• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 9
  • 9
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Film formation on copper in moist air-sulfur dioxide

Chawla, Sandeep Kumar January 1990 (has links)
No description available.
2

Interaktivní grafický software pro výpočty stavů vlhkého vzduchu / The interactive graphical software for calculation of moist air states

Snášel, Pavel January 2010 (has links)
The aim of this thesis is to create an interactive graphical software intended for calculations of states of moist air and marking these states in Molliere’s i-x diagram. The branch of air-conditioning is considered to be the main field of application of this software, so the calculations of basic changes of moist air have been included to this software as well.
3

Systemsimulation eines elektrischen Turboladers für Brennstoffzellenanwendungen unter Berücksichtigung von Kondensationsphänomenen in der Radialturbine

Lück, Sebastian, Wittmann, Tim, Göing, Jan, Bode, Christoph, Friedrichs, Jens 27 May 2022 (has links)
Das Betriebsverhalten eines elektrischen Turboladers zur Bedruckung des Kathodengassystems eines automobilen Brennstoffzellensystems wird unter Berücksichtigung der feuchten Brennstoffzellenabluft untersucht. Basierend auf den Komponentenkennfeldern von Elektromotor, Leistungselektronik, Lagerung und Turbomaschinenkomponenten werden stationäre und transiente Betriebslinien berechnet, anhand derer eine Betriebspunktverschiebung gezeigt wird. Diese kann auf die Einflüsse der Gaszusammensetzung und Kondensation in der Turbine zurückgeführt werden. Anhand von drei stationären Betriebspunkten wird die Zusammensetzung der Verluste innerhalb der Maschine gezeigt. Die Verzögerung wird zudem als kritisches Manöver im transienten Betrieb durch signifikante Abnahme des Pumpgrenzabstands identifiziert. / The performance of an electric turbocharger for the cathode gas supply system of an automotive fuel cell system is investigated considering moist air off gasses. Based on the component performance maps of electric motor, power electronics, bearings and turbomachinery, steady state and transient operating lines are calculated and a shift of operating points is shown. These can be traced back to the influence of gas composition and condensation within the turbine. Based on three operating points, losses inside the machine are characterized. Furthermore, deceleration is identified as the most critical transient operating scenario due to a significant decrease of the surge margin.
4

Vėdinimo įrenginių su integruotais šilumos siurbliais projektavimas, tyrimas ir analizė / Design, Research and Analysis of Air Handling Units with Air Source Heat Pumps

Bareika, Paulius 20 June 2013 (has links)
Magistro baigiamajame darbe nagrinėjami vėdinimo įrenginiai su integruotais šilumos siurbliais. Darbe atliekama tokios rūšies įrenginių literatūros apžvalga. Apžvelgiami šilumos siurblio komponentai, darantys didžiausią įtaką jo darbui. Darbo metu atlikti įrenginių projektavimo ir konstravimo darbai. Pateikiamos projektavimo rekomendacijos. Lyginami skirtingi kompresorių galios moduliacijos principai. Nagrinėjami įrenginių darbo režimai, kylančios problemos eksploatacijos metu, ieškomi problemų sprendimų būdai. Pateikiamos kintamo sukimosi greičio kompresorių galių moduliacijos ribos. Atliekamos energinė ir ekserginė analizės pagal eksperimentinio bandymo duomenis. Nustatomi realūs termodinaminio efektyvumo ir naudingumo koeficientai. Jautrumo analizės metu atliekami elektrinio šildytuvo efektyvumo ir naudingumo skaičiavimai. Pateikiami rezultatai, išvados ir rekomendacijos tokios rūšies įrenginių tobulinimui ir tolimesniam vystymui. Darbo apimtis – 94 psl. teksto be priedų, 66 iliustr., 7 lent., 43 bibliografiniai šaltiniai. / Master's thesis examines air handling units with integrated air source heat pumps. Literature review about this type of units was carried out. An overview of mostly important heat pump‘s components are given. Thesis was an opportunity to design, construct and analyze these units. Different heat pump‘s operation modes examined and main issues turned out. Based on experimental data variable speed compressor's capacity modulation results defined. Moist air thermodynamic calculations have been made and air handling unit with integrated air source heat pump experimental energy and exergy efficiency was defined. Sensitivity evaluation changing heat pump with electric heater carried out. The main recommendation provided for units designing and further development. Thesis consist of 94 p. text without appendixes, 66 pictures, 7 tables, 43 bibliographical entries.
5

