• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Polarisation dynamique nucléaire à basse température et fort champ magnétique pour des applications biomédicales en imagerie spectroscopique par résonance magnétique

Goutailler, Florent 26 January 2011 (has links) (PDF)
Le travail de cette thèse a consisté à concevoir, réaliser et optimiser un montage expérimental de Polarisation Dynamique Nucléaire multi-échantillons pour des applications biomédicales en Imagerie Spectroscopique par Résonance Magnétique. Ce montage est constitué d'un aimant à fort champ magnétique (3,35T), dans lequel se place un système cryogénique à bain d'hélium (He4) liquide pompé pouvant atteindre des températures inférieures à 1,2K. Un ensemble d'inserts permet d'effectuer les différentes étapes du processus PDN dont l'irradiation des échantillons par un champ micro-onde (f=94GHz et P=50mW) et le suivi de leur polarisation par Résonance Magnétique Nucléaire. Ce système permet de polariser jusqu'à trois échantillons, de volume proche de 1mL, à des taux de polarisation de quelques pourcents. Il présente une forte autonomie supérieure à quatre heures, autorisant ainsi la polarisation de molécules à longues constantes de temps de polarisation. La possibilité de disposer quasi-simultanément, après dissolution, de plusieurs échantillons fortement polarisés ouvre la voie à de nouvelles applications dans le domaine de l'imagerie biomédicale
2

Polarisation dynamique nucléaire a basse température et fort champ magnétique pour des applications biomédicales en imagerie spectroscopique par résonance magnétique

Goutailler, Florent 26 January 2011 (has links) (PDF)
Le travail de cette thèse a consisté à concevoir, réaliser et optimiser un montage expérimental de Polarisation Dynamique Nucléaire multi-échantillons pour des applications biomédicales en Imagerie Spectroscopique par Résonance Magnétique. Ce montage est constitué d'un aimant à fort champ magnétique (3,35T), dans lequel se place un système cryog&nique à bain d'hélium (He4) liquide pompé pouvant atteindre des températures infèrieures à 1,2K. Un ensemble d'inserts permet d'effectuer les différentes étapes du processus PDN dont l'irradiation des échantillons par un champ micro-onde (f=94GHz et P=50mW) et le suivi de leur polarisation par Résonance Magnétique Nucléaire. Ce système permet de polariser jusqu'à trois échantillons, de volume proche de 1mL, à des taux de polarisation de quelques pourcents. Il présente une forte autonomie supérieure à quatre heures, autorisant ainsi la polarisation de molécules à longues constantes de temps de polarisation. La possibilité de disposer quasi-simultanèment, après dissolution, de plusieurs échantillons fortement polarisés ouvre la voie à de nouvelles applications dans le domaine de l'imagerie biomédicale.
3

Étude et analyse numérique d’un jet chaud débouchant dans un écoulement transverse en utilisant des simulations aux échelles résolues / Numerical investigations on a hot jet in cross flow using scale-resolving simulations

Duda, Benjamin Markus 19 September 2012 (has links)
Des méthodes numériques sont présentées qui permettent la simulation de jets chauds débouchants dans un écoulement transverse aux grands nombres de Reynolds et aux rapports des vitesses faibles. Différentes approches pour la modélisation de turbulence, c'est-à-dire URANS, SAS, DDES et ELES, sont validées par comparaison à des données expérimentales pour une configuration générique, soulignant la nécessité de résoudre les différentes échelles turbulentes pour une prévision correcte du mélange thermique. L'analyse de la solution instationnaire permet l'identification de processus dynamiques intrinsèques ainsi que des phénomènes de mélange et l'application de l'analyse en composantes principales révèle l'ondulation latérale du sillage de jet. Du fait du caractère multi-échelles qui se manifeste dans la simulation d'un jet débouchant sur une configuration avion, l'approche séquentielle basée sur le modèle SAS est mise en place. Comme les résultats pour la sortie d'un système de dégivrage de nacelle sont en bon accord avec les données d'essai en vol, cette approche est finalement appliquée à la sortie complexe d'un système de pre-cooler, mettant en valeur sa capacité à être appliquée dans un processus industriel. / Numerical methods for the simulation of hot jets in cross flow at high Reynolds numbers and small momentum ratios are presented. Different turbulence modeling strategies, i.e. URANS, SAS, DDES and ELES, are validated against experimental data on a generic configuration, highlighting the necessity of scale-resolution for a correct prediction ofthermal mixing. The analysis of transient flow simulations allows the identification of inherent flow dynamics as well as mixing phenomena and the application of the Proper Orthogonal Decomposition revealed the lateral wake meandering as being one of them. Due to the multi-scale problem which arises when simulating jets in cross flow on real aircraft configurations, the sequential approach based on the SAS turbulence model is introduced. As results for the exhaust of a nacelle anti-icing system comprising multiple jets in cross flow agree well with flight test data, the approach is applied in a last step to the complex exhaust of a pre-cooling system, emphasizing the capabilities of this methodology in an industrial environment.
4

