• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Fatores de risco para lesões cervicais e câncer cervical em mulheres com diagnóstico citológico de células escamosas atípicas, Maputo-Moçambique, 2013-2015 / Risk factors for cervical lesions and cervical cancer in women with cytologic diagnosis of atypical squamous cell, Maputo-Mozambique, 2013-2015

Sitoe, Filomena Boaventura 31 July 2017 (has links)
SITOE, F. B. Fatores de risco para lesões cervicais e câncer cervical em mulheres com diagnóstico citológico de células escamosas atípicas, Maputo-Moçambique, 2013-2015. 2017. 90 f. Dissertação (Mestrado em Saúde Pública) - Faculdade de Medicina, Universidade Federal do Ceará, Fortaleza, 2017. / Submitted by Saúde Pública (msp@ufc.br) on 2017-08-22T20:14:37Z No. of bitstreams: 1 2017_dis_fbsitoe.pdf: 1769829 bytes, checksum: ec7a8a40ba4c96fdbf421e5b6d5f7b38 (MD5) / Approved for entry into archive by Erika Fernandes (erikaleitefernandes@gmail.com) on 2017-08-23T11:53:26Z (GMT) No. of bitstreams: 1 2017_dis_fbsitoe.pdf: 1769829 bytes, checksum: ec7a8a40ba4c96fdbf421e5b6d5f7b38 (MD5) / Made available in DSpace on 2017-08-23T11:53:26Z (GMT). No. of bitstreams: 1 2017_dis_fbsitoe.pdf: 1769829 bytes, checksum: ec7a8a40ba4c96fdbf421e5b6d5f7b38 (MD5) Previous issue date: 2017-07-31 / Introduction: The diagnosis and screening of cervical lesions are of paramount importance. The standard screening method for cervical cancer and its precursor lesions is cytological examination using the Papanicolaou method. Objectives: To estimate the prevalence of low and high grade cervical lesions and cervical cancer in women with cytologic diagnosis of atypical squamous cells, to verify the influence of the etiological agents of diseases with the presence of cervical lesions and cervical cancer. Method: a cross-sectional study with a quantitative approach, retrospective data collection performed at the Department of Gynecology and Obstetrics, and at the Pathology Department of the Central Hospital of Maputo, Mozambique. We studied 358 medical records from January 2013 to December 2015 of women with atypical cytologic squamous cell diagnosis. The variables p <0.05 were considered statistically significant, and the frequency of diagnoses with their respective confidence intervals (95% CI) was calculated. The presence of the lesions and the degree of association between the dependent and independent variables were verified through the Pearson correlation coefficient and prevalence ratio (PR). Results: mean age was 38.1 years, median 36.6 and standard deviation 12.3. Age ranged from 17 to 71 years. The prevalence of cervical lesions was 153 cases (63%), 50 (32.7%) for <NIC2 + and 103 (67.3%) for CIN 2+. The risk factors associated with cervical lesions and cervical cancer were: age (40-49) (P = 0.001), profession (domestic) (P = 0.016), parity (+5) (P = 0.001), menopause = 0.001), HPV (P = 0.001) and Tricomonas vaginalis (P=0,001). Conclusion: The prevalence of high-grade cervical lesions in women with atypical squamous cell cytologic diagnosis was high. The risk factors associated with the most severe cervical lesions in patients with atypical squamous cell cytology were: parity age, occupation, menopause. The etiological agents of diseases that influenced the development of cervical lesions and cervical cancer were HPV and Tricomonas vaginalis. / Introdução: O diagnóstico e o rastreamento das lesões cervicais são de suma importância. O método padrão de rastreamento do câncer do colo do útero e de suas lesões precursoras é o exame citológico pelo método de Papanicolaou. Objetivos: Estimar a prevalência das lesões cervicais de baixo e alto grau e câncer cervical em mulheres com diagnóstico citológico de células escamosas atípicas, verificar a influência dos agentes etiológicos de doenças com a presença das lesões cervicais e câncer cervical. Método: estudo transversal com abordagem quantitativa, coleta de dados retrospectiva, realizado no Departamento de ginecologia e obstetrícia, e no serviço de anatomia patológica do Hospital Central de Maputo, em Moçambique. Foram estudados 358 prontuários de janeiro de 2013 a dezembro de 2015 de mulheres com diagnóstico citológico de células escamosas atípicas. Considerou-se como estatisticamente significante