• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 56
  • 20
  • Tagged with
  • 76
  • 76
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Contribution au développement de recouvrements à base de simili-téflon et de polysccharide pour les stents

Fakhari Tehrani, Soudeh 09 1900 (has links) (PDF)
Les maladies cardiovasculaires sont une des principales causes de décès dans le monde. L'athérosclérose est une maladie évolutive cardiovasculaire par laquelle les artères s'obstruent partiellement ou totalement. L'angioplastie est une technique cliniquement validée pour traiter l’athérosclérose bien que, le taux de resténose élevé soit un facteur limitant. L’implantation d’endoprothèses coronariennes (stents) lors de l’angioplastie a permis une diminution de 15 à 30% du taux de resténose, mais le risque reste encore relativement élevé. De plus, la corrosion des stents métalliques et la libération d’éléments potentiellement toxiques sont d’autres problèmes liés à leur application dans l’organisme. L’utilisation d’une couche polymérique à la surface des stents métalliques présente une voie intéressante pour prévenir le stent de la corrosion et diminuer le taux de resténose. Dans le cadre de ce mémoire, deux différents types de revêtements polymériques seront présentés. Tout d’abord, cette étude a porté sur les couches minces fluorocarbonées (CFx) déposées par plasma froid sur la surface en acier inoxydable. Ce recouvrement pourrait être chimiquement inerte, hydrophobe et biocompatible. Grâce à la méthode de dépôt par plasma froid associée à la modulation de la composition chimique et de la morphologie de l’interface, cette couche mince fluorocarbonée présente une bonne adhérence interfaciale (polymère-métal). Cependant des études de vieillissement effectuées sur ces échantillons ont montré une dégradation chimique et morphologique du revêtement et une oxydation du substrat après seulement 2 semaines de vieillissement dans l’eau déionisée. Afin de pallier ce problème, l’effet du post-traitement a été étudié. Dans, le chapitre II l’influence de ces traitements sur la composition chimique, la structure morphologie et la résistance au vieillissement sera présentée. La deuxième partie de ces travaux porte sur l’étude des recouvrements en copolymère dextrane-graft-polybutylméthacrylate (dextane-graft-PBMA). Le dextrane est un polysaccharide avec des propriétés biologiques intéressantes. Les dérivés du dextrane stimulent la prolifération des cellules endothéliales et inhibent celle des cellules musculaires lisses ainsi que la coagulation sanguine. L’utilisation des dérivés du dextrane en tant que recouvrement des stents métalliques permettrait de diminuer le taux de resténose et d’améliorer leur hémocompatibilité à long terme. Le dextrane a une très grande solubilité en milieu aqueux et ne peut donc pas former directement des films stables. De plus, il présente de très faibles propriétés mécaniques. La copolymérisation du dextrane avec un polymère synthétique hydrophobe est une voie intéressante afin de former un recouvrement plus stable en milieu aqueux et conférer des propriétés mécaniques plus importantes. Dans cette optique, la synthèse du copolymère dextrane-graft-PBMA peut s’avérer intéressante. Cette approche permettrait de combiner les propriétés biologiques du dextrane et les propriétés mécaniques du poly (butylméthacrylate). Le projet est partagé entre le Laboratoire de Bio-ingénierie de Polymères Cardiovasculaires (LBPC) à l’université Paris 13 et