Influência da qualidade de imagens CT na avaliação da distribuição de dose em planejamento radioterápico baseado em métodos Monte Carlo / Influência da qualidade de imagens CT na avaliação da distribuição de dose em planejamento radioterápico baseado em métodos Monte CarloOliveira, Alex Cristóvão Holanda de 31 January 2012 (has links)
Submitted by Danielle Karla Martins Silva (danielle.martins@ufpe.br) on 2015-03-12T18:03:49Z
No. of bitstreams: 2
DISSERTACAO_VersaoFinal_Alex.pdf: 5202282 bytes, checksum: 412feea4e159e10abed8409d3f2010ee (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2015-03-12T18:03:49Z (GMT). No. of bitstreams: 2
DISSERTACAO_VersaoFinal_Alex.pdf: 5202282 bytes, checksum: 412feea4e159e10abed8409d3f2010ee (MD5)
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Previous issue date: 2012 / CNPq / O planejamento radioterápico é o processo de determinar a maneira mais apropriada de
irradiar o paciente. Entre as etapas mais importantes do processo de planejamento está a
aquisição de imagens do paciente e a avaliação da distribuição de dose. Os sistemas
computacionais baseados em métodos Monte Carlo estão se tornando a técnica mais avançada
para avaliação de dose, fornecendo resultados mais realísticos. As imagens do paciente são
predominantemente obtidas por Tomografia Computadorizada (CT), que fornecem, não só
informações relevantes sobre a anatomia, como também permitem obter uma distribuição
espacial das densidades e composições químicas dos órgãos e tecidos através de métodos de
conversão de números CT. A relação entre número CT e densidade é estabelecida por uma
curva de calibração obtida empiricamente a partir de imagens CT de um fantoma físico que
possui vários materiais com densidades diferentes. As composições químicas são atribuídas a
grupos determinados segmentando-se a escala de números CT. Contudo, estes métodos de
conversão de números CT não levam em consideração a qualidade das imagens. Neste
trabalho são avaliadas as influências de alguns parâmetros de qualidade de imagem CT
(resolução de baixo contraste, exatidão dos números CT e ruído) na distribuição de dose em
planejamento radioterápico. Para isso, diversas etapas foram realizadas, entre elas: construção
de um fantoma físico; aquisição de um conjunto de imagens CT deste; desenvolvimento de
um software em linguagem de programação C#; e simulações Monte Carlo no código
GEANT4 de irradiações do fantoma utilizando as suas imagens (após a conversão de números
CT) e uma representação computacional do mesmo. Essencialmente, a análise dos resultados
foi realizada comparando-se as distribuições de dose resultantes das simulações. Nessas
comparações, foram encontrados muitos erros acima dos 5%, limiar estabelecido pela ICRU
24 (1976). Isso resulta da inexatidão na distribuição espacial de densidades e composições
químicas e, portanto, a qualidade das imagens CT influencia consideravelmente a distribuição
de dose. A conversão para densidade é afetada pelo ruído e pela exatidão de números CT, e a
conversão para composição química, pelo ruído e pela amostragem de números CT de objetos
com densidades próximas. A resolução de baixo contraste não demonstrou um efeito
perceptível.
