• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 5
  • 5
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de parâmetros ergonômicos : vibração e ruído em roçadoras laterais /

Schutzer, Victor Manieri. January 2018 (has links)
Orientador: João Eduardo Guarnetti dos Santos / Banca: Bento Rodrigues de Pontes Junior / Banca: Ricardo Carvalho Tosin / Resumo: A crescente mecanização na agricultura mundial foi acompanhada do aumento do número de acidentes e fez com que elevasse a preocupação com a saúde de seus operadores, já que tais trabalhadores estão expostos aos riscos que esse tipo de atividade proporciona. Alguns dos graves problemas que são gerados pelos equipamentos agrícolas é a alta vibração e ruído a que os operadores ficam expostos na sua jornada de trabalho. A vibração que atinge os trabalhadores pode ser considerada como um distúrbio, já que é responsável por grandes prejuízos à saúde do ser humano, estando diretamente relacionada com a fadiga do trabalhador. O ruído, considerado como um som indesejável, é outro problema gerado por máquinas motoras e responsável por lesão no aparelho auditivo e, até mesmo, por estresse psicofisiológico. Para o presente trabalho, analisou-se os riscos físicos que a vibração e o ruído causam em operadores de roçadoras motorizadas. Foram feitas análises de situações reais que os usuários deste tipo de máquina enfrentam no seu dia a dia de trabalho, para que se possa tirar conclusões da possibilidade de efeitos danosos. Para a pesquisa utilizou-se um acelerômetro de três eixos - HVM 100, marca Larson Davis, para mensurar a vibração captada pela mão do operador e um medidor de pressão sonora, marca Instrutherm, modelo DEC-460 para mensurar o ruído causado pela roçadora. Para a análise da vibração captada pela mão dos operadores foi utilizada a norma internacional ISO 5349 (2001) - Vibraçã... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The increasing mechanization in world agriculture was accompanied by an increase in the number of accidents has caused concern about the health of its operators, as these workers are exposed to risks that this type of activity provides. Some of the serious problems that are generated by agricultural equipment are the high vibration and noise to which operators are exposed in their work. The vibration that affects the workers can be considered as a disorder, since it is responsible for major damages to the health of human beings, being directly related to worker fatigue. Noise, regarded as an unwanted sound, is another problem caused by motorized machines and responsible to hearing damage and even to psychophysiological stress. For this study, a physical risks analysis was made. So it is possible to determine the damage that vibration and noise can cause in motorized brushcutter's operators. Real situations of the daily work that these users go through were analyzed, so that conclusions can be made of the possibility of harmful effects. For the research, an accelerometer of three axes - HVM 100, Larson Davis brand, was used to measure the vibration captured by the hand of the operator and a sound pressure meter, Instrutherm brand model DEC-460, was used to measure the noise caused by brushcutters. For the vibration analysis captured by the hand of the operators, the international standard ISO 5349 (2001) - Mechanical Vibration - Measurement and Evaluation of Human Exposure to ... (Complete abstract click electronic access below) / Mestre
2

Estudo do reflexo inibitorio retoanal em multiparas, na zona de alta pressão com cateter radial