le Laboratoire de Biomatériaux et de Bioingénierie (LBB) à Québec. Des échantillons modèles d’acier inoxydable 316L ont été préparés au LBB, recouverts au LBPC et caractérisés au LBB au niveau de la composition chimique, de la structure morphologique et des propriétés mécaniques des recouvrements de dextrane-graft-PBMA. / Cardiovascular diseases are a major cause of death in the world. Atherosclerosis is a progressive disease in which the arteries partially or completely clog. Angioplasty is a clinically validated technique for treatment of atherosclerosis; however, a high restenosis rate remains the limiting factor for angioplasty. The implantation of a stent during angioplasty reduces the rate of restenosis between 15-30%, but the risk of restenosis remains relatively high. Moreover, corrosion and the release of potentially toxic elements are further drawbacks associated with metallic stents. The use of a polymer coating on the metallic stent surfaces can prevent stent corrosion and reduce the restenosis rate. In this study two different types of polymeric stent coatings will be presented. The first part of this research deals with the thin fluorocarbon (CFx) polymeric film deposited by cold plasma on the surface of stainless steel. This coating is assumed to be chemically inert, hydrophobic, and bio-compatible. Use of cold plasma deposition method modulates chemical composition and changes the morphology of the interface in the way that the polymeric film shows a good interfacial adhesion (polymer-metal). However, the aging studies performed on the samples submerged in deionised water show evidence of morphological and chemical degradation of the coating besides demonstrating the substrate oxidation, after only two weeks. To overcome this problem, the influence of a post-treatment was studied. In chapter II, The influence of these treatments on the chemical composition, morphological structure and resistance to aging will be presented. The second part of this research involves the study of dextran-graf-polybutylmethacrylate (dextran-graft-PBMA); dextran is a polysaccharide with interesting biological properties. The dextran derivatives stimulate the proliferation of endothelial cells and inhibit the smooth muscle cells proliferation and blood clotting. It was assumed that the dextran derivative coatings may decrease the rate of restenosis and improve long-term hemocompatibility of the stents. Unfortunately, dextran is highly soluble in aqueous media, therefore cannot directly form a stable film. Furthermore, dextran has poor mechanical properties. A solution to form a more stable coating in aqueous media, while improving its mechanical properties, is the copolymerization of dextran with a synthetic hydrophobic polymer. In this context, the synthesis of copolymer dextran-graf-polybutylmethacrylate seemed to offer a promising alternative. The synthesis of copolymer dextran-graf-polybutylmethacrylate that combines the biological properties of dextran and mechanical properties of poly(butylmethacrylate), might be a potential solution. The project is shared between Laboratoire de Bio-ingénierie de Polymères Cardiovasculaires (LBPC) at Paris 13 University and Laboratoire de Biomatériaux et de Bioingénierie (LBB) in Quebec City. Model samples of 316L stainless steel are prepared at LBB and covered in LBPC and characterized at LBB for the analysis of chemical composition, morphological structure, and mechanical properties of dextan-graft-PBMA coatings.
72

