• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 5
  • Tagged with
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A influência do corte com diferentes discos e velocidades na integridade dos espécimes e na resistência adesiva de uma cerâmica a um cimento resinoso dual em ensaio de microtração / The influence of different cutting speeds and brand of diamond saws on integrity of microtensile specimes and Bond strenght values

Martha Chiabai Cupertino de Castro 19 November 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Esta pesquisa estudou a influência de diferentes velocidades de corte e marcas de discos diamantados nos valores de resistência adesiva, durante a preparação dos espécimes a serem submetidos à microtração, e na integridade das amostras por meio do microscópio eletrônico de varredura (MEV). Vinte blocos da cerâmica à base de dissilicato de lítio (IPS e.max Press) foram unidos com cimento resinoso (Rely X ARC) a blocos de compósito (Z100), construídos incrementalmente. Foram seguidas as recomendações dos fabricantes no tratamento da superfície da cerâmica e aplicação do cimento resinoso. Após 24 horas em água destilada a 37C, os espécimes foram divididos em dois grupos de discos: marcas Buehler e Extec e subdivididos nas velocidades de 200rpm e 400rpm (B2; E2; B4 e E4, respectivamente). Cada espécime foi cortado em dois eixos perpendiculares para obtenção de palitos com área adesiva de 1,0mm. Para cada condição experimental, os palitos foram separados, aleatoriamente, 15 palitos para análise ao MEV e 30 palitos para serem submetidos à força de tração. As médias de resistência adesiva em MPa foram E4=20,312 ; B4= 24,2 11,3 ; B2= 25,2 9,0 e E2= 28,6 10,4. Na análise estatística, observou-se que os valores de resistência adesiva na velocidade de 200rpm foram significativamente maiores comparados a velocidade de 400rpm, independente do disco empregado. Ao MEV, observou-se melhor integridade dos palitos na velocidade de 200rpm com presença de trincas menos extensas nas bordas externas. Constatou-se também que o disco Extec na velocidade de 400rpm apresentou movimentos excêntricos ao corte e obteve-se maior número de perdas prematuras, uma diminuição significante na média da área total de união (p<0,05), além de diferença significativa nos valores de resistência comparada a velocidade de 200rpm. Concluiu-se que a utilização de diferentes velocidades e sua interação com o disco empregado interfere na integridade dos espécimes e nos valores de resistência adesiva, sendo mais acentuada ao se utilizar o disco da marca Extec. / The aim of this research was to verify the influence of different cutting speeds and brand of diamond saws during microtensile specimen preparation on the bonding strength values and on the samples microscopy integrity (SEM). Twenty lithium disilicate glass-ceramic blocks (IPS e.max Press) were bonded with dual-cure resin cement (Rely X ARCTM) to composite (Z100TM) blocks, built incrementally. The manufacturers recommendations were followed for ceramic treatment surface and placement on the resin cement, as well. After storage for 24 hours in distillated water at 37C, the specimens were divided in two groups of diamond saws, Buehler and Extec brands, which were further subdivided using 200rpm and 400rpm speeds (B2; E2; B4 and E4 respectively), and they were sectioned into two perpendicular axes obtaining sticks shaped specimens with cross-sectional area of 1.0mm. For each experimental situation the sticks were randomly separated; 15 for the analysis to the SEM and 30 to be submitted to tensile strength. Mean bond strength values (MPa) were: E4 = 20.3 12; B4 = 24.2 11.3; B2 = 25.2 9.0; and E2 = 28.6 10.4. The statistical analysis of data showed that the values of bond strength at 200 rpm speed were significantly higher as compared to 400 rpm speed, regardless of saw employed. In SEM, it was noted better integrity of sticks at 200 rpm speed with presence of less extensive cracks in external edges. It was also found that the Extec saw at 400 rpm showed eccentric movement to cutting and achieved higher number of premature losses, a significant decreased mean total area of bond (p<0.05), in addition to significant difference in strength values compared with 200 rpm speed. It was concluded that using different speeds and their interaction with the used saw interfere with the integrity of specimens and the bond strength values, being more pronounced when using the Extec saw.