Leal, Vilmar Moura 29 January 2003 (has links)
Orientador: Claudio Saddy Rodrigues Coy / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-03T16:26:48Z (GMT). No. of bitstreams: 1 Leal_VilmarMoura_M.pdf: 1606636 bytes, checksum: 7b12d0641f97608e38b55b8cc93da306 (MD5) Previous issue date: 2003 / Resumo: A fisiologia da evacuação e a fisiopatologia dos distúrbios evacuatórios ainda hoje não são bem compreendidas. A ocorrência destes distúrbios vem aumentando progressivamente, implica em limitações, compromete a qualidade de vida e tem custos significativos. A incontinência fecal acomete cerca de 2% da população, com predomínio em mulheres e que tenham tido partos normais. Com relação à constipação, em 30 a 50% dos casos, a causa é funcional. Os testes para o estudo da fisiologia anorretal têm sido bastante utilizados, especialmente a manometria. No entanto, algumas variáveis deste exame ainda apresentam dúvidas quanto sua interpretação. Dentre estas, destaca-se o Reflexo Inibitório Retoanal (RIRA), freqüentemente descrito como presente, ausente ou inconclusivo. Apenas recentemente vem sendo realizada uma abordagem mais pormenorizada deste. Sendo a pesquisa deste reflexo comumente realizada com cateter axial e considerando a assimetria anatômica do canal anal, seu estudo na zona de mais alta pressão (ZAP) com cateter radial poderia adicionar informações não disponíveis. Objetivo: estudar os parâmetros do reflexo inibitório retoanal em multíparas, com cateter radial. No período entre 2001 e 2002, foram estudadas 36 pacientes, com quatro a seis partos vaginais, com média de idade de 40,7 (30 a 50) anos, Grupo 1 e 10 pacientes, com um a três partos vaginais, com média de idade de 38,5 (31 a 50) anos, Grupo 2. Com relação à função evacuatória do Grupo 1, 63,9% das pacientes encontravam-se assintomáticas, 33,3% apresentavam como queixa constipação e 2,8% incontinência fecal. Dentre as pacientes do Grupo 2, 50% eram assintomáticas e as demais referiam constipação. Todas as pacientes são oriundas do Hospital Getúlio Vargas ¿ Teresina - PI - Universidade Federal do Piauí (UFPI). Foram analisados na ZAP a pressão anal média de repouso (PAM) e os seguintes valores por quadrante: pressão média de repouso pré-relaxamento (PREP), porcentagem de relaxamento (%RELAX), pressão no ponto de máximo relaxamento (PRELAX), tempo de relaxamento (TRELAX) e o tempo de recuperação (TREC). Não houve diferença significante entre as médias de idades dos pacientes dos Grupos 1 e 2 (p = 0,43), assim como entre as médias da pressão anal média de repouso (p = 0,053). Os valores das médias da PREP nos quadrantes apresentaram diferença com significância estatística, no Grupo 2. A comparação dos valores desta variável entre os Grupos 1 e 2 foi estatisticamente diferente nos quadrantes com exceção do anterior. Os valores das médias de PRELAX foram mais baixos e com significância estatística no Grupo 1, a comparação entre os grupos evidenciou diferença estatisticamente significante nos quadrantes 1 e 4. Não foram evidenciadas diferenças significativas entre os valores das médias de %RELAX no Grupo 1 ou Grupo 2, assim como entre os grupos. Também não ocorreu diferença significativa com relação aos valores dos tempos de relaxamento e de recuperação nos dois grupos, assim como a comparação destas variáveis entre os grupos nos diferentes quadrantes. Os dados obtidos nesta casuística permitem concluir que: 1- a PREP nos quadrantes, tende a uma simetria nas pacientes multíparas, provavelmente decorrente de comprometimento global da função esfincteriana; 2- o Reflexo Inibitório Retoanal(RIRA), contrariamente a PREP, pode ter os parâmetros que o compõe manifestados de maneira irregular nos diferentes quadrantes na ZAP, da mesma forma, em decorrência das alterações estruturais mais prováveis nas pacientes do Grupo 1; 3- a utilização do cateter radial no estudo do Reflexo Inibitório Retoanal (RIRA) pode fornecer dados não obtidos com o cateter axial / Abstract: Physiology of evacuation and physiopathology of evacuatories disturbs still today aren¿t well understood. The occurrence of this disturbs has been rising progressively, it implies in limitation, affects the quality of life and has significant costs. Fecal incontinence occurs at about 2% of population, more in women, especially in those who had vaginal delivery history. In relation to constipation, 30 ¿ 50% of the cases, the cause is functional. Physiologies tests have been used more and more frequently, among these tests the pioneer manometry has gain more attention. Therefore same variables of this test have still doubt about its interpretation. Among this doubts there is the inhibitory recto anal reflex (RIRA), frequently described as present, absent or inconclusive. Only recently a more detailed approach of this complex phenomena has been realized. Once the research of this reflex is commonly made with axial catheter, and considering that anatomy of the anal canal is not symmetric, the study of the RIRA in the high pressure zone (HPZ), with radial catheter could add more information that were not available. Aim: to study parameters of inhibitory recto anal reflex in multiparous, with radial catheter. In the period of 2001 to 2002, 36 patients with 4 to 6 vaginal delivery were studied, with average age 40,7 (30 ¿ 50) years old, belong to Group 1 and 10 patients with 0 to 3 vaginal delivery, with average age 38,5 (31 ¿ 50) years old, belong to Group 2. In relation to evacuation function in Group 1, 63,9% of the patients were asymptomatic, 33,3% had constipation and 2,8% had fecal incontinence. Among the patients of Group 2, 50% were asymptomatic and 50% were constipated. All patients were from Hospital Getúlio Vargas ¿ Teresina ¿ PI ¿ Federal University of Piauí ¿ UFPI. This study was approved by Ethical Committee of this university. In HPZ, anal resting pressure (ARP) and the follow values for quadrant: average of resting anal pressure before relaxation (PREP), percentage of relaxation (%RELAX), pressure at the point of maximum relaxation (PRELAX), relaxation time (TRELAX) and recovery time (TREC) were analyzed. There weren't significant difference between average age of the patients in the two groups (p = 0,43) as far as average of resting anal pressure (p = 0,053). The average values of PREP among quadrants had statistics significant differences in Group 2. The comparison of the values of this variable in two groups was statistically different in the quadrants except in the anterior. The values of PRELAX average were smaller and with statistics difference in Group 1, the comparison between groups shows statistics significant differences in quadrants 1 and 4. No significant differences were observed in the values of %RELAX in Group 1 or Group 2, as far as between the groups there were. Also no differences with relaxation and recovery time among quadrants in the groups as far as between groups. The data obtained in this study permit the following conclusion: 1- PREP among quadrants tend to a lack of symmetry in multiparous patient, probably because of global involvement of sphincter function; 2- RIRA in opposition of PREP, can have its parameters manifested of irregular way among quadrants of HPZ, the same way because of structural alterations more probably in patients of Group 1; 3- Use of radial catheter in study of RIRA can produce data that can not be obtained with axial catheter / Mestrado / Medicina Interna / Mestre em Ciências Médicas
3