as variáveis p<0,05, calculou se a frequência de diagnósticos com seus respectivos intervalos de confiança (IC95%). A presença das lesões e o grau de associação entre as variáveis dependentes e independentes foi verificada através do cálculo do coeficiente de correlação de Pearson e razão de prevalência (RP). Resultados: a média da idade foi de 38,1 anos, mediana 36,6 e o desvio padrão de 12,3. A idade variou entre 17 a 71 anos. A prevalência das lesões cervicais foi de 153 casos (63%), sendo lesão de baixo grau (NIC I) 50 (32,7%) e lesão de alto grau /carcinoma invasor (NIC 2+) 103 (67,3%). Os fatores de risco associados às lesões cervicais e câncer cervical foram: idade (40-49) (P=0,001), profissão (doméstica) (P=0,016), Paridade (+de 5) (P=0,001), menopausa (P=0,001), HPV (P=0,001), e Tricomonas vaginalis (P=0,001). Conclusão: A prevalência das lesões cervicais de alto grau em mulheres com diagnóstico citológico de células escamosas atípicas foi alta. Os fatores de risco associados às lesões cervicais mais severas em pacientes com citologia de células escamosas atípicas foram: idade paridade, profissão, menopausa. Os agentes etiológicos de doenças que influenciaram no desenvolvimento das lesões cervicais e câncer cervical foram o HPV e Tricomonas vaginalis.
2

Novo método radiográfico para a determinação de estenose do canal cervical / New method for radiografic determination of cervical stenosis

Bornholdt, Gustavo Campelo 07 October 2015 (has links)
INTRODUÇÃO: Estenose do canal cervical consiste na diminuição do diâmetro sagital do canal cervical e está associada com maior risco de lesões neurológicas decorrentes de trauma cervical. Nos esportes de colisão, a estenose do canal cervical consiste em um importante parâmetro na decisão de retorno ao esporte após neuropraxia da medula cervical e após determinadas lesões do plexo braquial. Os métodos atualmente disponíveis para avaliação de estenose do canal cervical em atletas são muito caros (ex: por ressonância nuclear magnética) ou pouco precisos (métodos radiográficos). Este estudo avaliou um novo método radiográfico para determinação de estenose do canal cervical, comparando-o com medições realizadas em cadáveres, medida por ressonância nuclear magnética do canal cervical e do espaço disponível para a medula (SAC/SACD) e com o método radiográfico consagrado na literatura para determinação de estenose do canal cervical, o índice de Torg (IT). MÉTODOS: A população do estudo foram 20 homens entre 16 e 35 anos de idade. Os sujeitos realizaram uma ressonância nuclear magnética da coluna cervical para determinação do SAC/SACD e radiografias cervicais em perfil e antero-posterior para determinação do IT e do novo método radiográfico proposto, o diâmetro corrigido do canal cervical (DCCC). Para determinar o DCCC, foi utilizada uma barra de metal de 100 mm, acoplada verticalmente na linha média cervical, utilizando os processos espinhosos das vertebras cervicais como referência. Obtidos o diâmetro sagital da imagem do canal cervical e o comprimento da imagem da barra de metal na radiografia, e conhecendo o tamanho real da barra de metal, o diâmetro real do canal medular pôde ser estimado matematicamente com o uso do teorema de Tales. Os resultados obtidos para o DCCC foram comparados com valores encontrados em estudos com cadáveres, foi avaliada a concordância entre DCCC e o diâmetro médio-sagital do canal cervical aferido por ressonância magnética (DCRM) e os métodos radiográficos (DCCC e IT) foram correlacionados com o SAC/SACD. Os cálculos foram realizados nos níveis C3 a C7, além das médias de C3 a C6 [DCCC (MDCCC), IT (MTorg) e SAC/SACD (MSAC/MSACD)]. RESULTADOS: Os valores obtidos pelo DCCC (média do MDCCC: 15.29 mm) foram compatíveis com os valores descritos em estudos de medida direta. A correlação entre DCCC e SAC/SACD foi superior à correlação entre IT e SAC/SACD, sendo de 0.7025 para MDCCC e MSACD contra 0.5473 para MTorg e MSACD. O teste de concordância entre os valores absolutos para DCCC e DCRM evidenciou valores mais elevados na medida por DCCC, sendo média de 1.84 mm maior para MDCCC em relação a média de C3 a C6 pelo DCRM. CONCLUSÕES: O Diâmetro Corrigido do Canal Cervical apresentou valores semelhantes aos encontrados em estudos com medida direta em cadáveres