Development of Monte Carlo track structure simulations for protons and carbon ions in water

Liamsuwan, Thiansin January 2012 (has links)
The goal of radiation therapy is to eradicate tumour cells while minimising radiation dose to healthy tissues. Ions including protons and carbon ions have gained increasing interest for cancer treatment. Advantages of ion beam therapy are conformal dose distribution, and for ions heavier than protons increased biological effectiveness in cell killing, compared to conventional radiation therapy using photons. Despite these advantages, fundamental problems in ion beam therapy include accuracy of dose determination at the cellular level, and characterisation of the radiation quality at the microscopic scale. Due to the high density of interactions along ion tracks, inhomogeneity of dose and track parameters at the cellular level is one of the major concerns for ion beam therapy. The aim of the thesis is to develop computational tools for dosimetry of ion tracks at the molecular level. Event-by-event Monte Carlo track structure (MCTS) simulations were developed for full-slowing-down tracks of protons and carbon ions in water representing cellular environment. In Paper I, the extension of the MCTS code KURBUC_proton was carried out to energies up to 300 MeV, covering the entire proton energy range used in radiation therapy. Physical properties and microdosimetry of proton tracks were investigated and benchmarked with the experimental data. Papers II-V describe the development of the MCTS code for full-slowing-down tracks of carbon ions. In Papers II-IV, the classical trajectory Monte Carlo (CTMC) model was developed for the calculation of interaction cross sections for low and intermediate energy carbon projectiles of all charge states (C0 to C6+) in water. In Paper V, the calculated cross sections were implemented in a new MCTS code KURBUC_carbon simulating carbon ions of energies 1-104 keV/u in water. This development allows the investigation of track parameters in the Bragg peak region of carbon ion beams. Publication of the thesis and the published papers make contribution to the physics of ion interactions in matter, and provide a new and complete database of electronic interaction cross sections for low and intermediate energy carbon projectiles of all charge states in water. The MCTS codes for protons and carbon ions provide new tools for biophysical study, including microdosimetry, of ion tracks at cellular and subcellular levels, in particular in the Bragg peak region of these ions. / <p>At the time of the doctoral defense, the following papers were unpublished and had a status as follows: Paper 4: Submitted. Paper 5: Submitted.</p><p> </p>
32

Monte Carlo microdosimetry of charged-particle microbeam irradiations / Micro-dosimétrie d'irradiations par microfaisceau d'ions par méthodes Monte-Carlo

