• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 106
  • 57
  • Tagged with
  • 163
  • 163
  • 143
  • 97
  • 57
  • 18
  • 14
  • 11
  • 11
  • 11
  • 10
  • 10
  • 10
  • 10
  • 9
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

A Radial-Ulnar Deviation and Wrist-Finger Flexion Analysis Based on Electromyography

Kawnine, Tanzim January 2008 (has links)
<p>This study is aimed to determine the electromyographic signals of the forearm, using Ag/AgCl electrodes. The four major muscles of forearm, which are providing the bioelectrical currents, have been displayed and analysed to determine the different activities. In order to record the signals, an EMG device has been developed and installed and a schematic has also been presented in this paper.</p>
22

A Radial-Ulnar Deviation and Wrist-Finger Flexion Analysis Based on Electromyography

Kawnine, Tanzim January 2008 (has links)
This study is aimed to determine the electromyographic signals of the forearm, using Ag/AgCl electrodes. The four major muscles of forearm, which are providing the bioelectrical currents, have been displayed and analysed to determine the different activities. In order to record the signals, an EMG device has been developed and installed and a schematic has also been presented in this paper.
23

Assessment of cerebrospinal fluid system dynamics : novel infusion protocol, mathematical modelling and parameter estimation for hydrocephalus investigations

Andersson, Kennet January 2011 (has links)
Patients with idiopathic normal pressure hydrocephalus (INPH) have a disturbance in the cerebrospinal fluid (CSF) system. The treatment is neurosurgical – a shunt is placed in the CSF system. The infusion test is used to assess CSF system dynamics and to aid in the selection of patients that will benefit from shunt surgery. The infusion test can be divided into three parts: a mathematical model, an infusion protocol and a parameter estimation method. A non-linear differential equation is used to mathematically describe the CSF system, where two important parameters are the outflow conductance (Cout) and the Pressure Volume Index (PVI). These are used both for clinical and research purposes. The analysis methods for the non-linear CSF system have limited the infusion protocols of presently used infusion investigations. They come with disadvantages such as long investigation time, no estimation of PVI and no measure of the reliability of the estimates. The aim of this dissertation was to develop and evaluate novel methods for infusion protocols, mathematical modelling and parameter estimation methods for assessment of CSF system dynamics. The infusion protocols and parameter estimation methods in current use, constant pressure infusion (CPI), constant infusion and bolus infusion, were investigated. The estimates of Cout were compared, both on an experimental set-up and on 20 INPH patients. The results showed that the bolus method produced a significantly higher Cout than the other methods. The study suggested a method with continuous infusion for estimating Cout and emphasized that standardization of Cout measurement is necessary. The non-linear model of the CSF system was further developed. The ability to model physiological variations that affect the CSF system was incorporated into the model and it was transformed into a linear time-invariant system. This enabled the use of methods developed for identification of such systems. The underlying model for CSF absorption was discussed and the effect of baseline resting pressure (Pr) in the analysis on the estimation of Cout was explored using two different analyses, with and without Pr. A novel infusion protocol with an oscillating pressure pattern was introduced. This protocol was theoretically better suited for the CSF system characteristics. Three new parameter estimation methods were developed. The adaptive observer was developed from the original non-linear model of the CSF system and estimated Cout in real time. The prediction error method (PEM) and the robust simulation error (RSE) method were based on the transformed linear system, and they estimated both Cout and PVI with confidence intervals in real time. Both the oscillating pressure pattern and the reference CPI protocol were performed on an experimental set-up of the CSF system and on 47 hydrocephalus patients. The parameter estimation methods were applied to the data, and the RSE method produced estimates of Cout that were in good agreement with the reference method and allowed for an individualized and considerably reduced investigation time. In summary, current methods have been investigated and a novel approach for assessment of CSF system dynamics has been presented. The Oscillating Pressure Infusion method, which includes a new infusion protocol, a further developed mathematical model and new parameter estimation methods has resulted in an improved way to perform infusion investigations and should be used when assessing CSF system dynamics. The advantages of the new approach are the pressure-regulated infusion protocol, simultaneous estimation of Cout and PVI and estimates of reliability that allow for an individualized investigation time.
24

