• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

"Resistência de união, ao ensaio de microtração, de selante e sistemas adesivos aplicados em superfícies oclusais de molares decíduos" / Micro-tensile bond strength of sealant and adhesive systems applied on occlusal surfaces of primary molars.

Ramires-Romito, Ana Cláudia Durante 31 March 2005 (has links)
O objetivo deste estudo foi avaliar a resistência de união, ao ensaio de microtração, de selante (Clinpro, 3M) e sistemas adesivos (OptiBond FL, Kerr; OptiBond Solo, Kerr; OptiBond Solo Self-Etch Adhesive System (SE), Kerr) aplicados em superfícies oclusais de molares decíduos (n=32). Os produtos avaliados foram testados após serem aplicados de acordo com as recomendações dos fabricantes e após contaminação da superfície oclusal com saliva. Após armazenagem em água por 24h a 37ºC, cada dente foi secionado no plano mésio-distal e perpendicularmente à interface de união para obtenção de corpos-de-prova em forma de palito com seção transversal retangular e área aproximada de 0,6 mm 2 . Cada corpo-de-prova foi submetido ao teste de tração em máquina de ensaio universal a uma velocidade de 0,5 mm/min e os fragmentos armazenados para análise posterior do padrão de fratura em microscopia eletrônica de varredura. As fraturas foram classificadas em: adesiva mista, tipo 1 (fratura tanto de material restaurador, isto é associação de adesivo/resina composta, como do esmalte e o substrato predominante foi esmalte); adesiva mista, tipo 2 (fratura tanto de material restaurador como do esmalte e o substrato predominante foi o material restaurador); adesiva mista, tipo 3 (fratura tanto de material restaurador como do esmalte e houve distribuição homogênea de ambos); mista tipo 4 (fratura apenas de material restaurador, isto é, adesivo associado à resina composta) e; coesiva tipo 5 (fratura coesiva exclusivamente de um do substratos sendo esmalte ou resina composta). A análise estatística dos dados obtidos, relativos à resistência de união, usou como unidade experimental o dente. Os palitos perdidos em cada grupo foram incluídos no cálculo de resistência de cada dente. A contaminação salivar não influe nciou a perda de palitos. Não houve associação entre o padrão de fratura e os valores de resistência de união. As fraturas foram predominantemente mistas, não foi observada fratura coesiva exclusivamente de esmalte ou resina composta. Para os sistemas adesivos testados, nenhuma diferença significante foi observada entre os grupos com contaminação salivar ou não. OptiBond FL (34,5 ± 2,2 MPa) e Clinpro (45,1 ± 3,2 MPa) apresentaram valores de resistência de união similares e significativamente maiores do que o OptiBond Solo Plus (19,1 ± 2,3 MPa) e OptiBond Solo SE (9,8 ± 2,3 MPa) que foram equivalentes entre eles (p > 0,05). / The aim of this study was to evaluate the micro-tensile bond strength (mTBS) of a conventional sealant (Clinpro, 3M) and adhesive systems (OptiBond FL, Kerr; OptiBond Solo, Kerr; OptiBond Solo Self-Etch Adhesive System (SE), Kerr) on occlusal surface of primary molars (n=32). Sealant and adhesives were tested under manufacturers’ specifications and after contamination of the bonding site with saliva. After storage in distilled water at 37 º C for 24 h, the specimens were longitudinally sectioned perpendicular to the adhesive interface. Stick shape samples with cross-sectional areas of about 0.6 mm 2 were obtained and subjected to a tensile force in a universal testing machine at a crosshead speed of 0.5 mm/min. The bond failure modes were evaluated at scanning electron microscope and classified as following: mixed, type 1 (with cohesive failure of the neighboring substrates, wherein enamel was predominant); mixed, type 2 (with cohesive failure of the neighboring substrates, wherein adhesive/resin composite was predominant); mixed, type 3 (with cohesive failure of the neighboring substrates, wherein enamel and adhesive/resin composite was equally distributed); mixed, type 4 (with cohesive failure of the neighboring substrates, where there was only adhesive and resin composite, with none enamel fracture); cohesive, type 5 (failure exclusive within enamel or resin composite). The mean value of bond strength was calculated for each of the four teeth used per group, meaning that the experimental unit was the tooth. These were averaged to express the mean bond strength for every material at each group. The specimens lost due to pre-testing failure were included in the calculus of the mTBS of each tooth. Moisture did not influence sticks loss. There was not any association between failure mode and values of mTBS. The majority of fractures were mixed, none cohesive failure of enamel or composite resin was observed. For the tested adhesive systems no significant difference was observed between the groups under either saliva contamination or not. OptiBond FL (34.5 ± 2.2 MPa) and Clinpro (45.1 ± 3.2 MPa) showed similar values of mTBS and significantly higher than OptiBond Solo Plus (19.1 ± 2.3 MPa) and OptiBond Solo SE (9.8 ± 2.3 MPa) that were equivalent to each other (p>0.05).
2

