• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • 28
  • 14
  • 6
  • 4
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 162
  • 162
  • 35
  • 28
  • 27
  • 26
  • 25
  • 22
  • 21
  • 20
  • 19
  • 18
  • 18
  • 17
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
81

Desenvolvimento de uma metodologia de avaliação de medidores portáteis de radiação em altas taxas de kerma no ar / Development of a methodology of portable radiation meters at high rates of air

DAMATTO, WILLIAN B. 08 April 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-04-08T12:38:10Z No. of bitstreams: 0 / Made available in DSpace on 2016-04-08T12:38:10Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
82

Sensor de nível tipo deslocador com autocompensação da densidade do líquido / A displacer-type liquid level sensor with density autocompensation

Souza, Matheus Oliveira 17 August 2018 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Level measurement plays a crucial role in a wide range of scientific and industrial applications, such as agriculture, hydrology, soil science, oil, pharmaceutical and food industries, among others. Due to the need of measuring level in different environments and for different liquids, granulated solids or powder, several sensors have been proposed to this end, for example, capacitive, infrared, hydrostatic, ultrasonic, radar, laser, optical, displacer, among others, each having its pros and cons. In particular, displacer-type level sensors are highly linear, precise and exact for a given working condition, in addition to having low cost and being easily installed. However, these sensors estimate liquid level indirectly by measuring the buoyancy forces on a displacer connected to a strain gauge, which makes it highly sensitive to variations in liquid density. As a consequence, it is also sensitive to variations in the liquid temperature, since the density is sensitive to temperature. This makes displacer level sensors unfeasible in industrial applications that do not keep such quantities in a range tight enough to ensure low measurement errors (e.g., oil, food and pharmaceutical industries). As a way to allow for the use of displacer-type level sensors in industrial applications, it is proposed in this work and it was also built a new displacer-type liquid level sensor self-compensating for liquid density. The proposed method uses the ratio between the buoyancy forces measured by two displacers and two load cells to make it density independent and, as a consequence, temperature invariant. Such characteristic is observed in the simulations results. The prototype experimental results show that the system has high linearity, it is able to mitigate the sensitivity to the density of the measurand, and it has potential to make precise measurements. / A medição de nível desempenha um papel crucial em várias aplicações industriais e científicas, tais como produção e refino do petróleo, agricultura, hidrologia, ciências do solo, indústrias alimentícias, indústrias farmacêuticas, dentre outras. Devido à necessidade de mensurar nível em ambientes distintos e para diferentes líquidos, sólidos granulados ou pó, vários sensores de nível têm sido desenvolvidos, por exemplo, o sensor capacitivo, infravermelho, hidrostático, ultrassônico, radar, laser, óptico, deslocador, dentre outros. Cada um com suas vantagens e desvantagens. Em particular, o sensor de nível tipo deslocador tem alta linearidade, precisão e exatidão, além de ser uma tecnologia de baixo custo e instalação simples. Entretanto, esse tipo de sensor estima o nível indiretamente medindo a força empuxo em um deslocador conectado a uma célula de carga, o que o torna muito sensível a variações na densidade do líquido. Como consequência, o mesmo também é sensível a variações na temperatura do líquido, pois a densidade é sensível à temperatura. Isso inviabiliza a aplicação dessa tecnologia em atividades que a densidade ou a temperatura do líquido não é mantida em uma faixa pequena de variação, como nas indústrias farmacêuticas, alimentícias e petrolíferas. Para viabilizar a aplicação do sensor de nível tipo deslocador em tais atividades, neste trabalho é proposto e construído um sensor de nível tipo deslocador com autocompensação da densidade do líquido. O método proposto usa a relação entre as forças de empuxo medidas por dois deslocadores e duas células de carga para tornar o sensor idealmente insensível às variações na densidade do líquido e, como consequência, insensível a variações na temperatura do líquido. Tal característica é observada nos resultados por simulação. Os resultados dos experimentos realizados com o protótipo mostram que o sistema tem alta linearidade, é capaz de mitigar a sensibilidade à densidade do líquido e tem potencial para fazer medições precisas. / São Cristóvão, SE
83

