Micro/nanoscale tribology of linear tape drives

Goldade, Anton Viktorovich, January 2003 (has links)
Thesis (Ph. D.)--Ohio State University, 2003. / Title from first page of PDF file. Document formatted into pages; contains xviii, 191 p. : ill. Advisor: Bharat Bhushan, Department of Mechanical Engineering. Includes bibliographical references (p. 179-183).
2

The development of alternative marketing strategies for a new product line in Hong Kong's export and local markets: cassette tapes.

January 1975 (has links)
Summary in Chinese. / Thesis (M.B.A.)--Chinese University of Hong Kong. / Bibliography: leaves 126-128.
3

Data recovery from magnetic media using magnetic force microscopy

Ferrett, Terry R. January 1900 (has links)
Thesis (M.S.)--West Virginia University, 2008. / Title from document title page. Document formatted into pages; contains x, 81, 9 p. : ill. (some col.). Includes abstract. Includes bibliographical references (p. 73-75).
4

Correntes críticas e comportamento dinâmico dos vórtices em fitas supercondutoras do tipo II com arranjos conformes de centros de aprisionamento /

Filenga, Daví. January 2016 (has links)
Orientador: Pablo Antonio Venegas Urenda / Banca: Dayse Iara dos Santos / Banca: Durval Rodrigues Júnior / O Programa de Pós Graduação em Ciência e Tecnologia de Materiais, PosMat, tem caráter institucional e integra a as atividades de pesquisa em materiais de diversos campi / Resumo: Na presente dissertação realizou-se o estudo das forças críticas e do comportamento dinâmico dos vórtices magnéticos de fitas supercondutoras do tipo II com arranjos conformes de centros de aprisionamento (pinning), bem como de diversos outros tipos de arranjos e também de diferentes trechos de arranjos. Além dos efeitos da geometria finita e aprisionamento, foi analisado o comportamento do sistema ao variar parâmetros externos como força de transporte e campo magnético. Os sistemas simulados correspondem a supercondutores bidimensionais, finitos na direção transversal e infinitos na direção longitudinal. A descrição das interações existentes no sistema pôde ser feita através de um conjunto de equações de Langevin, as quais foram resolvidas utilizando a técnica de Dinâmica Molecular. As soluções destas equações permitiram, dentre outros resultados, a obtenção das trajetórias e velocidades dos vórtices. Através das trajetórias, foi possível determinar o comportamento dinâmico das linhas de fluxo, e através das velocidades, os valores de força crítica. Para obter as posições iniciais dos vórtices, foi utilizado um algoritmo de Recozimento Simulado Generalizado (Generalized Simulated Annealing), o qual permitiu obter as configurações de menor energia do sistema. Os cálculos realizados foram feitos para 154 diferentes sistemas, que consistiram na análise do comportamento das interações neles existentes ao variar o campo magnético externo (H) aplicado nas amostras, bem como na a... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In this work we study the critical forces and dynamic behavior of magnetic vortices in type II superconducting tapes with conformal pinning arrays, as well several other types of arrays and also parts of arrays. In addition to the effects of finite geometry and pinning, we analyze system behavior by varying external parameters such as transport force and magnetic field. The simulated systems corresponds a two-dimensional superconductor, finite in the transverse direction and infinite in the longitudinal direction. The description of the interactions existing in the system can be made via a set of Langevin equations which were solved using Molecular Dynamics techniques. The solutions of these equations allowed, among other results, to obtain the trajectories and velocities of the vortices. Through the trajectories, it was possible to determine the dynamic behavior of the vortex lines, and through the velocities, the values of critical force. To obtain the initial positions of the vortices, we use a Generalized Simulated Annealing algorithm, which sought the settings of the lower energy system. Our calculations were made for 154 different systems, consisting in analyzing the interaction behavior contained in the systems by varying the external magnetic field (H) applied in the samples and the analysis of size effects of superconducting tapes using different arrays and parts of arrays of pinning centers. To study the influence of the applied magnetic field, a scan was taken with... (Complete abstract click electronic access below) / Mestre
5

Adhesive and viscous effects of several lubricants at the slider/disk interface

Johnson, Janice K. 05 1900 (has links)
No description available.
6

Measurements, characterization, and system design for digital storage /

Friedmann, Arnon A., January 1997 (has links)
Thesis (Ph. D.)--University of California, San Diego, 1997. / Vita. Includes bibliographical references.
7