2

A influência do corte com diferentes discos e velocidades na integridade dos espécimes e na resistência adesiva de uma cerâmica a um cimento resinoso dual em ensaio de microtração / The influence of different cutting speeds and brand of diamond saws on integrity of microtensile specimes and Bond strenght values

Martha Chiabai Cupertino de Castro 19 November 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Esta pesquisa estudou a influência de diferentes velocidades de corte e marcas de discos diamantados nos valores de resistência adesiva, durante a preparação dos espécimes a serem submetidos à microtração, e na integridade das amostras por meio do microscópio eletrônico de varredura (MEV). Vinte blocos da cerâmica à base de dissilicato de lítio (IPS e.max Press) foram unidos com cimento resinoso (Rely X ARC) a blocos de compósito (Z100), construídos incrementalmente. Foram seguidas as recomendações dos fabricantes no tratamento da superfície da cerâmica e aplicação do cimento resinoso. Após 24 horas em água destilada a 37C, os espécimes foram divididos em dois grupos de discos: marcas Buehler e Extec e subdivididos nas velocidades de 200rpm e 400rpm (B2; E2; B4 e E4, respectivamente). Cada espécime foi cortado em dois eixos perpendiculares para obtenção de palitos com área adesiva de 1,0mm. Para cada condição experimental, os palitos foram separados, aleatoriamente, 15 palitos para análise ao MEV e 30 palitos para serem submetidos à força de tração. As médias de resistência adesiva em MPa foram E4=20,312 ; B4= 24,2 11,3 ; B2= 25,2 9,0 e E2= 28,6 10,4. Na análise estatística, observou-se que os valores de resistência adesiva na velocidade de 200rpm foram significativamente maiores comparados a velocidade de 400rpm, independente do disco empregado. Ao MEV, observou-se melhor integridade dos palitos na velocidade de 200rpm com presença de trincas menos extensas nas bordas externas. Constatou-se também que o disco Extec na velocidade de 400rpm apresentou movimentos excêntricos ao corte e obteve-se maior número de perdas prematuras, uma diminuição significante na média da área total de união (p<0,05), além de diferença significativa nos valores de resistência comparada a velocidade de 200rpm. Concluiu-se que a utilização de diferentes velocidades e sua interação com o disco empregado interfere na integridade dos espécimes e nos valores de resistência adesiva, sendo mais acentuada ao se utilizar o disco da marca Extec. / The aim of this research was to verify the influence of different cutting speeds and brand of diamond saws during microtensile specimen preparation on the bonding strength values and on the samples microscopy integrity (SEM). Twenty lithium disilicate glass-ceramic blocks (IPS e.max Press) were bonded with dual-cure resin cement (Rely X ARCTM) to composite (Z100TM) blocks, built incrementally. The manufacturers recommendations were followed for ceramic treatment surface and placement on the resin cement, as well. After storage for 24 hours in distillated water at 37C, the specimens were divided in two groups of diamond saws, Buehler and Extec brands, which were further subdivided using 200rpm and 400rpm speeds (B2; E2; B4 and E4 respectively), and they were sectioned into two perpendicular axes obtaining sticks shaped specimens with cross-sectional area of 1.0mm. For each experimental situation the sticks were randomly separated; 15 for the analysis to the SEM and 30 to be submitted to tensile strength. Mean bond strength values (MPa) were: E4 = 20.3 12; B4 = 24.2 11.3; B2 = 25.2 9.0; and E2 = 28.6 10.4. The statistical analysis of data showed that the values of bond strength at 200 rpm speed were significantly higher as compared to 400 rpm speed, regardless of saw employed. In SEM, it was noted better integrity of sticks at 200 rpm speed with presence of less extensive cracks in external edges. It was also found that the Extec saw at 400 rpm showed eccentric movement to cutting and achieved higher number of premature losses, a significant decreased mean total area of bond (p<0.05), in addition to significant difference in strength values compared with 200 rpm speed. It was concluded that using different speeds and their interaction with the used saw interfere with the integrity of specimens and the bond strength values, being more pronounced when using the Extec saw.
