• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • Tagged with
  • 33
  • 33
  • 7
  • 6
  • 6
  • 6
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

The optimization and calibration of spark-optical emission spectroscopy for the analysis of trace impurities in ultra-pure Pt, Pd and Rh

Mogorosi, Moleboge Prudence 05 March 2014 (has links)
Since the industrialization of platinum group metals (PGMs), particularly platinum (Pt), palladium (Pd) and rhodium (Rh), the control of trace impurities in these metals has become vital. Reliable analysis of impurities in these metals is, however a difficult task. Nobel metals are difficult to dissolve quickly and quantitatively. Thus, analytical techniques which determine samples in liquid form have become less favourable. They require time consuming digestions and are prone to contamination both from the chemicals and equipment used for the preparation. Direct-analysis techniques are increasingly being used in the platinum group metal (PGM) industry for the determination of impurities in the final products. Spark-optical emission spectroscopy (Spark-OES) for the analysis of metals offers rapid turnaround times. Since the technique is almost non-destructive, little of the product is lost during analysis. The technique is also well established in the PGM industry. It is routinely used by two of the three largest platinum producing companies for the determination of impurities in their products. It is also used for the determination of PGMs after Fire Assay procedure by Anglo American Platinum. The greatest challenge for this technique remains the availability of certified reference materials (CRM) and calibration standards. This study investigates the use of the Spark-OES for the determination of impurities in PGMs (notably gold (Au), silver (Ag), iron (Fe), nickel (Ni), copper (Cu), lead (Pb), magnesium (Mg), manganese (Mn), silicon (Si), aluminium (Al), antimony (Sb), chromium (Cr), tin (Sn), titanium (Ti), zirconium (Zr), calcium (Ca), zinc (Zn), boron (B), cobalt (Co), vanadium (V), molybdenum (Mo), bismuth (Bi), arsenic (As), selenium (Se), tellurium (Te), cadmium (Cd) in refined platinum, palladium and rhodium metals). It is to be used at Anglo American Platinum’s final metal’s laboratory. A method to be used routinely in the laboratory is also developed. The concentration of the impurities determined is used to quantify the overall purity of the PGMs. PGMs, other than the matrix (the metal whose purity is being quantified), are also determined. The use of Spark-OES was evaluated as an alternative to inductively coupled plasma-optical emission spectroscopy (ICP-OES). Due to the lack of CRMs and calibration standards, the study included the preparation of in-house reference material (IRM) for calibration and quality control purposes. The standards were prepared by spiking pure PGM metal sponges (produced by Anglo Platinum) with the metal oxides of the elements of interest. These were melted together using a vacuum induction furnace to produce metal disks. The disks were ground and analysed after dissolution using ICP-OES. The metal disks, and the shavings, were distributed to three other independent laboratories and analyzed by ICP-OES, inductively coupled plasma-mass spectroscopy (ICP-MS) and Spark-OES. The assigned consensus values were used for the calibration of the Spark-OES. The method was validated for linearity, accuracy, precision, robustness, bias and the measurement uncertainty of the method. The metal disks were first tested for homogeneity. It was found that the bottom surface of the rhodium metal was not homogenous. Rapidly cooled moulds, will facilitate almost instantaneous cooling of the metal. This eliminates the migration of elements during cooling. This could assist with homogenizing the metal. Limits of detections (LODs) achieved for the methods ranged from 0.1 mg.kg-1 to 4 mg.kg-1. The highest LOD was for silicon, which was caused by contamination from the crucibles used. The precision for all impurity elements, except ruthenium (Ru), of the three methods (analysis of platinum, palladium and rhodium) was satisfactory. Ru showed poor precision in all the matrices due to the channel installed in the spectrometer. Due to the lack of CRMs, the traceability of the method could not be validated and the accuracy could only be validated by comparing it to in-house reference material. Although the method met the validation criteria, it cannot be used to certify the purity of the product as the traceability could not be validated. It suggests that the method be used for twin stream analysis in conjunction with a primary method. Because of its rapid turnaround time, and its non-destructive nature, the method can be used for plant control purposes, where the level of accuracy required is not as stringent as required on a certificate of analysis.
2

Lead, zinc, and copper (II) complexes of 4-(2-pyridylazo)-resorcinol in aqueous solution : their identification, stability and spectrophotometric titration

Rosales Hoz, Ma T. Leticia January 1975 (has links)
No description available.
3

Studies in photometric analysis including design and construction of a full-immersion photometer

Speights, Robert Milton 08 1900 (has links)
No description available.
4

The photometric determination of palladium with 4-(2-pyridylazo) resorcinol

Hicks, Jackson Earl 12 1900 (has links)
No description available.
5

The electronic structure of square-planar nickel(ii) and copper(ii) complexes

Schievelbein, Vernon Hugo 08 1900 (has links)
No description available.
6

Lead, zinc, and copper (II) complexes of 4-(2-pyridylazo)-resorcinol in aqueous solution : their identification, stability and spectrophotometric titration

Rosales Hoz, Ma T. Leticia January 1975 (has links)
No description available.
7

The spectrophotometric determination of metals with Chloroindazon DS and Chloroindazon C.

January 1977 (has links)
Thesis (M.Phil.)--The Chinese University of Hong Kong. / Bibliography: leaf 88.
8

The application of the photometric end point to chelometric titrations for the resolution of mixtures of metal ions

Ganchoff, John Christopher 12 1900 (has links)
No description available.
9

Synthesis, photophysical and biological studies of lanthanide complexes for photodynamic therapy

Zhou, Yan 14 September 2017 (has links)
1.2\xPrior to the PDT, we have also synthesized a series of water-soluble homoleptic lanthanides (Ln3+ = Gd, Er, and Yb) sandwich (DD) di-PEGylated porphyrin complexes. The Yb complex (YbDD) has shown the same NIR emission quantum yield as the highest record Yb complex in the literature (Yb-RhB), yet, the emission intensity is double compared to the Yb-N. This implies a new thinking about the quantity measurement for biological imaging. The brightness might be the prime factor for the development of luminescence in vitro/in vivo imaging agent rather than the emission quantum yield.
10

Ligand isotope vibrational studies of metal(II) complexes with particular reference to heterocyclic N-oxides

Watkins, Gareth Mostyn January 1987 (has links)
Includes bibliographical references. / A critical examination of the characteristic N-O vibrational frequencies of aromatic N-oxides questions the widely held assignment of αN-O (840cm⁻¹) and YN-O (47oon- 1). The present investigation supports the assignments of αN-O (470cm⁻¹) and γN-O (280cm⁻¹), with the assignment of the band at 840cm⁻¹ as being vring coupled with νN-O.