Herons ångkula : Bestämning av verkningsgrad

Hermansen, Johan January 2008 (has links)
<p>Detta arbete beskriver hur Herons ångkula fungerar och hur den har byggts.</p><p>Ånkulan konstruerades för ca 2000 år av Heron.</p><p>Meningen var att få fram en verkningsgrad eftersom denna var okänd. Verkningsgraden blev aldrig konstaterad. Endast en teoretisk beräkning för verkningsgraden gjordes. Kulan sattes inte i rotation av ångtrycket som byggdes upp när det eldades under denna.</p><p>Anledningen var troligen att det var för mycket friktion i tätningen som skulle tillföra matarvatten in i kulan. Värmeöverföringen mellan gaslågan och kulkroppen var inte heller den mest optimala.</p><p>Kulan med tillhörande kringutrustning byggdes under dec-07/jan-08 efter eget tycke och utan någon existerande ritning. Den byggdes för att efterlikna originalet så mycket som möjligt. Dessutom hade en mindre ångkula byggts några år tidigare och denna hade visat sig fungera. Denna något större ångkula fick därför samma utseende.</p><p>Eftersom ångkulan inte orkade rotera råder det inga tvivel om hur ineffektiv denna tidiga reaktionsmotorn är.</p><p>Den fick ingen praktisk betydelse för 2000 år sedan, och det har den inte idag heller.</p><p>En framräknad verkningsgrad finns redovisad och denna blev mycket låg.</p><p>Det var stimulerandel att bygga Herons ångkula men konstruktionen i sig tillhör inte de mest lyckade.</p> / <p>This work describes how the Herons steam ball was built and how it works. It was constructed by Heron 2000 years ago. The purpose was to determine the efficiency of the steam ball because it was unknown. The efficiency was never determined. It was only theoretically determined by calculations. The steam pressure never gave the steam ball rotation when heat was added underneath the construction. A possible reason was that friction in the sealing for supplying feed water into the steam ball was too high.</p><p>The heat transfer was also a reason that the construction did not rotate.</p><p>The steam ball and necessary equipment was fabricated in dec-07/jan-08. It was built without any drawings. The goal was to make it look like the original as much as possible. A smaller steam ball was built some years before. This one did rotate and therefore was the same design given to the bigger one.</p><p>Because of the lack of rotation there was no doubt if the steam ball was a sucsess or not.</p><p>It was not used for any real purpose 2000 years ago and this has not changed.</p><p>A calculated figure of the efficiency was documented in this rapport, and it was very low.</p><p>It was amusing to design and build the steam ball but the construction was clearly no success.</p>
2

Herons ångkula : Bestämning av verkningsgrad

Hermansen, Johan January 2008 (has links)
Detta arbete beskriver hur Herons ångkula fungerar och hur den har byggts. Ånkulan konstruerades för ca 2000 år av Heron. Meningen var att få fram en verkningsgrad eftersom denna var okänd. Verkningsgraden blev aldrig konstaterad. Endast en teoretisk beräkning för verkningsgraden gjordes. Kulan sattes inte i rotation av ångtrycket som byggdes upp när det eldades under denna. Anledningen var troligen att det var för mycket friktion i tätningen som skulle tillföra matarvatten in i kulan. Värmeöverföringen mellan gaslågan och kulkroppen var inte heller den mest optimala. Kulan med tillhörande kringutrustning byggdes under dec-07/jan-08 efter eget tycke och utan någon existerande ritning. Den byggdes för att efterlikna originalet så mycket som möjligt. Dessutom hade en mindre ångkula byggts några år tidigare och denna hade visat sig fungera. Denna något större ångkula fick därför samma utseende. Eftersom ångkulan inte orkade rotera råder det inga tvivel om hur ineffektiv denna tidiga reaktionsmotorn är. Den fick ingen praktisk betydelse för 2000 år sedan, och det har den inte idag heller. En framräknad verkningsgrad finns redovisad och denna blev mycket låg. Det var stimulerandel att bygga Herons ångkula men konstruktionen i sig tillhör inte de mest lyckade. / This work describes how the Herons steam ball was built and how it works. It was constructed by Heron 2000 years ago. The purpose was to determine the efficiency of the steam ball because it was unknown. The efficiency was never determined. It was only theoretically determined by calculations. The steam pressure never gave the steam ball rotation when heat was added underneath the construction. A possible reason was that friction in the sealing for supplying feed water into the steam ball was too high. The heat transfer was also a reason that the construction did not rotate. The steam ball and necessary equipment was fabricated in dec-07/jan-08. It was built without any drawings. The goal was to make it look like the original as much as possible. A smaller steam ball was built some years before. This one did rotate and therefore was the same design given to the bigger one. Because of the lack of rotation there was no doubt if the steam ball was a sucsess or not. It was not used for any real purpose 2000 years ago and this has not changed. A calculated figure of the efficiency was documented in this rapport, and it was very low. It was amusing to design and build the steam ball but the construction was clearly no success.
3