Patientövervakning

Hamza, Jasmir, Kocer, Fahti January 2002 (has links)
No description available.
25

Patientövervakning

Hamza, Jasmir, Kocer, Fahti January 2002 (has links)
No description available.
26

Skydd till trevägskran för medicinskt bruk : Stopcock protection

Hermansson, Johan, Ståhl, Anton January 2008 (has links)
<p>Detta examensarbete har genomförts i samarbete med ALMI Företagspartner AB</p><p>som arbetar med att främja utveckling av företag och nyföretagande. Tillsammans med Landstinget i Jönköpings län driver de projektet P.U.M.A, Produktutveckling med Medicinsk Anknytning</p><p>Examensarbetet omfattar utveckling av ett skydd till en trevägskran.</p><p>Skyddets syfte är att förhindra ofrivillig justering av de kranar som används vid intravenös infusion av cytostatika, då patienten behandlas i hemmet.</p><p>Vid behandling flödar cytostatikan genom en trevägskran. Kranen monteras på patienten, som har hudkontakt med denna under hela behandlingen.</p><p>I den teoretiska bakgrunden beskrivs metoder för produktutveckling och en rad återkommande begrepp i rapporten.</p><p>Vid genomförandet gjordes inledningsvis en marknadsundersökning, vilken utgjorde underlag för produktkraven.</p><p>Efter idégenerering genomfördes sållning i två faser för att sortera bort koncept som ej uppfyllde ställda krav.</p><p>Sållningen följdes upp med tillverkning av enkla prototyper, vilka utvärderades och låg till grund för val av slutgiltigt koncept.</p><p>Examensarbetet resulterade i ett färdigt koncept som uppfyller de krav som ställdes med avseende på funktion, säkerhet, pris och miljö. Vid eventuell massproduktion av produkten kommer ytterligare tester och finjustering av konstruktionen krävas.</p>
27

Skydd till trevägskran för medicinskt bruk : Stopcock protection

Hermansson, Johan, Ståhl, Anton January 2008 (has links)
Detta examensarbete har genomförts i samarbete med ALMI Företagspartner AB som arbetar med att främja utveckling av företag och nyföretagande. Tillsammans med Landstinget i Jönköpings län driver de projektet P.U.M.A, Produktutveckling med Medicinsk Anknytning Examensarbetet omfattar utveckling av ett skydd till en trevägskran. Skyddets syfte är att förhindra ofrivillig justering av de kranar som används vid intravenös infusion av cytostatika, då patienten behandlas i hemmet. Vid behandling flödar cytostatikan genom en trevägskran. Kranen monteras på patienten, som har hudkontakt med denna under hela behandlingen. I den teoretiska bakgrunden beskrivs metoder för produktutveckling och en rad återkommande begrepp i rapporten. Vid genomförandet gjordes inledningsvis en marknadsundersökning, vilken utgjorde underlag för produktkraven. Efter idégenerering genomfördes sållning i två faser för att sortera bort koncept som ej uppfyllde ställda krav. Sållningen följdes upp med tillverkning av enkla prototyper, vilka utvärderades och låg till grund för val av slutgiltigt koncept. Examensarbetet resulterade i ett färdigt koncept som uppfyller de krav som ställdes med avseende på funktion, säkerhet, pris och miljö. Vid eventuell massproduktion av produkten kommer ytterligare tester och finjustering av konstruktionen krävas.
28

Movement artifact reduction in laser Doppler blood flowmetry : myocardial perfusion applications /

Karlsson, M. G. Daniel, January 2005 (has links) (PDF)
Diss. (sammanfattning) Linköping : Linköpings universitet, 2005. / Härtill 5 uppsatser.
29

Utvärdering av tandkräm för minskad tandkänslighet : En marknadsundersökning av CAPOSAL® Tandkräm / Evaluation of toothpaste for dentin hypersensitivity : A market survey of CAPOSAL® Toothpaste