Desenvolvimento de um sistema de verificação da pressão arterial através do método oscilométrico

Pereira, Léo Fabrício January 2006 (has links)
Made available in DSpace on 2013-08-07T18:53:44Z (GMT). No. of bitstreams: 1 000346861-Texto+Parcial-0.pdf: 1247028 bytes, checksum: 6cdf9feef272bc4395446fc3f7de312a (MD5) Previous issue date: 2006 / The verification of the blood pressure measure is of great importance for the cardiovascular diagnosis and mainly for the attendance of therapeutic interventions however the invasive methods today used are expensive and mainly aggressive to the patient, reducing for his/her reasons application. This study intends to obtain, for non-invasive methods, the measure of the human patient's blood pressure. This consists of the acquisition of the systolic, diastolic and mean arterial blood pressures simultaneously as well as the presentation of these in a viewfinder. The acquired values using the non-invasive method will be compared to resulting data of the acquisition invasive of the blood pressure by catheter intra-aortic that pattern-gold is considered. The obtained signs by the non-invasive they will be conditioned directly in the computer after they be captured by an acquisition plate dose to the sensor that it is located in the cuff of the apparel. Already the obtained data in a conventional way will be located in a monitor which will also be transferred to the computer. / A verificação da medida de pressão arterial é de grande importância para o diagnóstico de doenças cardiovasculares e principalmente para o acompanhamento de intervenções terapêuticas, porém os métodos invasivos hoje utilizados são caros e principalmente agressivos ao paciente, reduzindo por estes motivos sua aplicação. Este estudo pretende obter, por métodos não-invasivos, a medida da pressão arterial de pacientes humanos. Isto consiste na aquisição das pressões sistólicas, diastólicas e médias de forma "simultaneamente" bem como a apresentação destas num visor. Os valores adquiridos pelo método não-invasivo serão comparados a dados resultantes da aquisição invasiva da pressão arterial por carater intra-aórtico que é considerado padrão-ouro. Os sinais obtidos de maneira não-invasiva serão acondicionados diretamente no computador após serem captados por uma placa de aquisição junto ao sensor que está localizado no manguito do aparelho. Já os dados obtidos de maneira convencional estão localizados em um monitor os quais também serão transferidos para o computador. Este trabalho não tem como objetivo realizar testes em seres humanos. Assim, para validar o sistema proposto, serão realizados testes em pacientes virtuais com uma amostragem de dez medidas para diferentes níveis de pressão, tanto para o caso de “pacientes” adultos quanto para neonatais.
4

Analise dos efeitos da temperatura e do tempo de utilização em elementos sensores tipo tubo de Bourdon / Analyze the effect of the temperature and the time of use in sensing elements type Bourdon tube

