Spelling suggestions: "subject:"minifaisceaux"" "subject:"microfaisceau""
1 |
Etablissement de références dosimétriques dans les faisceaux de rayons X de hautes énergies et de très petites sections (< 1cm²) pour la radiothérapie / Establishment of dosimetric references for high energy X-ray beams of very small field sizes (< 1 cm²) used in radiotherapyDufreneix, Stéphane 17 December 2014 (has links)
En tant que laboratoire national pour la métrologie des rayonnements ionisants, le Laboratoire National Henri Becquerel met au point les méthodes de mesures absolues pour établir les références dosimétriques. Il dispose, entre autres, de références dans des faisceaux de rayons X utilisés en radiothérapie et ayant une taille de champ comprise entre 10 et 2 cm de côté. Afin de s’approcher des plus petits champs utilisés en clinique, la miniaturisation des détecteurs absolus n’étant pas possible, il est proposé dans cette thèse de remplacer la dose absorbée en un point par le produit dose surface (PDS). L’applicabilité du PDS mesuré à l’aide de dosimètres dont la surface sensible est plus grande que celle du champ de rayonnement a été vérifiée. Ainsi, un calorimètre graphite avec une surface sensible de 3 cm de diamètre a été conçu, construit et testé. En vue du transfert des références dosimétriques à l’utilisateur, une chambre d’ionisation de même diamètre a elle aussi été réalisée et testée. Son coefficient d’étalonnage en termes de PDS a été déterminé dans des faisceaux circulaires de 2, 1 et 0.75 cm de diamètre avec une incertitude type inférieure à 0.7 %. La distribution relative de la dose absorbée dans l’eau en deux dimensions a été mesurée au moyen d’un dosimètre diamant, d’une chambre d’ionisation PinPoint et de films gafchromiques, pour lesquels un protocole de lecture spécifique a été mis au point. Les résultats dans le faisceau de 2 cm de diamètre ont montré un bon accord entre les approches en termes de PDS et de dose absorbée dans l’eau en un point, après application des facteurs de correction obtenus au moyen de simulations Monte Carlo et des mesures de distribution de dose. Les coefficients d’étalonnage de la chambre d’ionisation de grandes dimensions établis dans les champs de 1 et 0.75 cm de diamètre sont compatibles aux incertitudes près mais s’écartent de -2.6 % de celui établi dans le champ de 2 cm de diamètre. L’utilisation du PDS nécessite donc une surface de détection notablement plus grande que la section du mini-Faisceau. / The French primary standard dosimetry laboratory “Laboratoire National Henri Becquerel” is in charge of the establishment of dosimetric standards for ionizing radiation beams. Absolute dose measurements are thus available for X-Ray beams used in radiotherapy for field sizes between 10 and 2 cm. Since the miniaturization of absolute dosimeters is not possible for smaller field sizes, a dose area product (DAP) has been suggested as a substitute to the absorbed dose at a point.In order to measure a DAP with dosimeters which sensitive surface is larger than the beam, a graphite calorimeter with a sensitive surface of 3 cm diameter was designed, built and tested. An ionization chamber with the same diameter was realized and tested to transfer the dosimetric references to the end users. Its calibration factor in terms of DAP was determined in circular beams of 2, 1 and 0.75 cm diameter with an uncertainty smaller than 0.7 %. The two-Dimension relative dose distribution was measured thanks to a diamond dosimeter, a PinPoint ionization chamber and gafchromic films, using a specific protocol.Both approaches, respectively based on a PDS and an absorbed dose to water at a point, were in good agreement in the 2 cm beam. Correction factors determined from Monte Carlo simulations and measured dose distributions were needed for this comparison. The calibration factor of the large ionization chamber in the 1 and 0.75 cm diameter beams were in good agreement within the uncertainties but a gap of -2.6 % was found with the one established in the 2 cm diameter beam. As a result, the DAP can be used if the sensitive surface is much larger than the beam section.