"Resistência de união, ao ensaio de microtração, de selante e sistemas adesivos aplicados em superfícies oclusais de molares decíduos" / Micro-tensile bond strength of sealant and adhesive systems applied on occlusal surfaces of primary molars.

Ana Cláudia Durante Ramires-Romito 31 March 2005 (has links)
O objetivo deste estudo foi avaliar a resistência de união, ao ensaio de microtração, de selante (Clinpro, 3M) e sistemas adesivos (OptiBond FL, Kerr; OptiBond Solo, Kerr; OptiBond Solo Self-Etch Adhesive System (SE), Kerr) aplicados em superfícies oclusais de molares decíduos (n=32). Os produtos avaliados foram testados após serem aplicados de acordo com as recomendações dos fabricantes e após contaminação da superfície oclusal com saliva. Após armazenagem em água por 24h a 37ºC, cada dente foi secionado no plano mésio-distal e perpendicularmente à interface de união para obtenção de corpos-de-prova em forma de palito com seção transversal retangular e área aproximada de 0,6 mm 2 . Cada corpo-de-prova foi submetido ao teste de tração em máquina de ensaio universal a uma velocidade de 0,5 mm/min e os fragmentos armazenados para análise posterior do padrão de fratura em microscopia eletrônica de varredura. As fraturas foram classificadas em: adesiva mista, tipo 1 (fratura tanto de material restaurador, isto é associação de adesivo/resina composta, como do esmalte e o substrato predominante foi esmalte); adesiva mista, tipo 2 (fratura tanto de material restaurador como do esmalte e o substrato predominante foi o material restaurador); adesiva mista, tipo 3 (fratura tanto de material restaurador como do esmalte e houve distribuição homogênea de ambos); mista tipo 4 (fratura apenas de material restaurador, isto é, adesivo associado à resina composta) e; coesiva tipo 5 (fratura coesiva exclusivamente de um do substratos sendo esmalte ou resina composta). A análise estatística dos dados obtidos, relativos à resistência de união, usou como unidade experimental o dente. Os palitos perdidos em cada grupo foram incluídos no cálculo de resistência de cada dente. A contaminação salivar não influe nciou a perda de palitos. Não houve associação entre o padrão de fratura e os valores de resistência de união. As fraturas foram predominantemente mistas, não foi observada fratura coesiva exclusivamente de esmalte ou resina composta. Para os sistemas adesivos testados, nenhuma diferença significante foi observada entre os grupos com contaminação salivar ou não. OptiBond FL (34,5 ± 2,2 MPa) e Clinpro (45,1 ± 3,2 MPa) apresentaram valores de resistência de união similares e significativamente maiores do que o OptiBond Solo Plus (19,1 ± 2,3 MPa) e OptiBond Solo SE (9,8 ± 2,3 MPa) que foram equivalentes entre eles (p > 0,05). / The aim of this study was to evaluate the micro-tensile bond strength (mTBS) of a conventional sealant (Clinpro, 3M) and adhesive systems (OptiBond FL, Kerr; OptiBond Solo, Kerr; OptiBond Solo Self-Etch Adhesive System (SE), Kerr) on occlusal surface of primary molars (n=32). Sealant and adhesives were tested under manufacturers’ specifications and after contamination of the bonding site with saliva. After storage in distilled water at 37 º C for 24 h, the specimens were longitudinally sectioned perpendicular to the adhesive interface. Stick shape samples with cross-sectional areas of about 0.6 mm 2 were obtained and subjected to a tensile force in a universal testing machine at a crosshead speed of 0.5 mm/min. The bond failure modes were evaluated at scanning electron microscope and classified as following: mixed, type 1 (with cohesive failure of the neighboring substrates, wherein enamel was predominant); mixed, type 2 (with cohesive failure of the neighboring substrates, wherein adhesive/resin composite was predominant); mixed, type 3 (with cohesive failure of the neighboring substrates, wherein enamel and adhesive/resin composite was equally distributed); mixed, type 4 (with cohesive failure of the neighboring substrates, where there was only adhesive and resin composite, with none enamel fracture); cohesive, type 5 (failure exclusive within enamel or resin composite). The mean value of bond strength was calculated for each of the four teeth used per group, meaning that the experimental unit was the tooth. These were averaged to express the mean bond strength for every material at each group. The specimens lost due to pre-testing failure were included in the calculus of the mTBS of each tooth. Moisture did not influence sticks loss. There was not any association between failure mode and values of mTBS. The majority of fractures were mixed, none cohesive failure of enamel or composite resin was observed. For the tested adhesive systems no significant difference was observed between the groups under either saliva contamination or not. OptiBond FL (34.5 ± 2.2 MPa) and Clinpro (45.1 ± 3.2 MPa) showed similar values of mTBS and significantly higher than OptiBond Solo Plus (19.1 ± 2.3 MPa) and OptiBond Solo SE (9.8 ± 2.3 MPa) that were equivalent to each other (p>0.05).
3

