1

Avaliação microbiológica de circuitos respiratórios e anestésicos submetidos ao processo de desinfecção térmica

Oliveira, Andréa Ranucci 12 April 2012 (has links)
Made available in DSpace on 2016-01-26T12:51:48Z (GMT). No. of bitstreams: 1 andrearanuccideoliveira_dissert.pdf: 891643 bytes, checksum: 8f4fb2c47edb543f3ffbf41be6a1179a (MD5) Previous issue date: 2012-04-12 / Introduction: The reprocessing and reuse of medical practices are common in health care institutions in Brazil and several countries. However, it is necessary to establish parameters to guide the development, validation and implementation of reprocessing protocols, in order to ensure product quality and safety and health of patients. This conduct is an important infection control action, because microorganisms can remain in reprocessed medical supplies and cause a wide variety of infectious processes. Objective: To evaluate the efficiency of thermal disinfection procedure adopted for the reprocessing of breathing circuit used in anesthesia and mechanical ventilation in two hospitals in São José do Rio Preto, SP. Method: We performed microbiological tests for the detection, identification, assessment of antimicrobial susceptibility of microorganisms from the respiratory and anesthetic circuits termodesinfetados in two hospitals. Results: The Hospital identified in two samples coagulase-negative Staphylococcus and Pseudomonas aeruginosa, samples of Enterococcus spp termodesinfectadora identified, water samples were found P. aeruginosa and Citrobacter freundii, yeasts and Gram-negative bacilli. In hospital B samples showed contamination with Gram positive samples subjected to drying and termosesinfecção were contaminated by Acinetobacter calcoaceticus. Samples collected from the inner surfaces of the dryer were isolated A. calcoaceticus, A. baumannii, and Achromobacter xylosoxidans. Conclusion: We note that the thermal disinfection process was not efficient for the elimination of pathogens in peer-reviewed articles and drying equipment can act as contaminants after the disinfection process. / Introdução: O reprocessamento e reuso de artigos odonto médicos hospitalares são práticas comuns em instituições de assistência à saúde do Brasil e de diversos outros países. Entretanto, é necessário o estabelecimento de parâmetros que orientem a elaboração, validação e implantação de protocolos de reprocessamento, visando garantir a qualidade dos produtos e a segurança e saúde dos pacientes. Esta conduta é uma importante ação de controle de infecções, pois microrganismos podem permanecer em artigos médicos reprocessados e causar grande diversidade de processos infecciosos. Objetivo: Avaliar a eficiência do procedimento de termodesinfecção adotado para o reprocessamento dos circuitos respiratórios utilizados em ventilação mecânica e anestesia em dois hospitais do município de São José do Rio Preto, SP. Método: Foram realizadas análises microbiológicas para a detecção, identificação e avaliação da sensibilidade aos antimicrobianos, de microrganismos a partir dos circuitos anestésicos e respiratórios termodesinfetados nos dois hospitais. Resultados: No Hospital A foram identificados em duas amostras dos circuitos respiratórios Staphylococcus coagulase negativo e Pseudomonas aeruginosa, nas amostras da termodesinfectadora identificado Enterococcus spp, nas amostras da água foram encontrados P. aeruginosa e Citrobacter freundii, leveduras e bacilos Gram-negativos. No hospital B as amostras dos circuitos anestésicos apresentaram contaminação por bacilos Gram positivos, nas amostras submetidas a termosesinfecção e secagem recuperarou-ser Acinetobacter calcoaceticus. Nas amostras coletadas das superfícies internas da secadora foram isoladas A. calcoaceticus, A. baumannii e Achromobacter xylosoxidans. Conclusão: Observamos que o processo de termodesinfecção não foi eficiente para a eliminação de patógenos nos artigos avaliados e equipamentos de secagem podem atuar como contaminantes após o processo de desinfecção.
2

Avaliação in vitro da infiltração bacteriana na interface implante/componente protético em conexões dos tipos cone morse e hexágono interno / In vitro evaluation of bacterial leakage at the implant abutment interface in types of connections Morse Taper and Internal Hexagon

