element whose emission intensity needs to be improved, focusing on reducing the matrix effects of samples. To achieve this purpose, a continuous external cavity diode laser was developed and its control driver, aiming to create a robust system, stable in frequency, with low spectral noise and resistant to adverse mechanical, electrical and thermal stresses. Both were integrated with a LIBS system for the evaluation of the LIBS-LIF technique efficiency.

Page generated in 0.445 seconds