|
2 |
Dosimétrie des faisceaux de photons de petites dimensions utilisés en radiothérapie stéréotaxique : détermination des données dosimétriques de base et évaluation des systèmes de planification de traitement / Dosimetry of small beams used in stereotactic radiotherapy : dosimetric data determination and treatment planning systems evaluationMoignier, Cyril 10 October 2014 (has links)
Les faisceaux de photons de petites dimensions utilisés en radiothérapie stéréotaxique sont caractérisés par de forts gradients de dose et un manque important d’équilibre électronique latéral, ce qui rend les techniques dosimétriques conventionnelles inadaptées. L’objectif de la thèse est de permettre une meilleure évaluation de la dose délivrée aux patients traités par radiothérapie stéréotaxique. D’une part, les données dosimétriques de base utilisées pour l’étalonnage du système de planification de traitement (TPS) ont été déterminées numériquement. Pour cela, deux installations de radiothérapie de type CyberKnife ont été modélisées avec le code Monte Carlo PENELOPE. Des mesures de rapport d’ouverture du collimateur ont également été réalisées à l’aide de plusieurs détecteurs actifs et de deux dosimètres passifs (film radiochromique et micro-LiF) et comparées aux facteurs d’ouverture du collimateur calculés par simulation. Six détecteurs ont été modélisés afin d’étudier les phénomènes physiques impliqués dans la réponse des détecteurs en petits champs. Parmi les détecteurs étudiés, seuls les films radiochromiques sont en accord avec la simulation, ils peuvent être utilisés sans facteur correctif. La perturbation induite par les autres détecteurs a pu être expliquée, soit par l’effet volume dû à la taille trop importante du volume actif par rapport au diamètre du faisceau, soit par la masse volumique des matériaux utilisés dans la conception du détecteur qui est trop éloignée de celle de l’eau. Les facteurs correctifs, permettant de corriger la non-équivalence-eau et/ou la mauvaise résolution spatiale de chaque détecteur, ont été déterminés pour les deux systèmes CyberKnife.D’autre part, un protocole de mesure de distributions de dose 2D pour les mini-faisceaux, basé sur l’utilisation des films radiochromiques, a été établi et un programme sous MatLab permettant l’analyse entre les distributions de doses mesurées et calculées a été développé. Des plans de traitement stéréotaxique en milieu hétérogène ont ensuite été réalisés pour un fantôme afin d’évaluer les algorithmes de calcul de dose implémentés dans le TPS MultiPlan (TPS associé au système CyberKnife). L’analyse des distributions de dose 2D des plans de traitement a montré que l’algorithme de type « Pencil Beam » implémenté dans MultiPlan est performant en milieu homogène équivalent-eau mais n’est pas adapté pour les milieux à faible densité électronique tels que le poumon. En effet, celui-ci surestime la dose dans le champ (jusqu’à 40%) ce qui peut conduire à diminuer l’efficacité du traitement de la tumeur et la sous-estime hors du champ ce qui risque de sous-évaluer la dose reçue par les organes à risques à proximité. En milieu hétérogène, l’algorithme Monte Carlo implémenté dans MultiPlan est globalement en accord avec la mesure et est par conséquent l’algorithme à privilégier pour estimer la dose délivrée au patient lorsque des milieux à faible densité sont présents. / Dosimetry of small beams is challenging given their small size compared to the detectors, high dose gradient and the lack of lateral electronic equilibrium. The Ph.D. thesis aims to improve the accuracy of the dose delivered to the patient in stereotactic radiotherapy.On the one hand, dosimetric data used to calibrate the treatment planning system (TPS) were determined using numerical simulations. To achieve this, two CyberKnife radiotherapy facilities were modelled using the PENELOPE Monte Carlo code. Output ratios measurements were performed with several active detectors and with two passive dosimeters (radiochromic film and micro-LiF) and compared with output factors calculated by simulation. Six detectors were modeled in order to study the detectors response in small beams. Among the detectors studied, only the radiochromic films were in agreement with the simulations, they can be used without correction factors. The disturbance of the detectors response in small beams was explained either by the volume effect induced by the active volume, which is too high compared to the beam size, or by the mass density effect induced by the detector body materials which are too far from water mass density. The correction factors, required to correct the disturbance caused by the non-water-equivalence and/or the low spatial resolution of each detector, were calculated for the two CyberKnife systems.On the other hand, a 2D dose measurement protocol using radiographic films and a MatLab program were developed. Stereotactic treatment plans were then performed for a phantom in order to assess the calculation algorithms implemented in the MultiPlan TPS (associated with the CyberKnife system). The analysis of the 2D dose distributions related to the stereotactic treatment plans has shown that the “Pencil Beam” based algorithm implemented in MultiPlan is suitable for dose calculation in homogeneous water-equivalent media but not in low electronic density media such as the lung. Indeed, the dose is overestimated (up to 40%) inside the field and may lead to reduce the tumor treatment efficiency while it is underestimated outside the field which can underestimate the dose to critical organs within proximity of the tumor. Regarding the Monte Carlo algorithm implemented in MultiPlan, calculated and measured dose distributions are consistent and, as a consequence, it is the most suitable algorithm available in MultiPlan to estimate the dose received by a patient when low density media are involved.