Razwana, Raisa, Ezeilo, Blessing January 2023 (has links)
Hypersensitive teeth are a regular issue for many people. The ingredients in CAPOSAL® Toothpaste aim to strengthen tooth enamel and relieve sensitivity by mineralization. The effectiveness and functionality of CAPOSAL® Toothpaste have only been studied in controlled lab settings. This thesis is a practical investigation of the desensitizing effectiveness of CAPOSAL® Toothpaste. The degree project's literature review discusses the causes of dentin hypersensitivity, its symptoms, available treatments for it, and the science underlying CAPOSAL®. During the degree project's empirical investigation, a market-based review was conducted where 22 selected candidates got to product test CAPOSAL® Toothpaste and document and evaluate the product. In the pre-investigation stage, suitable candidates were recruited, these must answer a questionnaire before the treatment. Candidates received a kit in the mail containing toothpaste, a toothbrush, and an information sheet. A logbook was used to record usage during the one to two weeks of product testing, and then an evaluation questionnaire was completed.  The market-based empirical study's results indicate that tooth sensitivity was generally decreased. Where the majority of participants reported feeling less discomfort after finishing their CAPOSAL® Toothpaste treatment. However, 2 weeks was not enough to determine the full potential of CAPOSAL® Toothpaste. The results also indicate that women to a slightly higher degree thought that CAPOSAL® Toothpaste worked better in treatment of teeth sensitivity compared to men. Because not all ages were fairly represented in the survey, no generalizations about which age groups CAPOSAL® Toothpaste is more effective on could be made. / Ilningar i tänder är ett vanligt förekommande problem hos många. Partiklarna i CAPOSAL® Tandkräm syftar till att stärka emalj och lindra ilningar i tänderna. Funktionen samt effekten av CAPOSAL® Tandkräm har endast prövats i laboratorium och i kontrollerade miljöer. För att undersöka CAPOSAL® Tandkräms förmåga att lindra ilningar i praktiken utförs detta examensarbete. Examensarbetet genomförs via företaget Psilox AB. Frågeställningarna som examensarbetet besvarar lyder:  Kommer resultaten från marknadsundersökningen tyda på att kandidaternas upplevda ilningar har lindrats av CAPOSAL® Tandkräm?  Kommer en till två veckor vara tillräckligt med tid för att se tydliga resultat med avseende på ilningar i tänderna?  Verkar CAPOSAL® Tandkräm bättre på någon specifik målgrupp med avseende på ålder och kön?  Examensarbetet redogör i sin litteraturforskning hur dentin överkänslighet uppkommer, vilka symptom det har och behandlingsalternativ mot överkänslighet samt forskningen bakom CAPOSAL®. Under examensarbetets empiriska undersökning gjordes en marknadsbaserad granskning där 22 utvalda kandidater fick produkttesta CAPOSAL® Tandkräm och dokumentera samt utvärdera produkten. I förundersökningsstadiet rekryterades lämpliga kandidater med hjälp av inlägg på sociala medier och broschyrer placerade på olika campus på Uppsala universitet. Utvalda kandidater fick besvara ett frågeformulär innan behandlingen, erhållet svar var essentiellt för att kunna jämföra resultatet efter behandlingen. Kandidaterna fick hemskickat ett kitt bestående av tandkräm, tandborste samt ett informationsblad. Informationsbladet innehöll instruktioner för korrekt tandborstning för att säkerställa att alla kandidater fick samma förutsättningar i undersökningen. Inkluderad i informationsblad var även en kort översikt om examensarbetet och den rollen som kandidaterna har i undersökningen. Produktprövningen pågick under en till två veckor där användningen dokumenterades i en loggbok, därefter fylldes slutligen ett utvärderingsformulär in. Utifrån förundersökningsstadiet, loggboken och utvärderingsformulären sammanställdes resultaten som besvarade på examenarbetets frågeställningar.  Resultat som erhölls från den marknadsbaserade empiriska undersökningen påvisar en förbättring överlag med avseende på ilningar i tänderna. Där majoriteten av medverkande påstod att smärtan har reducerats efter avslutad behandling med av CAPOSAL® Tandkräm har endast prövats i laboratorium och i kontrollerade miljöer. För CAPOSAL® Tandkräm syftar till att stärka emalj och lindra ilningar i tänderna. Funktionen samt effekten att undersöka CAPOSAL® Tandkräms förmåga att lindra ilningar i praktiken utförs detta examensarbete. Examensarbetet genomförs via företaget Psilox AB. konstateras att två veckor inte är tillräckligt för att avgöra fullständiga potentialen hos CAPOSAL® Tandkräm. Efter noggrann analys av erhållet resultat samt jämförelse av tidigare forskning kan det CAPOSAL® Tandkräm. Ytterligare forskning och undersökningar krävs för att konstatera CAPOSAL® Tandkräms verkningsgrad. Resultaten indikerar även att kvinnor i lite högre grad tyckte att CAPOSAL® Tandkräm verkade bättre på ilningar i tänderna jämfört med män. Dock är det svårt att dra någon slutsats om vilket kön som har upplevt mest positivt resultat från CAPOSAL® Tandkräm på grund av begränsade insamlade data. I undersökningen representerades inte alla åldrar jämnt vilket resulterade i att ingen slutsats kunde dras om CAPOSAL® Tandkräm verkar bättre på någon specifik åldersgrupp.
30