Matematický model membránové destilace / Mathematical Model of Membrane Distillation

Hvožďa, Jiří January 2021 (has links)
Diplomová práce se zabývá membránovou destilací, především z matematické perspektivy. Jedná se o tepelně poháněný separační proces, ve kterém se pro rozdělení kapalné a plynné fáze používá porézní membrána. Kapalina se vypařuje a její plynná fáze prochází přes póry v membráně. Během tohoto procesu dochází k tepelné i látkové výměně, které jsou popsány systémem parciálních diferenciálnich rovnic. Další model je založen na analogii s elektrickými obvody, zákonu zachování energie, hmotnostní bilanci a empirických vztazích. Je ověřen s experimentálně naměřenými daty z nové alternativní destilační jednotky používající membránu a kondenzátor z polymerních dutých vláken. Výkon a účinnost jednotky jsou vyhodnoceny. Další možná vylepšení jsou navržena.
6

Klimatizační komora pro zpracování uzenin / Desing of a processing chamber for smoked goods production

Čermák, Lubomír January 2009 (has links)
The aim of the diploma thesis is to design a drying chamber for meat/salami processing. The design itself comes after the necessary information regarding meat drying and curing has been given. The chamber comprises a main frame, stainless steel chamber, chain conveyor, powertrain and a ductwork for the air treatment. All the parameters of moist air are given as calculated for the states encountered during the drying process, i.e. air dehumidification, when passing the cooling coil, and heating. The control system to meet the required environment condition is also suggested.
7

Zvýšení výkonu mikroturbíny pracující v nepřímém oběhu / Increased power microturbines operating in indirect circulation

Polák, Luboš January 2012 (has links)
Turbogenerator unit 100B TGU, produced in the First Brno Engineering Velká Bíteš a.s., works in Brayton indirect circulation. The aim of this work is the proposal to increase performance levels of technological unit in which the micro-turbine is applied. The work presents various ways to increase performance and efficiency of circulation. The possible options are compared with each of the technological and economic terms. Based on these criteria was selected variant feeding additional water into the circulation. For this design was the work of a mathematical model based on, which was established as the economic balance of the selected variants. The thesis also proposes a technological scheme, which is already incorporated the selected variant and an outline of the verification tests.
8

Vyrovnání provozních dat v energetických procesech / Data reconciliation of energy processes

Nováček, Adam January 2015 (has links)
This thesis is focused on problem data reconciliation of measurements. The objective of this thesis was reconciled measured value from electric drum dryer to suit exactly to the mathematical model of drying. For solution was used nonlinear data reconciliation with constrained nonlinear optimization. The entire calculation is processed in programme MATLAB and outputs are graphs of reconciled values of measurement on dryer such as inlet and outlet temperature and humidity, differential pressure of exhaust moisture air, weight of laundry, atmospheric pressure and electric supply. Achieved solution can by characterized by an amount of evaporated water. Weight of wet and dry laundry are 27,7 kg a 17,7 kg. The calculated amount of evaporated water from measurements was almost 18,8 kg. With reconciled measurements it was 9,7 kg. Goals of the thesis were found more realistic values.
9

Analyse, conception et expérimentation de procédés de stockage thermique résidentiel de longue durée par réaction thermochimique à pression atmosphérique / Seasonal storage of solar energy by thermochemical reactions at atmospheric pressure for household applications

