1

Estudo sobre a incidência das porosidades e sua identificação em uma liga de alumínio A356. / Study of porosity and identification in A356 alloy.

Cardoso, Roberto 03 November 2007 (has links)
Este trabalho procurou identificar o defeito que ocorria no teste de estanqueidade de uma peça e apresentar a correlação entre o nível de porosidade encontrado no produto fundido com a liga de alumínio A356 e os processos de fusão e de manutenção sob temperaturas controladas, o teor de hidrogênio, o sistema de enchimento e de alimentação, obedecendo ao princípio de solidificação direcional e o posicionamento do modelo em relação à linha de divisão. Foram efetuadas algumas experiências com diferentes tempos de introdução de nitrogênio para a purificação do metal, com a inversão do modelo em relação ao plano de partição do molde, com a modificação das dimensões do sistema de enchimento, com a substituição dos massalotes laterais por outros com luvas exotérmicas e utilizando-se resfriadores. Tentou-se verificar os benefícios que os filtros cerâmicos proporcionam aos fundidos, principalmente quanto à diminuição do nível de porosidade, menor turbulência e maior capacidade de reter as inclusões e parte dos filmes de óxidos. Para comprová-los, propôs-se a fundição de peças, em moldes confeccionados pelo processo de areia à verde, com diferentes tipos de filtros cerâmicos nos canais de distribuição. As amostras foram analisadas no Laboratório Metalográfico do Departamento de Engenharia Metalúrgica e de Materiais da Escola Politécnica da Universidade de São Paulo e no Laboratório de Metalurgia e de Materiais Cerâmicos do Instituto de Pesquisas Tecnológicas de São Paulo. Após a análise dos resultados em microscópio óptico, microscópio eletrônico de varredura e em espectrômetro por emissão de energia observou-se que o problema está relacionado principalmente com a alimentação e a solidificação direcional e não somente com o teor de hidrogênio. / The objective of this work is to study the type of defect identified during the pressure tightness test of aluminum parts and to establish a relationship between porosity level of an A356 aluminum alloy and the production processes, hydrogen level, feeding system, and directional solidification. Different nitrogen blowing times, inversion of the mould pattern, relative to the partition line, changing of the feeding system dimensions, replacement of the lateral feeding by exothermic gloves and the use of chills where tested. Ceramic filters were also tested, in order to evaluate their influence on the formation of porosities and on the porosity level, through a decrease of turbulence and an increase in the capacity of retaining non-metallic inclusions and part of the oxide films. Casting was performed by the green sand process using different ceramic filters. The obtained parts were metallographicaly analyzed through optical and scanning electronic microscopy using also EDS analysis. The results showed that porosity is related with the feeding conditions and directional solidification besides the hydrogen content of the alloys.
2

Estudo sobre a incidência das porosidades e sua identificação em uma liga de alumínio A356. / Study of porosity and identification in A356 alloy.

Roberto Cardoso 03 November 2007 (has links)
Este trabalho procurou identificar o defeito que ocorria no teste de estanqueidade de uma peça e apresentar a correlação entre o nível de porosidade encontrado no produto fundido com a liga de alumínio A356 e os processos de fusão e de manutenção sob temperaturas controladas, o teor de hidrogênio, o sistema de enchimento e de alimentação, obedecendo ao princípio de solidificação direcional e o posicionamento do modelo em relação à linha de divisão. Foram efetuadas algumas experiências com diferentes tempos de introdução de nitrogênio para a purificação do metal, com a inversão do modelo em relação ao plano de partição do molde, com a modificação das dimensões do sistema de enchimento, com a substituição dos massalotes laterais por outros com luvas exotérmicas e utilizando-se resfriadores. Tentou-se verificar os benefícios que os filtros cerâmicos proporcionam aos fundidos, principalmente quanto à diminuição do nível de porosidade, menor turbulência e maior capacidade de reter as inclusões e parte dos filmes de óxidos. Para comprová-los, propôs-se a fundição de peças, em moldes confeccionados pelo processo de areia à verde, com diferentes tipos de filtros cerâmicos nos canais de distribuição. As amostras foram analisadas no Laboratório Metalográfico do Departamento de Engenharia Metalúrgica e de Materiais da Escola Politécnica da Universidade de São Paulo e no Laboratório de Metalurgia e de Materiais Cerâmicos do Instituto de Pesquisas Tecnológicas de São Paulo. Após a análise dos resultados em microscópio óptico, microscópio eletrônico de varredura e em espectrômetro por emissão de energia observou-se que o problema está relacionado principalmente com a alimentação e a solidificação direcional e não somente com o teor de hidrogênio. / The objective of this work is to study the type of defect identified during the pressure tightness test of aluminum parts and to establish a relationship between porosity level of an A356 aluminum alloy and the production processes, hydrogen level, feeding system, and directional solidification. Different nitrogen blowing times, inversion of the mould pattern, relative to the partition line, changing of the feeding system dimensions, replacement of the lateral feeding by exothermic gloves and the use of chills where tested. Ceramic filters were also tested, in order to evaluate their influence on the formation of porosities and on the porosity level, through a decrease of turbulence and an increase in the capacity of retaining non-metallic inclusions and part of the oxide films. Casting was performed by the green sand process using different ceramic filters. The obtained parts were metallographicaly analyzed through optical and scanning electronic microscopy using also EDS analysis. The results showed that porosity is related with the feeding conditions and directional solidification besides the hydrogen content of the alloys.
3