Teixeira, Wendel 03 September 2009 (has links)
A precisão na fabricação de um implante pode ser verificada pelo grau de adaptação na interface implante/componente protético. Uma pobre adaptação permite a infiltração de microrganismos através dessa interface e a colonização dos espaços vazios dos implantes, levando ao surgimento de reações inflamatórias dos tecidos periimplantares e ao insucesso clínico do tratamento. O objetivo deste trabalho foi avaliar, in vitro, a infiltração de uma bactéria, o Staphylococcus aureus, através da interface implante/componente protético, pelo método de cultura bacteriana. Foram utilizados vinte conjuntos de implantes Cone Morse, com os Pilares CM (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo A, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo B, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Foram utilizados também vinte conjuntos de implantes Titamax II Plus, com os Mini Pilares Cônicos II Plus (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo C, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo D, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Na avaliação da infiltração bacteriana de dentro para fora dos implantes, foi feita a inoculação da bactéria na parte interna dos implantes, e estes mergulhados em tubos de ensaio contendo um meio de enriquecimento estéril. Para avaliação da infiltração bacteriana de fora para dentro dos implantes, os conjuntos implantes/componentes foram mergulhados em tubos de ensaio contendo um meio de enriquecimento com cepas da bactéria. Ocorreu infiltração bacteriana em todos os grupos, e não houve diferença estatisticamente significante entre os grupos A e C, nem entre os grupos B e D, em relação à percentagem da passagem do microrganismo na interface implante/componente protético. / The precision in the manufacture of an implant can be determined by the degree of adaptation at the abutment-implant interface. A poor adaptation allows the infiltration of microorganisms through this interface and colonization of empty spaces of the implants, leading to inflammatory reactions and clinical failure of treatment. The aim of the present in-vitro study was to investigate leakage of Staphylococcus aureus through the abutment-implant interface, by the method of bacterial culture. It was used twenty sets of Morse Taper implants with Pillars CM (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group A, which were evaluated for bacterial infiltration into the inner part of the implants, and Group B, which were evaluated for bacterial infiltration from the inner part of the implants. Were also used twenty sets of Titamax II Plus implants, with the conical Mini Pillars II Plus (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group C, which were evaluated for bacterial infiltration into the inner part of the implants and Group D, which were evaluated for bacterial infiltration from the inner part of the implants. In the evaluation of bacterial infiltration from the implants, the assemblies had the inner parts inoculated with S. aureus, and each assembly was incubated in BHI broth. For assessment of bacterial leakage into the implants, each assembly was submerged in S. aureus culture in tubes. Bacterial infiltration occurred in all groups, and there was no statistically significant difference between groups A and C, or between groups B and D.
3

Avaliação in vitro da infiltração bacteriana na interface implante/componente protético em conexões dos tipos cone morse e hexágono interno / In vitro evaluation of bacterial leakage at the implant abutment interface in types of connections Morse Taper and Internal Hexagon

Wendel Teixeira 03 September 2009 (has links)
A precisão na fabricação de um implante pode ser verificada pelo grau de adaptação na interface implante/componente protético. Uma pobre adaptação permite a infiltração de microrganismos através dessa interface e a colonização dos espaços vazios dos implantes, levando ao surgimento de reações inflamatórias dos tecidos periimplantares e ao insucesso clínico do tratamento. O objetivo deste trabalho foi avaliar, in vitro, a infiltração de uma bactéria, o Staphylococcus aureus, através da interface implante/componente protético, pelo método de cultura bacteriana. Foram utilizados vinte conjuntos de implantes Cone Morse, com os Pilares CM (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo A, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo B, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Foram utilizados também vinte conjuntos de implantes Titamax II Plus, com os Mini Pilares Cônicos II Plus (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo C, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo D, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Na avaliação da infiltração bacteriana de dentro para fora dos implantes, foi feita a inoculação da bactéria na parte interna dos implantes, e estes mergulhados em tubos de ensaio contendo um meio de enriquecimento estéril. Para avaliação da infiltração bacteriana de fora para dentro dos implantes, os conjuntos implantes/componentes foram mergulhados em tubos de ensaio contendo um meio de enriquecimento com cepas da bactéria. Ocorreu infiltração bacteriana em todos os grupos, e não houve diferença estatisticamente significante entre os grupos A e C, nem entre os grupos B e D, em relação à percentagem da passagem do microrganismo na interface implante/componente protético. / The precision in the manufacture of an implant can be determined by the degree of adaptation at the abutment-implant interface. A poor adaptation allows the infiltration of microorganisms through this interface and colonization of empty spaces of the implants, leading to inflammatory reactions and clinical failure of treatment. The aim of the present in-vitro study was to investigate leakage of Staphylococcus aureus through the abutment-implant interface, by the method of bacterial culture. It was used twenty sets of Morse Taper implants with Pillars CM (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group A, which were evaluated for bacterial infiltration into the inner part of the implants, and Group B, which were evaluated for bacterial infiltration from the inner part of the implants. Were also used twenty sets of Titamax II Plus implants, with the conical Mini Pillars II Plus (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group C, which were evaluated for bacterial infiltration into the inner part of the implants and Group D, which were evaluated for bacterial infiltration from the inner part of the implants. In the evaluation of bacterial infiltration from the implants, the assemblies had the inner parts inoculated with S. aureus, and each assembly was incubated in BHI broth. For assessment of bacterial leakage into the implants, each assembly was submerged in S. aureus culture in tubes. Bacterial infiltration occurred in all groups, and there was no statistically significant difference between groups A and C, or between groups B and D.
4

Avaliação in vitro das interfaces dos implantes Cone Morse e Hexágono Interno / In vitro evaluation of the interfaces of the Morse Taper implants and Internal hexagon implants.