"Influência do volume de adesivo e das ciclagens térmica e mecânica na resistência de união resina-dentina" / Influence of the adhesive volume, thermal and mechanical load cycling on the resin-dentin bond strength

Lodovici, Edmea 01 July 2005 (has links)
Interfaces adesivas flexíveis, com maior capacidade de dissipação de tensões poderiam prevenir falhas provenientes das tensões geradas durante a contração de polimerização, variações térmicas e esforços mastigatórios. Isso poderia ser obtido através do aumento da espessura da camada de adesivo. O objetivo deste trabalho foi comparar a resistência de união (RU) à dentina de dois sistemas adesivos (SA) aplicados com diferentes volumes de adesivo (uma ou duas camadas) e submetidos ou não às ciclagens térmica e mecânica (CTM). A superfície dentinária de 40 terceiros molares hígidos foi exposta com uma lixa de granulação 600. Dois sistemas adesivos foram testados: Scotchbond Multiuso (SBMU) e Clearfil SE Bond (CSEB). Seus respectivos adesivos foram aplicados através de uma micropipeta (8 ou 16µl) em uma área delimitada de 52 mm 2 e blocos de resina composta (Z250) foram construídos incrementalmente. Metade da amostra foi armazenada em água destilada por 24 h e submetida às ciclagens térmica (1.000; 5-55ºC) e mecânica (500.000 ciclos / 12 kgf). A outra metade foi apenas armazenada em água destilada por 72 h. Após isso, os dentes foram seccionados, longitudinalmente, em cortes perpendiculares entre si, a fim de se obterem corpos-de-prova em formato de paralelogramo com aproximadamente 0,8mm 2 de secção transversal. Os palitos foram submetidos ao teste de microtração a 1,0 mm/min e o modo de fratura analisado. A RU foi expressa como um índice que incluiu os valores de RU dos diferentes padrões de fratura, além dos palitos prematuramente fraturados (P). Os dados foram submetidos à análise de variância de 3 fatores. O teste de qui-quadrado foi utilizado (p<0,05) para verificar diferenças na freqüência de P. Dois fatores foram significantes: “SA" e “CTM". SBMU e grupos não-ciclados apresentaram maior RU do que CSEB e grupos ciclados respectivamente. Uma maior freqüência de P foi observada para os grupos ciclados. Uma camada adicional de adesivo não influenciou na RU de interfaces feitas com SBMU ou CSEB, enquanto a CTM levou à redução da RU das interfaces. / Dentin bonding interfaces with increased capacity of stress dissipation are able to prevent failures due to polymerization contraction, thermal and mechanical stresses. This would be obtained by increasing adhesive layer thickness. The purpose of this study was to compare the resin-dentin microtensile bond strengths (BS) of two adhesive systems (AS) applied with different volumes of adhesive resin (one and two coats) submitted or not to thermal and mechanical loading (TML). A flat superficial dentin surface was exposed on 40 third molars with a 600-grit SiC paper. Two systems were tested: Scotchbond Multipurpose (SBMP) and Clearfil SE Bond (CSEB). After primer application, the adhesive layer was applied by a micropipette (8 or 16µl) to a delimited area (52mm 2 ) and resin blocks (Z250) were built incrementally. Half of the sample was stored in distilled water for 24h and then submitted to thermal (1,000; 5-55ºC) and mechanical cycles (500,000; 12kgf). The other half was stored in distilled water (72h). Teeth were then sectioned to obtain sticks (0.8 mm 2 ) to be tested under tensile mode (1.0mm/min). The fracture mode was analyzed at 400X. BS was expressed as an index that included the BS values of different fracture patterns and the prematurely debonded specimens (D). The data was analyzed by three-way ANOVA. The &#967; 2 test was used (p<0.05) to compare the frequency of D specimens. The main factors AS and TML were significant. SBMP and non-cycled groups showed higher BS to dentin. A higher frequency of D was observed for the cycled groups. The application of an adhesive layer in two coats for a three-step etch&rinse and a two-step self-etch systems, to act as an intermediate flexible layer, was not able to minimize the damage caused by thermal and mechanical load in a low C-factor cavity.
4

