• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 1
  • 1
  • 1
  • Tagged with
  • 22
  • 22
  • 13
  • 11
  • 8
  • 7
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Projeto, construção e caracterização de um dosímetro para radiação de nêutrons

SOUTO, EDUARDO de B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:02Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:56Z (GMT). No. of bitstreams: 0 / Com o objetivo de monitorar o crescente número de trabalhadores potencialmente expostos à radiação de nêutrons, foi projetado e desenvolvido um dosímetro individual para campos mistos nêutron-gama. O dosímetro proposto foi caracterizado para o espectro de energia de uma fonte de Amerício-Berílio e para o intervalo de dose de interesse da proteção radiológica (até 20 mSv). Para tanto utilizou-se a dosimetria termoluminescente de albedo e a dosimetria de traços nucleares, técnicas consagradas na literatura internacional, empregando materiais de fabricação nacional e de baixo custo. Um policarbonato comercial, denominado SS-1, foi caracterizado para aplicação como detector sólido de traços nucleares. Os parâmetros para revelação química e ampliação dos traços, assim como a metodologia de avaliação dos detectores foram determinados. Estudou-se a resposta dos detectores TLD-600, TLD-700 e SS-1 em campos mistos nêutrongama de uma fonte de Amerício-Berílio e definiu-se um algoritmo para cálculo da dose de nêutrons e de radiação gama. A razão entre as respostas para nêutrons térmicos, de albedo e rápidos permite analisar o espectro ao qual o dosímetro foi submetido e corrigir a resposta do detector de traços para variações no ângulo de incidência da radiação. O novo dosímetro está pronto e apresenta desempenho para ser usado como dosímetro de nêutrons no Brasil. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
12

Aplicacao da tecnica de redes neurais em espectrometria e dosimetria de neutrons, utilizando esferas de Bonner e folhas de ativacao

BRAGA, CLAUDIA C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:45:28Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:12Z (GMT). No. of bitstreams: 1 07294.pdf: 5846807 bytes, checksum: a4bf44d31daa27de538647b817894a6c (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
13

Avaliacao dosimetrica da solucao fricke gel usando a tecnica de espectrofotometria para aplicacao na dosimetria de eletrons e neutrons / Dosimetric evaluation of the fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

MANGUEIRA, THYAGO F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:53Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:00:05Z (GMT). No. of bitstreams: 0 / Neste trabalho as principais características dosímetricas da solução Fricke Xilenol Gel (FXG) foram estabelecidas para futura aplicação clínica na dosimetria de elétrons. As curvas de dose resposta para feixes de nêutrons térmicos para pesquisa em Terapia por Captura de Nêutrons (BNCT) e feixes elétrons de aplicação industrial também foram determinadas. A técnica padrão de leitura utilizada foi espectrofotometria. Para o feixe clínico as reprodutibilidades intra e inter-lotes da solução FXG são melhores que 1,4 % e 5,1 % respectivamente, o comportamento da resposta para o intervalo de dose entre 0,2 e 40 Gy é linear e independente da energia e da taxa de dose para o intervalo estudado. Devido aos efeitos da oxidação natural do FXG o tempo ótimo entre o preparo e a irradiação é de 24h e o comportamento da curva de dose resposta não se altera no período estudado para a variação da absorvância líquida do dosímetro. Para o estudo com o campo de nêutrons as curvas de dose resposta do FXG apresentaram comportamento linear em todo intervalo de dose estudado, e para campos industriais de elétrons o comportamento é exponencial decrescente. De acordo com os resultados obtidos para os feixes de radiação estudados, não houve alteração na posição das bandas características do espectro de absorção do FXG. Como testes adicionais, foi determinada a viabilidade do uso do método de leitura do FXG por imagens fotográficas digitais e aplicação do FXG na dosimetria para braquiterapia intracavitária. O bom desempenho do dosímetro FXG nos testes realizados indica que este pode ser utilizado na avaliação tridimensional da dose em tratamento radioterápicos. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
14