Melhoramento de sensores magnetostrictivos de deformação

Dalponte, Alessandro 21 February 2017 (has links)
Fitas magnéticas amorfas vêm demonstrando uma ampla variedade de aplicações sensoriais devido às suas propriedades magnéticas. A capacidade de serem interrogadas remotamente permite sua aplicação em locais onde limitações físicas impedem o uso de sensores com conexões cabeadas. A capacidade de adquirirem uma anisotropia magnética transversal através de tratamentos térmicos, sob campo magnético e/ou tensão, é o que torna esses materiais atraentes para a aplicação em sensores magnetostrictivos de deformação com acesso remoto. Os materiais avaliados neste trabalho, Metglas 2826MB3, Yeke 1k501, Yeke 1k501a, Vitrovac 7600, Vitroperm 800 e as fitas de EAS Tags, apresentavam curvas de magnetização características de materiais que não possuem uma anisotropia magnética transversal. Isto serviu de motivação para a realização de tratamentos termomagnéticos. Os tratamentos foram realizados sob campo magnético transversal de aproximadamente 500 Oe e nas temperaturas de 235, 275, 315 e 350˚C por tempos de 15, 30 e 60 minutos, com um forno construído em laboratório. Isto resultou em melhorias consideráveis na forma de suas curvas ΔE, tornando-as mais assimétricas e aumentando as variações de frequência que estes materiais podem apresentar. Os tratamentos resultaram também em curvas M-H lineares, susceptibilidade magnética constante até a saturação. Foi construída uma bancada para aplicação de tensões de até 30 MPa nas amostras. A maior assimetria das curvas ΔE para o par ressonador e transdutor (partes componentes do sensor de deformação) permitiu maior resposta de variação de frequência de ressonância do sensor durante testes de tração. No melhor dos casos, uma variação de frequência superior a 5 kHz foi detectada para deformações de aproximadamente 260 ppm, ao se utilizar um par ressonador e transdutor de Metglas 2826MB3 tratados termomagneticamente. Medindo-se as curvas ΔE de uma fita de Metglas 2826MB3, tratada, sobre substratos de aço 1010, material magneticamente mole, observou-se que as mesmas ainda estavam presentes. Porém, apresentam sua forma alterada devido à interação com aço. Simulações realizadas com o software FEMM, auxiliaram na compreensão de fenômenos ocorridos nos testes de deformação e na interação entre a fita e os substratos magnéticos moles. / Submitted by Ana Guimarães Pereira (agpereir@ucs.br) on 2017-04-06T19:26:08Z No. of bitstreams: 1 Dissertacao Alessandro Dalponte.pdf: 3408308 bytes, checksum: 24cdc0372903d233d5c2d5846465cccd (MD5) / Made available in DSpace on 2017-04-06T19:26:08Z (GMT). No. of bitstreams: 1 Dissertacao Alessandro Dalponte.pdf: 3408308 bytes, checksum: 24cdc0372903d233d5c2d5846465cccd (MD5) Previous issue date: 2017-04-06 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPES. / Magnetic amorphous ribbons have a great variety of sensorial applications due to their magnetic properties. The possibility of being remotely queried allows their application in cases where sensors with wired connections present a physical limitation. The capability of acquiring a transverse magnetic anisotropy through thermal treatments, under applied magnetic field and/or stress, is what makes these materials attractive for application in magnetostrictive strain-gauges. The materials studied in this work, Metglas 2826MB3, Yeke 1k501, Yeke 1k501a, Vitrovac 7600, Vitroperm 800 and a commercial EAS Tags, presented magnetization curves with characteristics of materials with reduced transverse magnetic anisotropy. This was the motivation to carry out thermomagnetic treatments. The treatments were carried out under a magnetic field of approximately 500 Oe, using temperatures of 235, 275, 315 and 350˚C, for periods of 15, 30 and 60 minutes, in a home-made oven. The treatments resulted in considerable improvements on the shape of the ΔE curves, making them more asymmetric and increasing the frequency variations that these materials can present. The treatments also resulted in linear M-H curves, with constant magnetic susceptibility until saturation. A system for the application of stresses up to 30 MPa on the samples was built. ΔE curves with greater asymmetry for the pair resonator transducer (components of the strain-gauge) allowed a greater resonance frequency variation response of the sensor during strain tests. In the best case, a frequency variation above 5 kHz was detected for deformations of approximately 260 ppm, when the pair resonator transducer made of thermomagneticaly treated Metglas 2826MB3 was used. The measurements of the ΔE curves of a treated Metglas 2826MB3 ribbon, placed over 1010 steel substrates, soft magnetic material, showed that they were still detectable. However, their form was altered due to the magnetic interaction with the steel. Simulations made using the software FEMM, helped to understand the observed phenomena during the strain tests and the interaction between the ribbon and the soft magnetic substrates.
8