3

Avaliação da influência do tratamento térmico do silano sobre a resistência de união entre cimentos resinosos e uma cerâmica feldspática

Carvalho, Ronaldo Luís Almeida de 24 January 2013 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-03-22T17:35:14Z No. of bitstreams: 1 ronaldoluisalmeidadecarvalho.pdf: 1029602 bytes, checksum: cc60051c61c4c956fd0881bb40822c3c (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-04-24T02:26:37Z (GMT) No. of bitstreams: 1 ronaldoluisalmeidadecarvalho.pdf: 1029602 bytes, checksum: cc60051c61c4c956fd0881bb40822c3c (MD5) / Made available in DSpace on 2016-04-24T02:26:37Z (GMT). No. of bitstreams: 1 ronaldoluisalmeidadecarvalho.pdf: 1029602 bytes, checksum: cc60051c61c4c956fd0881bb40822c3c (MD5) Previous issue date: 2013-01-24 / O objetivo do presente estudo foi avaliar três hipóteses: H0- O tratamento térmico do silano e o tipo de cimento resinoso não influencia na resistência de união entre cimentos resinosos e uma cerâmica feldspática; H1- O tratamento térmico do silano influencia na resistência de união entre cimentos resinosos e uma cerâmica feldspática; H2- O cimento resinoso influencia na resistência de união de uma cerâmica feldspática. Foram confeccionados 30 blocos cerâmicos (VITA Mark II, Zahnfabrik), os quais foram duplicados em resina composta (W3D Master, Wilcos). Os blocos foram divididos em 6 grupos (n=5) de acordo com os seguintes tratamentos de superfície: ASCp- Ácido fluorídrico 10% + silano + Panavia F; ASTCp- Ácido fluorídrico 10% + silano + tratamento térmico (forno) + Panavia F; STCp- Silano + tratamento térmico (forno) + Panavia F; ASCr- Ácido fluorídrico 10% + silano + RelyX ARC; ASTCr- Ácido fluorídrico 10% + silano + tratamento térmico (forno) + RelyX ARC; STCr- Silano + tratamento térmico (forno) + RelyX ARC. Para realização do tratamento térmico do silano foi utilizado forno sob temperatura de 100 ºC durante 2 minutos. Cada bloco cerâmico já condicionado foi unido ao seu correspondente em resina composta, utilizando o cimento resinoso respectivo ao seu grupo, sob a carga constante de 750g. Cada conjunto cerâmica/cimento/resina composta foi seccionado e os corpos de prova foram analisados por meio do teste mecânico de microtração. Os valores de resistência de união e os desvios-padrão (MPa) para os grupos foram: ASCp (25,47 ± 9,34a); ASTCp (33,04 ± 10,65b); STCp (13,76 ± 8,82c); ASCr (24,80 ± 7,99a); ASTCr (23,84 ± 7,16a); STCr (11,41 ± 11,71c). Os testes ANOVA e Post Hoc foram aplicados. Com os resultados deste estudo, pode-se concluir: A hipótese H0 foi rejeitada; A hipótese H1 foi parcialmente aceita, pois o tratamento térmico do silano proporcionou maiores valores médios de resistência de união desde que seja realizado em associação com o condicionamento com ácido fluorídrico a 10%, independente do cimento resinoso testado; A hipótese H2 foi parcialmente aceita, pois o cimento com MDP apresentou valor médio de resistência de união estatisticamente superior ao cimento convencional, quando foi realizado o condicionamento com ácido fluorídrico a 10% previamente ao tratamento térmico do silano. / The aim of this study was to evaluate three hypotheses: H0- Heat treatment of silane and resin cement type does not influence the bond strength of resin cements and a feldspathic ceramic;H1- Heat treatment of silane influences the bond strength between cements resin and a feldspathic ceramic; H2- The resin cement influences the bond strength of a feldspathic ceramic. Thirty blocks were fabricated using a ceramic (VITA Mark II, Zahnfabrik), which were duplicated in composite resin (W3D Master, Wilcos). The blocks were divided into 6 groups (n = 5) in accordance with the following surface treatments: ASCp- Hydrofluoric acid 10% + silane + Panavia F; ASTCp- Hydrofluoric acid 10% + silane + heat treatment (furnace) + Panavia F; STCp- Silane + heat treatment (furnace) + Panavia F; ASCr- Hydrofluoric acid 10% + silane + RelyX ARC; ASTCr- Hydrofluoric acid 10% + silane + heat treatment (furnace) + RelyX ARC; STCr- Silane + heat treatment (furnace) + RelyX ARC. To perform the heat treatment silane was used furnace under temperature of 100 ° C for 2 minutes. Then each ceramic block conditioning was already attached to its corresponding composite resin, using a resin cement to its respective group, under the constant load of 750g. Each set ceramic / cement / composite resin was sectioned and the specimens were analyzed by microtensile mechanical test. The bond strength values and standard deviations (MPa) for the groups were: ASCp (25.47 ± 9.34a); ASTCp (33.04 ± 10.65b); STCp (13.76 ± 8.82c); ASCr (24.80 ± 7.99a); ASTCr (23.84 ± 7.16a); STCr (11.41 ± 11.71c). ANOVA and Post Hoc were applied. With the results of this study, we can conclude: The hypothesis H0 was rejected; H1 hypothesis was partially accepted because the heat treatment of the silane led to the highest average bond strength provided it is conducted in association with the hydrofluoric acid etching 10%, independent of the resin cement tested; H2 hypothesis was partially accepted because the cement with MDP averaged bond strength statistically superior to conventional cement when the conditioning was conducted with 10% hydrofluoric acid prior to the heat treatment of silane.