|
3 |
Simulation d’un accélérateur linéaire d’électrons à l’aide du code Monte-Carlo PENELOPE : métrologie des traitements stéréotaxiques par cônes et évaluation de l’algorithme eMC / Simulation of a linear accelerator with PENELOPE Monte Carlo code : stereotactic treatments metrology by cones and eMC algorithm assessmentGarnier, Nicolas 19 December 2018 (has links)
L’accélérateur linéaire d’électrons du Centre Hospitalier Princesse Grace a été simulé à l’aide du code Monte-Carlo PenEasy. Après avoir validé l’ensemble des techniques permettant d’accélérer le temps de calcul (réduction de variance, parallélisation, …), les caractéristiques des faisceaux initiaux d’électrons ont été déterminées pour une énergie photons et quatre énergies électrons afin d’étudier deux problématiques cliniques. La première concerne l’étude comparative des réponses de huit dosimètres pour la mesure des données de base en mini-faisceaux à l’aide de cônes stéréotaxiques de diamètres compris entre 30 mm et 4 mm. Ces faisceaux de photons sont caractérisés par de forts gradients de dose et un manque important d’équilibre électronique latéral, ce qui rend les techniques dosimétriques conventionnelles inadaptées. Des mesures de facteurs d’ouverture collimateur (FOC), de profil de dose et de rendement en profondeur ont été réalisées avec sept détecteurs actifs (diodes, chambres d’ionisations et MicroDiamond) et un détecteur passif (film radiochromique) et comparées avec les résultats issus de la simulation Monte-Carlo considérée comme notre référence. Pour la mesure du FOC, seul le film radiochromique est en accord avec la simulation avec des écarts inférieurs à 1 %. La MicroDiamond semble être le meilleur détecteur actif avec un écart maximal de 3,7 % pour le cône de 5 mm. Concernant les mesures de profils de dose, les meilleurs résultats ont été obtenus avec le film radiochromique et les diodes blindées ou non (écart de pénombre inférieur à 0,2 mm). Pour les rendements en profondeur, l’ensemble des détecteurs utilisés sont satisfaisants (écart de dose absorbée inférieur à 1 %). La deuxième application concerne l’évaluation de l’algorithme de dépôt de dose électron eMC sur des coupes scanographiques. Pour cela, un programme de « voxélisation » sous MATLAB a été développé afin de transformer les nombres Hounsfield issus du scanner en propriété de matériau (densité et composition chimique) utilisable par le code Monte-Carlo PenEasy. Une triple comparaison entre la mesure avec films radiochromiques, le calcul avec l’algorithme eMC et la simulation Monte-Carlo PenEasy a été réalisée dans différentes configurations : des fantômes hétérogènes simples (superposition de plaques de différentes densités), un fantôme hétérogène complexe (fantôme anthropomorphique) et une comparaison sur patient. Les résultats ont montré qu’une mauvaise affectation d’un matériau du milieu provoque un écart de dose absorbée localement (jusqu’à 16 %) mais aussi en aval de la simulation du fait d’une mauvaise prise en compte de la modification du spectre électronique. La comparaison des distributions de dose absorbée sur le plan patient a montré un très bon accord entre les résultats issus de l’algorithme eMC et ceux obtenus avec le code PenEasy (écart < 3 %). / Using the PenEasy Monte-Carlo code was simulated the linear electron accelerator of Princess Grace Hospital Center. After the validation of all the techniques allowing to accelerate the calculation time (variance reduction technique, parallelization, etc.), the characteristics of the initial electron beams were determined for one photon energy and four electron energies in order to study two clinical issues. The first one concerns the comparative study of the responses of eight dosimeters for the measurement of basic data in small fields using stereotactic cones with a diameter between 30 mm to 4 mm. These photon beams are characterized by strong dose gradients and a significant lack of charged particule equilibrium, making conventional dosimetric techniques unsuitable. Output factor measurment (OF), dose profile and depth dose measurements were performed with seven active detectors (diodes, ionization chambers and MicroDiamond) and a passive detector (radiochromic film) and compared with the results from the Monte Carlo simulation considered as our reference. For the OF measurement, only the radiochromic film is in agreement with the simulation with difference less than 1%. The MicroDiamond seems to be the best active detector with a maximum gap of 3.7% for the 5 mm cone. Concerning the dose profile measurements, the best results were obtained with the radiochromic film and diodes shielded or not (penumbre difference of less than 0,2 mm). For depth dose, all the detectors used have good result (absorbed dose difference less than 1 %). The second application concerns the evaluation of the eMC electron deposition algorithm on CT slices. For this, a « voxelisation » program under MATLAB was developed to transform the Hounsfield numbers from the scanner to material property (density and chemical composition) usable by the PenEasy Monte-Carlo code. A triple comparison between measurement with radiochromic films, calculation with the eMC algorithm and Monte-Carlo PenEasy simulation was carried out in different configurations: simple heterogeneous phantom (superposition of plates of different densities), a complex heterogeneous phantom (anthropomorphic phantom) and a patient comparison. The results showed that a wrong material assignment of the medium causes a difference of dose absorbed locally (up to 16%) but also downstream the simulation due to a wrong taking into account of the modification of the electronic spectrum. The absorbed dose distribution comparison on the patient plane showed a very good agreement between the results from the eMC algorithm and those obtained with the PenEasy code (deviation < 3%).
|
Page generated in 0.0471 seconds