• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • 10
  • 6
  • 4
  • 3
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 231
  • 231
  • 82
  • 64
  • 61
  • 36
  • 34
  • 33
  • 33
  • 32
  • 31
  • 26
  • 24
  • 24
  • 22
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação da radioatividade natural em águas potáveis de superfície e subterrâneas da Região de Caetité, BA / Evaluation of natural radioactivity in superficial and underground drinking water, from the Caetité region, BA

SILVA, LUCIANA S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:22Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:40Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
22

Determinacao de pesticidas piretroides em leite bovino por meio da cromotografia a gas acoplada a espectrometria de massas de armadilha ionica - GC/ITMS ('Ion Trap')

SASSINE, ANDRE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:13Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:36Z (GMT). No. of bitstreams: 1 08283.pdf: 7331635 bytes, checksum: 1c104b9cb00b73030780daec5c1d0c70 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
23

Clonagem, expressão, purificação e caracterização estrutural da região AP-1 da oncoproteína Jun / Cloning, expression, purification and structural evaluation of the region AP-1 oncoprotein Jun

SILVA, FLAVIO S. 10 November 2014 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2014-11-10T11:41:14Z No. of bitstreams: 0 / Made available in DSpace on 2014-11-10T11:41:14Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
24

Otimização da metodologia de preparação do cristal de brometo de tálio para sua aplicação como detector de radiação / Methodology optimization of the thallium bromide crystal preparation for application as a radiation detector

SANTOS, ROBINSON A. dos 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:35Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:07Z (GMT). No. of bitstreams: 0 / Neste trabalho, cristais de TlBr foram crescidos e purificados pelo método de Bridgman Repetido a partir de sais comerciais de TlBr e caracterizados para serem usados como detectores de radiação à temperatura ambiente. Para avaliar a eficiência de purificação, estudos da diminuição da concentração de impurezas foram feitos após cada crescimento, analisando as impurezas traços por Espectrometria de Massas com Plasma (ICP-MS). Um decréscimo significativo da concentração de impurezas em função do número de purificações foi observado. Os cristais crescidos apresentaram boa qualidade cristalina de acordo com os resultados de análise por Difração de Raios X (DRX). Para avaliar os cristais a serem usados como detectores de radiação, medidas de suas resistividades e resposta à incidência de radiação gama da fonte de 241Am (59,5 keV) foram realizadas. Essa resposta foi dependente da pureza do cristal. Um modelo compartimental foi proposto para avaliar as concentrações de impurezas no cristal de TlBr e suas segregações em função do número de crescimentos pelo método de Bridgman. Este modelo compartimental definido por equações diferenciais pode ser usado para calcular o coeficiente de migração das impurezas e mostrou ser útil para prever o número necessário de repetições de crescimento Bridgman para atingir nível de pureza adequado para assegurar a qualidade do cristal como detector de radiação. A diferença dos valores dos coeficientes de migração das impurezas nos cristais entre os sais, de duas procedências diferentes, utilizados foi significativa. Portanto, a escolha do sal de partida deve ser realizada experimentalmente, independente da declaração nominal da sua pureza. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
25

Avaliação da concentração de metais e elementos traço em amostras de sedimento do reservatório Guarapiranga, São Paulo-SP, Brasil / Metal and trace element sediment assessment from Grarapiranga reservoir, Alto Tietê basin, São Paulo, Brasil

