• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Acquisition multiparamétrique de signaux de décroissance radioactive pour la correction des défauts instrumentaux : application à la mesure de la durée de vie du 19Ne / Multiparametric acquisition of radioactive decay signals for instrumental defects correction. : application to the 19Ne lifetime measurement

Fontbonne, Cathy 01 February 2017 (has links)
L’objectif de cette thèse est de proposer une méthode de mesure précise d’une période radioactive de l’ordre de quelques secondes. L’acquisition numérique temps réel FASTER permet d’accéder aux caractéristiques physiques du signal induit par la détection de chaque désintégration lors de la décroissance radioactive. La sélection des données de comptage peut se faire par une analyse optimisée post-expérience. Ainsi, après avoir établi les facteurs d’influence de la mesure (variation d’empilements, de gain des tubes photomultiplicateurs, de la ligne de base électronique), il est possible, a posteriori, de calculer leur impact sur l’estimation de la période radioactive, et de choisir un seuil en énergie déposée, ainsi qu’un temps mort qui minimisent leurs influences. Cette thèse propose, par ailleurs, une méthode pour mesurer, puis compenser les variations de ses grandeurs. Cette méthode a été appliquée pour l’estimation de la période radioactive du 19Ne avec une incertitude relative de 1,2.10-4 : T1/2=17,2569(21) s. / The aim of this thesis is to propose a method for precise half-life measurements adapted to nuclides with half-lives of a few seconds. The FASTER real-time digital acquisition system gives access to the physical characteristics of the signal induced by the detection of each decay during the counting period following beam implantation. The selection of the counting data can be carried out by an optimized post-experimental offline analysis. Thus, after establishing the influence factors impacting the measurement (pile up, gain and base line fluctuations), we are able to estimate, a posteriori, their impact on the half-life estimation. This way, we can choose the deposited energy threshold and dead time in order to minimize their effect. This thesis also proposes a method for measuring and then compensating for influence factors variations. This method was applied to estimate the 19Ne half-life with a relative uncertainty of 1.2 10-4 leading to T1 / 2 = 17.2569 (21) s. This is the most precise measurement to date for this isotope.
2

Développement et optimisation d'un système de polarisation de neutrons ultra froids dans le cadre d'une nouvelle mesure du moment dipolaire électrique du neutron

Pierre, Edgard 26 March 2012 (has links) (PDF)
Le travail réalisé dans ce mémoire de thèse s'inscrit dans le cadre d'une expérience effectuée à l'institut Paul Scherrer (PSI) et dédiée à la mesure du moment dipolaire électrique du neutron (nEDM). Une sensibilité de 1027 e.cm est attendue à la fin 2013. La mesure est réalisée avec des neutrons ultra-froids (UCN) polarisés. Pour ce faire, de nouveaux systèmes de polarisation, de transport et d'inversion de spin ont été réalisés. Leur étude est présentée dans ce mémoire. Ils sont actuellement utilisés auprès de l'expérience. Grâce à des mesures de champs magnétiques effectuées sur le spectromètre, des simulations de champs réalisées avec les codes Radia et Maentouch, ainsi qu'à des simulations Monte-Carlo effectuées avec le code Geant4, l'efficacité du dispositif de polarisation a été calculée. L'efficacité mesurée en direct est de 88.5 0.3%, soit légèrement moins que la valeur attendue de 95%. Par ailleurs, la prise de données préliminaire effectuée en octobre 2011 a permis de déterminer certains des paramètres fondamentaux de l'expérience, tel les constantes de temps de remplissage, de stockage et de dépolarisation longitudinale du spectromètre. Ces paramètres sont encourageants pour la suite de l'expérience.

Page generated in 0.1048 seconds