Comportamento da liga de alumínio A356-T6 fundida e tixoextrudada sob fadiga isotérmica e termomecânica / Casting and tixoextruded A356-T6 aluminum alloy behavior under isothermal and thermomechanical fatigue

Silva, Valdinei Ferreira da 31 August 2004 (has links)
Gradientes térmicos induzidos no interior de componentes sujeitos a variações de temperatura durante o período de funcionamento podem provocar a ocorrência de tensões e deformações internas. A repetição destes ciclos térmicos pode causar a nucleação e a propagação de trincas por um processo denominado fadiga termomecânica. Este trabalho apresenta um estudo sobre o comportamento da liga de alumínio A356-T6, processada nas condições fundida e tixoextrudada, sob fadiga isotérmica e termomecânica. Foram realizados ensaios de fadiga de baixo ciclo isotérmica para as temperaturas de 120 e 280°C, e ensaios de fadiga termomecânica em-fase e fora-de-fase para a faixa de temperatura de 120 a 280°C. O material tixoextrudado apresentou melhor desempenho em fadiga nas condições isotérmica e anisotérmica (termomecânica) devido a uma microestrutura globular com menor nível de porosidade. / Thermal gradients induced in components during service under temperature changes can cause internal stresses and strains. This cyclic thermal behavior can cause crack nucleation and propagation under a process denominated thermomechanical fatigue. Permanent mold casting and tixoextruded A356-T6 aluminum alloy behavior under isothermal and thermomechanical fatigue was study in this work. Isothermal low cycle fatigue tests were performed in temperatures of 120 and 280°C. In-phase and out-of-phase thermomechanical fatigue tests were carried out in temperature range from 120 to 280°C. The tixoextruded material presented better isothermal and thermomechanical fatigue performance due to a globular microstructure and lower porosity level.
4

Comportamento da liga de alumínio A356-T6 fundida e tixoextrudada sob fadiga isotérmica e termomecânica / Casting and tixoextruded A356-T6 aluminum alloy behavior under isothermal and thermomechanical fatigue

Valdinei Ferreira da Silva 31 August 2004 (has links)
Gradientes térmicos induzidos no interior de componentes sujeitos a variações de temperatura durante o período de funcionamento podem provocar a ocorrência de tensões e deformações internas. A repetição destes ciclos térmicos pode causar a nucleação e a propagação de trincas por um processo denominado fadiga termomecânica. Este trabalho apresenta um estudo sobre o comportamento da liga de alumínio A356-T6, processada nas condições fundida e tixoextrudada, sob fadiga isotérmica e termomecânica. Foram realizados ensaios de fadiga de baixo ciclo isotérmica para as temperaturas de 120 e 280°C, e ensaios de fadiga termomecânica em-fase e fora-de-fase para a faixa de temperatura de 120 a 280°C. O material tixoextrudado apresentou melhor desempenho em fadiga nas condições isotérmica e anisotérmica (termomecânica) devido a uma microestrutura globular com menor nível de porosidade. / Thermal gradients induced in components during service under temperature changes can cause internal stresses and strains. This cyclic thermal behavior can cause crack nucleation and propagation under a process denominated thermomechanical fatigue. Permanent mold casting and tixoextruded A356-T6 aluminum alloy behavior under isothermal and thermomechanical fatigue was study in this work. Isothermal low cycle fatigue tests were performed in temperatures of 120 and 280°C. In-phase and out-of-phase thermomechanical fatigue tests were carried out in temperature range from 120 to 280°C. The tixoextruded material presented better isothermal and thermomechanical fatigue performance due to a globular microstructure and lower porosity level.