Metodologia de controle de qualidade e implantacao de campos padroes de radiacao X, nivel mamografia, seguindo a norma IEC 61267 / Quality control methodology and implementation of X-radiation standards beams, mammography level, following the standard IEC 61267

CORREA, EDUARDO de L. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:32Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:01Z (GMT). No. of bitstreams: 0 / Neste trabalho foi desenvolvido e aplicado um programa de controle de qualidade ao equipamento de raios X (160 kV, potencial constante, alvo de tungstênio) do Laboratório de Calibração de Instrumentos (LCI) do IPEN no intervalo de energia relativo aos feixes de mamografia (de 25 a 35 kV). Depois da aplicação deste programa foram implantados os campos padrões de radiação X, nível mamografia, utilizando filtração adicional de molibdênio e alumínio, seguindo recomendações nacionais e internacionais, neste mesmo equipamento. A câmara de ionização de referência possui rastreabilidade ao PTB e foi submetida rotineiramente a testes de controle de qualidade para avaliação e análise da confiabilidade de seu desempenho. Foram implantadas qualidades relativas aos feixes de entrada (RQR-M), feixes de saída (RQA-M), feixes estreitos (RQN-M) e feixes largos (RQB-M), seguindo as recomendações da nova norma internacional IEC 61267, de 2005 e do novo código de pratica da AIEA, TRS 457 (2007). Para a implantação dos feixes RQN-M e RQB-M foram desenvolvidos dois simuladores específicos para mamografia. As camadas semi-redutoras encontradas são aquelas apresentadas pelo laboratório primário alemão PTB, e variaram de 0,35 até 1,21 mmAl. As taxas de kerma no ar foram determinadas para todas as 15 qualidades implantadas. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
84

Avaliação da grandeza tensão de pico prática em equipamentos clínicos utilizados em radiodiagnóstico

PIRES, JOAO dos S.J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:03Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:56Z (GMT). No. of bitstreams: 1 12869.pdf: 4811202 bytes, checksum: 0173b38520efa5ad7a157158292d063c (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
85

Desenvolvimento de uma metodologia para a calibracao de instrumentos de medida utilizados no controle de qualidade em radiodiagnostico intervencional / Development of a calibration methodology for instruments used to interventional radiology quality control

MIRANDA, JUREMA A. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:34Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:06:29Z (GMT). No. of bitstreams: 0 / Radiologia intervencional é a prática na qual imagens geradas por radiação-X são usadas como uma ferramenta na condução de procedimentos diagnósticos - terapêuticos. Tanto nos procedimentos para diagnósticos como nos terapêuticos, os tempos de exposição são longos, podendo causar graves lesões no paciente, e contribuindo para a dose espalhada no corpo clínico. O Brasil ainda não possui regras bem definidas quanto às doses e dosimetria de feixes fluoroscópicos. Há um grande interesse no estudo destes feixes, quanto a qualidade do feixe, camada-semi-redutora, entre outros parâmetros. Neste trabalho foi desenvolvida uma metodologia para a calibração de instrumentos de medida utilizados no controle de qualidade em radiodiagnóstico intervencional utilizando um sistema de radiação X clínico Medicor Neo Diagnomax, no modo fluoroscópico. Foi utilizada uma câmara de ionização plana marca PTW como monitora. Algumas câmaras de ionização recomendadas para fluoroscopia foram avaliadas e calibradas em relação à câmara de ionização de referência do laboratório de calibração do IPEN. Foram implantadas as qualidades de radiação RQR3, RQR5 e RQR7 e as específicas para a fluoroscopia RQC3, RQC5 e RQC7 seguindo as recomendações da norma IEC 61267. Todas as características dos feixes foram determinadas. Para a realização deste trabalho foi construído um sistema de posicionamento de câmaras de ionização. Para a determinação de dose de entrada e saída do paciente e de radiação espalhada na posição do corpo clínico, foram construídos simuladores de acrílico. Os resultados obtidos mostram uma taxa de Kerma de entrada no simulador de 4,5 x10-3, 1,2 x10-2 e 1,9 x 10-2 Gy/min para RQC 3, RQC 5, RQC 7 respectivamente. Foram realizados testes sem e com a colimação posicionada entre a câmara monitora e o simulador e os resultados encontrados mostram uma diferença de +5,5%, +0,6% e +0,8 %. Comprovando a importância da colimação nestes procedimentos intervencionistas. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
86