Measuring and Predicting Transient Diesel Engine Emissions

Westlund, Anders January 2009 (has links)
<p> </p><p>Due to its impact on human health and the nature surrounding us, diesel engine emissions have been significantly reduced over the last two decades. This reduction has been enforced by the legislating organs around the world that gradually have made the manufacturers transform their engines to today’s complex high-tech products. One of the most challenging areas to meet the legislations is transient operation where the inertia in gas-exchange system makes transition from one load to another problematic.</p><p> </p><p>Modern engines have great potential to minimize the problems associated with transient operation. However, their complexity also imposes a great challenge regarding optimization and systematical testing of transient control strategies in an engine test bed could be both expensive and time consuming.</p><p> </p><p>The objective of this project is to facilitate optimization of transient control strategies. This should be done by identifying appropriate measurement methods for evaluation of transients and by providing models that can be used to optimize strategies off-line.</p><p> </p><p>Measurement methods for evaluation of transients have been tested in several experiments, mainly focusing on emission but also regarding e.g. EGR flow. Applicable instruments for transient emission measurements have been identified and used. However, no method to measure soot emissions cycle resolved has yet been found. Other measurements such as EGR flow and temperatures are believed to have significantly decreased accuracy during transients.</p><p> </p><p>A model for prediction of NOx emissions have been used and complemented with a new approach for soot emission predictions that has been developed in this project. The emission models have been shown to be applicable over a wide range of operating conditions with exception for highly premixed combustion. It has also been shown that models developed for steady state conditions can be used for transients operation.</p>
4

Samkörning mellan värmepumpar och fjärrvärme : Bostadsrättsföreningen Bogården

Sadik, Zidar January 2008 (has links)
<p>This diploma work covers an investigation over the heat - and hot water systems of the</p><p>tenant-owner's association, Bogården. The heat - and hot water needs of Bogården are</p><p>satisfied by both district heating as well as three heat pumps. Implemented investigation</p><p>shows that the heat pumps are not used in a profitable way. Apart from that, the reserve</p><p>possibilities are small. There is also a risk of the growth of Legionella bacterium in the</p><p>hot water system.</p><p>Since the heat pumps are already installed, HSB-Gävleborg (responsible for Bogården)</p><p>has a wish to investigate possible proposed actions for optimization of existing plant.</p><p>After completed investigation, a new proposed action is presented. The new proposed</p><p>action goes on intercepting the hot water production and using the heat pumps to only</p><p>heat production during the heating season. Why the hot water production should be</p><p>intercepted, is just in order to eliminate the risk of Legionella. Besides, the new proposal</p><p>is going to bring about a reserve of 1,534,000 SEK during a twenty-year period. This is</p><p>approximately twice as much as what the existing plant may bring during the same</p><p>period.</p><p>During the work's review, it also has been established that heat - and hot water systems</p><p>are error regulated. Since the diploma work does not cover that piece it is instead</p><p>informed as proposals subject to further investigation.</p>
5

Comparative study of residue pellets from cane sugar and palm-oil industries with commercial wood pellets, applied in downdraft gasification