Dosimetria de nêutrons / Neutron dosimetry

Luciano Fratin 20 September 1993 (has links)
Instalações para irradiação com nêutrons foram projetadas e construídas, visando o estabelecimento de procedimentos de calibração de monitores e dosímetros de nêutrons. Uma fonte calibrada de ANTPOT.241 AmBe com atividade de ANTPOT.185 GBq, garantiu rastreabilidade às medidas realizadas, e possibilitou irradiações com taxas de dose que variaram entre 9 nSv s POT.-1 e 0,5 muuSv s POT.-1. No arranjo elaborado para irradiações com nêutrons térmicos, com fluxo calibrado, a taxa de dose utilizada foi 50 nSv s POT.-1. A calibração de um espectrômetro de esferas de Bonner permitiu o estabelecimento dos procedimentos de calibração com base em três métodos propostos por normas internacionais, mostrando serem apropriadas às dimensões da sala de irradiação projetada para essa finalidade. A decoração do espectro de nêutrons, a partir da determinação dos parâmetros de calibração para o detector de esferas de Bonner, permitiu determinar o espectro da fonte de ANTPOT.241 AmBe calibrada, com valores de taxa de fluência, taxa de dose equivalente e energia media, que corresponderam satisfatoriamente aos valores calculados esperados, possibilitando o uso de tal detector na dosimetria de área. Para a dosimetria pessoal, foi elaborado um sistema dosimétrico baseado no uso do polímero CR-39 e no ataque eletroquímico do mesmo. Para isso, foram projetadas e construídas uma câmara para o processamento do detector e uma fonte de alta tensão e alta frequência que mostraram-se adequadas às finalidades propostas. O dosímetro pessoal elaborado utiliza também material conversor (n, alfa) e seu principio de detecção possibilitou determinar um fator de calibração relacionando a resposta do detector com a dose recebida para nêutrons térmicos, epitérmicos e rápidos. Os parâmetros utilizados para o ataque eletroquímico foram: solução de KOH 6N, temperatura de 59°C, campo elétrico alternado de 20 kv IND.ppcm POT.-1, frequência de 2,0 kHz; para a detecção de nêutrons térmicos e epitérmicos o tempo de revelação empregado foi de 3 horas e para nêutrons rápidos de 6 horas. O sistema dosimétrico desenvolvido apresentou sensibilidades a nêutrons térmicos, epitérmicos e rápidos dadas pelos valores (1,46 +/- 0,09) 10 POT.4 traços cm POT.-2 mSv POT.-1, (9 +/- 3) 10² traços cm POT.-2 mSv POT.-1 e (26 +/- 4) traços cm POT.-2 mSv POT.-1 respectivamente. As doses mínimas e máximas detectáveis foram respectivamente 0,002 mSv e 0,6 mSv para nêutrons térmicos, 0,04 mSv e 8 mSv para nêutrons epitérmicos e 1 mSv e 12 mSv para nêutrons rápidos. Tendo em vista as implicações das recomendações do ICRP-60, pode-se concluir que o dosímetro pessoal elaborado neste trabalho apresenta a sensibilidade necessária no caso da monitoração de nêutrons térmicos e epitérmicos, mas que exigiria tempos de integração de doses superiores à mensal no caso da monitoração de nêutrons rápidos.O procedimento proposto para ser realizar a dosimetria de nêutrons é baseado no uso conjugado do dosímetro pessoal elaborado e do espectrômetro de esferas de Bonner enquanto dosímetro de área. / A neutron irradiation facility was designed and built in order to establish a procedure for calibrating neutron monitors and dosimeters. A 185 GBq ANTPOT.241 AmBe source in the air provides neutron doses rates between 9 nSv s POT.-1 and 0,5 muuSv s POT.-1. A calibrated 50 nSv s POT.-1 thermal neutron field is obtained by using a specially designed paraffin block in conjunction with the ANTPOT.241 AmBe source. A Bonner multisphere spectrometer was calibrated, using a procedure based on three methods proposed by international standards. The unfolded ANTPOT.241 AmBe neutron spectrum was determined from Bonner spheres data and resulted in a good agreement with expected values for fluence rate, dose rate and mean energy. A dosimetric system based on the electrochemical etching of CR-39 was developed for personal dosimetry. The dosimeter badge using a (n, alfa) converter, the etching chamber and high frequency power supply were designed and built specially for this project. The electrochemical etching (ECE) parameters used were: a 6N KOH solution, 59°C, 20 kV IND.ppcm POT.-1, 2,0 kHz, 3 hours of ECE for thermal and intermediate neutrons and 6 hours for fast neutrons. The calibration factors for thermal, intermediate and fast neutrons were determined for this personal dosimeter. The sensitivies determined for the developed dosimetric system were (1,46 +/- 0,09)10 POT.4 tracks cm POT.-2 mSv POT.-1 for thermal neutrons, (9 +/- 3)10² tracks cm POT.-2 mSv POT.-1 for intermediate neutrons and (26 +/- 4) tracks cm POT.-2 mSv POT.-1 for fast neutrons. The lower and upper limits of detection were respectively 0,002 mSv and 0,6 mSv for thermal neutrons, 0,04 mSv and 8 mSv for intermediate neutrons and 1 mSv and 12 mSv for fast neutrons. In view of the 1990s ICRP recommendations, it is possible to conclude that the personal dosimeter described in this work is sufficiently sensitive to thermal and intermediate neutrons but fast neutron monitoring at radiological protection level would require an integration period of over a month. The proposed dosimetric procedure is based on the conjugated use of the developed personal dosimeter and the Bonner multisphere spectrometer.
15

Projeto, construção e caracterização de um dosímetro para radiação de nêutrons / Design, construction and characterization of a dosimeter for neutron radiation