Degradação de interfaces adesivas formadas após desmineralização e desproteinização da dentina / Long-term bond strengths of adhesive systems applied to etched and deproteinized dentin

Gómez, Ninoshka Uceda 07 December 2007 (has links)
O objetivo deste estudo foi avaliar a resistência de união de 2 sistemas adesivos convencionais de dois passos (Single Bond-SB, 3MESPE e One Step-OS, Bisco) aplicados à dentina desmineralizada [SH] e desmineralizada e desproteinizada com NaOCl a 10% [CH], tanto no tempo imediato [IM] como após 12 meses de imersão em água [12M]. Realizou-se também a observação da morfologia das interfaces de união entre os sistemas adesivos e a superfície de dentina em Microscópio Eletrônico de Varredura (MEV) para cada grupo experimental. O esmalte oclusal de 20 molares permanentes hígidos foi removido para expor as superfícies planas de dentina, que foram condicionadas com H3PO4 a 37%, lavadas e secas (grupos SH). Para os grupos CH após o condicionamento ácido foi aplicado hipoclorito de sódio a 10% durante 60 s, seguido de lavagem por 15 s. Os sistemas adesivos foram aplicados de acordo com as recomendações dos fabricantes. Coroas de resina composta (Z-250, 3MESPE) foram construídas de forma incremental (600 mW/cm² por 40 s). Após armazenagem em água por 24h a 37°C, os espécimes foram secionados para obter corpos-de-prova na forma de palitos (0,8mm²), que foram testados sob tração (0,5 mm/min) no tempo imediato [IM] ou após 12 meses de armazenamento em água. Dois dentes de cada grupo foram observados em MEV nos dois períodos de tempo. Os dados de resistência de união foram submetidos à uma análise de variância de três fatores e teste de Tukey para contraste das médias (p = 0,05). As interações duplas e triplas não foram estatisticamente significantes (p> 0,05), assim como o fator principal Tratamento de superfície (p = 0,05). Somente os fatores principais Adesivo e Tempo de armazenagem foram significantes (p = 0,04 e p = 0,03, respectivamente). O adesivo SB (43,3 ± 9,1 MPa) apresentou altos valores de resistência de união quando comparado com o OS (33,3 ± 11,6 MPa). A resistência de união do grupo IM (42,5 ± 8,7) foi estatisticamente superior à grupo 12M (33,3 ± 11,8). / The aim of this study was to evaluate the early and 12-month bond strengths of two adhesive systems (Single Bond-SB, 3MESPE and One Step-OS, Bisco) applied to demineralized dentin (WH) and demineralized/NaOCl-treated dentin (H). The adhesive interfaces were also micromorphologically evaluated by Scanning Electron Microscopy (SEM). Twenty flat dentin surfaces were exposed. They were etched, rinsed and slightly dried. For the H groups, a solution of 10% NaOCl was applied for 60s, rinsed (15 s) and slightly dried. The adhesives were applied according to the manufacturer\'s instructions and composite resin crowns were incrementally constructed. After 24 h (water-37°C), the sample was sectioned in order to obtain resin-dentin sticks (0.8 mm²). The specimens were tested in tension (0.5 mm/min) immediately (IM) or after 12 months of water storage (12M). Two teeth from each experimental group were restored as described previously and evaluated under SEM, under the two storage periods. The data (MPa) were subjected to three-way ANOVA and Tukey\'s test (? = 0.05). No significant effects for the triple and double interactions (p > 0.05) as well as for the main factor Surface treatment were observed (p > 0.05). Only the main factors Adhesive and Storage time were statistically significant (p = 0.004 and p = 0.003, respectively). The adhesive SB (42.3 ± 9.1) showed higher bond strengths than OS (33.6 ± 11.6). The mean bond strength for IM-group (42.5 ± 8.7) was statistically superior to 12M (33.3 ± 11.8). The use of 10% sodium hypochlorite, after acid etching, did not improve the immediate and the long term resin-dentin bond strengths for acetone and water/alcohol based adhesive systems.
5