Polarisation dynamique à basse température et fort champ magnétique pour des applications biomédicales en imagerie spectroscopique par résonance magnétique

Goutailler, Florent 26 January 2011 (has links) (PDF)
Le travail de cette thèse a consisté à concevoir, réaliser et optimiser un montage expérimental de Polarisation Dynamique Nucléaire multi-échantillons pour des applications biomédicales en Imagerie Spectroscopique par Résonance Magnétique. Ce montage est constitué d'un aimant à fort champ magnétique (3,35T), dans lequel se place un système cryogénique à bain d'hélium (He$^4$) liquide pompé pouvant atteindre des températures inférieures à 1,2K. Un ensemble d'inserts permet d'effectuer les différentes étapes du processus PDN dont l'irradiation des échantillons par un champ micro-onde (f=94GHz et P=50mW) et le suivi de leur polarisation par Résonance Magnétique Nucléaire. Ce système permet de polariser jusqu'à trois échantillons, de volume proche de 1mL, à des taux de polarisation de quelques pourcents. Il présente une forte autonomie supérieure à quatre heures, autorisant ainsi la polarisation de molécules à longues constantes de temps de polarisation. La possibilité de disposer quasi-simultanément, après dissolution, de plusieurs échantillons fortement polarisés ouvre la voie à de nouvelles applications dans le domaine de l'imagerie biomédicale.
5

Polarisation dynamique nucléaire à basse température et fort champ magnétique pour des applications biomédicales en imagerie spectroscopique par résonance magnétique / Dynamic nuclear polarization at low temperature and high magnetic field for biomedical applications in magnetic resonance spectroscopic imaging

Goutailler, Florent 26 January 2011 (has links)
Le travail de cette thèse a consisté à concevoir, réaliser et optimiser un montage expérimental de Polarisation Dynamique Nucléaire multi-échantillons pour des applications biomédicales en Imagerie Spectroscopique par Résonance Magnétique. Ce montage est constitué d'un aimant à fort champ magnétique (3,35T), dans lequel se place un système cryogénique à bain d'hélium (He4) liquide pompé pouvant atteindre des températures inférieures à 1,2K. Un ensemble d'inserts permet d'effectuer les différentes étapes du processus PDN dont l'irradiation des échantillons par un champ micro-onde (f=94GHz et P=50mW) et le suivi de leur polarisation par Résonance Magnétique Nucléaire. Ce système permet de polariser jusqu'à trois échantillons, de volume proche de 1mL, à des taux de polarisation de quelques pourcents. Il présente une forte autonomie supérieure à quatre heures, autorisant ainsi la polarisation de molécules à longues constantes de temps de polarisation. La possibilité de disposer quasi-simultanément, après dissolution, de plusieurs échantillons fortement polarisés ouvre la voie à de nouvelles applications dans le domaine de l'imagerie biomédicale / The aim of this thesis work was to design, build and optimize a large volume multisamples DNP (Dynamic Nuclear Polarization) polarizer dedicated to Magnetic Resonance Spectroscopic Imaging applications. The experimental system is made up of a high magnetic field magnet (3,35T) in which takes place a cryogenic system with a pumped bath of liquid helium (4He) allowing temperatures lower than 1,2K. A set of inserts is used for the different steps of DNP : irradiation of the sample by a microwave field (f=94GHz and P=50mW), polarization measurement by Nuclear Magnetic Resonance. . . With this system, up to three samples of 1mL volume can be polarized to a rate of few percents. The system has a long autonomy of four hours, so it can be used for polarizing molecules with a long time constant of polarization. Finally, the possibility to get quasisimultaneously, after dissolution, several samples with a high rate of polarization opens the way of new applications in biomedical imaging

Page generated in 0.0839 seconds