Étude expérimentale d'optimisation de procédés de modifications de surface de l'acier inoxydable 316 pour application aux dispositifs endovasculaires

Haïdopoulos, Marie 02 1900 (has links) (PDF)
L’objectif de la présente thèse a été de développer des procédés de modifications de surface de l’acier inoxydable 316, pour en améliorer les performances à long terme en milieu biologique, en vue d’une application pour les stents coronariens. Deux types de modifications de surface successifs ont été menés sur l’acier; des pré traitements et des recouvrements. Les premiers ont eu pour but de modifier la composition chimique, la rugosité et la topographie des surfaces métalliques, afin de les préparer au dépôt des seconds, lesquels auront pour fonction d’isoler totalement le métal du milieu biologique. Les pré traitements de polissage mécanique et électrochimique, de dégraissage par ultrasons, d’immersion en solutions alcalines et acides et de décapage par plasma froid, ont été testés. Les modifications de surfaces induites ont été caractérisées par Spectroscopie de Photoélectrons induits par Rayons X (XPS), par Microscopie à Force Atomique (MFA) et par Microscopie Électronique à Balayage (MEB). La combinaison optimisée des traitements par ultrasons, polissage électrochimique, attaque acide et décapage par plasma froid a abouti à l’obtention de surfaces lisses, homogènes, sans défauts, décontaminées et quasi exemptes d’oxyde métallique considéré fragile mécaniquement. Le pré traitement d’électropolissage a fait tout particulièrement l’objet d’une étude approfondie. Les recouvrements amorphes, fluorocarbonés et partiellement hydrogénés, fortement hydrophobes, lisses et sans défauts ont été déposés sur de substrats métalliques pré traités en optimisant les paramètres de fonctionnement du réacteur à plasma froid radio fréquence. Des dépositions ont également été effectuées sur des substrats non pré traités dans les conditions optimales de polymérisation. Elles ont alors conduit à la formation de films poreux, composés de sphères nanométriques distribuées de manière hétérogène, de structure également amorphe et partiellement hydrogénée. L’importance de l’étape des pré traitements a ainsi été démontrée, celle ci influençant principalement la morphologie des recouvrements. Finalement, l’imperméabilité des recouvrements obtenus sur des substrats pré traités ont été validées dans des conditions pseudo physiologiques similaires à celles présentes dans les artères coronariennes. / The aim of this study was to develop various surface modification procedures for 316 stainless steel to improve its long term performances as endovascular stents. The strategy behind this work was divided into two parts: surface pre treatments and surface coatings. Chemical composition, roughness and topography of the metallic surfaces were modified by the surface pre treatments in order to prepare the substrates for the post deposited coatings that would form an impermeable barrier completely isolating the metallic device from body fluids. Surface pre treatments of the metallic surfaces consist of mechanical and electrochemical polishing, ultrasonic cleaning, dipping in alkaline and acidic solutions, and plasma etching. The aim was to obtain a smooth and homogeneous surface of the substrate as well as to remove any fragile interlayer, particularly the metallic oxide and the contamination layers. Characterization of the modified surfaces was performed by X ray Photoelectron Spectroscopy (XPS), Atomic Force Microscopy (AFM) and Scanning Electron Microscopy (SEM). Optimized surface properties were obtained by combining ultrasonic cleaning, electrochemical polishing, acid dipping and plasma etching. Of the above mentioned methods, emphasis was placed on the electrochemical polishing procedure. Ultra thin fluorocarbon films were deposited on pre treated stainless steel surfaces by radio frequency glow discharge plasma, after modulating plasma deposition parameters in order to promote the polymerization process. Films were then partially hydrogenated, amorphous, highly hydrophobic, smooth and pinhole free. Depositions under optimal polymerization conditions were also performed on as received substrates and lead to the formation of partially hydrogenated, porous fluorocarbon coatings that consisted of heterogeneously distributed nanospherical particles. Thus, pre treatments prior to deposition were essential, demonstrated by their strong influence on the morphology of the plasma polymer films. Finally, plasma polymer films were validated with respect to impermeability in a medium reproducing the physiological conditions in the coronary arteries.
73

Caractérisation du comportement en fatigue de pièces à usinage amélioré fabriquées par métallurgie des poudres

Campbell-Tremblay, Julie 03 1900 (has links) (PDF)
No description available.
74

Performance of lead anodes used for zinc electrowinning and their effects on energy consumption and cathode impurities

Zhang, Wei 05 1900 (has links) (PDF)
No description available.
75

Modification de la microstructure et des propriétés mécaniques d'échafaudages à base de gels de collagène pour la régénération du tissu vasculaire