Degradação de interfaces adesivas formadas após desmineralização e desproteinização da dentina / Long-term bond strengths of adhesive systems applied to etched and deproteinized dentin

Ninoshka Uceda Gómez 07 December 2007 (has links)
O objetivo deste estudo foi avaliar a resistência de união de 2 sistemas adesivos convencionais de dois passos (Single Bond-SB, 3MESPE e One Step-OS, Bisco) aplicados à dentina desmineralizada [SH] e desmineralizada e desproteinizada com NaOCl a 10% [CH], tanto no tempo imediato [IM] como após 12 meses de imersão em água [12M]. Realizou-se também a observação da morfologia das interfaces de união entre os sistemas adesivos e a superfície de dentina em Microscópio Eletrônico de Varredura (MEV) para cada grupo experimental. O esmalte oclusal de 20 molares permanentes hígidos foi removido para expor as superfícies planas de dentina, que foram condicionadas com H3PO4 a 37%, lavadas e secas (grupos SH). Para os grupos CH após o condicionamento ácido foi aplicado hipoclorito de sódio a 10% durante 60 s, seguido de lavagem por 15 s. Os sistemas adesivos foram aplicados de acordo com as recomendações dos fabricantes. Coroas de resina composta (Z-250, 3MESPE) foram construídas de forma incremental (600 mW/cm² por 40 s). Após armazenagem em água por 24h a 37°C, os espécimes foram secionados para obter corpos-de-prova na forma de palitos (0,8mm²), que foram testados sob tração (0,5 mm/min) no tempo imediato [IM] ou após 12 meses de armazenamento em água. Dois dentes de cada grupo foram observados em MEV nos dois períodos de tempo. Os dados de resistência de união foram submetidos à uma análise de variância de três fatores e teste de Tukey para contraste das médias (p = 0,05). As interações duplas e triplas não foram estatisticamente significantes (p> 0,05), assim como o fator principal Tratamento de superfície (p = 0,05). Somente os fatores principais Adesivo e Tempo de armazenagem foram significantes (p = 0,04 e p = 0,03, respectivamente). O adesivo SB (43,3 ± 9,1 MPa) apresentou altos valores de resistência de união quando comparado com o OS (33,3 ± 11,6 MPa). A resistência de união do grupo IM (42,5 ± 8,7) foi estatisticamente superior à grupo 12M (33,3 ± 11,8). / The aim of this study was to evaluate the early and 12-month bond strengths of two adhesive systems (Single Bond-SB, 3MESPE and One Step-OS, Bisco) applied to demineralized dentin (WH) and demineralized/NaOCl-treated dentin (H). The adhesive interfaces were also micromorphologically evaluated by Scanning Electron Microscopy (SEM). Twenty flat dentin surfaces were exposed. They were etched, rinsed and slightly dried. For the H groups, a solution of 10% NaOCl was applied for 60s, rinsed (15 s) and slightly dried. The adhesives were applied according to the manufacturer\'s instructions and composite resin crowns were incrementally constructed. After 24 h (water-37°C), the sample was sectioned in order to obtain resin-dentin sticks (0.8 mm²). The specimens were tested in tension (0.5 mm/min) immediately (IM) or after 12 months of water storage (12M). Two teeth from each experimental group were restored as described previously and evaluated under SEM, under the two storage periods. The data (MPa) were subjected to three-way ANOVA and Tukey\'s test (? = 0.05). No significant effects for the triple and double interactions (p > 0.05) as well as for the main factor Surface treatment were observed (p > 0.05). Only the main factors Adhesive and Storage time were statistically significant (p = 0.004 and p = 0.003, respectively). The adhesive SB (42.3 ± 9.1) showed higher bond strengths than OS (33.6 ± 11.6). The mean bond strength for IM-group (42.5 ± 8.7) was statistically superior to 12M (33.3 ± 11.8). The use of 10% sodium hypochlorite, after acid etching, did not improve the immediate and the long term resin-dentin bond strengths for acetone and water/alcohol based adhesive systems.
6

