• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Removal of Cu2 +, Cd2 + and Zn2 + using silica spheres functionalized with EDTA: batch and column study / RemoÃÃo de Cu2+, Cd2+ e Zn2+ utilizando esferas de sÃlica funcionalizada com EDTA: estudo em batelada e coluna

Diego de Quadros Melo 27 January 2012 (has links)
FundaÃÃo Cearense de Apoio ao Desenvolvimento Cientifico e TecnolÃgico / Matrizes inorgÃnicas tÃm sido utilizadas como materiais adsorventes para remoÃÃo de poluentes quÃmicos em sistemas aquÃticos, dada Ãs suas boas capacidades de adsorÃÃo e estabilidades fÃsicas e quÃmicas Neste trabalho, foi sintetizado esferas de sÃlica funcionalizadas com EDTA com a finalidade de remover Ãons metÃlicos em soluÃÃo aquosa. A cinÃtica de adsorÃÃo dos Ãons em estudo (Cu2+, Cd2+ e Zn2+) foi feita em pH 5,5 numa concentraÃÃo de 60 mg L-1, onde se observou que o equilÃbrio à atingido extremamente rÃpido, cerca de 10 minutos, o que indica que a etapa limitante do processo de adsorÃÃo pode ser a quimissorÃÃo, evidenciado pelos melhores ajustes para o modelo de pseudo-segunda ordem. As isotermas de adsorÃÃo foram submetidas ao modelo linear e nÃo linear para efeito de comparaÃÃo, utilizando o R2 e funÃÃo erro SSE como referencia. O estudo com sistema simples e multielementar dos Ãons foi realizado em pH 5,5, concentraÃÃes variando de 10-300 mg L-1, onde os dados foram submetidos aos modelos de Langmuir, Freundlich, Temkin e Redlich-Peterson. Os resultados evidenciaram um melhor ajuste para o modelo de Langmuir, o qual defende que os sÃtios de adsorÃÃo sÃo homogÃneos e adsorÃÃo à em monocamada. As capacidades mÃximas de adsorÃÃo observadas nos estudos de equilÃbrio para o sistema mono e multielementar seguem a ordem Cu2+> Zn2+> Cd2+. Para efeito de comparaÃÃo de modelos foi utilizado o mÃtodo de AKAIKEÂS onde comprovou que os resultados se ajustam melhor ao modelo de Langmuir. Com respeito ao estudo de adsorÃÃo em coluna, as curvas de ruptura indicaram que a saturaÃÃo da mesma ocorre num volume de 35 mL. O uso do eluente HCl 0,1 M, permitiu recuperar 100% dos Ãons adsorvidos. A coluna foi utilizada por trÃs ciclos para verificar seu potencial de uso, e foi comprovado que nos trÃs ciclos consegue-se recuperar 100% dos metais, o que significa uma Ãtima eficiÃncia das esferas de sÃlica-APTS-EDTA. / Inorganic matrices have been used as adsorbent mate rial for removal of chemical pollutants in aquatic systems, due to its good adsorption capacity for physical and chemical stabilities and this work was synthesized silica spheres functionalized with EDTA in order to remove metal i ons in aqueous solution . The kinetics of adsorption of the ions under study (Cu 2 + , Cd 2 + and Zn 2 + ) was performed at pH 5.5 at a concentration of 60 mg L -1 , where it was observed that equilibrium is reached very fast, about 10 minutes, indicating tha t limiting step of the adsorption process may be the chemisorption, as evidenced by t he best fitting model for the pseudo-second order. The adsorption isotherms were subjected to linear and nonlinear model for comparison, using the error fun ction SSE and R 2 as a reference. The study of simple and multielement ions was carri ed out at pH 5.5, concentrations ranging from 10-300 mg L -1 , where the data were submitted to the models of Langmuir, Freundlich, Temkin and Redlich-Peterson. The results showed a better fit to the Langmuir model, which argues that the adsorp tion sites are homogeneous and monolayer adsorption. The maximum sorption capaciti es observed in studies of equilibrium for the system mono and multielement fo llow the order Cu 2 + > Zn 2 + > Cd 2+. For comparison model method was used Akaike's whe re proved that the Langmuir model is the best. With respect to the stu dy of adsorption column, the breakthrough curves indicate that saturation occurs in the same volume of 35 mL. The use of the eluent 0.1 M HCl, allowed to recover 100% of the adsorbed ions. The column was used for three cycles to verify their po tential use, and it was proved that in the three-cycles can recover 100% of the metals, which means an optimum efficiency of the spheres of silica-APTS-EDTA.

Page generated in 0.0549 seconds