4

Efeito da temperatura de secagem de dois tipos de silano e da supressão ou redução do tempo de condicionamento com ácido hidrofluorídrico na resistência de união entre uma cerâmica de dissilicato de lítio e um cimento resinoso / Effect of drying temperature of two silan types and elimination or reduction of conditioning hydrofluoridric acid time with the bond strenght between a lithium disilicate ceramic and a resin cement

Leticia Monteiro Peixoto 24 August 2012 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Este estudo avaliou o efeito de diferentes métodos de silanização e aplicação do ácido hidrofluorídrico (HF) sobre a resistência à microtração de uma cerâmica de dissilicato de lítio a um cimento resinoso. Quarenta blocos de IPS e.max Press /Ivoclar Vivadent (5x5x6mm) foram cimentados a blocos de resina Z250/3M ESPE (5x5x6mm) usando o cimento resinoso RelyX ARC/3M ESPE de acordo com os seguintes métodos de tratamento superficial: G1: 20s de ácido fluorídrico (HF) + silano não hidrolisado Primer-Activactor/Dentsply (SNH) seco à temperatura ambiente; G2: 20s HF + silano pré-hidrolisado RelyX Ceramic-Primer/3M ESPE (SPH) seco à temperatura ambiente; G3: 10s HF + SNH seco com ar quente (50oC-2min); G4: 10sHF + SPH seco com ar quente (50oC-2min); G5: sem ácido, SNH seco com ar quente (50oC-2min); G6: sem ácido, SPH seco com ar quente (50oC-2min); G7: sem ácido, SNH seco à temperatura ambiente; G8: sem ácido, SPH seco à temperatura ambiente. Antes de cada método de silanização, os blocos cerâmicos receberam acabamento com lixas de carbeto de silício (220-600) e limpeza com ácido fosfórico 37% (1min). A cimentação foi realizada com carga vertical de 1kg por 10min. Os conjuntos de cerâmica/cimento/resina foram armazenados em água destilada (37C) por 24 horas e depois seccionados em máquina de corte Isomet 1000 a fim de obter palitos (n = 40) de 1mm2 de área da seção transversal, que foram submetidos ao teste de microtração em máquina de ensaio universal Emic (v = 0,5mm/min). O modo de fratura foi avaliado em microscópio eletrônico de varredura. A análise estatística foi realizada utilizando ANOVA / Dunnett (p-valor = 0,000). As médias MPa e desvio padrão foram: G1-21,5 (8,9) BC; G2-30,5 (7,2) A; G3-19.4 (9.1) BC; G4-24,0 (9,0) B; G5-8.1 (3.2) D; G6 -18,0 (6,2) C; G7-7.8 (2,6) D; G8-6.3 (2,5) D. Grupos 2, 3, 4 e 6 não tiveram falhas prematuras dos palitos contra os grupos 1, 5, 7 e 8, que apresentaram 2,2; 44,4; 75,6 e 33,3% de perdas prematuras, respectivamente. O teste de correlação foi realizado apresentando significância estatística, com valor de -0,736 (p-valor = 0,000), mostrando que, a medida que o percentual de perda prematura aumenta, a média da MPa diminui. Quanto ao modo de fratura, observou-se 44,97% de falhas do tipo mista, 51,70% de falhas do tipo adesiva, 3,33% de falhas do tipo coesiva do cimento. Quando é realizada a supressão do condicionamento com HF como pré-tratamento da superfície cerâmica IPS e.max Press, a aplicação de silano SPH, associada ao seu tratamento térmico, deve ser o método de silanização recomendado, embora os valores mais elevados de resistência de união tenham sido os obtidos quando utilizado o condicionamento com HF por 20s. Quando é realizada a redução do tempo de condicionamento com HF para 10s, a aplicação do silano (SPH ou SNH) deve ser sempre associada ao seu tratamento térmico. O SNH só deve ser usado se as superfícies das cerâmicas IPS e.max Press forem tratadas com HF. / This study devaluated the effect of different types of silanization and hydrofluoric acid on the microtensile bond strength of a lithium dissilicate ceramic system. Forty IPS e.max Press /Ivoclar Vivadent blocks (5x5x6mm) were cemented to Z250/3M ESPE resin blocks (5x5x6mm) using RelyX ARC/3M ESPE resin-cement according to the following silanization methods: G1: 20s hydrofluoric acid (HF) + non-hydrolyzed silane Primer-Activactor/Dentsply (NHS) dried