• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 12
  • 12
  • 12
  • 12
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Entwurf und experimentelle Untersuchung eines faseroptischen Oberflächenplasmonenresonanz-Sensors

Schuster, Tobias 13 April 2016 (has links)
In der medizinischen Diagnostik, Bioverfahrenstechnik und Umwelttechnik besteht ein steigender Bedarf an kompakten Analysegeräten für die schnelle Vor-Ort-Detektion spezifischer biochemischer Substanzen. Im Rahmen der Arbeit wurde daher ein neuartiger faseroptischer Sensor entwickelt, der in der Lage ist kleinste Brechzahländerungen, z.B. durch molekulare Bindungsprozesse, zu detektieren. Die hohe Empfindlichkeit an der vergoldeten Spitze der Sensorfaser beruht auf der Oberflächenplasmonenresonanz (SPR) einer einzelnen Mantelmode, die durch ein langperiodisches Fasergitter (LPG) ermöglicht wird. Die Übertragungsfunktion des Sensors wurde unter Verwendung eines Schichtwellenleitermodells schnell und präzise modelliert. Es konnte gezeigt werden, dass in einem wässrigen Umgebungsmedium die höchste Empfindlichkeit im Spektralbereich um 660 nm unter Annahme einer rund 35~nm dicken und 2~mm langen Goldbeschichtung erreicht wird. Weiterhin wurde nachgewiesen, dass mit einer intermediale Schicht aus Cadmiumsulfid die SPR der Mantelmode in einen höheren Spektralbereich verschoben und damit die Empfindlichkeit deutlich verbessert werden kann. Um eine geringe Polarisationsabhängigkeit des Sensors sicherzustellen, wurde ein nasschemisches Abscheidungsverfahren für die allseitige Goldbeschichtung der Sensorfaser entwickelt. Die spezifischen optischen Eigenschaften dieser Abscheidungen wurden mit Hilfe von LPGs untersucht, die durch eine spezielle UV-Belichtung hergestellt wurden. Die Experimente ergaben, dass die komplexe Permittivität nasschemischer Abscheidungen mit Schichtdicken oberhalb von 50~nm mit aufgedampften Goldschichten vergleichbar ist. Die Verluste der adressierten Mantelmoden wurden mit einer äquivalenten Sensoranordnung aus zwei identischen LPG untersucht. Dabei konnte ein Skalierfaktor abgeleitet werden, der die effiziente Berechnung der Mantelmodendämpfung erlaubt. Es wurde nachgewiesen, dass die Brechzahlauflösung etablierter volumenoptischer SPR-Sensoren mit einer einfachen Transmissionsmessung an einer geeigneten Wellenlänge erreicht werden kann. Die äußerst kompakte Sensorfläche des faseroptischen Sensors ermöglicht darüber hinaus die Untersuchung deutlich kleinerer Probenvolumina ohne ein zusätzliches mikrofluidisches System zu benötigen. Es wurde gezeigt, dass sekundäre Brechzahländerungen aufgrund von Temperaturschwankungen oder unspezifische Ablagerungen durch eine differentielle Auswertung zweier identischer Sensoren kompensiert werden können. Die verbleibende Querempfindlichkeit wird durch die Polarisationsabhängigkeit der Sensoren bestimmt. Die geringste Querempfindlichkeit konnte daher mit einer homogenen nasschemischen abgeschiedenen Sensorfläche nachgewiesen werden. / Compact analysis devices which facilitate the rapid detection of specific biochemical substances are in increasing demand in the fields of point-of-care medical diagnostics, bioprocess engineering and environmental engineering. The aim of this work was therefore to design a novel fiber-optic sensor able to detect small refractive index changes such as those caused by molecular binding processes. The high level of sensitivity at the gold-plated tip of the sensor fiber stems from the surface plasmon resonance (SPR) of a single cladding mode, which is the result of a long-period fiber grating (LPG). The transfer function of the sensor was calculated quickly and accurately using a slab waveguide model. It was observed that the highest level of sensitivity in an aqueous ambient medium is achieved at a wavelength of 660 nm assuming a gold coating of 35 nm in thickness and 2 mm in length. Furthermore, it was demonstrated that an intermedial cadmium sulfide layer shifts the SPR of the cladding mode towards higher wavelengths, thus leading to significantly enhanced sensitivity. An electroless plating process for the omnidirectional deposition of gold on the sensor fiber was developed in order to minimize the sensor\'s dependency on polarization. The specific optical properties of the gold layer deposited were investigated with the aid of LPGs fabricated using a special UV exposure method. The experiments showed the complex permittivity of electroless platings with a thickness of over 50 nm to be comparable with that of evaporated gold layers. The losses of the addressed cladding modes were investigated using an equivalent sensor setup consisting of two identical LPGs. This facilitated the determination of a scaling factor enabling the effcient calculation of cladding mode attenuation. It was demonstrated that it is possible to obtain the refractive index resolution of established volume optical SPR sensors with the aid of simple transmission measurements at a specific wavelength. Moreover, the extremely compact sensing area of the fiber-optic sensor enables the investigation of smaller sample volumes without the need for an additional microfluidic system. Secondary refractive index changes caused by temperature fluctuations or unspecific binding events can be compensated for by means of the differential interrogation of two identical fiber-optic sensors. The residual cross sensitivity is determined by the polarisation dependency of the sensor. The lowest cross sensitivity was therefore demonstrated in combination with a homogeneous electroless plated sensor surface.
12

Separation of CO2 using ultra-thin multi-layer polymeric membranes for compartmentalized fiber optic sensor applications

Davies, Benjamin 20 March 2014 (has links)
Carbon dioxide sequestration is one of many mitigation tools available to help reduce carbon dioxide emissions while other disposal/repurposing methods are being investigated. Geologic sequestration is the most stable option for long-term storage of carbon dioxide (CO2), with significant CO2 trapping occurring through mineralization within the first 20-50 years. A fiber optic based monitoring system has been proposed to provide real time concentrations of CO2 at various points throughout the geologic formation. The proposed sensor is sensitive to the refractive index (RI) of substances in direct contact with the sensing component. As RI is a measurement of light propagating through a bulk medium relative to light propagating through a vacuum, the extraction of the effects of any specific component of that medium to the RI remains very difficult. Therefore, a requirement for a selective barrier to be able to prevent confounding substances from being in contact with the sensor and specifically isolate CO2 is necessary. As such a method to evaluate the performance of the selective element of the sensor was investigated. Polybenzimidazole (PBI) and VTEC polyimide (PI) 1388 are high performance polymers with good selectivity for CO2 used in high temperature gas separations. These polymers were spin coated onto a glass substrate and cured to form ultra-thin (>10 μm) membranes for gas separation. At a range of pressures (0.14 –0.41 MPa) and a set temperature of 24.2±0.8 °C, intrinsic permeabilities to CO2 and nitrogen (N2) were investigated as they are the gases of highest prevalence in underground aquifers. Preliminary RI testing for proof of concept has yielded promising results when the sensor is exposed exclusively to CO2 or N2. However, the use of both PBI and VTEC PI in these trials resulted in CO2 selectivities of 0.72 to 0.87 and 0.33 to 0.63 respectively, for corresponding feed pressures of 0.14 to 0.41 MPa. This indicates that both of the polymers are more selective for N2 and should not be used in CO2 sensing applications as confounding gas permeants, specifically N2, will interfere with the sensing element. / Graduate / 0428 / 0495 / 0542 / ben.t.davies@gmail.com

Page generated in 0.1038 seconds