|
2 |
Desenvolvimento de um sistema computacional baseado no código Geant4 para avaliações dosimétricas em radioterapia.OLIVEIRA, Alex Cristóvão Holanda de 29 April 2016 (has links)
Submitted by Rafael Santana (rafael.silvasantana@ufpe.br) on 2017-05-11T17:49:20Z
No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Tese_AlexOliveira_PROTEN_2016.pdf: 2268858 bytes, checksum: 5f7228b81f8233f71ade4db328005315 (MD5) / Made available in DSpace on 2017-05-11T17:49:20Z (GMT). No. of bitstreams: 2
license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5)
Tese_AlexOliveira_PROTEN_2016.pdf: 2268858 bytes, checksum: 5f7228b81f8233f71ade4db328005315 (MD5)
Previous issue date: 2016-04-29 / CNEN / A incidência de câncer tem crescido no Brasil, assim como em todo mundo, acompanhando a
mudança do perfil etário da população. Uma das técnicas mais importantes e comumente
utilizadas no tratamento do câncer é a radioterapia. Em torno de 60% dos casos novos de
neoplasias malignas utiliza-se a radioterapia. O equipamento mais utilizado para radioterapia
é o acelerador linear (Linac) que produz feixes de elétrons ou raios-X na faixa energética de 5
a 30 MeV. A maneira mais apropriada de irradiar o paciente é determinada durante o
planejamento. Atualmente, o sistema computacional de planejamento radioterápico (TPS –
Treatment Planning System) é a principal e a mais importante ferramenta no processo de
planejamento em radioterapia. O principal objetivo desse trabalho foi desenvolver um sistema
computacional baseado no código Monte Carlo (MC) Geant4 para avaliações dosimétricas em
radioterapia com feixe de fótons. Além de planejamentos, essas avaliações podem ser
realizadas para pesquisa e controle de qualidade de equipamentos e de TPSs. O sistema
computacional, denominado Quimera, é composto de uma interface gráfica de usuário (qGUI)
e três aplicativos MC (qLinacs, qMATphantoms e qNCTphantoms). A qGUI tem a função de
interface para os aplicativos MC, criando ou editando os arquivos de entrada, executando as
simulações e analisando os resultados. O qLinacs é usado para modelagem e geração de
feixes de irradiação (espaços de fase) de Linacs. O qMATphantoms e o qNCTphantoms são
usados para avaliações de dose em modelos virtuais de fantomas físicos e em imagens de
tomografia computadorizada (CT), respectivamente. A partir de dados do fabricante, foram
modelados no qLinacs um Linac e um colimador multifolhas (MLC) da Varian. As
modelagens do Linac e do MLC foram validadas utilizando dados experimentais. As
validações do qMATphantoms e do qNCTphantoms foram realizadas utilizando espaços de
fase da IAEA (International Atomic Energy Agency). Nessa primeira versão, o Quimera pode
ser usado para pesquisa, planejamentos radioterápicos de tratamentos simples e controle de
qualidade em radioterapia com feixes de fótons gerados por Linacs. Os aplicativos MC
funcionam independentes da qGUI e essa pode ser usada para manipulação de imagens CT e
análise de resultados de outros aplicativos MC. Devido à estrutura modular do Quimera, é
possível adicionar novos aplicativos MC, permitindo o desenvolvimento de novas pesquisas,
modelagem de Linacs e MLCs de diferentes fabricantes, o uso de outras técnicas (feixe de
elétrons, prótons, íons pesados, tomoterapia, etc.) e aplicações em áreas correlatas
(braquiterapia, radioproteção, etc.). Esse trabalho é uma iniciativa para desenvolvimento
colaborativo de um sistema computacional completo que possa ser usado em radioterapia,
tanto na prática clínica e técnica quanto na pesquisa. / The incidence of cancer has grown in Brazil, as well as around the world, following the
change in the age profile of the population. One of the most important techniques and
commonly used in cancer treatment is radiotherapy. Around 60% of new cases of cancer use
radiation in at least one phase of treatment. The most used equipment for radiotherapy is a
linear accelerator (Linac) which produces electron or X-ray beams in energy range from 5 to
30 MeV. The most appropriate way to irradiate a patient is determined during treatment
planning. Currently, treatment planning system (TPS) is the main and the most important tool
in the process of planning for radiotherapy. The main objective of this work is to develop a
computational system based on the MC code Geant4 for dose evaluations in photon beam
radiotherapy. In addition to treatment planning, these dose evaluations can be performed for
research and quality control of equipment and TPSs. The computer system, called Quimera,
consists of a graphical user interface (qGUI) and three MC applications (qLinacs,
qMATphantoms and qNCTphantoms). The qGUI has the function of interface for the MC
applications, by creating or editing the input files, running simulations and analyzing the
results. The qLinacs is used for modeling and generation of Linac beams (phase space). The
qMATphantoms and qNCTphantoms are used for dose calculations in virtual models of
physical phantoms and computed tomography (CT) images, respectively. From
