• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação de desempenho de uma estação de tratamento de esgoto por lagoas de estabilização com chicanas /

Takeuti, Marcos Roberto Shoiti. January 2003 (has links)
Orientador : Tsunao Matsumoto / Banca: Roque Passos Piveli / Banca: Geraldo de Freitas Maciel / Resumo: Este trabalho teve como objetivo o monitoramento e avaliação da eficiência da Estação de Tratamento de Esgoto (ETE) na cidade de Santa Fé do Sul - SP, e a comparação dos resultados auferidos com ETEs da região. A Estação de Tratamento de Esgoto de Santa Fé do Sul investigada era composta de uma lagoa anaeróbia seguida por uma lagoa facultativa com 3 (três) divisores de fluxo (chicanas) paralelos, formando 4 (quatro) canais paralelos dentro da mesma, seguida por uma lagoa de maturação com apenas 1 (um) divisor de fluxo (chicanas) formando 2 (dois) canais paralelos, formando chicanas do tipo vai e vem. O monitoramento foi realizado no período de novembro de 2000 a junho de 2003. Os ensaios de investigação dos parâmetros de controle foram realizados em duas etapas, sendo a primeira etapa com quatro pontos de coletas realizadas quinzenalmente, no período de novembro de 2000 a junho de 2002, e a segunda etapa, com oito pontos de coletas com freqüência semanal, no período de março a junho de 2003. Os parâmetros investigados no monitoramento foram: DBO (mg/L), DQO (mg/L), OD, Temperatura (°C), pH, Sólidos Totais (mg/L), Sólidos Suspensos Totais (mg/L), Coliformes Totais (NMP/100mL) e Coliformes Fecais (NMP/100mL) das amostras coletadas em pontos de interesse ao longo das lagoas da ETE conforme etapas de investigação. Os parâmetros investigados e analisados na ETE durante o período de monitoramento foram animadores, apresentando valores de eficiência de remoção dos mesmos melhores em comparação as das ETEs da região. / Abstract: This work had as objective the accompaniment and evaluation of the efficiency of the Sewage Treatment Station of Santa Fé do Sul city, São Paulo state, Brazil, and the comparison of the obteined results with others stations of the same region. The station are composed with stabilization ponds. The first pond is anaerobic, followed by one facultative pond, with three parallel flow divisors (baffle), forming four parallel channels. This pond is followed by a maturation pond, with only one flow divisor (Baffle), forming two parallel channels. The accompaniment was accomplished in the period of november from 2000 to june of 2003. The chemical and bacteriological tests of investigation were accomplished in two stages. In the the first stage, the samples are collected in four different points every fifteen days, in the period of november of 2000 to june of 2002. In the second stage, the samples are collected in eigth different points every seven days, in the period of march to june of 2003. The parameters investigated in the acconpaniment were: Biochmical Oxygen Demand (BOD), Chemical Oxygen Demand (COD), Dissolved Oxygen (DO), Temperature (T), pH, Total Solids (TS), Total Suspended Solids (TSS), Total Coliforms, and Faecal Coliforms. The samples was collected in strategical points in the ponds, according to investigation stages. The investigated and analyzed parameters in station during the acconpaniment period were exciting, presenting better values of efficiency of removal of polluents in comparison with others stations of the region. / Mestre

Page generated in 0.1163 seconds