Simulation of line fault locator on HVDC Light electrode lineHermansson, Andreas January 2010 (has links)
<p>In this bachelor thesis, cable fault locators are studied for use on the overhead electrode lines in the HVDC (High Voltage Direct Current) Light project Caprivi Link. The cable fault locators studied operates with the principle of travelling waves, where a pulse is sent in the tested conductor. The time difference is measured from the injection moment to the reflection is received. If the propagation speed of the pulse is known the distance to the fault can be calculated. This type of unit is typically referred to as a TDR (Time Domain Reflectometer). The study is performed as a computer simulation where a simplified model of a TDR unit is created and applied to an electrode line model by using PSCAD/EMTDC. Staged faults of open circuit and ground fault types are placed at three distances on the electrode line model, different parameters of the TDR units such as pulse width and pulse amplitude along with its connection to the electrode line are then studied and evaluated. The results of the simulations show that it is possible to detect faults of both open circuit and ground fault types with a suitable TDR unit. Ground faults with high resistance occurring at long distances can be hard to detect due to low reflection amplitudes from the injections. This problem can somewhat be resolved with a function that lets the user compare an old trace of a “healthy” line with the new trace. The study shows that most of the faults can be detected and a distance to the fault can be calculated within an accuracy of ± 250 m. The pulse width of the TDR needs to be at least 10 μs, preferable 20 μs to deliver high enough energy to the fault to create a detectable reflection. The pulse amplitude seams to be of less significance in this simulation, although higher pulse amplitude is likely to be more suitable in a real measurement due to the higher energy delivered to the fault. The Hipotronics TDR 1150 is a unit that fulfil these requirements and should therefore be able to work as a line fault locator on the electrode line.</p>
|
2 |
Simulation of line fault locator on HVDC Light electrode lineHermansson, Andreas January 2010 (has links)
In this bachelor thesis, cable fault locators are studied for use on the overhead electrode lines in the HVDC (High Voltage Direct Current) Light project Caprivi Link. The cable fault locators studied operates with the principle of travelling waves, where a pulse is sent in the tested conductor. The time difference is measured from the injection moment to the reflection is received. If the propagation speed of the pulse is known the distance to the fault can be calculated. This type of unit is typically referred to as a TDR (Time Domain Reflectometer). The study is performed as a computer simulation where a simplified model of a TDR unit is created and applied to an electrode line model by using PSCAD/EMTDC. Staged faults of open circuit and ground fault types are placed at three distances on the electrode line model, different parameters of the TDR units such as pulse width and pulse amplitude along with its connection to the electrode line are then studied and evaluated. The results of the simulations show that it is possible to detect faults of both open circuit and ground fault types with a suitable TDR unit. Ground faults with high resistance occurring at long distances can be hard to detect due to low reflection amplitudes from the injections. This problem can somewhat be resolved with a function that lets the user compare an old trace of a “healthy” line with the new trace. The study shows that most of the faults can be detected and a distance to the fault can be calculated within an accuracy of ± 250 m. The pulse width of the TDR needs to be at least 10 μs, preferable 20 μs to deliver high enough energy to the fault to create a detectable reflection. The pulse amplitude seams to be of less significance in this simulation, although higher pulse amplitude is likely to be more suitable in a real measurement due to the higher energy delivered to the fault. The Hipotronics TDR 1150 is a unit that fulfil these requirements and should therefore be able to work as a line fault locator on the electrode line.
|
3 |
Testování lokátoru poruch na nesymetrickém vedení / Earth fault locator testing on the model of unsymmetrical linesKohůt, Miroslav January 2016 (has links)
This master’s thesis is about earth fault locator testing on the model of unsymmetrical lines. The introductory part of thesis describes the function of the selected locator, mainly for the used calculation algorithm of fault location, options setting of fault locator and connection of the locator to the network. Master’s thesis in its practical part deals, with the setting fault locator for a particular test system on the model of the MV line and implementation of selected testing on the model unsymmetrical lines. The first part of the testing is focusing on verify the accuracy locator on an unsymmetrical line. The second test is then designed for obtaining the most accurate information on the distance of the fault, which fault locator can give. The final part is focused on verification algorithm for more accurate calculation of the fault location.
|