Spelling suggestions: "subject:"mecanismos dde transferência"" "subject:"mecanismos dee transferência""
1 |
Transferência dos esforços cisalhantes em juntas de pavimentos rígidos / Transfer of shear strength in joints of rigid pavementsOliveira , Elisandra Miranda de 17 September 2008 (has links)
Submitted by Luciana Ferreira (lucgeral@gmail.com) on 2017-01-26T10:17:46Z
No. of bitstreams: 2
Dissertação - Elisandra Miranda de Oliveira - 2008.pdf: 8045679 bytes, checksum: bbc3ccef6840ca7cc9f60fd22a61ed85 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-01-26T10:18:11Z (GMT) No. of bitstreams: 2
Dissertação - Elisandra Miranda de Oliveira - 2008.pdf: 8045679 bytes, checksum: bbc3ccef6840ca7cc9f60fd22a61ed85 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-01-26T10:18:12Z (GMT). No. of bitstreams: 2
Dissertação - Elisandra Miranda de Oliveira - 2008.pdf: 8045679 bytes, checksum: bbc3ccef6840ca7cc9f60fd22a61ed85 (MD5)
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Previous issue date: 2008-09-17 / Conselho Nacional de Pesquisa e Desenvolvimento Científico e Tecnológico - CNPq / The joint is part of the constructive process of the rigid pavement. In its implementation the section of concrete located below it is weakened and eventually becoming the most vulnerable of the pavement can arise where the possible diseases that may affect their strength and durability. Despite the importance that the joint has in the life of the rigid pavement it is not exploited, and therefore became the main subject of this study. This work is an experimental study of the sawed joint in rigid pavement of concrete with evaluation of the transference of shear strength through the saweds joints. The experimental program consisted of test of fourteen simple concrete plates with sawed joint, and adoption of the following variable: presence of smooth dowel of Ø 12,5mm, variation of the length of dowel (500 mm, 400 mm and 300 mm), variation of the thickness of the plates (120 mm and 160 mm), variation of the strength to the compression of the concrete (20 MPa and 30 MPa) and of the type of used concrete (conventional and autoadensável). These plates had been supported on natural and assayed rubber layers with static shipment application in one of the sides of the together one until the rupture of the plate. The results had shown that: the use of dowel
in these meetings increases the efficiency in the transference of efforts; the increase in the thickness of the plate increases the resistant capacity of the together one, the efficiency in the transference of efforts and possesss minors displacements of the plate during the application of the shipment; the dowel with reduced size are efficient, but the bars of 400 mm present resulted next to the one to the bar in commercial size, 500 mm; the plates in autoadensável concrete after the fissuration practically do not present contribution of the concrete in the transference of efforts for the intertravamento of aggregates; the sawed joint depth of the together one has influence in the way of rupture of the plate and tack relation enters the bar of transference and concret. / A junta faz parte do processo construtivo do pavimento de concreto. Na sua execução a seção de concreto localizada abaixo dela fica enfraquecida e acaba se tornando o ponto mais vulnerável do pavimento onde podem surgir as possíveis patologias que venham a afetar a sua resistência e
durabilidade. Apesar da importância que a junta possui na vida útil do pavimento de concreto este assunto é pouco explorado, e por isso se tornou o objeto principal deste estudo. Este trabalho é um estudo experimental das juntas serradas em pavimento rígido de concreto com avaliação da transferência de esforços cisalhantes através das juntas serradas. O programa experimental constou de ensaios de quatorze placas em concreto simples com junta serrada, e adoção das seguintes variáveis: presença de barra de transferência lisa de Ø 12,5mm, variação do comprimento das barras de transferência (500 mm, 400 mm e 300 mm), variação da espessura das placas (120 mm e 160 mm), variação da resistência característica à compressão do concreto (20 MPa e 30 MPa) e do tipo de concreto utilizado (convencional e autoadensável). Essas placas foram apoiadas sobre camadas de borracha natural e ensaiadas com aplicação de carregamento estático em um dos lados da junta até a ruptura da placa. Os resultados mostraram que: o uso de barras de transferência nessas juntas aumenta a eficiência na transferência de esforços; o aumento na espessura da placa aumenta a capacidade resistente da junta, a eficiência na transferência de esforços e possuem menores deslocamentos da placa durante a aplicação do carregamento; as barras com tamanho reduzido são eficientes, mas as barras de 400 mm apresentam resultados próximos ao da barra em tamanho comercial, 500 mm; as placas em concreto autoadensável após a fissuração praticamente não apresentam contribuição do concreto na transferência de esforços pelo intertravamento dos agregados; a profundidade da junta serrada tem influência no modo de ruptura da placa e relação de aderência entre a barra de transferência e o concreto.
|
Page generated in 0.0952 seconds