Spelling suggestions: "subject:"microgrid inverter"" "subject:"microgrids inverter""
1 |
Controle robusto de inversores VSI com filtro LCL aplicados a geração distribuída, com controle da injeção de potências ativa e reativa na rede de distribuição em baixa tensão e capacidade de operação ilhada em ambiente de microrredes / Robust control of voltage source inverters with LCL filters suitable for distributed generation, with control of the injection of active and reactive power on the low voltage distribution network and capability to operate in islanded mode in microgrid scenarioPena, José Carlos Ugaz [UNESP] 02 June 2016 (has links)
Submitted by JOSÉ CARLOS UGAZ PEÑA null (josecarlos84@gmail.com) on 2016-06-20T13:29:30Z
No. of bitstreams: 1
Tese_JoseCarlosPena_PPGEE.pdf: 9650212 bytes, checksum: 77b105d009c0b473cbc424e681ebe9a5 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-06-22T13:10:00Z (GMT) No. of bitstreams: 1
pena_jcu_dr_ilha.pdf: 9650212 bytes, checksum: 77b105d009c0b473cbc424e681ebe9a5 (MD5) / Made available in DSpace on 2016-06-22T13:10:00Z (GMT). No. of bitstreams: 1
pena_jcu_dr_ilha.pdf: 9650212 bytes, checksum: 77b105d009c0b473cbc424e681ebe9a5 (MD5)
Previous issue date: 2016-06-02 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Os inversores fonte de tensão com filtro de saída LCL (VSI+LCL) são amplamente utilizados em sistemas de geração distribuída. Nestas aplicações o sistema é controlado como uma fonte de corrente, no entanto, há a possibilidade de controlar o conjunto como uma fonte de tensão. Desta forma, a mencionada configuração pode ser utilizada em geração distribuída no ambiente de microrredes onde os sistemas, monofásicos ou trifásicos, devem operar conectados à rede de distribuição elétrica com controle das potências injetadas (ativa e reativa) e serem capazes de, em ausência da rede, passar a operar no modo autônomo. Ainda, após o restabelecimento da rede, o controle deve levar o sistema a operar novamente no modo conectado. Sendo as transições realizadas sem transientes que possam danificar qualquer componente do sistema. O filtro LCL, de terceira ordem, caracteriza um comportamento ressonante que pode comprometer a estabilidade do sistema. Para resolver esta situação, diversas técnicas ativas e passivas são aplicadas. Para aplicações de baixa potência, preferem-se as técnicas passivas de amortecimento devido a sua simplicidade e baixo custo, porém estas implicam em perdas adicionais. Já as técnicas ativas de amortecimento, consideram procedimentos de controle para atenuar a ressonância, e, portanto, não adicionam perdas, porém, sua realização requer da realimentação de variáveis adicionais elevando assim o custo do sistema. Todavia, mesmo que aplicáveis a ambos os modos de operação, as técnicas de amortecimento disponíveis na literatura consideram apenas um modo de operação. O presente trabalho de doutorado explora a possibilidade de controlar sistemas VSI+LCL, monofásicos e trifásicos, em ambos os modos de operação, com atenção a objetivos específicos em cada modo e transições suaves entre estes. Assim, são apresentadas duas estratégias de controle. A primeira estratégia considera o amortecimento da ressonância por técnicas passivas, mediante a utilização de um ramo de amortecimento de segunda ordem, projetado para garantir o efeito desejado em ambos os modos de operação e simplificar a dinâmica do sistema a fim de facilitar o projeto dos controladores, abordagem não utilizada nos métodos conhecidos na literatura. Logo, o sistema amortecido é controlado em uma configuração de duas malhas, controlando a corrente injetada mediante a tensão no capacitor. A segunda estratégia proposta considera a utilização de controladores por realimentação de estados em tempo discreto, sintetizados mediante desigualdades matriciais lineares, para simultaneamente, realizar ativamente o amortecimento da ressonância e atender os objetivos de controle em ambos os modos de operação. Ambas as estratégias propostas consideram controladores ressonantes com o objetivo de rastrear sinais senoidais de referência com erro nulo e suprimir componentes harmônicos de baixa ordem na corrente de saída. Ainda, os controladores são projetados considerando a necessidade de garantir a estabilidade robusta do sistema, isto é, frente a perturbações externas (tais como variações na carga local, oscilações na tensão do barramento CC ou distúrbios na rede) e às variações em parâmetros do sistema, como a indutância de rede. As propostas são apresentadas em detalhe, incluindo os procedimentos de projeto assim como critérios para a geração e coordenação dos sinais de controle e referência. As estratégias propostas são avaliadas experimentalmente sendo os resultados obtidos discutidos e analisados considerando-se as respectivas normas para os casos de operação conectada e ilhada. / The voltage source inverter utilization with LCL filters (VSI+LCL) is extended in Distributed Electrical Energy Systems. In these applications, the system is controlled as a current source, however, it can also be controlled as a voltage source. Hence, this configuration is suitable for microgrids environment. In this scenario, the system should operate connected to utility grid with control of the supplied power (active or reactive) and also be capable, in case of grid absence, to operate in islanded mode. Then, if the grid is reestablished, system should be reconnected to grid. Moreover, these transitions should be smooth, with no hazardous transients. The third order filter leads to a resonant behavior that can compromise the system stability. In order to overcome this limitation, passive and active damping methods are used. In low power