Erlich, Catharina January 2009 (has links)
While biomass utilization for energy conversion in the industrialized nations is being largely developed, highly efficient and environmentally friendly, many tropical countries still use biomass at low efficiencies and high emission levels. The main reasons for these gaps are both political and technological: the energy markets are different, the Gross National Product (GDP) differs widely, and the feedstock differs in form and conversion behaviour. By implementing newer technologies adapted for tropical biomass feedstock, there would be a large potential in these countries for increased energy services since access to modern energy still is an essential step for improving the GDP for a country. Two dominant and tropically placed industries available for energy improvements are the cane sugar and palm-oil industries, which both produce an abundant amount of biomass residues. One step towards enhanced utilization of the residues, which would not require large investment costs in the power plant section nor in the processes of these industries, would be to install a pelletizing unit in the industry area to make fuel out of the excess residues for sale to the nearby villages. The pellets could be used both for cooking/heating and for small-scale power generation in a gasification-IC engine plant. The overall objective of this study is to experimentally evaluate the biomass residues in pellet form from the cane sugar and palm oil industries during conversion to useful energy in small-scale systems. The thesis is built upon five publications which include experimental analysis on flaming pyrolysis and rapid heating of pellets (paper I), pyrolysis in oxygen-free atmosphere and slow heating with subsequent steam gasification (paper II), global pelletizing data such as relative energy consumption, temperature levels, particle size and moisture content for successful pelletizing process (paper III), downdraft gasification evaluation including reactor temperature distribution, gas composition, cold-gas efficiency and packed-bed mechanics (paper IV) and a numerical model including the overall system efficiency for residue-to-electric power based in a small-scale gasifier system (paper V).The single-pellet studies revealed that pyrolysis in reducing atmosphere is to prefer compared to flaming pyrolysis in oxidizing environment with regards to the char quality. The studies also showed favourable thermochemical and mechanical behaviour for smaller size pellets (Ø6- Ø8mm) compared to larger size ones (Ø12 mm). Therefore, a downdraft gasifier of closed constricted type was designed for real gasification tests of the residue pellets of sizes Ø6- Ø8mm. These tests showed that all the studied pellet sorts could be used in one and the same gasifier, resulting in different reactor temperature distributions and gas compositions with lower heating values in the range of 4.1-5.4 MJ/m3n dry gas. The reactor bed dynamics showed to be dependent both on the fuel reactivity and the size, with less pressure drop for larger size pellets with lower reactivity. The pelletizing process itself revealed that the selected residues all needed higher moisture content and smaller particle size than recommended for wood for successful pelletizing. The relative electric energy consumption was lower when producing larger size pellets Ø8 mm than smaller ones (Ø6 mm) of same material. For untreated wet empty-fruit bunch (EFB) a stand-alone power plant with integrated EFB pre-treatment and gasification could generate 380 kWh of net electricity per ton of EFB at a “well-to-wheel” efficiency of 15%. / QC 20100712
6

Samkörning mellan värmepumpar och fjärrvärme : Bostadsrättsföreningen Bogården

Sadik, Zidar January 2008 (has links)
This diploma work covers an investigation over the heat - and hot water systems of the tenant-owner's association, Bogården. The heat - and hot water needs of Bogården are satisfied by both district heating as well as three heat pumps. Implemented investigation shows that the heat pumps are not used in a profitable way. Apart from that, the reserve possibilities are small. There is also a risk of the growth of Legionella bacterium in the hot water system. Since the heat pumps are already installed, HSB-Gävleborg (responsible for Bogården) has a wish to investigate possible proposed actions for optimization of existing plant. After completed investigation, a new proposed action is presented. The new proposed action goes on intercepting the hot water production and using the heat pumps to only heat production during the heating season. Why the hot water production should be intercepted, is just in order to eliminate the risk of Legionella. Besides, the new proposal is going to bring about a reserve of 1,534,000 SEK during a twenty-year period. This is approximately twice as much as what the existing plant may bring during the same period. During the work's review, it also has been established that heat - and hot water systems are error regulated. Since the diploma work does not cover that piece it is instead informed as proposals subject to further investigation.
7