"Influência do volume de adesivo e das ciclagens térmica e mecânica na resistência de união resina-dentina" / Influence of the adhesive volume, thermal and mechanical load cycling on the resin-dentin bond strength

Edmea Lodovici 01 July 2005 (has links)
Interfaces adesivas flexíveis, com maior capacidade de dissipação de tensões poderiam prevenir falhas provenientes das tensões geradas durante a contração de polimerização, variações térmicas e esforços mastigatórios. Isso poderia ser obtido através do aumento da espessura da camada de adesivo. O objetivo deste trabalho foi comparar a resistência de união (RU) à dentina de dois sistemas adesivos (SA) aplicados com diferentes volumes de adesivo (uma ou duas camadas) e submetidos ou não às ciclagens térmica e mecânica (CTM). A superfície dentinária de 40 terceiros molares hígidos foi exposta com uma lixa de granulação 600. Dois sistemas adesivos foram testados: Scotchbond Multiuso (SBMU) e Clearfil SE Bond (CSEB). Seus respectivos adesivos foram aplicados através de uma micropipeta (8 ou 16µl) em uma área delimitada de 52 mm 2 e blocos de resina composta (Z250) foram construídos incrementalmente. Metade da amostra foi armazenada em água destilada por 24 h e submetida às ciclagens térmica (1.000; 5-55ºC) e mecânica (500.000 ciclos / 12 kgf). A outra metade foi apenas armazenada em água destilada por 72 h. Após isso, os dentes foram seccionados, longitudinalmente, em cortes perpendiculares entre si, a fim de se obterem corpos-de-prova em formato de paralelogramo com aproximadamente 0,8mm 2 de secção transversal. Os palitos foram submetidos ao teste de microtração a 1,0 mm/min e o modo de fratura analisado. A RU foi expressa como um índice que incluiu os valores de RU dos diferentes padrões de fratura, além dos palitos prematuramente fraturados (P). Os dados foram submetidos à análise de variância de 3 fatores. O teste de qui-quadrado foi utilizado (p<0,05) para verificar diferenças na freqüência de P. Dois fatores foram significantes: “SA” e “CTM”. SBMU e grupos não-ciclados apresentaram maior RU do que CSEB e grupos ciclados respectivamente. Uma maior freqüência de P foi observada para os grupos ciclados. Uma camada adicional de adesivo não influenciou na RU de interfaces feitas com SBMU ou CSEB, enquanto a CTM levou à redução da RU das interfaces. / Dentin bonding interfaces with increased capacity of stress dissipation are able to prevent failures due to polymerization contraction, thermal and mechanical stresses. This would be obtained by increasing adhesive layer thickness. The purpose of this study was to compare the resin-dentin microtensile bond strengths (BS) of two adhesive systems (AS) applied with different volumes of adhesive resin (one and two coats) submitted or not to thermal and mechanical loading (TML). A flat superficial dentin surface was exposed on 40 third molars with a 600-grit SiC paper. Two systems were tested: Scotchbond Multipurpose (SBMP) and Clearfil SE Bond (CSEB). After primer application, the adhesive layer was applied by a micropipette (8 or 16µl) to a delimited area (52mm 2 ) and resin blocks (Z250) were built incrementally. Half of the sample was stored in distilled water for 24h and then submitted to thermal (1,000; 5-55ºC) and mechanical cycles (500,000; 12kgf). The other half was stored in distilled water (72h). Teeth were then sectioned to obtain sticks (0.8 mm 2 ) to be tested under tensile mode (1.0mm/min). The fracture mode was analyzed at 400X. BS was expressed as an index that included the BS values of different fracture patterns and the prematurely debonded specimens (D). The data was analyzed by three-way ANOVA. The &#967; 2 test was used (p<0.05) to compare the frequency of D specimens. The main factors AS and TML were significant. SBMP and non-cycled groups showed higher BS to dentin. A higher frequency of D was observed for the cycled groups. The application of an adhesive layer in two coats for a three-step etch&rinse and a two-step self-etch systems, to act as an intermediate flexible layer, was not able to minimize the damage caused by thermal and mechanical load in a low C-factor cavity.

Page generated in 0.0846 seconds