e apresentou correlação com SAC/SACD superior ao IT / INTRODUCTION: Cervical spinal stenosis is the diminution of the anteroposterior diameter of the spinal canal and it is associated with increased risk of neurological injury from cervical trauma. In collision sports, the cervical canal stenosis is an important parameter in the return to play decision after cervical cord neuropraxia and after some brachial plexus injuries. The methods currently available for evaluation of cervical canal stenosis in athletes are expensive (eg, nuclear magnetic resonance) or imprecise (radiographic methods). This study evaluated a new radiographic method for determination of cervical canal stenosis, comparing it to measurements performed on cadavers, measurement by magnetic resonance imaging of the cervical canal and space available for the cord (SAC/SACD) and the consecrated radiographic method for determining cervical spinal stenosis, Torg ratio(TI). METHODS: The study population were 20 men between 16 and 35 years. The subjects underwent a magnetic resonance imaging of the cervical spine to determine the SAC/SACD and cervical radiographs to determine the IT and the proposed new radiographic method, called corrected cervical canal diameter (DCCC). To determine the DCCC, a 100 mm metal bar was used vertically over the cervical midline, using the spinous processes of the cervical vertebrae as reference. Got the radiographic diameter of the medullary canal and the length of the metal bar image on the radiograph , and knowing the actual size of the metal bar , the actual diameter of the spinal canal could be estimated mathematically with the simple use of the theorem of Thales. The results for the DCCC were compared with values found in cadavers studies, the agreement between DCCC and the mid-sagittal diameter of the cervical canal measured by magnetic resonance imaging (DCRM) was calculated and radiographic methods (DCCC and IT) were correlated with SAC/SACD. Calculations were performed individually for C3 to C7 and averages of C3 to C6 [DCCC (MDCCC), IT (MTorg) and SAC/SACD (MSAC/ MSACD)]. RESULTS: The values obtained by DCCC (average MDCCC: 15:29 mm) were consistent with the values described in studies using direct measurement. The correlation between DCCC and SAC/SACD was higher than the correlation between IT and SAC/SACD, being 0.7025 for MDCCC and MSACD and 0.5473 for MTorg and MSACD. The agreement between absolute values for DCCC and DCRM showed higher values for DCCC, which average 1.84 mm greater for MDCCC compared to the average of C3 to C6 for DCRM. CONCLUSIONS: The Fixed Diameter of the Cervical Canal showed similar values to those found in studies with direct measurement from cadavers and correlated with SAC/SACD better than IT
3

Novo método radiográfico para a determinação de estenose do canal cervical / New method for radiografic determination of cervical stenosis

Gustavo Campelo Bornholdt 07 October 2015 (has links)
INTRODUÇÃO: Estenose do canal cervical consiste na diminuição do diâmetro sagital do canal cervical e está associada com maior risco de lesões neurológicas decorrentes de trauma cervical. Nos esportes de colisão, a estenose do canal cervical consiste em um importante parâmetro na decisão de retorno ao esporte após neuropraxia da medula cervical e após determinadas lesões do plexo braquial. Os métodos atualmente disponíveis para avaliação de estenose do canal cervical em atletas são muito caros (ex: por ressonância nuclear magnética) ou pouco precisos (métodos radiográficos). Este estudo avaliou um novo método radiográfico para determinação de estenose do canal cervical, comparando-o com medições realizadas em cadáveres, medida por ressonância nuclear magnética do canal cervical e do espaço disponível para a medula (SAC/SACD) e com o método radiográfico consagrado na literatura para determinação de estenose do canal cervical, o índice de Torg (IT). MÉTODOS: A população do estudo foram 20 homens entre 16 e 35 anos de idade. Os sujeitos realizaram uma ressonância nuclear magnética da coluna cervical para determinação do SAC/SACD e radiografias cervicais em perfil e antero-posterior para determinação do IT e do novo método radiográfico proposto, o diâmetro corrigido do canal cervical (DCCC). Para determinar o