Torfeh, Eva 01 October 2019 (has links)
L’interaction des particules chargées avec la matière conduit à un dépôt d’énergie très localisé dans des traces de dimensions sub-micrométriques. Cette propriété unique rend ce type de rayonnement ionisant particulièrement intéressant pour disséquer les mécanismes moléculaires radio-induits suite à l’échelle de la cellule. L’utilisation de microfaisceaux de particules chargées offre en outre la capacité d’irradier sélectivement à l’échelle du micromètre avec une dose contrôlée jusqu’à la particule unique. Mon travail a porté sur des irradiations réalisées avec le microfaisceau de particules chargées de la plateforme AIFIRA (Applications Interdisciplinaires des Faisceaux d’Ions en Région Aquitaine) du CENBG. Ce microfaisceau délivre des protons et particules alpha et est dédié aux irradiations ciblées in vitro (cellules humains) et in vivo (C. elegans).En complément de l’intérêt qu’elles présentent pour des études expérimentales, les dépôts d’énergie et les interactions des particules chargées avec la matière peuvent être modélisés précisément tout au long de leur trajectoire en utilisant des codes de structures de traces basés sur des méthodes Monte Carlo. Ces outils de simulation permettent une caractérisation précise de la micro-dosimétrie des irradiations allant de la description détaillée des interactions physiques à l’échelle nanométrique jusqu’à la prédiction du nombre de dommages à l’ADN et leurs distributions dans l’espace.Au cours de ma thèse, j’ai développée des modèles micro-dosimétriques basés sur l’outil de modélisation Geant4-DNA dans deux cas. Le premier concerne la simulation de la distribution d’énergie déposée dans un noyau cellulaire et le calcul du nombre des différents types de dommages ADN (simple et double brin) aux échelles nanométrique et micrométrique, pour différents types et nombres de particules délivrées. Ces résultats sont confrontés à la mesure expérimentale de la cinétique de protéines de réparation de l’ADN marquées par GFP (Green Fluorescent Protein) dans des cellules humaines. Le second concerne la dosimétrie de l’irradiation d’un organisme multicellulaire dans le cadre d’études de l’instabilité génétique dans un organisme vivant au cours du développement (C. elegans). J’ai simulé la distribution de l’énergie déposée dans différents compartiments d’un modèle réaliste en 3D d’un embryon de C. elegans suite à des irradiations par protons. Enfin, et en parallèle de ces deux études, j’ai développé un protocole pour caractériser le microfaisceau d'AIFIRA à l’aide de détecteurs de traces fluorescent (FNTD) pour des irradiations par protons et par particules alpha. Ce type de détecteur permet en effet de visualiser les trajectoires des particules incidentes avec une résolution de l’ordre de 200 nm et d’examiner la qualité des irradiations cellulaires réalisées par le microfaisceau. / The interaction of charged particles with matter leads to a very localized energy deposits in sub-micrometric tracks. This unique property makes this type of ionizing radiation particularly interesting for deciphering the radiation-induced molecular mechanisms at the cell scale. Charged particle microbeams (CPMs) provide the ability to target a given cell compartment at the micrometer scale with a controlled dose down to single particle. My work focused on irradiations carried out with the CPM at the AIFIRA facility in the CENBG (Applications Interdisciplinaires des Faisceaux d’Ions en Région Aquitaine). This microbeam delivers protons and alpha particles and is dedicated to targeted irradiation in vitro (human cells) and in vivo (C. elegans).In addition to their interest for experimental studies, the energy deposits and the interactions of charged particles with matter can be modeled precisely along their trajectory using track structure codes based on Monte Carlo methods. These simulation tools allow a precise characterization of the micro-dosimetry of the irradations from the detailed description of the physical interactions at the nanoscale to the prediction of the number of DNA damage, their complexity and their distribution in space.During my thesis, I developed micro-dosimetric models based on the Geant4-DNA modeling toolkit in two cases. The first concerns the simulation of the energy distribution deposited in a cell nucleus and the calculation of the number of different types of DNA damage (single and double strand breaks) at the nanometric and micrometric scales, for different types and numbers of delivered particles. These simulations are compared with experimental measurements of the kinetics of GFP-labeled (Green Fluorescent Protein) DNA repair proteins in human cells. The second is the dosimetry of irradiation of a multicellular organism to study the genetic instability in a living organism during development (C. elegans). I simulated the distribution of the energy deposited in different compartments of a realistic 3D model of a C. elegans embryo following proton irradiations. Finally, and in parallel with these two studies, I developed a protocol to characterize the AIFIRA microbeam using fluorescent nuclear track detector (FNTD) for proton and alpha particle irradiations. This type of detector makes it possible to visualize in 3D the incident particle tracks with a resolution of about 200 nm and to examine the quality of the cellular irradiations carried out by the CPM.
33

Development of an Advanced Two-Dimensional Microdosimetric Detector based on THick Gas Electron Multipliers / Development of an Advanced 2D THGEM Microdosimetric Detector

Darvish-Molla, Sahar January 2016 (has links)
The THick Gas Electron Multiplier (THGEM) based tissue-equivalent proportional counter (TEPC) has been proven to be useful for microdosimetry due to its flexibility in varying the gaseous sensitive volume and achieving high multiplication gain. Aiming at measuring the spatial distribution of radiation dose for mixed neutron-gamma fields, an advanced two-dimensional (2D) THGEM TEPC was designed and constructed at McMaster University which will enable us to overcome the operational limitation of the classical TEPCs, particularly for high dose rate fields. Compared to the traditional TEPCs, anode wire electrodes were replaced by THGEM layer, which not only enhances the gas multiplication gain but also offers a flexible and convenient fabrication or building 2D detectors. The 2D THGEM TEPC consists of an array of 3×3 sensitive volumes, equivalent to 9 individual TEPCs, each of which has a dimension of 5 mm diameter and length. Taking the overall cost, size and flexibility into account, to process 9 detectors signals simultaneously, a multi-input digital pulse processing system was developed by using modern microcontrollers, each of which is coupled to a 12-bit sampling ADC with a sampling rate of 42 Msps. The signal processing system was tested using a NaI(Tl) detector, which has proven that is it faster than a traditional analogue system and a commercial digital system. Using the McMaster Tandetron 7Li(p,n) accelerator neutron source, both fundamental detector performance, as well as neutron dosimetric response of the 2D THGEM TEPC, has been extensively investigated and compared to the data acquired by a spherical TEPC. It was shown that the microdosimetric response and the measured absorbed dose rate of the 2D THGEM detector developed in this study are comparable to the standard 1/2" TEPC which is commercially available. / Thesis / Doctor of Philosophy (PhD)
34