Iano, Marcos Chogi 14 August 2018 (has links)
Orientador: Kamal Abdel Radi Ismail / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-14T07:39:10Z (GMT). No. of bitstreams: 1 Iano_MarcosChogi_D.pdf: 40621209 bytes, checksum: d971e987a0e70601a78ccb0bd1587e8e (MD5) Previous issue date: 2009 / Resumo: Instrumentos de monitoramento como termômetros, multímetros, voltímetros, manômetros, etc, são imprescindíveis para o controle e confiabilidade de um processo. No entanto, não muito raramente, os cuidados para o perfeito funcionamento destes instrumentos são colocados em segundo plano ou negligenciados. Os resultados destes descuidos, em um primeiro momento, são variações no processo e em um cenário mais negativo, interrupção e possíveis acidentes. Neste estudo, procurou-se analisar os efeitos da temperatura e do tempo de utilização nos elementos sensores de manômetros que utilizam tubo de Bourdon. Para induzir e acelerar estes efeitos montou-se uma bancada de testes composta de um reservatório onde os manômetros foram submergidos e submetidos a variações de temperatura por tempos determinados e um sistema de controle da pressão exercida sobre os manômetros. Tanto no inicio, quanto ao final de cada bateria de solicitação, os manômetros foram re-calibrados. Deste modo, geraram-se parâmetros para comparações e subsídios para se determinar os erros relativos dos instrumentos, oriundos da deterioração dos elementos sensores. Com base nos resultados alcançados puderam-se determinar, de forma a orientar os usuários de instrumentos/sistemas similares, os erros relativos esperados em cada faixa de temperatura, pressão e tempo de utilização destes instrumentos, além de auxiliá-lo na determinação do período ideal para calibrações e conhecimento de sua vida útil. / Abstract: Systems monitoring instruments like thermometers, multimeters, voltmeters, manometers, etc, are of such importance to monitor and processes reliability controlling. However, it's uncommon to have the due cares for their perfect operation being in certain moments put in second place or neglected. The results of those improper cares are the process variation and afterwards a more negative/imprecise scenario, unexpected interruption and worse possible accidents. In this study, it was analyzed the effect of temperature and time when using sensing elements like manometers which use Bourdon tube. To induce and accelerate these effects one work-bench tests was built consisting of a reservoir where the manometers were submerged and submitted under temperature variation to certain pre-determined times and a pressure controlling system on the manometers inserted. Within each pre-determined test sequence as the manometers were re-calibrated. Based on the obtained results this work gives subsidies to determine the deriving relative errors due to the sensing elements deterioration., moreover assist the user on the expected relative errors in each band of temperature, pressure and time, beyond of that determinate the ideal calibration period to obtain a known useful instrument lifetime. / Doutorado / Termica e Fluidos / Doutor em Engenharia Mecânica
5

Tonometro eletronico para a medida da pressão intraocular

Fossey, Marcelo Andre 09 January 1985 (has links)
Orientador: Wang Binseng / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-15T11:51:29Z (GMT). No. of bitstreams: 1 Fossey_MarceloAndre_M.pdf: 1942478 bytes, checksum: be673589961b28b0f1ac699750d312aa (MD5) Previous issue date: 1985 / Resumo: Devido às graves implicações sociais do glaucoma, e ao fato dele ser relativamente imperceptível no início, é necessário a avaliação da pressão intra-ocular (PIO) toda vez que se efetua o "check-up"., pois pressões prolongadas acima de 21 mmHg podem causar alteração do campo visual e, se não tratado em tempo, cegueira ao paciente. Atualmente os tonômetros utilizados no Pais são importados, apresentando alto custo, baixa precisao (tonômetro de Goldmann) e pouca confiabilidade (tonômetros eletrônicos). Foi projetado e construido um tonômetro eletrônico, com materiais e componentes facilmente encontráveis no mercado nacional. A PIO é medida por uma ponta de prova, no centro da qual existe um pino rigidamente acoplado a uma cerâmica piezoelétrica, que ao ser deformada pela PIO produz uma tensão elétrica e, ao se detetar eletronicamente a condição de aplanação, é registrado o valor da PIO num display digital. Para aumentar a confiabilidade, o tonômetro foi montado num suporte com o formato de revólver, com dois suportes laterais. Este tonômetro pode ser utilizado com.o paciente na posição vertical ou reclinado, sem o auxílio da lâmpada de fenda. / Abstract: The grave social consequences of glaucoma and the fact its onset is relatively imperceptivable make evaluation of the intraocular pressure (IOP) essential at each Iredical examination. Prolonged IOPs above 21 nmHg may cause alterations in the visual field and, if not treated, blindness in the patient. At the present time, alI tonometers used in Brazil are irnported. 1n general, they present either high cost and low precision (Goldman tonometers) or little reliability (electronic tonometers). An electronic tonometers was designed and built using materiaIs and corrponents available in Brazil. The IOP is measured with a probe at the center of which exists a pin fixed rigidly onto a piezoelectric transducer, whose deforrnation by tpe IOP produces an electric signal. As the cornea is depressed by the probe, the applanation, condition is detected electronically and the value of IOP thus detected is displayed digitally. To provide reliable measurerrents, the tonometer was mounted in front of a pistol-like holder with two supports to be positioned on, the facial banes. The instrument may be used with the patient in any position without the need af a slit lamp. / Mestrado / Mestre em Engenharia Elétrica

Page generated in 0.0971 seconds