GUIMARAES, GUILHERME M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:33:42Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:01Z (GMT). No. of bitstreams: 0 / O reservatório Guarapiranga está localizado na região metropolitana de São Paulo, Brasil, e é responsável pelo abastecimento de cerca de 20% das necessidades de água da população dessa região, aproximadamente 3,7 milhões de pessoas. Contudo, esse sistema tem apresentado significante degradação em sua qualidade de água, devido ao recebimento de esgotos domésticos não tratados e efluentes industriais. Nesse estudo amostras de sedimentos foram coletadas em cinco pontos ao longo do reservatório e a concentração total de alguns elementos maiores (Fe, K e Na), traço (As, Ba, Br, Co, Cr, Cs, Hf, Rb, Sb, Sc, Ta, Tb, Th, U, V e Zn) e terras raras (Ce, Eu, La, Lu, Nd, Sm, Tb e Yb) foram determinadas pela técnica de Análise por Ativação Neutrônica Instrumental (INAA). Utilizando-se a técnica de Espectrometria de Emissão Ótica com Plasma Acoplado Indutivamente (ICP OES) as concentrações dos elementos Al, Ba, Be, Ca, Co, Cr, Cu, Fe, K, Li, Mg, Mn, Na, Ni, Pb, Ti, V e Zn foram determinadas após a digestão ácida dos sedimentos de acordo com a metodologia US EPA 3051. As determinações dos metais Cd e Pb foram feitas por espectrometria de absorção atômica com forno de grafite (GFAAS) e a de Hg total, por espectrometria de absorção atômica com geração de vapor frio (CVAAS). A validação das três metodologias analíticas, em termos de precisão e exatidão, foi feita por meio da análise de materiais de referência certificados. Os resultados obtidos por INAA foram comparados aos valores de referência do NASC (North American Shale Composite), UCC (Upper Continental Crust) e de solos coletados na região do parque da Guarapiranga. O fator de enriquecimento (FE) e o índice de geoacumulação (Igeo) foram calculados para esses dados. As concentrações dos metais obtidos por ICP OES e AAS foram comparadas aos valores orientadores TEL e PEL do Conselho Canadense de Ministros do Meio Ambiente (CCME) e adotados pela CETESB. Os resultados foram também comparados aos valores de referência regionais (VRR) de sedimentos límnicos da Bacia do Alto Tietê. A partir desses dados foi possível realizar uma avaliação do acúmulo de metais e elementos traço nos sedimentos do reservatório e verificar a possibilidade desses elementos interferirem, adversamente, na biota e na qualidade da água desse ambiente. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
26

Analises isotopicas de uranio por espectrometria de massa termoionica

MORAES, NOEMIA M.P. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:30:05Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:20Z (GMT). No. of bitstreams: 1 00488.pdf: 1307796 bytes, checksum: ff2c814dc265e2504b4039389b1fa1f7 (MD5) / Dissertacao (Mestrado) / IEA/D / Instituto de Energia Atomica - IEA
27

Podem ser os metais utilizados no diagnostico do diabetes mellitus tipo 2? / Can metals be used in to diagnose of type 2 diabetes?

MULLER, RENATA M.L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:37Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:03Z (GMT). No. of bitstreams: 0 / A prevalência do diabetes mellitus está aumentando de forma exponencial, adquirindo características epidêmicas em vários países. Nos países em desenvolvimento, particularmente, constitui-se de um grave problema de saúde pública. Dessa forma, o desenvolvimento de novas metodologias que auxiliem no diagnóstico e controle de doenças traz uma importante contribuição não somente ao tratamento de pacientes portadores desta doença como também no estabelecimento de políticas públicas de prevenção da mesma. A presença dos metais em amostras de soro humano tem sido utilizada por diversos autores para o diagnóstico da doença. Entretanto sua interpretação constitui-se ainda um desafio. A principal razão para esta dificuldade consiste no fato de que, na maioria dos estudos encontrados na literatura, o nível de metais tanto nos pacientes como no grupo de controle estão, muitas vezes, na mesma faixa de distribuição. Neste estudo, é discutida uma nova abordagem para a interpretação dos níveis de metais em amostras de soro de indivíduos portadores de diabetes mellitus tipo 2 e a possibilidade de sua utilização no diagnóstico da doença. Foram recrutados pelo Hospital da Universidade Federal de Juiz de Fora, 86 sujeitos com diabetes mellitus tipo 2 e 67 sujeitos controle. As amostras de sangue foram colhidas para separar o soro. Os elementos Cu, Mg, Mn, Se, V e Zn foram determinados pela da técnica de espectrometria de massa de alta resolução com fonte de plasma indutivamente acoplado. A interpretação dos dados foi realizada utilizando-se as técnicas de análise discriminante, componentes principais e de cluster. O conteúdo de metais nas amostras analisadas foi concordante com os dados da literatura. No entanto, a principal conclusão deste estudo é que as concentrações de cada elemento, por si mesmas, não podem ser utilizadas no diagnóstico de diabetes mellitus. Porém, a determinação de todos os metais associados à doença e a utilização de técnicas estatísticas multivariadas podem proporcionar uma excelente alternativa para esta avaliação. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
28

