1

Voltage interactions and commutation failure phenomena in multi-infeed HVDC systems

Rahimi, Ebrahim 27 September 2011 (has links)
This research attempts to quantify the complex interactions between HVDC transmission schemes in a multi-infeed configuration, particularly with regard to the voltage interactions and the commutation failure phenomena. The in-depth analysis of multi-infeed HVDC systems discussed in this research shows the application of several indices such as the MIIF, MIESCR, and CFII, that can provide researchers and planning engineers in the area of HVDC transmission with the necessary tools for their system studies. It shows that these indices are applicable in a multi-infeed system comprising HVDC schemes with different ratings. The Multi-Infeed Interaction Factor (MIIF) quantifies the level of voltage interactions between converter ac buses. The Multi-Infeed Effective Short Circuit Ratio (MIESCR) index is an indicator of ac system strengths with regard to the assessment of the transient overvoltage (TOV) and the power-voltage stability of multi-infeed HVDC systems. The Commutation Failure Immunity Index (CFII) utilizes electromagnetic transient simulation programs to evaluate the immunity of an HVDC converter to commutation failures. The CFII takes into account the ac system strength and the HVDC controls and evaluates their impact on the commutation process. The immunity of both single-infeed and multi-infeed systems to commutation failure phenomena are accurately evaluated and quantified by the CFII. Using the CFII, it is shown that the current commutation in multi-infeed HVDC schemes could fail under circumstances in which the probability of failure had been perceived to be low. The causes of, the effects of, and the remedial actions needed to deal with such anomalous commutation failures are discussed in this thesis. The capability of the new indices to provide an insight into the interactions phenomena in multi-infeed systems are clearly demonstrated by examples that show their application in the analysis of an actual multi-infeed HVDC system that is in the planning phase in the province of Alberta in Canada.
2

Voltage interactions and commutation failure phenomena in multi-infeed HVDC systems

Rahimi, Ebrahim 27 September 2011 (has links)
This research attempts to quantify the complex interactions between HVDC transmission schemes in a multi-infeed configuration, particularly with regard to the voltage interactions and the commutation failure phenomena. The in-depth analysis of multi-infeed HVDC systems discussed in this research shows the application of several indices such as the MIIF, MIESCR, and CFII, that can provide researchers and planning engineers in the area of HVDC transmission with the necessary tools for their system studies. It shows that these indices are applicable in a multi-infeed system comprising HVDC schemes with different ratings. The Multi-Infeed Interaction Factor (MIIF) quantifies the level of voltage interactions between converter ac buses. The Multi-Infeed Effective Short Circuit Ratio (MIESCR) index is an indicator of ac system strengths with regard to the assessment of the transient overvoltage (TOV) and the power-voltage stability of multi-infeed HVDC systems. The Commutation Failure Immunity Index (CFII) utilizes electromagnetic transient simulation programs to evaluate the immunity of an HVDC converter to commutation failures. The CFII takes into account the ac system strength and the HVDC controls and evaluates their impact on the commutation process. The immunity of both single-infeed and multi-infeed systems to commutation failure phenomena are accurately evaluated and quantified by the CFII. Using the CFII, it is shown that the current commutation in multi-infeed HVDC schemes could fail under circumstances in which the probability of failure had been perceived to be low. The causes of, the effects of, and the remedial actions needed to deal with such anomalous commutation failures are discussed in this thesis. The capability of the new indices to provide an insight into the interactions phenomena in multi-infeed systems are clearly demonstrated by examples that show their application in the analysis of an actual multi-infeed HVDC system that is in the planning phase in the province of Alberta in Canada.