at room temperature; G2: 20sHF + pre-hydrolyzed silane RelyX Ceramic-Primer/3M ESPE (PHS) dried at room temperature; G3: 10sHF + NHS dried with hot air (50oC-2min); G4: 10sHF + PHS + hot air; G5: NHS + hot air; G6: PHS + hot air; G7: NHS dried at room temperature; G8: PHS dried at room temperature. Before each silanization method, all ceramic blocks were abraded with SiC grit papers (220-600) and cleaned with 37% phosphoric acid (1min). The cementation was made with vertical load of 01 kg for 10 min. After cementation procedure, all ceramic/ciment/resin blocks were stored in distilled water (37oC) for 24h before being cut to obtain stick-shapped specimens (n=45) of approximately 1mm2 cross-sectional area for microtensile test (v=0.5mm/min). Statistical analysis was performed using ANOVA/Dunnett (p-value = 0,000). The mean MPa(SD) values were: G1-21.5(8.9)BC; G2-30.5(7.2)A; G3-19.4(9.1)BC; G4-24.0(9.0)B; G5-8.1(3.2)D; G6-18.0(6.2)C; G7-7.8(2.6)D; G8-6.3(2.5)D. Groups 2, 3, 4 and 6 had no sticks premature fail against groups 1, 5, 7 and 8, that had 2.2, 44.4, 75.6 and 33.3% of sticks premature fails, respectively. As the correlation coefficient was statistically significant, -0.736 (p-value = 0.000), it could be argued that as the percentage of premature loss increased the MPa mean decreases. The failure mode was 44.97% of mixed failures, 51.70% of adhesive failures, 3.33% of cohesive failures of the cement. When the pretreatment is performed without HF conditioning of the IPS e.max Press ceramic surface, then PHS with hot air application should be the silanization method recommended, although higher bond strength values were obtained when HF conditioning for 20s was used with this type of silane. When the time of HF conditioning is reduced for 10 sec, the application of silane (SPH or SNH) must be always related to its heat treatment. NHS should only be used if IPS e.max Press ceramic surfaces are treated with HF.
5

Efeito da temperatura de secagem de dois tipos de silano e da supressão ou redução do tempo de condicionamento com ácido hidrofluorídrico na resistência de união entre uma cerâmica de dissilicato de lítio e um cimento resinoso / Effect of drying temperature of two silan types and elimination or reduction of conditioning hydrofluoridric acid time with the bond strenght between a lithium disilicate ceramic and a resin cement

Leticia Monteiro Peixoto 24 August 2012 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Este estudo avaliou o efeito de diferentes métodos de silanização e aplicação do ácido hidrofluorídrico (HF) sobre a resistência à microtração de uma cerâmica de dissilicato de lítio a um cimento resinoso. Quarenta blocos de IPS e.max Press /Ivoclar Vivadent (5x5x6mm) foram cimentados a blocos de resina Z250/3M ESPE (5x5x6mm) usando o cimento resinoso RelyX ARC/3M ESPE de acordo com os seguintes métodos de tratamento superficial: G1: 20s de ácido fluorídrico (HF) + silano não hidrolisado Primer-Activactor/Dentsply (SNH) seco à temperatura ambiente; G2: 20s HF + silano pré-hidrolisado RelyX Ceramic-Primer/3M ESPE (SPH) seco à temperatura ambiente; G3: 10s HF + SNH seco com ar quente (50oC-2min); G4: 10sHF + SPH seco com ar quente (50oC-2min); G5: sem ácido, SNH seco com ar quente (50oC-2min); G6: sem ácido, SPH seco com ar quente (50oC-2min); G7: sem ácido, SNH seco à temperatura ambiente; G8: sem ácido, SPH seco à temperatura ambiente. Antes de cada método de silanização, os blocos cerâmicos receberam acabamento com lixas de carbeto de silício (220-600) e limpeza com ácido fosfórico 37% (1min). A cimentação foi realizada com carga vertical de 1kg por 10min. Os conjuntos de cerâmica/cimento/resina foram armazenados em água destilada (37C) por 24 horas e depois seccionados em máquina de corte Isomet 1000 a fim de obter palitos (n = 40) de 1mm2 de área da seção transversal, que foram submetidos ao teste de microtração em máquina de ensaio