Marias, Foivos Epameinondas 29 January 2015 (has links)
Les travaux présentés dans ce manuscrit de doctorat s'inscrivent dans la thématique du stockage inter-saisonnier de l'énergie solaire thermique pour l'habitat et le tertiaire (eau chaude sanitaire et chauffage). Le stockage thermochimique en air humide est une des solutions les plus prometteuses, en particulier avec un réacteur à lit fixe. Le bromure de strontium et l'alun de potassium ont été sélectionnés comme réactifs pour leurs caractéristiques énergétiques lors de réactions d'hydratation et de déshydratation. L'étude est constituée d'avancées théoriques, de nombreuses expérimentations et d'un modèle numérique détaillé. Une étude thermodynamique a démontré l'existence d'une droite de charge qui relie les conditions d'entrée et de sortie de l'air humide au passage du réactif. Les équations régissant les réactions chimiques, les transferts massiques et thermiques et la conservation de la quantité de mouvement ont été établies et un modèle numérique monodimensionnel couplant ces phénomènes a été développé. Des essais sur différents échantillons des deux sels et pour divers conditions opératoires ont été effectués dans le but de comprendre les phénomènes physico-chimiques ainsi que pour valider l'étude théorique et le modèle numérique. / This PhD thesis focuses on seasonal solar thermal energy storage for household applications such as production of heat and domestic hot water. Thermochemical storage was chosen for that purpose. The specific solid/gas reactions with water vapor, also called hydration/dehydration reactions, were used with a multi-scale global approach. The level of the reactor was identified as the critical level of that multi-scale approach. As a consequence, the integrated fixed-bed reactor technology in a moist air open loop system was adopted. A theoretical, experimental and numerical methodology was used for the study where strontium bromide and potassium alum salts were chosen as reactive materials. The corresponding reactions are: + 5 (H2O) ↔ (with Δhr=67.4 kJ/molwater and Δsr=175 J/K.molwater) + 9 (H2O) ↔ < KAl(SO4)2.12H2O > (with Δhr=44.2 kJ/molwater and Δsr=109.8 J/K.molwater) The first salt exhibits very good thermochemical properties. On the other hand, the main advantages of potassium alum are its low cost and the fact that it presents no sanitary risk. More than 30 cycles with 3 different samples of potassium alum and more than 25 cycles with 4 samples of strontium bromide under various stationary and dynamic operating conditions were carried out in order to understand the phenomena. The main experimental results were the following ones: • A very good stability and reproducibility of physical and chemical phenomena was observed for both materials. • A thermal reaction front was also observed. • A thermal hysteresis for both salts was found. • Based on that last observation a theoretical equation named charge-discharge line was developed. Experimental results with both salts validate the charge-discharge line theory. • A correlation between reaction kinetics, temperature rise due to the reaction, power of the reaction and the operating conditions was observed. The criterion for that correlation is the affinity of the reaction. A proportional correlation between affinity and reaction kinetics, temperature rise and power of the reaction was observed. • Spontaneous hydration and over-hydration reactions do not produce any particular difficulties or problems. • Pressure drop through the reactor and evolution of salts volume were also measured. Experimental energy density was measured in the range of 350 kWh/m3 for strontium bromide and 240 kWh/m3 for the potassium alum. • In general, strontium bromide is a very good candidate material for seasonal storage, while potassium alum cannot provide satisfying temperature rise and power. The equations governing those phenomena were also established and used to develop a 1D numerical model with partial differential equations coupling chemical phenomena, mass and thermal transfer phenomena and momentum conservation. Verification, validation and confirmation of this model under a very large range of operating conditions were carried out based on the experimental results of strontium bromide. A total of 19 different test cases were studied in order to validate the numerical model. The effect of humidity, temperature, quantity of reactive material and air flow were studied both for stationary and dynamic conditions. The numerical model was able to provide very satisfying results.

Page generated in 0.0636 seconds