Achilli, Matteo 01 1900 (has links) (PDF)
Le besoin de substituts pour vaisseaux sanguins de petit calibre a attiré une attention considérable sur le développement de constructions artérielles dans des bioréacteurs à partir de systèmes d’échafaudage. Les gels formés à partir de collagène reconstitué représentent des substrats idéaux pour le remodelage du à l’activité cellulaire, mais leur faible résistance et élasticité limitent leur utilisation comme échafaudages pour la régénération du tissu vasculaire. Ces caractéristiques proviennent de la perte d’organisation structurelle liée au processus d’extraction du collagène. Dans ce contexte, l’objectif de ce projet était d’améliorer les propriétés mécaniques des gels de collagène afin de supporter la croissance et la maturation du tissu vasculaire sous contrainte cyclique. En considérant l’importance de l’état d’agrégation du collagène pour les propriétés mécaniques des tissus natifs, la stratégie de ce projet a été de modifier la microstructure des matrices de collagène reconstitué en agissant sur trois aspects : 1) les interactions intermoléculaires et la fibrillogenèse ont été ajustées en variant les paramètres expérimentaux (pH, température, force ionique et concentration du collagène); 2) des liaisons covalentes ont été introduites afin de fixer des fibrilles voisines; 3) les gels ont été compactés et les fibrilles alignées grâce à l’action de remodelage des cellules. Des mesures de spectrophotométrie et des images par MEB ont confirmé les effets des conditions expérimentales et du remodelage sur la microstructure des gels. Notamment, la présence des cellules a permis la formation de matrices plus compactes et orientées, surtout en présence de contraintes mécaniques. Des essais mécaniques ont démontré que les stratégies adoptées ont engendré le renforcement de la structure. En particulier, des essais cycliques ont établi que la variation des conditions expérimentales combinée à la réticulation ont produit des matrices dont l’hystérèse diminue et l’élasticité augmente. En conclusion, l’ensemble de ces études a permis la réalisation à court terme (24-48 h) de structures à base de collagène présentant une résistance mécanique, une rigidité et une élasticité accrues. Ces résultats suggèrent que ces matrices sont de bons candidats comme supports pour la régénération de tissus vasculaires sous conditionnement cyclique. / The need for small-caliber vascular replacements has attracted considerable attention on the development of scaffold-based vascular constructs in bioreactors. Reconstituted collagen gels represent ideal substrates for cell-mediated remodeling, but their low strength and low elasticity, limits their application as scaffold for the regeneration of the vascular tissue. These features result from collagen extraction and the consequent loss of structural organization. The objective of this project was to improve the mechanical performances of collagen gels in order to support the growth and the maturation of the vascular tissue under cyclic conditioning. Considering how fundamental collagen assembly is for the mechanical behavior of native tissues, the microstructure of reconstituted collagen lattices was modified by working on three aspects: 1) The intermolecular interactions and the aggregation of collagen monomers were tailored by modulating the experimental conditions, including pH, temperature, ionic strength and collagen concentration; 2) Inter-fibril crosslinking was carried out in order to fix neighboring collagen fibrils through their reactive side chains; 3) Gels were compacted and fibrils were aligned through cell-mediated remodeling. Spectrophotometric analyses and SEM confirmed the effects of changes in experimental conditions and cell-mediated remodeling on collagen gels microstructure. Notably, the presence of SMCs lead to tighter and highly oriented lattices, moreover in the presence of mechanical constraints. Mechanical tests showed that the adopted procedures contributed to the stiffening of collagen lattices. In particular, the modulation of the experimental conditions combined with crosslinking lead to lattices presenting lower hysteresis and higher elasticity as shown by cyclic tests. In conclusion, this study produced, in a short time (24-48 h), collagen gel-based lattices with improved stiffness, strength, and elastic recoil. The results suggest that these lattices are serious candidates for the role of temporary supports during the maturation period under cyclic loading.
76

Nouvelle approche pour la mesure de la solubilité de l'hydrogène dans l'aluminium liquide

Bouchard, Marc-Olivier 01 1900 (has links) (PDF)
La présence d’hydrogène en solution dans l’aluminium liquide entraîne la formation de porosités une fois celui-ci solidifié. C’est pourquoi il est important de bien mesurer la quantité de gaz dissous dans le métal. La méthode de Sieverts, utilisée par d’autres expérimentateurs dans le passé, montre certaines faiblesses et une nouvelle méthode plus fiable et versatile est proposée afin de valider les résultats obtenus précédemment. Après plusieurs tests et améliorations au montage et à la méthodologie, des résultats prometteurs ont été obtenus. En fait, un phénomène attribuable à la dissolution de l’hydrogène dans l’aluminium a été observé. En faisant quelques hypothèses, ces résultats ont permis de valider le modèle mathématique en obtenant une valeur de la solubilité de l’hydrogène dans l’aluminium près de celle des autres expérimentateurs. Suite à ces essais, de nouvelles améliorations ont été apportées au montage et une nouvelle méthodologie de mesure est proposée pour les expérimentations futures. / The presence of hydrogen in solution in liquid aluminium leads to the formation of porosities after the solidification. For this reason, a good measurement of the quantity of gas dissolve in the molten metal should be made. The Sieverts’ method, used by the precedents experimenters, shows some weaknesses and a new method more reliable and versatile is proposed to validate the results formerly obtained. After several tests and ameliorations to the measurement system, some promising results were obtained. A phenomenon that can be attributed to the dissolution of hydrogen in liquid aluminium was observed. By making some assumptions, these results were used to validate the mathematical model by obtaining a value of the solubility of hydrogen in aluminum near the other experimenters. Following that, new ameliorations were made to the system and that a new measurement methodology is proposed for the future experimentations.

Page generated in 0.0767 seconds