Metodologia de controle de qualidade de equipamentos de raios x (nivel diagnostico) utilizados em calibracao de instrumentos

ROS, RENATO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:11Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:52Z (GMT). No. of bitstreams: 1 07071.pdf: 5827883 bytes, checksum: 3d1bd075be2e6283f7d961fc597f6d59 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
87

Padronização dos radionuclídeos sup(201)Ti e sup(55)Fe em sistema de consciências 4`pi`(PC)-Nal(Ti) / Standardization of 201Ti and 55Fe radionuclides in a 4(PC)-Nal(Ti) coincidence system

PIRES, CARLOS A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:07:47Z (GMT). No. of bitstreams: 0 / No presente trabalho foi desenvolvido o método de padronização de radionuclídeos produzidos em cíclotrons utilizando o sistema de coincidências 4(PC)-NaI(Tl) composto de um contador proporcional operando a 0,1 MPa. Os radionuclídeos selecionados, foram o 201Tl, de uso em medicina nuclear e o 55Fe padrão primário muito utilizado na calibração de espectrômetros de raios-x. O 201Tl desintegra pelo processo de captura eletrônica, seguido pela emissão de radiação gama. A taxa de desintegração foi determinada pela técnica de extrapolação linear da eficiência empregando dois métodos: discriminação eletrônica e absorvedores externos. As fonte radioativas foram preparadas em substratos de Collodion com espessura de 20 g cm-2. O sistema eletrônico utilizado é o convencional para este tipo de medida. Os eventos observados foram registrados empregando o método TAC. O 55Fe desintegra pelo processo de captura eletrônica decaindo diretamente para o estado fundamental do 54Mn, emitindo raios-x com aproximadamente 6 keV. A taxa de desintegração foi determinada pelo método do traçador. Esta técnica foi aplicada utilizando dois radionuclídeos traçadores, que decaem pelo processo de captura eletrônica seguido da emissão de fótons, são eles 51Cr e 54Mn. As medidas foram feitas com 1 e 2 absorvedores de Al com espessura de 150 g cm-2. A atividade foi obtida extrapolando para zero espessura de Al. As incertezas envolvidas e suas correlações foram analisadas seguindo a metodologia de matriz de covariâncias. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP
88

Estabelecimentos de campos padroes de raios-x de energias baixas, nivel de radioprotecao, para calibracao de instrumentos

OLIVEIRA, ELIANE C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:51Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:16Z (GMT). No. of bitstreams: 1 04995.pdf: 5445247 bytes, checksum: 94d30480189048c6bb746a9db426ad86 (MD5) / Dissertacao(Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
89

Automatizacao de um sistema de medidas de correntes produzidas por camaras de ionizacao e aplicacao na calibracao do sup(18) F e sup(153) Sm

BRANCACCIO, FRANCO 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:08Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:47Z (GMT). No. of bitstreams: 1 07921.pdf: 513900 bytes, checksum: 78943492794157b921a0e2b609b7627b (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
90

Desenvolvimento do processo de deposicao eletroforetica de boro em substratos de aluminio destinados a construcao de detectores de neutrons

SAMPA, MARIA H. de O. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:32:32Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:09Z (GMT). No. of bitstreams: 1 03259.pdf: 2834364 bytes, checksum: fcbdf9e370a39ffdb27be573e65f253c (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP

Page generated in 0.0925 seconds