• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 147
  • 45
  • 45
  • 45
  • 45
  • 45
  • 45
  • 41
  • 22
  • 14
  • 12
  • 12
  • 3
  • 3
  • 1
  • Tagged with
  • 375
  • 375
  • 93
  • 66
  • 59
  • 57
  • 56
  • 51
  • 47
  • 45
  • 45
  • 45
  • 42
  • 41
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Developing a QA procedure for gated VMAT SABR treatments using 10 MV beam in flattening-filter free mode

Chitsazzadeh, Shadi 02 September 2016 (has links)
Respiratory gating limits the radiation to a specific part of the breathing cycle and reduces the size of the Planning Target Volume (PTV). This thesis describes a novel quality assurance method for amplitude gating of Stereotactic ABlative Ra- diotherapy (SABR) treatments of liver delivered using Volumetric Modulated Arc Therapy (VMAT) using a 10 MV beam in Flattening Filter Free (FFF) mode. This method takes advantage of the high dose gradient region of SABR treatments to detect any inaccuracies in the performance of the Varian Real-time Position Manage- ment (RPM) gating system. This study involves the design and construction of an interface that connects the translation stage of the Quasar respiratory motion phan- tom to an ion chamber insert. This insert can hold and drive a pinpoint ion chamber inside the ArcCheck diode array based on the breathing pattern imported into the Quasar phantom. The pinpoint ion chamber dose measurements were acquired at the isocentre and along the penumbra using synthetic breathing traces. Our results show that the changes in PTV size and exhale duration do not influence the dose measured by iii the pinpoint ion chamber. Changes in gate width and baseline drift, however, affect the detector residual motion, which results in variation in the level of dose-blurring and interplay effects. A new parameter, Average Residual Detector Displacement (ARDD), is introduced in this thesis and is used to take into account the effect of dose-blurring. For gate widths smaller than 8 mm and baseline drift levels smaller than 4 mm, if the effect of dose-blurring is taken into account, the pinpoint ion chamber dose measurements are mostly within 2σ positional uncertainty from the Eclipse dose profile. As the gate width and baseline drift increases, accounting for the dose-blurring effect is no longer sufficient to explain the discrepancy between measured and calculated doses. This thesis also includes dose measurements for radiation deliveries that are gated using six real breathing traces with gate widths of 2 mm, 2.8 mm, and 4 mm. Once the parameter ARDD is used to account for dose-blurring, the dose measurements are mostly within 2σ positional uncertainty from Eclipse calculated doses. These results demonstrate the reliability and accuracy of the RPM gating system at British Columbia Cancer Agency - Vancouver Island Cancer Centre (BCCA - VICC). Lastly, the overall dose distribution was monitored using the ArcCheck diode array measure- ments under various gating schemes and was compared to the Eclipse calculated dose map using a 2D Gamma analysis. The Gamma pass rates for 2mm/2% criteria show that the beam interruptions during the treatment do not degrade the fidelity of the radiation delivery in a gated treatment. / Graduate
32

Predictive modeling of post radiation-therapy recurrence for gynecological cancer patients using clinical and histopathology imaging features

Zou, Yujing January 2023 (has links)
No description available.
33

Experimental Evaluation of Stability with the Aerrow Graphite Calorimetry System

MacKay, Norman January 2023 (has links)
No description available.
34

Image registration for dose accumulation between external beam radiotherapy and brachytherapy for cervical cancer: Comparison to clinical practice

Zhanuzakov, Medet January 2023 (has links)
No description available.
35

Bayesian Optimization in Multi-Objective Treatment Plan Optimization of High Dose Rate Brachytherapy

Jafarzadeh, Seyedhossein January 2023 (has links)
No description available.
36

Cone-beam computed tomography image-based radiomics analysis of early tumor changes after radiotherapy in an orthotopic lung cancer mouse model.

Yadav, Ranjan January 2023 (has links)
No description available.
37

Commissioning of deformable image registration for lung re-irradiation

Di Francesco, Marco January 2022 (has links)
No description available.
38

Quality assurance for mixed electron-photon beam radiation therapy using treatment log files and MapCHECK

Tai, Yee Man January 2022 (has links)
No description available.
39

Shape recognition for MRI-based prediction of treatment outcomes in neoadjuvant treatment of breast cancer

Badalan, Alexandru January 2022 (has links)
No description available.
40

Development of a small, cost-efficient scintillation detector for use in automated synthesis of PET radiopharmaceuticals.

Ahn, Sae Hyun January 2023 (has links)
No description available.

Page generated in 0.2944 seconds