Nanoparticle-aided Radiation Therapy: Micro-dosimetry and Evaluation of the Mediators Producing Biological Damage

Paudel, Nava R. January 2014 (has links)
No description available.
35

Micro-irradiation ciblée par faisceau d'ions pour la radiobiologie in vitro et in vivo / In vitro and in vivo ion beam targeted micro-irradiation for radiobiology

Vianna, François 26 March 2014 (has links)
Les microfaisceaux d’ions ont, au cours de ces dernières décennies, montré leur efficacité dansl’étude des effets des rayonnements ionisants sur le vivant notamment concernant les effets des faiblesdoses ou l’étude de l’effet de proximité. Le CENBG dispose depuis 2003 d’un dispositif permettant la micro-irradiation ciblée d’échantillons biologiques vivants. Les applications des microfaisceaux dans ce domainese sont récemment diversifiées et des études plus fines sur les mécanismes de réparation desdommages ADN radio-induits aux échelles cellulaire et multicellulaire sont devenues possibles via lesévolutions en imagerie par fluorescence et en biologie cellulaire. Ces approches ont nécessité une évolutionimportante de l'instrumentation de la ligne de micro-irradiation du CENBG qui a été entièrementredessinée et reconstruite dans un souci d’optimisation d’apport de nouvelles fonctionnalités. Les objectifsde mes travaux ont été i) la mise en service du dispositif, ii) la caractérisation des performances dusystème, iii) la mise en place de protocoles pour l’irradiation ciblée à dose contrôlée aux échelles cellulaireet multicellulaire, in vitro et in vivo, et le suivi en ligne des conséquences précoces de cette irradiation,iv) la modélisation des irradiations afin d’interpréter les observables biologiques au regard des donnéesphysiques calculées.Ces travaux ont permis i) de caractériser les performances du dispositif : une taille de faisceau d’environ2 μm sur cible et une précision de tir de ± 2 μm, de développer des systèmes de détection d’ions pour uncontrôle absolu de la dose délivrée, ii) d’induire des dommages ADN fortement localisés in vitro, et devisualiser en ligne le recrutement de protéines impliquées dans la réparation de ces dommages,iii) d’appliquer ces protocoles pour générer des dommages ADN in vivo au sein d’un organisme multicellulaireau stade embryonnaire, Caenorhabditis elegans.Ces résultats ouvrent la voie vers des expériences plus fines sur la ligne de micro-irradiation ciblée duCENBG pour étudier les effets de l’interaction des rayonnements ionisants avec le vivant, aux échellescellulaire et multicellulaire, in vitro et in vivo. / The main goal of radiobiology is to understand the effects of ionizing radiations on the living.These past decades, ion microbeams have shown to be important tools to study for example the effects oflow dose exposure, or the bystander effect. Since 2003, the CENBG has been equipped with a system toperform targeted micro-irradiation of living samples. Recently, microbeams applications on this subjecthave diversified and the study of DNA repair mechanisms at the cellular and multicellular scales, in vitroand in vivo, has become possible thanks to important evolutions of fluorescence imaging techniques andcellular biology. To take into account these new approaches, the CENBG micro-irradiation beamline hasbeen entirely redesigned and rebuilt to implement new features and to improve the existing ones. My PhDobjectives were i) commissioning the facility, ii) characterizing the system on track etch detectors, and onliving samples, iii) implementing protocols to perform targeted irradiations of living samples with a controlleddelivered dose, at the cellular and multicellular scales, and to visualize the early consequencesonline, iv) modelling these irradiations to explain the biological results using the calculated physical data.The work of these past years has allowed us i) to measure the performances of our system: a beam spotsize of about 2 μm and a targeting accuracy of ± 2 μm, and to develop ion detection systems for an absolutedelivered dose control, ii) to create highly localized radiation-induced DNA damages and to see onlinethe recruitment of DNA repair proteins, iii) to apply these protocols to generate radiation-induced DNAdamages in vivo inside a multicellular organism at the embryonic stage: Caenorhabditis elegans.These results have opened up many perspectives on the study of the interaction between ionizing radiationsand the living, at the cellular and multicellular scales, in vitro and in vivo.