Methods for improving quality and efficiency in quantitative echocardiography : Aspects of using high frame rate

Aase, Svein January 2008 (has links)
<p>Ultralyd er i dag et standardverktøy innen hjertediagnostikk. Analyse av ventrikkelfunksjon gjøres subjektivt ved å se på gråskala ultralydopptak av hjertet. Dette gjør dokumentasjon og opplæring vanskelig. Det er derfor ønskelig med kvantitative mål på ventrikkelfunksjon. Kvantitative metoder kan benytte høy tidsoppløsning og dermed også registrere flere detaljer.</p><p>To teknikker for kvantitativ ventrikkelanalyse er vevs-Doppler og speckle tracking (mønsterfølging). Ved bruk av disse teknikkene er det viktig å sikre kvaliteten av resultatene samtidig som analyseprosessen kan gjennomføres så effektivt som mulig. I denne avhandlingen presenteres flere metoder for å sikre kvalitet og øke effektivitet ved kvantitativ ventrikkelanalyse som alle er relatert til bruk av høy tidsoppløsning.</p><p>For å kunne gjøre effektiv ventrikkelanalyse behøves analyseverktøy. Et slikt verktøy som fungerer med både vevs-Doppler og speckle tracking presenteres i denne avhandlingen. Dette verktøyet har gjort flere store kliniske studier mulig. Ved analyse av hendelsene som skjer innen en hjertesykel er det viktig å dele opp hjertesykelen i ulike faser. Venstre ventrikkels tømmingsfase avsluttes ved at aortaklaffen lukkes, og denne hendelsen må derfor bestemmes før kvantitative parametre i slutten av tømmingsfasen og i overgangen til fyllingsfasen kan bestemmes. I denne avhandlingen vurderes og testes ulike kandidater for bestemmelse av lukkingen. To gunstige kandidater i hastighetskurver fra basale deler av ventrikkelen ble funnet: andre nullkryssing etter tømming og høyeste positive akselerasjon etter tømming før fylling. Et eget bidrag viser at den siste av disse kan bestemmes automatisk. For å oppnå høy tidsoppløsning kreves høy datarate. En populær metode for å øke datarate er flere parallelle mottaksstråler for hver sendestråle. I vanlig gråtoneavbilding av hjertet er det imidlertid observert at dette medfører uønskede linjelignende strukturer i bildet. I denne avhandlingen vises det at årsaken til dette er at de parallelle strålene deformeres når de passerer strukturene mellom hjertet og proben. Avhandlingen inneholder også et bidrag som viser hvordan bruk av parallelle mottakstråler kan medføre at vevs-Doppler kurver blir hentet fra et annet sted i hjertet enn det intensjonen var. Samlet er avhandlingen et bidrag til fortsatt utvikling og forbedring av kvantitative ultralydmetoder innen hjertediagnostikk.</p>

Page generated in 0.0453 seconds