Melhoramento de sensores magnetostrictivos de deformação

Dalponte, Alessandro 21 February 2017 (has links)
Fitas magnéticas amorfas vêm demonstrando uma ampla variedade de aplicações sensoriais devido às suas propriedades magnéticas. A capacidade de serem interrogadas remotamente permite sua aplicação em locais onde limitações físicas impedem o uso de sensores com conexões cabeadas. A capacidade de adquirirem uma anisotropia magnética transversal através de tratamentos térmicos, sob campo magnético e/ou tensão, é o que torna esses materiais atraentes para a aplicação em sensores magnetostrictivos de deformação com acesso remoto. Os materiais avaliados neste trabalho, Metglas 2826MB3, Yeke 1k501, Yeke 1k501a, Vitrovac 7600, Vitroperm 800 e as fitas de EAS Tags, apresentavam curvas de magnetização características de materiais que não possuem uma anisotropia magnética transversal. Isto serviu de motivação para a realização de tratamentos termomagnéticos. Os tratamentos foram realizados sob campo magnético transversal de aproximadamente 500 Oe e nas temperaturas de 235, 275, 315 e 350˚C por tempos de 15, 30 e 60 minutos, com um forno construído em laboratório. Isto resultou em melhorias consideráveis na forma de suas curvas ΔE, tornando-as mais assimétricas e aumentando as variações de frequência que estes materiais podem apresentar. Os tratamentos resultaram também em curvas M-H lineares, susceptibilidade magnética constante até a saturação. Foi construída uma bancada para aplicação de tensões de até 30 MPa nas amostras. A maior assimetria das curvas ΔE para o par ressonador e transdutor (partes componentes do sensor de deformação) permitiu maior resposta de variação de frequência de ressonância do sensor durante testes de tração. No melhor dos casos, uma variação de frequência superior a 5 kHz foi detectada para deformações de aproximadamente 260 ppm, ao se utilizar um par ressonador e transdutor de Metglas 2826MB3 tratados termomagneticamente. Medindo-se as curvas ΔE de uma fita de Metglas 2826MB3, tratada, sobre substratos de aço 1010, material magneticamente mole, observou-se que as mesmas ainda estavam presentes. Porém, apresentam sua forma alterada devido à interação com aço. Simulações realizadas com o software FEMM, auxiliaram na compreensão de fenômenos ocorridos nos testes de deformação e na interação entre a fita e os substratos magnéticos moles. / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior, CAPES. / Magnetic amorphous ribbons have a great variety of sensorial applications due to their magnetic properties. The possibility of being remotely queried allows their application in cases where sensors with wired connections present a physical limitation. The capability of acquiring a transverse magnetic anisotropy through thermal treatments, under applied magnetic field and/or stress, is what makes these materials attractive for application in magnetostrictive strain-gauges. The materials studied in this work, Metglas 2826MB3, Yeke 1k501, Yeke 1k501a, Vitrovac 7600, Vitroperm 800 and a commercial EAS Tags, presented magnetization curves with characteristics of materials with reduced transverse magnetic anisotropy. This was the motivation to carry out thermomagnetic treatments. The treatments were carried out under a magnetic field of approximately 500 Oe, using temperatures of 235, 275, 315 and 350˚C, for periods of 15, 30 and 60 minutes, in a home-made oven. The treatments resulted in considerable improvements on the shape of the ΔE curves, making them more asymmetric and increasing the frequency variations that these materials can present. The treatments also resulted in linear M-H curves, with constant magnetic susceptibility until saturation. A system for the application of stresses up to 30 MPa on the samples was built. ΔE curves with greater asymmetry for the pair resonator transducer (components of the strain-gauge) allowed a greater resonance frequency variation response of the sensor during strain tests. In the best case, a frequency variation above 5 kHz was detected for deformations of approximately 260 ppm, when the pair resonator transducer made of thermomagneticaly treated Metglas 2826MB3 was used. The measurements of the ΔE curves of a treated Metglas 2826MB3 ribbon, placed over 1010 steel substrates, soft magnetic material, showed that they were still detectable. However, their form was altered due to the magnetic interaction with the steel. Simulations made using the software FEMM, helped to understand the observed phenomena during the strain tests and the interaction between the ribbon and the soft magnetic substrates.
9

ELECTROPHORETIC CHARACTERISTICS OF CHROMIUM DIOXIDE IN NON-AQUEOUS SOLUTIONS (ZETA POTENTIAL, DISPERSION STABILITY)

Hudson, Guy Frederick, 1962- January 1986 (has links)
No description available.
10

Media fabrication and characterization systems for three dimensional-multilevel magnetic recording

Amos, Nissim. January 2008 (has links)
Thesis (Ph. D.)--University of California, Riverside, 2008. / Includes abstract. Available via ProQuest Digital Dissertations. Title from first page of PDF file (viewed March 10, 2010). Includes bibliographical references (p. 96-104). Also issued in print.