DCCC, foi utilizada uma barra de metal de 100 mm, acoplada verticalmente na linha média cervical, utilizando os processos espinhosos das vertebras cervicais como referência. Obtidos o diâmetro sagital da imagem do canal cervical e o comprimento da imagem da barra de metal na radiografia, e conhecendo o tamanho real da barra de metal, o diâmetro real do canal medular pôde ser estimado matematicamente com o uso do teorema de Tales. Os resultados obtidos para o DCCC foram comparados com valores encontrados em estudos com cadáveres, foi avaliada a concordância entre DCCC e o diâmetro médio-sagital do canal cervical aferido por ressonância magnética (DCRM) e os métodos radiográficos (DCCC e IT) foram correlacionados com o SAC/SACD. Os cálculos foram realizados nos níveis C3 a C7, além das médias de C3 a C6 [DCCC (MDCCC), IT (MTorg) e SAC/SACD (MSAC/MSACD)]. RESULTADOS: Os valores obtidos pelo DCCC (média do MDCCC: 15.29 mm) foram compatíveis com os valores descritos em estudos de medida direta. A correlação entre DCCC e SAC/SACD foi superior à correlação entre IT e SAC/SACD, sendo de 0.7025 para MDCCC e MSACD contra 0.5473 para MTorg e MSACD. O teste de concordância entre os valores absolutos para DCCC e DCRM evidenciou valores mais elevados na medida por DCCC, sendo média de 1.84 mm maior para MDCCC em relação a média de C3 a C6 pelo DCRM. CONCLUSÕES: O Diâmetro Corrigido do Canal Cervical apresentou valores semelhantes aos encontrados em estudos com medida direta em cadáveres e apresentou correlação com SAC/SACD superior ao IT / INTRODUCTION: Cervical spinal stenosis is the diminution of the anteroposterior diameter of the spinal canal and it is associated with increased risk of neurological injury from cervical trauma. In collision sports, the cervical canal stenosis is an important parameter in the return to play decision after cervical cord neuropraxia and after some brachial plexus injuries. The methods currently available for evaluation of cervical canal stenosis in athletes are expensive (eg, nuclear magnetic resonance) or imprecise (radiographic methods). This study evaluated a new radiographic method for determination of cervical canal stenosis, comparing it to measurements performed on cadavers, measurement by magnetic resonance imaging of the cervical canal and space available for the cord (SAC/SACD) and the consecrated radiographic method for determining cervical spinal stenosis, Torg ratio(TI). METHODS: The study population were 20 men between 16 and 35 years. The subjects underwent a magnetic resonance imaging of the cervical spine to determine the SAC/SACD and cervical radiographs to determine the IT and the proposed new radiographic method, called corrected cervical canal diameter (DCCC). To determine the DCCC, a 100 mm metal bar was used vertically over the cervical midline, using the spinous processes of the cervical vertebrae as reference. Got the radiographic diameter of the medullary canal and the length of the metal bar image on the radiograph , and knowing the actual size of the metal bar , the actual diameter of the spinal canal could be estimated mathematically with the simple use of the theorem of Thales. The results for the DCCC were compared with values found in cadavers studies, the agreement between DCCC and the mid-sagittal diameter of the cervical canal measured by magnetic resonance imaging (DCRM) was calculated and radiographic methods (DCCC and IT) were correlated with SAC/SACD. Calculations were performed individually for C3 to C7 and averages of C3 to C6 [DCCC (MDCCC), IT (MTorg) and SAC/SACD (MSAC/ MSACD)]. RESULTS: The values obtained by DCCC (average MDCCC: 15:29 mm) were consistent with the values described in studies using direct measurement. The correlation between DCCC and SAC/SACD was higher than the correlation between IT and SAC/SACD, being 0.7025 for MDCCC and MSACD and 0.5473 for MTorg and MSACD. The agreement between absolute values for DCCC and DCRM showed higher values for DCCC, which average 1.84 mm greater for MDCCC compared to the average of C3 to C6 for DCRM. CONCLUSIONS: The Fixed Diameter of the Cervical Canal showed similar values to those found in studies with direct measurement from cadavers and correlated with SAC/SACD better than IT

Page generated in 0.0687 seconds