Brosco, Roberta Pires Dias 29 January 2014 (has links)
Objetivo: Considerando que a precisão na adaptação do implante ao intermediário transmucoso é fator importante para a longevidade da prótese e que os sistemas de implantes possuem origens diversas na sua fabricação, nos propusemos a verificar a infiltração da bactéria Enterococcus faecalis na interface entre intermediário transmucoso e implantes do tipo Cone Morse e Hexágono Interno no sistema Neodent . Material e Método: A amostra foi composta por 20 implantes do tipo Cone Morse com Index Protético, 20 implantes Titamax Cone Morse e 20 implantes de Hexágono Interno e 20 intermediários transmucosos do tipo Munhão Universal CM Exact, 20 Munhão Universal em corpo único de 3,3 x 5,5 mm e 20 Munhão Universal II Plus com Parafuso. Com o auxílio da Micropipeta o Inóculo foi aspirado, imediatamente após, inserido no interior do implante que se encontrava estático na placa do Dispositivo desenvolvido para este experimento. Os intermediários foram então conectados e apertados com chave digital própria, em seguida, foi dado o torque ao parafuso do intermediário de acordo com as recomendações do fabricante. Após o torque o conjunto, implante-intermediário foi removido da placa do Dispositivo com pinça de titânio e inserido dentro do tubo de ensaio que continha o meio de cultura estéril. Diante do conhecimento da área interna de cada implante, o volume do Inóculo a ser utilizado foi determinado em 1L. Todos os tubos contendo os conjuntos foram numerados e incubados a 37oC por um período de 14 dias. Foi realizado acompanhamento diário para verificação da possível passagem de bactérias do interior do implante para o caldo. O indicativo da passagem de bactéria para o meio foi a turvação do meio de cultura (caldo BHI). Decorrido os 14 dias de observação, os dados foram tabulados e submetidos à Análise de Variância (ANOVA) com nível de significância de 5%, quando detectada diferença estatística, os valores foram submetidos ao Teste de Tuckey para comparações múltiplas. Resultados: O Teste de Tukey evidenciou que houve diferença estatisticamente significante entre o grupo de implantes Cone Morse, Cone Morse Índex e Hexágono Interno, onde o grupo de implantes Cone Morse diferiu estatisticamente do grupo Cone Morse Índex e também do grupo de implantes de Hexágono Interno. O grupo de implantes Cone Morse Índex não diferiu estatisticamente do grupo de implantes de Hexágono Interno, porém o grupo Cone Morse Índex presentou os melhores resultados. / Objective: Whereas the accuracy adaptation of the implant abutment is an important factor for the longevity of the prosthesis, and implant systems have diverse backgrounds in its manufacture, we set out to verify the infiltration of Enterococcus faecalis bacteria at the interface between the abutment and transmucosal implants of Morse Taper and Internal Hex of Neodent system. Material and Methods: The sample consisted of 20 Morse Taper implants, 20 Titamax Morse Taper implants, 20 Internal Hexagon implants and 20 transmucosal Exact CM Universal Post abutment, 20 Universal Post 3 in one body , 3 x 5.5mm and 20 Universal Post II Plus with Screw . With the aid of a micropipette the inoculum was aspirated, immediately thereafter, inserted into the implant that was in the static device board developed for this experiment. The abutments were then connected and tightened to own digital key, then the torque was given to the screw of the abutment according to the manufacturer\'s recommendations. After the torque, deploy abutment was removed from the plate clamp device of titanium and inserted into a test tube containing sterile culture. According to the internal area of each implant, the inoculum size was determined to be 1L. All the tubes were numbered and incubated at 37 ° C for a period of 14 days. Daily monitoring to check the possible passage of bacteria into the interior of the implant broth was carried out. The indication of the passage of bacteria was turbidity of the culture (BHI). Upon expiry of the 14 days of observation, the data were tabulated and an analysis of variance (ANOVA) with a significance level of 5 % was done. The values were submitted to Tukey test for multiple comparisons. Results: The Tukey test showed a statistically significant difference between the group of Morse Taper implants, Cone Morse Index and Internal Hex, where the group of implants differed from Morse Taper, Morse Taper Index group and also the group of Internal Hexagon implants. The group of Morse Taper implants Index did not differ statistically from the group of Internal hexagon implants, but Morse Taper Index group showed the best results
5

Avaliação in vitro das interfaces dos implantes Cone Morse e Hexágono Interno / In vitro evaluation of the interfaces of the Morse Taper implants and Internal hexagon implants.

