Spelling suggestions: "subject:"macacos planos"" "subject:"macaco planos""
1 |
Análise numérica da representatividade de ensaios com macacos planos em paredes de alvenaria de pedraOliveira, Bruno de Sousa January 2010 (has links)
Tese de mestrado integrado. Engenharia Civil. Faculdade de Engenharia. Universidade do Porto. 2010
|
2 |
Técnica de macacos planos na avaliação de estruturas de alvenaria com blocos vazados de concretoSoriani, Mateus de Oliveira 02 February 2016 (has links)
Submitted by Izabel Franco (izabel-franco@ufscar.br) on 2016-10-06T20:50:11Z
No. of bitstreams: 1
DissMOS.pdf: 8901062 bytes, checksum: 08b58e3ccf045cae12fa956cafaba68c (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-10-20T19:37:55Z (GMT) No. of bitstreams: 1
DissMOS.pdf: 8901062 bytes, checksum: 08b58e3ccf045cae12fa956cafaba68c (MD5) / Approved for entry into archive by Marina Freitas (marinapf@ufscar.br) on 2016-10-20T19:38:01Z (GMT) No. of bitstreams: 1
DissMOS.pdf: 8901062 bytes, checksum: 08b58e3ccf045cae12fa956cafaba68c (MD5) / Made available in DSpace on 2016-10-20T19:38:06Z (GMT). No. of bitstreams: 1
DissMOS.pdf: 8901062 bytes, checksum: 08b58e3ccf045cae12fa956cafaba68c (MD5)
Previous issue date: 2016-02-02 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / The present study delas with nondestructive evaluation of modern masonry built with hollow
concrete blocks, through the flatjack technique. The technique is already used to evaluate
masonry structures with solid bricks and stones and it is considered as efficient to obtain in
situ mechanical properties, without any permanent damages. The tests in solid unit masonry
using flatjack is included in international standards and recommendations as: ASTM C 1196 e
1197-09 e RILEM MDT.D.4 e MDT.D.5-04. The current standards and the practical
applications deal with masonry with brick or stones elements only. Nondestructive evaluation
in modern hollow block masonry is demanded and the flatjack can be used in these cases.
However, the current available jack can be used only on solid units, due to its geometrical
limitations. Therefore, this research proposes to adapt the flatjack technique for
nondestructive evaluation in modern masonry built with hollow concrete blocks. The
analyzed test is the deformability one, which the modulus of elasticity and an estimative of
the compressive strength is wanted. In this research, a new flatjack equipment was developed
to allow its application on hollow blocks and it was tested in modern masonry samples. The
new equipment was successfully developed and it was used in flatjack tests on hollow
concrete block masonry. As main results, masonry properties obtained from the flatjack
technique was close to the expected ones, indicating the great potentiality of the technique for
hollow blocks also. / O presente trabalho trata da avaliação não destrutiva em alvenarias estruturais de blocos de
concreto, através da técnica de macacos planos. A técnica já é utilizada em análises de
estruturas de alvenaria de tijolos maciços e de pedras, sendo considerada bastante eficiente
para a obtenção de propriedades mecânicas, no próprio local, sem causar danos permanentes.
Os testes com macacos planos em alvenarias de unidades maciças já fazem parte de normas e
recomendações internacionais como: ASTM C 1196 e 1197-09 e RILEM MDT.D.4 e
MDT.D.5-04. As normas e as aplicações práticas já realizadas tratam apenas de alvenarias
com elementos de tijolos ou pedras. Existe uma demanda para avaliação estrutural não
destrutiva em alvenarias modernas, na maioria compostas por blocos vazados, de maneira que
a técnica poderia ser utilizada. Entretanto, os macacos atualmente disponíveis podem ser
aplicados em unidades maciças apenas, devido a limitações geométricas. Portanto, este estudo
visa adaptar a técnica de macacos planos para análise não destrutiva em alvenarias modernas,
compostas por blocos vazados de concreto. O teste adaptado é o teste de deformabilidade, em
que se visa obter o módulo de elasticidade e uma estimativa da resistência à compressão. Para
a realização deste trabalho, um novo modelo de macaco foi desenvolvido, possibilitando sua
aplicação em blocos vazados, sendo testado em amostras de paredes. O equipamento foi
desenvolvido com sucesso e utilizado em testes de deformabilidade em paredes com blocos de
concreto. Como resultado, propriedades foram obtidas com boa proximidade com os valores
esperados, indicando potencialidade da técnica para esse tipo de aplicação.
Palavras-chave: Macacos planos; teste de deformabilidade; avaliação não destrutiva; blocos
vazados de concreto.
|
Page generated in 0.0541 seconds