universal Emic (v = 0,5mm/min). O modo de fratura foi avaliado em microscópio eletrônico de varredura. A análise estatística foi realizada utilizando ANOVA / Dunnett (p-valor = 0,000). As médias MPa e desvio padrão foram: G1-21,5 (8,9) BC; G2-30,5 (7,2) A; G3-19.4 (9.1) BC; G4-24,0 (9,0) B; G5-8.1 (3.2) D; G6 -18,0 (6,2) C; G7-7.8 (2,6) D; G8-6.3 (2,5) D. Grupos 2, 3, 4 e 6 não tiveram falhas prematuras dos palitos contra os grupos 1, 5, 7 e 8, que apresentaram 2,2; 44,4; 75,6 e 33,3% de perdas prematuras, respectivamente. O teste de correlação foi realizado apresentando significância estatística, com valor de -0,736 (p-valor = 0,000), mostrando que, a medida que o percentual de perda prematura aumenta, a média da MPa diminui. Quanto ao modo de fratura, observou-se 44,97% de falhas do tipo mista, 51,70% de falhas do tipo adesiva, 3,33% de falhas do tipo coesiva do cimento. Quando é realizada a supressão do condicionamento com HF como pré-tratamento da superfície cerâmica IPS e.max Press, a aplicação de silano SPH, associada ao seu tratamento térmico, deve ser o método de silanização recomendado, embora os valores mais elevados de resistência de união tenham sido os obtidos quando utilizado o condicionamento com HF por 20s. Quando é realizada a redução do tempo de condicionamento com HF para 10s, a aplicação do silano (SPH ou SNH) deve ser sempre associada ao seu tratamento térmico. O SNH só deve ser usado se as superfícies das cerâmicas IPS e.max Press forem tratadas com HF. / This study devaluated the effect of different types of silanization and hydrofluoric acid on the microtensile bond strength of a lithium dissilicate ceramic system. Forty IPS e.max Press /Ivoclar Vivadent blocks (5x5x6mm) were cemented to Z250/3M ESPE resin blocks (5x5x6mm) using RelyX ARC/3M ESPE resin-cement according to the following silanization methods: G1: 20s hydrofluoric acid (HF) + non-hydrolyzed silane Primer-Activactor/Dentsply (NHS) dried at room temperature; G2: 20sHF + pre-hydrolyzed silane RelyX Ceramic-Primer/3M ESPE (PHS) dried at room temperature; G3: 10sHF + NHS dried with hot air (50oC-2min); G4: 10sHF + PHS + hot air; G5: NHS + hot air; G6: PHS + hot air; G7: NHS dried at room temperature; G8: PHS dried at room temperature. Before each silanization method, all ceramic blocks were abraded with SiC grit papers (220-600) and cleaned with 37% phosphoric acid (1min). The cementation was made with vertical load of 01 kg for 10 min. After cementation procedure, all ceramic/ciment/resin blocks were stored in distilled water (37oC) for 24h before being cut to obtain stick-shapped specimens (n=45) of approximately 1mm2 cross-sectional area for microtensile test (v=0.5mm/min). Statistical analysis was performed using ANOVA/Dunnett (p-value = 0,000). The mean MPa(SD) values were: G1-21.5(8.9)BC; G2-30.5(7.2)A; G3-19.4(9.1)BC; G4-24.0(9.0)B; G5-8.1(3.2)D; G6-18.0(6.2)C; G7-7.8(2.6)D; G8-6.3(2.5)D. Groups 2, 3, 4 and 6 had no sticks premature fail against groups 1, 5, 7 and 8, that had 2.2, 44.4, 75.6 and 33.3% of sticks premature fails, respectively. As the correlation coefficient was statistically significant, -0.736 (p-value = 0.000), it could be argued that as the percentage of premature loss increased the MPa mean decreases. The failure mode was 44.97% of mixed failures, 51.70% of adhesive failures, 3.33% of cohesive failures of the cement. When the pretreatment is performed without HF conditioning of the IPS e.max Press ceramic surface, then PHS with hot air application should be the silanization method recommended, although higher bond strength values were obtained when HF conditioning for 20s was used with this type of silane. When the time of HF conditioning is reduced for 10 sec, the application of silane (SPH or SNH) must be always related to its heat treatment. NHS should only be used if IPS e.max Press ceramic surfaces are treated with HF.

Page generated in 0.0997 seconds