applications, passive damping methods are preferred due to their simplicity and low. Nevertheless, these methods lead to additional losses. On the other hand, active damping methods consider the feedback of additional variables in order to damp the resonance in closed loop, with no additional losses. This implies additional sensors, thus increasing the overall cost. Despite their effectiveness to damp the resonance in both autonomous and grid connected applications, the most of the damping methods are usually designed only for a specific operation mode. This work explores the possibility to control VSI+LCL systems, single and three-phase, in both operation modes, attending to specific goals in each one, and with smooth transitions between them. For that purpose, two control strategies are proposed. The first one considers passive damping methods, by using a second order damping branch which is designed in order to guarantee the desired effect in both operation modes, thus simplifying the system dynamics in order to ease the control. This approach is not known in the literature. Then, the damped system is controlled in a two loop strategy, where the output current is controlled by means of the capacitor voltage. The second strategy considers the utilization of discrete time state-feedback controllers, synthesized by Linear Matrix Inequalities, in order to simultaneously achieve the active damping and the control goals for both operation modes. The proposed strategies use resonant controllers in order to achieve the tracking of sinusoidal references and to suppress low order harmonics in the output current. Moreover, controllers are designed to achieve robust stability of the system, thus, even in front of external disturbances (such as local load variations, DC bus oscillations or grid disturbances) and variation on system parameters, such as the grid inductance. The two introduced strategies are detailed including the design procedure and the criterion to generate and coordinate the reference and control signals. The two proposed strategies were experimentally verified. The results were analyzed and compared to the requirements imposed by the related standards for both modes of operation. / CNPq: 141757/2012-4
|
2 |
Controle robusto de inversores VSI com filtro LCL aplicados a geração distribuída, com controle da injeção de potências ativa e reativa na rede de distribuição em baixa tensão e capacidade de operação ilhada em ambiente de microrredes /Pena, José Carlos Ugaz January 2016 (has links)
Orientador: Carlos Alberto Canesin / Resumo: Os inversores fonte de tensão com filtro de saída LCL (VSI+LCL) são amplamente utilizados em sistemas de geração distribuída. Nestas aplicações o sistema é controlado como uma fonte de corrente, no entanto, há a possibilidade de controlar o conjunto como uma fonte de tensão. Desta forma, a mencionada configuração pode ser utilizada em geração distribuída no ambiente de microrredes onde os sistemas, monofásicos ou trifásicos, devem operar conectados à rede de distribuição elétrica com controle das potências injetadas (ativa e reativa) e serem capazes de, em ausência da rede, passar a operar no modo autônomo. Ainda, após o restabelecimento da rede, o controle deve levar o sistema a operar novamente no modo conectado. Sendo as transições realizadas sem transientes que possam danificar qualquer componente do sistema. O filtro LCL, de terceira ordem, caracteriza um comportamento ressonante que pode comprometer a estabilidade do sistema. Para resolver esta situação, diversas técnicas ativas e passivas são aplicadas. Para aplicações de baixa potência, preferem-se as técnicas passivas de amortecimento devido a sua simplicidade e baixo custo, porém estas implicam em perdas adicionais. Já as técnicas ativas de amortecimento, consideram procedimentos de controle para atenuar a ressonância, e, portanto, não adicionam perdas, porém, sua realização requer da realimentação de variáveis adicionais elevando assim o custo do sistema. Todavia, mesmo que aplicáveis a ambos os modos de operação,... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The voltage source inverter utilization with LCL filters (VSI+LCL) is extended in Distributed Electrical Energy Systems. In these applications, the system is controlled as a current source, however, it can also be controlled as a voltage source. Hence, this configuration is suitable for microgrids environment. In this scenario, the system should operate connected to utility grid with control of the supplied power (active or reactive) and also be capable, in case of grid absence, to operate in islanded mode. Then, if the grid is reestablished, system should be reconnected to grid. Moreover, these transitions should be smooth, with no hazardous transients. The third order filter leads to a resonant behavior that can compromise the system stability. In order to overcome this limitation, passive and active damping methods are used. In low power applications, passive damping methods are preferred due to their simplicity and low. Nevertheless, these methods lead to additional losses. On the other hand, active damping methods consider the feedback of additional variables in order to damp the resonance in closed loop, with no additional losses. This implies additional sensors, thus increasing the overall cost. Despite their effectiveness to damp the resonance in both autonomous and grid connected applications, the most of the damping methods are usually designed only for a specific operation mode. This work explores the possibility to control VSI+LCL systems, single and three-phase... (Complete abstract click electronic access below) / Doutor
|
Page generated in 0.0637 seconds