Razão isotópica de enxofre em material atmosférico por ICPMS de alta resolução

FURUSAWA, HELIO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:07Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:24Z (GMT). No. of bitstreams: 1 12435.pdf: 4820144 bytes, checksum: 0d8279d9b23571886f63adee62a8b6f4 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Quimica, Universidade de Sao Paulo - IQ/USP
29

Dissolucão eletrolítica de ligas de alumínio em cavacos e determinação dos elementos constituintes por espectrometria de emissão atômica com fonte de plasma (ICP-OES)

GRIGOLETTO, TANIA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:14Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:24Z (GMT). No. of bitstreams: 1 12433.pdf: 20959730 bytes, checksum: a98e9829a642f5e597da179c95c176ef (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Quimica, Universidade de Sao Paulo - IQ/USP
30

Avaliação da radioatividade natural em águas potáveis de superfície e subterrâneas da Região de Caetité, BA / Evaluation of natural radioactivity in superficial and underground drinking water, from the Caetité region, BA

SILVA, LUCIANA S. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:34:22Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:40Z (GMT). No. of bitstreams: 0 / O Brasil possui a sétima maior reserva geológica de urânio do mundo, com aproximadamente 310 mil toneladas. A Província Uranífera de Lagoa Real, na região de Caetité e Lagoa Real, situado no centro sul da Bahia, é considerada a mais importante província monominerálica do Brasil. A população urbana que vive no distrito uranífero nas cidades de Caetité, Lagoa Real e Livramento de Nossa Senhora usa água potável oriunda do abastecimento público. Na área rural, caracterizada por freqüentes secas, os moradores recebem água de poços escavados e perfurados como também, de pequenas barragens e reservatórios abastecidos pelas chuvas. Este trabalho determinou os níveis de radioatividade alfa e beta total e as concentrações de urânio em diversos tipos de água consumidas pela população urbana e rural da Província Uranífera de Lagoa Real. As atividades α e β total foram determinadas com detector proporcional de fluxo gasoso e baixa radiação de fundo. As concentrações de urânio foram determinadas com o Espectrômetro de Massa com Fonte de Plasma Indutivo (ICP-MS). Os resultados obtidos foram comparados com as recomendações recentes de 2011 da Organização Mundial da Saúde, a portaria nº 2914 de 12/12/2011 do Ministério da Saúde e as resoluções do CONAMA. Os níveis de radiação natural variaram de 0,0041 ± 0,0004 Bq.L-1 a 0,80 ± 0,04 Bq.L-1 para a atividade alfa total e de 0,045 ± 0,003 a 3,0 ± 0,2 Bq.L-1 para a atividade beta total. Tendo como parâmetro a OMS e o MS, apenas duas amostras de água subterrânea, uma localizada na cidade de Lagoa Real e outra na cidade de Caetité apresentaram concentrações alfa total acima do valor de 0,5 Bq.L-1 descrito em suas recomendações, 0,80 ± 0,04 Bq.L-1 e 0,57 ± 0,03 Bq.L-1respectivamente. Para beta total, três amostras apresentaram níveis de radioatividade acima do limite de 1 Bq.L-1 recomendado pela Organização Mundial de Saúde e estabelecido pelo Ministério da Saúde; 3,0 ± 0,2 Bq.L-1; 1,63 ± 0,13 Bq.L-1 e 1,19 ± 0,07 Bq.L-1 todos situados no município de Lagoa Real. Duas amostras de água subterrânea no município de Caetité apresentaram concentrações de urânio acima do valor de 15 μg.L-1 determinado pelo CONAMA, 20,3 ± 0,3 μg.L-1 e 17,1± 0,3 μg.L-1. Em Lagoa Real, uma amostra apresentou níveis de urânio seis vezes superior ao limite estabelecido pelo Conselho Nacional de Meio Ambiente, 89,5 ± 1,5 μg.L-1. A Organização Mundial da Saúde em 2004 estabeleceu em suas recomendações o limite de 15 μg.L-1 como a concentração máxima de urânio na água potável. Em 2011 a OMS aumentou este limite para 30 μg.L-1. Levando-se em consideração as atuais recomendações da OMS, apenas a concentração de uma amostra de água apresentou níveis de urânio acima do recomendado, 89,5 ± 1,5 μg.L-1 no município de Lagoa Real. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0749 seconds