• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

CONTRIBUIÇÃO TERMO-ENERGÉTICA DOS FECHAMENTOS TRANSPARENTES EM EDIFÍCIOS COMERCIAIS CLIMATIZADOS ARTIFICALMENTE EM SANTA MARIA-RS / THERMAL ENERGY CONTRIBUTION TO TRANSPARENT CLOSURE IN ARTIFICIALLY CONDITIONED COMMERCIAL BUILDINGS IN SANTA MARIA-RS

Zófoli, Giana da Rocha 13 December 2011 (has links)
This paper analyzes the influence of the penetration of solar radiation through the transparent closure in consumption of energy for conditioning of the office buildings in the region of Santa Maria-RS, located in the bioclimatic Brazilian zone 2. To do this, simulations were performed in the computational program Design Builder, in a typical office environment in order to evaluate the comparative results obtained with the use of different types of glass (Solar Factor) by different percentages of area of windows and surface guidelines. The glasses used had solar factor ranging from 0.85, 0.70, 0.56 and 0.29, an opening percentage area of 20%, 50% and 80%, while the solar orientation ranged from 0° to 315° at an interval of 45°. It was observed that for the climate of the city of Santa Maria-RS, considering the daytime use of the building, the consumption of energy for cooling process has higher values compared to the heating and that this difference is directly proportional to the solar factor of the glass and the percentage of openings in the facade. Changes that contribute to a reduction of one of these lead to an increased consumption of the other, these should be analyzed jointly in the process of defining the openings, in order to obtain the lowest annual energy consumption. The simulations indicated higher expenditure of energy with heating on the facades oriented to the south, southeast, and southwest, while the higher cost for cooling occurred on facades oriented to the north, northeast, northwest, regardless of the solar factor or percentages of openings in façade. It was observed that, when established constructive guidelines regarding apertures in construction performance standards for buildings, should be considered together the percentage of area openings, Factor Solar glass and solar orientation of the facade, as the exchanges of heat and entry lighting are naturally associated with these factors in an integrated manner. / Este trabalho analisa a influência da radiação solar que penetra pelos fechamentos transparentes no consumo de energia para climatização de edifícios de escritório na região de Santa Maria RS, situado na zona bioclimática 2 brasileira. Para isso, foram realizadas simulações no programa computacional Design Builder, em um ambiente típico de escritório, visando avaliar comparativamente os resultados obtidos com o uso de diferentes tipos de vidro (Fator Solar), mediante diferentes percentuais de área de janelas e orientações de fachada. Os vidros utilizados têm valores de Fator Solar variando de 0.85, 0.70, 0.56 e 0.29, o percentual de área de abertura de 20%, 50% e 80%, enquanto a orientação solar variou de 0° a 315°, com intervalo de 45°. Foi observado, para o clima da cidade de Santa Maria-RS, considerando-se o uso diurno do edifício, que o consumo de energia para resfriamento apresenta valores mais elevados em relação ao aquecimento, e que esta diferença é diretamente proporcional ao Fator Solar do vidro e ao percentual de aberturas na fachada. Mudanças que colaboram para a redução de um destes consumos levam ao aumento do outro, devendo-se analisá-los de forma conjunta, no processo de definição das aberturas, para que se obtenha o menor consumo anual de energia. As simulações indicaram maiores gastos de energia com aquecimento nas fachadas orientadas para sul, sudeste e sudoeste, enquanto os maiores gastos com resfriamento ocorrem com fachadas orientadas a norte, nordeste e noroeste, independente do Fator Solar do vidro ou do percentual de aberturas na fachada. Foi observado que, ao serem estabelecidas diretrizes construtivas referentes a aberturas em normas de desempenho de edificações, devem ser considerados conjuntamente o percentual de área de aberturas, o Fator Solar do vidro e a orientação solar da fachada, pois as trocas de calor e entrada de iluminação natural estão associadas a estes fatores de forma integrada.

Page generated in 0.1091 seconds