Roberta Pires Dias Brosco 29 January 2014 (has links)
Objetivo: Considerando que a precisão na adaptação do implante ao intermediário transmucoso é fator importante para a longevidade da prótese e que os sistemas de implantes possuem origens diversas na sua fabricação, nos propusemos a verificar a infiltração da bactéria Enterococcus faecalis na interface entre intermediário transmucoso e implantes do tipo Cone Morse e Hexágono Interno no sistema Neodent . Material e Método: A amostra foi composta por 20 implantes do tipo Cone Morse com Index Protético, 20 implantes Titamax Cone Morse e 20 implantes de Hexágono Interno e 20 intermediários transmucosos do tipo Munhão Universal CM Exact, 20 Munhão Universal em corpo único de 3,3 x 5,5 mm e 20 Munhão Universal II Plus com Parafuso. Com o auxílio da Micropipeta o Inóculo foi aspirado, imediatamente após, inserido no interior do implante que se encontrava estático na placa do Dispositivo desenvolvido para este experimento. Os intermediários foram então conectados e apertados com chave digital própria, em seguida, foi dado o torque ao parafuso do intermediário de acordo com as recomendações do fabricante. Após o torque o conjunto, implante-intermediário foi removido da placa do Dispositivo com pinça de titânio e inserido dentro do tubo de ensaio que continha o meio de cultura estéril. Diante do conhecimento da área interna de cada implante, o volume do Inóculo a ser utilizado foi determinado em 1L. Todos os tubos contendo os conjuntos foram numerados e incubados a 37oC por um período de 14 dias. Foi realizado acompanhamento diário para verificação da possível passagem de bactérias do interior do implante para o caldo. O indicativo da passagem de bactéria para o meio foi a turvação do meio de cultura (caldo BHI). Decorrido os 14 dias de observação, os dados foram tabulados e submetidos à Análise de Variância (ANOVA) com nível de significância de 5%, quando detectada diferença estatística, os valores foram submetidos ao Teste de Tuckey para comparações múltiplas. Resultados: O Teste de Tukey evidenciou que houve diferença estatisticamente significante entre o grupo de implantes Cone Morse, Cone Morse Índex e Hexágono Interno, onde o grupo de implantes Cone Morse diferiu estatisticamente do grupo Cone Morse Índex e também do grupo de implantes de Hexágono Interno. O grupo de implantes Cone Morse Índex não diferiu estatisticamente do grupo de implantes de Hexágono Interno, porém o grupo Cone Morse Índex presentou os melhores resultados. / Objective: Whereas the accuracy adaptation of the implant abutment is an important factor for the longevity of the prosthesis, and implant systems have diverse backgrounds in its manufacture, we set out to verify the infiltration of Enterococcus faecalis bacteria at the interface between the abutment and transmucosal implants of Morse Taper and Internal Hex of Neodent system. Material and Methods: The sample consisted of 20 Morse Taper implants, 20 Titamax Morse Taper implants, 20 Internal Hexagon implants and 20 transmucosal Exact CM Universal Post abutment, 20 Universal Post 3 in one body , 3 x 5.5mm and 20 Universal Post II Plus with Screw . With the aid of a micropipette the inoculum was aspirated, immediately thereafter, inserted into the implant that was in the static device board developed for this experiment. The abutments were then connected and tightened to own digital key, then the torque was given to the screw of the abutment according to the manufacturer\'s recommendations. After the torque, deploy abutment was removed from the plate clamp device of titanium and inserted into a test tube containing sterile culture. According to the internal area of each implant, the inoculum size was determined to be 1L. All the tubes were numbered and incubated at 37 ° C for a period of 14 days. Daily monitoring to check the possible passage of bacteria into the interior of the implant broth was carried out. The indication of the passage of bacteria was turbidity of the culture (BHI). Upon expiry of the 14 days of observation, the data were tabulated and an analysis of variance (ANOVA) with a significance level of 5 % was done. The values were submitted to Tukey test for multiple comparisons. Results: The Tukey test showed a statistically significant difference between the group of Morse Taper implants, Cone Morse Index and Internal Hex, where the group of implants differed from Morse Taper, Morse Taper Index group and also the group of Internal Hexagon implants. The group of Morse Taper implants Index did not differ statistically from the group of Internal hexagon implants, but Morse Taper Index group showed the best results