Inverkan av värme på lagerlägets cylindricitet i ett lagerhus

de Vries, Frank January 2010 (has links)
Det här examensarbetet har utförts hos och med stöd av SKF Mekan i Katrineholm. Grundfrågeställningen som innebar upphovet till examensarbetet är om värme påverkar lagerlägets cylindricitet hos ett lagerhus. Detta avgränsas senare till att gälla enbart värmepåverkan under produktion för en typ av lagerhus i en storlek men tre olika materialval. Därmed koncentreras arbetet på gjuterilinan för de mindre lagerhusen samt den bearbetningslina som kallas ”Robot line”. Inledningsvis ges en presentation vad lager och lagerhus är samt vilken funktion de fyller. Därefter ges en överblick av gjuteriet samt bearbetningen. Berörda linor betraktas mer ingående men även övriga linor ges en övergripande bild av. Övriga resurser såsom mätrum samt testlabb presenteras också. De tre olika materialen granskas för att se vilka avgörande skillnader som finns dem emellan. Detta med hjälp av litteratur samt intervjuer med medarbetare hos SKF Mekan, personal vid Linköpings universitet samt SWEREA. Två test som genomförts under arbetets gång beskrivs, varav det ena lyckat men det andra misslyckat. Dock fick det andra testet ett överraskande resultat. Befintliga kontroller längs med produktionskedjan omtalas. Slutligen sammanfattas vilka moment inom gjuteri- samt bearbetningsprocessen där toleransen för cylindriciteten hos lagerläget riskerar att under-/överskridas samt vad som då är orsaken.
8

CFD Measurements of the Cooling Air in a DC-Motor

Amanatidou, Rebeka January 2008 (has links)
<p> </p><p>The cooling system of a DC-motor is examined in this thesis. A change of direction of the cooling air is desired to prevent the generated coal dust from entering into the windings of the machine. Ultimately this will have a negative effect on the cooling in the machine and the loss of cooling needs to be compensated through other ways. The purpose of this thesis is to work for an improved operational safety and performance of the DC-motor and to make it more competitive in the market. By modelling the interior geometry of the machine and defining the boundaries in the software programs Gambit and FLUENT respectively, the motion and the heat transfer of the airflow could be simulated. The simulation results would give us an understanding of the flow pattern which later could be used to develop design modifications on the cooling system of a DC-motor. In this thesis the main focus lies on creating a simulation model with a sufficiently fine mesh size.</p>
9

Metod för analys av elförbrukning i hushåll

Walde, Fredrik January 2009 (has links)
No description available.
10

Simulation and Evaluation of Two Different Skin Thermocouples : A Comparison made with Respect to Measured Temperature

Lundh, Joel January 2007 (has links)
<p>The demand for more accurate measurements is increasing in today’s industry. One reason for this is to optimize production and thus maximize profits. Another reason is that in some cases government regulations dictate that supervision of certain parameters must be followed. At Preemraff Lysekil there are basically four reasons for measuring skin temperatures inside fired process heaters, namely; because of government regulations, in order to estimate the load of the fired process heater, to estimate the lifetime of the tubes inside the fired process heater and finally, to determine the need of decoking. However, only the first three of these reasons are applied to H2301/2/3. The current skin thermocouple design has been in use for many years and now the question of how well it measures surface temperature has risen. Furthermore a new weld-free design is under consideration to replace the old skin thermocouple design. Another question is therefore how well the new design can measure the surface temperature under the same operating conditions as the old one. In order to evaluate this, three–dimensional computer simulations were made of the different designs. As this thesis will show, the differences in calculated skin thermocouple temperature and calculated surface temperature is about the same for the two designs. However, the current design will show a lower temperature than the surface temperature, while the new design will show a higher temperature. Regarding the core of the skin thermocouple designs, namely the thermocouple, no hard conclusions can be drawn, although the industry appears to favor type ’N’ over type ’K’.</p>