manufacturer's data, models of a Varian Linac photon beam and a Varian multileaf collimator
(MLC) were simulated in the qLinacs. The Linac and MLC modelings were validated using
experimental data. qMATphamtoms and qNCTphantoms were validated using IAEA phase
spaces. In this first version, the Quimera can be used for research, radiotherapy planning of
simple treatments and quality control in photom beam radiotherapy. The MC applications
work independent of the qGUI and the qGUI can be used for handling CT images and
analysis of results from other MC applications. Due to the modular structure of the Quimera,
one can add new MC applications, allowing the development of new research for use of other
techniques (electron beam, protons, heavy ions, tomotherapy, etc.) and applications
(brachytherapy, radiation protection, etc.) in radiotherapy. Quimera is an initiative for
collaborative development of a complete computer system that can be used in radiotherapy,
for clinical and technical practice and research
|
3 |
Análise de sensibilidade e resíduos em modelos de regressão com respostas bivariadas por meio de cópulas / Bivariate response regression models with copulas: Sensitivity and residual analysisGomes, Eduardo Monteiro de Castro 01 February 2008 (has links)
Neste trabalho são apresentados modelos de regressão com respostas bivariadas obtidos através de funções cópulas. O objetivo de utilizar estes modelos bivariados é modelar a correlação entre eventos e captar nos modelos de regressão a influência da associação entre as variáveis resposta na presença de censura nos dados. Os parâmetros dos modelos, são estimados por meio dos métodos de máxima verossimilhança e jackknife. Alguns métodos de análise de sensibilidade como influência global, local e local total de um indivíduo, são introduzidos e calculados considerando diferentes esquemas de perturbação. Uma análise de resíduos foi proposta para verificar a qualidade do ajuste dos modelos utilizados e também foi proposta novas medidas de resíduos para respostas bivariadas. Métodos de simulação de Monte Carlo foram conduzidos para estudar a distribuição empírica dos resíduos marginais e bivariados propostos. Finalmente, os resultados são aplicados à dois conjuntos de dados dsponíveis na literatura. / In this work bivariate response regression models are presented with the use of copulas. The objective of this approach is to model the correlation between events and capture the influence of this correlation in the regression parameters. The models are used in the context of survival analysis and are ¯tted to two data sets available in the literature. Inferences are obtained using maximum likelihood and Jackknife methods. Sensitivity techniques such as local and global in°uence are proposed and calculated. A residual analysis is proposed to check the adequacy of the models and simulation methods are used to asses the empirical distribution of the marginal univariate and bivariate residual measures proposed.
|
4 |
Análise de sensibilidade e resíduos em modelos de regressão com respostas bivariadas por meio de cópulas / Bivariate response regression models with copulas: Sensitivity and residual analysisEduardo Monteiro de Castro Gomes 01 February 2008 (has links)
Neste trabalho são apresentados modelos de regressão com respostas bivariadas obtidos através de funções cópulas. O objetivo de utilizar estes modelos bivariados é modelar a correlação entre eventos e captar nos modelos de regressão a influência da associação entre as variáveis resposta na presença de censura nos dados. Os parâmetros dos modelos, são estimados por meio dos métodos de máxima verossimilhança e jackknife. Alguns métodos de análise de sensibilidade como influência global, local e local total de um indivíduo, são introduzidos e calculados considerando diferentes esquemas de perturbação. Uma análise de resíduos foi proposta para verificar a qualidade do ajuste dos modelos utilizados e também foi proposta novas medidas de resíduos para respostas bivariadas. Métodos de simulação de Monte Carlo foram conduzidos para estudar a distribuição empírica dos resíduos marginais e bivariados propostos. Finalmente, os resultados são aplicados à dois conjuntos de dados dsponíveis na literatura. / In this work bivariate response regression models are presented with the use of copulas. The objective of this approach is to model the correlation between events and capture the influence of this correlation in the regression parameters. The models are used in the context of survival analysis and are ¯tted to two data sets available in the literature. Inferences are obtained using maximum likelihood and Jackknife methods. Sensitivity techniques such as local and global in°uence are proposed and calculated. A residual analysis is proposed to check the adequacy of the models and simulation methods are used to asses the empirical distribution of the marginal univariate and bivariate residual measures proposed.
|
Page generated in 0.0794 seconds