Spelling suggestions: "subject:"denses."" "subject:"1enses.""
111 |
Probing small-scale structure in galaxies with strong gravitational lensingCongdon, Arthur Benjamin. January 2008 (has links)
Thesis (Ph. D.)--Rutgers University, 2008. / "Graduate Program in Physics and Astronomy." Includes bibliographical references.
|
112 |
Quasar-galaxy correlations and the detection of magnification bias /Norman, Dara J. January 1999 (has links)
Thesis (Ph. D.)--University of Washington, 1999. / Vita. Includes bibliographical references (p. 125-129).
|
113 |
Negative Point Mass Singularities in General RelativityRobbins, Nicholas P. January 2007 (has links)
Thesis (Ph. D.)--Duke University, 2007. / Includes bibliographical references.
|
114 |
The Extragalactic Lens VLBI Imaging Survey (ELVIS) investigating galaxy cores and black holes with gravitational lens central images /Boyce, Edward R. January 2006 (has links) (PDF)
Thesis (Ph. D.)--Massachusets Institute of Technology (MIT), 2006. / PDF copy of thesis. Includes bibliograpy.
|
115 |
The effects of positive and negative lenses on the accommodative-convergence/accommodation ratioGillan, W.D.H. 11 February 2014 (has links)
M.Phil. (Optometry) / The accommodative-convergence accommodation (AC/A) ratio is a commonly used relationship in the practice of optometry. Many practitioners make use of the AC/A ratio as an aid to diagnostic and prognostic decisions. It is not perfectly clear what effects positive and negative lenses have on the AC/A ratio. A number of questions remain relating to linearity, symptomatology and equality of lens effects on the AC/A ratio. This experiment was designed and conducted in an attempt to answer some of these unanswered questions and forms the foundation of this thesis. A literature review of available knowledge related to this study is detailed. An instrument is described which was constructed to measure the necessary accommodation and vergence changes induced by various stimuli. A sample of first year students at the Rand Afrikaans University department of Optometry was selected according to various acceptance criteria. A total of 109 students were screened , of which a group of 26 students was subjected to the experimental investigation. The data were then subjected to a statistical analysis in an attempt to reveal correlations, linearity and group formations.
|
116 |
The effect of tinted lenses on colour discrimination and contrast sensitivityRamkissoon, Prithipaul 27 October 2008 (has links)
M. Phil. / Please refer to full text to view abstract / Prof. J.T. Ferreira
|
117 |
Visual and non-visual variables implicated in monovision wearDu Toit, Renee 10 June 2014 (has links)
M.Phil. (Optometry) / Please refer to full text to view abstract
|
118 |
Electrical-static discharge in single point diamond turning machining of contact lens polymersKadermani, Mohamed Munir January 2015 (has links)
Single Point Diamond Turning (SPDT) is a technology widely applied for the fabrication of contact lenses. One of the limiting factors in polymer machining is wear of the diamond tool due to electrostatic discharge resulting in poor surface quality of the machined products. The research work presented in this dissertation highlights the electrostatic properties of contact lenses during machining operations and the effects these properties have on the surface quality of the work piece materials. Two contact lens samples were experimented on, Definitive 74 (Silicone Hydrogel) and Tyro 97 (Rigid Gas Permeable). The electrostatic surface potentials (ESPs) were measured during turning operations using an electrostatic voltmeter and the surface roughness measurements were taken using a surface profilometer. Response Surface Methodology (RSM) techniques were employed to create predictive models for both surface roughness and ESPs with respect to the cutting speed, feed rate and depth of cut. Predictive surface roughness models were successfully generated for both materials and the cutting speed and feed rate were identified as the parameters with most effect on surface roughness. In addition, an electrostatic model was successfully generated for the Definitive 74 contact lens material which cited the cutting speed and feed rate as the most effective parameters on the material’s electrostatic behaviour. However, no relationship was evident between the machining parameters and electrostatic behaviour of Tyro 97.
|
119 |
The subjective and objective effects of tinted spectacle lenses on visual performanceMoore, Linda A. 17 August 2012 (has links)
M.Phil. / Tinted spectacle lenses have long been worn to provide ocular protection from harmful electromagnetic radiation during recreational activities. Controversy exists surrounding the colour of the spectacle tints and the environmental conditions under which these tints are worn. There is little scientific evidence to substantiate the many opinions of authors on the effects of tinted spectacle lenses on visual skills and, ultimately, on overall performance in recreational situations. This study serves to provide scientific data concerning the effects of tinted lenses on static visual acuity, contrast sensitivity, colour vision, stereopsis and visual evoked potential (VEP). These results are related to the visible spectrum transmission curve for each experimental lens. recommendations are then made concerning the environmental conditions under which each lens tint should be worn. The HOYA ULT-2000 Light Transmission Metre was used to establish the percentage of visible light being transmitted through each of the experimental lenses. The DMS 80/90 Visible Spectrophotometer was used to generate a visible spectrum transmission curve for each of the 8 experimental lenses used in this study. 30 subjects (Group A) were randomly selected from the RAU student population for the assessment of the effects of tinted lenses static visual acuity, contrast sensitivity, colour vision and stereopsis. 10 students (Group B) were then randomly selected from the RAU student population for the assessment of the effects of tinted experimental lenses on visual evoked potential (VEP). The ametropic subjects in Groups A and B all wore their habitual spectacle or contact lens corrections throughout the testing procedure. The following lens tint colours were used: clear, black, grey, yellow, green, blue, red and pink. The subjects were evaluated binocularly without any tinted lens being worn, then through each of the 8 tinted experimental lenses (randomly presented). Results of the visual skills and VEP testing were analysed as follows: Group A: An average score was calculated for the results achieved on the static visual acuity, contrast sensitivity, colour vision and stereopsis tests when no experimental lenses were worn. This average was then compared to the average static visual acuity, contrast sensitivity, colour vision and stereopsis scores for each of the 8 experimental lenses. Group B: An average score was calculated for each of the amplitude and latency components of the VEP waveforms generated when no experimental lenses are worn. This average was then compared to the average amplitude and latency components generated when each of the 8 experimental lenses (as for Group A) are worn. Static visual acuity was assessed using a Snellen visual acuity letter chart at 6m. Contrast sensitivity was assessed using a Vistech VCTS 6500 Contrast Sensitivity Chart at 3m. Colour vision assessment was performed using the lshihara Colour Vision Test and the City University Colour Vision Test. The Random Dot Near Stereo Test was used to assess stereopsis. The Nicolet Pathfinder II was used to assess visual evoked potentials (VEPs). The results of this study show that the black, grey, yellow, green, blue, red and pink tinted lenses have a statistically significant influence on visual efficiency only when subjective methods (i.e. static visual acuity, contrast sensitivity, colour -vision and stereopsis) of visual efficiency assessment are used. The tinted lenses had little effect on visual efficiency when an objective means (i.e. VEP) of assessment was used, as there were no statistically significant differences between the lenses. The results of this research project indicate that the colour of the lens tint has little real effect on visual efficiency, when measured objectively. The effect of the lens tint is shown to be highly subjective. Tinted lens selection would therefore be based on personal preference and the amount of protection that the lens provides from harmful electromagnetic radiation. It can be concluded that no single lens tint is therefore suitable for all individuals under the same environmental conditions.
|
120 |
Examining Daily Disposable Soft Contact Lens Wearers' Attitudes and Beliefs (SLAB)Lutmer, Kelly M. January 2020 (has links)
No description available.
|
Page generated in 0.0503 seconds