• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Influencia de tres fontes de calor de fundição sobre a adaptação cervical de coroas totais metalicas fundidas

Milan, Fabio Machado 30 June 1997 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-22T13:48:03Z (GMT). No. of bitstreams: 1 Milan_FabioMachado_M.pdf: 4762167 bytes, checksum: 225a13cf69de4f358ca6c32469428027 (MD5) Previous issue date: 1997 / Resumo: Considerando as dificuldades técnicas existentes na confecção de restaurações fundidas, onde o mínimo desajuste cervical acarreta sérios problemas clínicos futuros, este trabalho visa a analisar o ajuste cervical de coroas totais metálicas, confeccionadas com liga à base de prata/paládio (PALLlAG - M) e paládio/prata (PORS - ON 4), com três diferentes tipos de término cervical : ombro reto, ombro biselado em 20° e chanfro em 45°, sobre troquéis torneados de aço inoxidável. Para fusão das ligas foram utilizadas três fontes de calor: acetilen%xigênio, gás/oxigênio e resistência elétrica. Após a fundição, os corposde-prova foram assentados sobre seus respectivos troquéis, sob carga estática de 9 kg. As leituras da interface troquei/coroa foram feitas em um microscópio comparador, provido de um micrômetro digital. Os resultados indicaram que a liga de Pd/Ag (PORS - ON 4) apresentou a maior média de desajuste cervical, sendo diferente estatisticamente (5%) da liga de Ag/Pd (PALLlAG - M); o método acetilen%xigênio resultou na maior média de desajuste, sendo diferente estatisticamente (5%) das fontes resistência elétrica e gás/oxigênio, ambas iguais; os ombro biselado em 20° e chanfro mostráram as maiores médias de desajuste, sendo ambos iguais estatisticamente (5%), e diferentes do ombro reto. Nessas condições estatísticas, concluiu-se que a liga de Ag/Pd (PALLlAG - M) apresentou o melhor ajuste cervical, dentro da análise das ligas utilizadas; as fontes de calor de fundição resistência elétrica e gás/oxigênio mostraram o melhor ajuste cervical, não diferindo estatisticamente (5%) entre si; e, o ombro reto obteve o melhor ajuste cervical dentro da análise dos tipos de término cervical / Abstract: Regarding the existenting difficulties in making casting restorations, where the minimal cervlcal discrepancy lead to a future serious clinical problems, this research will analyse the fit of total metal crowns, making with Ag/Pd and Pd/Ag alloys, with three different marginal configurations : shoulder, 20-degree bevel shoulder and 45-degree chanfered, on the stainless steel dies. To cast the alloys, three heat sources have been used : acetylene-oxygen, gas-oxygen and eletric resistance. After the casting, the specimens were seated on the dies, with a static load of 9 kg. The reading of the die/crown interface was made on a comparated microscope, using a digital micrometer. The results indicated that the Pd/Ag (PORS ON 4) alloy showed the highest cervical discrepancy average, has been statistical different (5%) of the Ag/Pd (PALLlAG - M) alloy; the method acetylene/oxygen resulted on a highest cervical discrepancy average, has been statistical different (5%) from the eletric resistance and gas/oxygen sources, both equal; the 20-degree bevel shoulder and 45-degree chanfer showed the highest discrepancy average, both equal statistically (5%), and different o(shoulder. In this statistical condition~, it was concluded that the Ag/Pd (PALLlAG - M) alloy showed the better cervicall fit, inside the analysis of the utilized alloys; the heat sources of casting eletric resistance and gas/oxygen, showed the better cervical fit, without statistical differences (5%) between themselves; and, the shoulder obtained the better cervlcal fit inside the nalysis of the marginal configurations / Mestrado / Materiais Dentarios / Mestre em Ciências

Page generated in 0.0723 seconds