• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efeito da temperatura de pré-aquecimento e características do pulso na microestrutura de aço estrutural de alta resistência e baixa liga soldado com arco elétrico e proteção gasosa /

Godoy, Wagner Lopes de. January 2008 (has links)
Orientador: Yukio Kobayashi / Banca: Carlos Alberto Soufen / Banca: Antônio de Padua Lima Filho / Resumo: A identificação e a qualificação dos constituintes microestruturais de uma junta soldada são de grande importância pela relação que existe entre a microestrutura do cordão e as propriedades mecânicas, particularmente a tenacidade. Trabalhando com variações nos parâmetros de pulso, corrente de pico e tempo de pico, e também na temperatura de pré-aquecimento, foram quantificados os constituintes ferrita acicular e microfases presentes no metal de solda; sendo ambos considerados controladores da tenacidade. Os resultados deste trabalho demonstraram que aumentou a quantidade de ferrita acicular para os menores níveis dos parâmetros de pulso e da temperatura de pré-aquecimento. Quanto às microfases, ocorreu uma redução na quantidade à medida que se elevaram os níveis dos parâmetros de pulso e da temperatura de pré-aquecimento. Observou-se, também, qual foi a influência da velocidade de resfriamento na microestrutura final do metal de solda. Foi utilizado o processo de soldagem a arco elétrico com proteção gasosa, no modo pulsado e arame tubular. A soldagem foi realizada em chapa de aço estrutural de alta resistência e baixa liga (COS-AR 50), com chanfro em "X" e ângulo de 30º. Como metal de adição foi utilizado o arame tubular de fluxo metálico E70C-6M, com diâmetro de 1,2 mm. / Abstract: The identification and qualification of the microstructural constituents present in the welded joint are very important for the relationship between the microstructure of the weld beads with the mechanical properties, particularly toughness. Working with variations of pulse parameters, peak current and peak time, and also preheating temperature, had been quantified the constituents acicular ferrite and microphases present in weld metal; being both considered controllers of toughness. The results of this work demostrated that greater amounts of acicular ferrite had been occurred in the lowest levels of pulse parameters and preheating temperature. As for microphases, it has a reduction of the amount with the increase of pulse parameters and preheating temperature. It was observed, also, the influence of the cooling speed in the final microstructure of the weld metal. The samples were welded by the metal gas arc welding, using pulsed arc and tubular wire. As metal base was used HSLA structural steel plate (COS-AR 50), with "X"-groove and bevel angle 30º. The addition metal was the tubular metal-cored wire "E70C-6M" with diameter of 1.2 mm. / Mestre
2

Estudo da soldagem GMAW convencional e pulsada de aço estrutural temperado e revenido utilizando eletrodo de alma metálica /

Sarni, Mírian Isabel Junqueira. January 2011 (has links)
Orientador: Gilberto de Magalhães Bento Golçaves / Banca: Carlos Elias da Silva Junior / Banca: Geraldo Luiz Palma / Resumo: Este trabalho avaliou as ocorrências mecânicas, macro e microestrutural em metal de solda de juntas de aço estrutural temperado e revenido, soldadas pelo processo a arco elétrico com proteção gasosa (GMAW) de 80%Ar-20%CO2, em modo convencional e pulsado, utilizando eletrodo de alma metálica ("metal cored"), designação AWS E70C-6M. As soldas foram realizadas em dois passes, um por lado de juntas preparadas com chanfro duplo "V"60º. Para uma mesma energia teórica de soldagem, comparativamente verificou-se aumentos nas eficiências de deposição e térmica do processo para a soldagem com arco pulsado, além de uma maior influência na diluição do metal de base e nas características geométricas dos cordões. Entretanto, foi constatada maior resistência mecânica para os metais de solda obtidos em modo convencional, atribuído à ocorrência de um refinamento microestrutural mais intenso nesta condição de soldagem. A expectativa desta contribuição é de que disponibilize maiores informações em metalurgia da soldagem para atender principalmente o segmento de fabricação de equipamentos e sistemas mecânicos aplicados a serviços abrasivos / Abstract: This study evaluated the mechanical, macro and microestrurtural events on metal weld joints of quenched and tempered structural steel, welded by eletric arc process with protective gas (GMAW) of 80% Ar-20% CO2 in conventional and pulsed mode using metal cored electrode, designation AWS E70C-6M. The welds were made in two passes, one on each side of joints prepared with 60º double "V" bevel. For a given theoretical energy welding, comaratively there was increases in the efficiencies of deposition and thermal for pulsed arc welding process, and a greater influence on the dilution of the base metal and the geometrical characteristics of the cords. However, was observed a higher mechanical strength for a weld metals obtained in conventional manner, attributed to the occurrence of an intense microstructural refinement in this welding condition. The expectation of this contribution is to make evailable more information on welding metallurgy to meet especially the segment of manufacturing equipment and mechanical systems applied to abrasive services / Mestre

Page generated in 0.0705 seconds