Souto, Eduardo de Brito 30 March 2007 (has links)
Com o objetivo de monitorar o crescente número de trabalhadores potencialmente expostos à radiação de nêutrons, foi projetado e desenvolvido um dosímetro individual para campos mistos nêutron-gama. O dosímetro proposto foi caracterizado para o espectro de energia de uma fonte de Amerício-Berílio e para o intervalo de dose de interesse da proteção radiológica (até 20 mSv). Para tanto utilizou-se a dosimetria termoluminescente de albedo e a dosimetria de traços nucleares, técnicas consagradas na literatura internacional, empregando materiais de fabricação nacional e de baixo custo. Um policarbonato comercial, denominado SS-1, foi caracterizado para aplicação como detector sólido de traços nucleares. Os parâmetros para revelação química e ampliação dos traços, assim como a metodologia de avaliação dos detectores foram determinados. Estudou-se a resposta dos detectores TLD-600, TLD-700 e SS-1 em campos mistos nêutrongama de uma fonte de Amerício-Berílio e definiu-se um algoritmo para cálculo da dose de nêutrons e de radiação gama. A razão entre as respostas para nêutrons térmicos, de albedo e rápidos permite analisar o espectro ao qual o dosímetro foi submetido e corrigir a resposta do detector de traços para variações no ângulo de incidência da radiação. O novo dosímetro está pronto e apresenta desempenho para ser usado como dosímetro de nêutrons no Brasil. / An individual dosimeter for neutron-gamma mixed field dosimetry was design and developed aiming monitoring the increasing number of workers potentially exposed to neutrons. The proposed dosimeter was characterized to an Americium-Beryllium source spectrum and dose range of radiation protection interest (up to 20 mSv). Thermoluminescent albedo dosimetry and nuclear tracks dosimetry, traditional techniques found in the international literature, with materials of low cost and national production, were used. A commercial polycarbonate, named SS-1, was characterized for solid state tack detector application. The chemical etching parameters and the methodology of detectors evaluation were determined. The response of TLD-600, TLD-700 and SS-1 were studied and algorithms for dose calculation of neutron and gamma radiation of Americium- Beryllium sources were proposed. The ratio between thermal, albedo and fast neutrons responses, allows analyzing the spectrum to which the dosimeter was submitted and correcting the track detector response to variations in the radiation incidence angle. The new dosimeter is fully characterized, having sufficient performance to be applied as neutron dosimeter in Brazil.
16

Avaliação dosimétrica da solução fricke gel usando a técnica de espectrofotometria para aplicação na dosimetria de elétrons e nêutrons / Dosimetric evaluation of the fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

Mangueira, Thyago Fressatti 31 July 2009 (has links)
Neste trabalho as principais características dosímetricas da solução Fricke Xilenol Gel (FXG) foram estabelecidas para futura aplicação clínica na dosimetria de elétrons. As curvas de dose resposta para feixes de nêutrons térmicos para pesquisa em Terapia por Captura de Nêutrons (BNCT) e feixes elétrons de aplicação industrial também foram determinadas. A técnica padrão de leitura utilizada foi espectrofotometria. Para o feixe clínico as reprodutibilidades intra e inter-lotes da solução FXG são melhores que 1,4 % e 5,1 % respectivamente, o comportamento da resposta para o intervalo de dose entre 0,2 e 40 Gy é linear e independente da energia e da taxa de dose para o intervalo estudado. Devido aos efeitos da oxidação natural do FXG o tempo ótimo entre o preparo e a irradiação é de 24h e o comportamento da curva de dose resposta não se altera no período estudado para a variação da absorvância líquida do dosímetro. Para o estudo com o campo de nêutrons as curvas de dose resposta do FXG apresentaram comportamento linear em todo intervalo de dose estudado, e para campos industriais de elétrons o comportamento é exponencial decrescente. De acordo com os resultados obtidos para os feixes de radiação estudados, não houve alteração na posição das bandas características do espectro de absorção do FXG. Como testes adicionais, foi determinada a viabilidade do uso do método de leitura do FXG por imagens fotográficas digitais e aplicação do FXG na dosimetria para braquiterapia intracavitária. O bom desempenho do dosímetro FXG nos testes realizados indica que este pode ser utilizado na avaliação tridimensional da dose em tratamento radioterápicos. / In this work the main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a neutron field were also evaluated for the research in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometric. For the clinical field, the intra and inter-batch reproducibility are better than 1.4% and 5.1 %, respectively, the response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h period and the behavior of the dose-response curve of the FXG using the variation in the absorbance relative to the non-irradiated dosimeter as a basis during the whole studied period were not altered. The dose-response to the industrial electron beam presented an exponential decreasing behavior and the neutron beam for research in BNCT presented a linear behavior for the complete studied dose range. According to the obtained results for the different types of radiation studied for the FXG, there was no change in the position of the characteristic bands of the absorption spectrum due to the interaction of these radiation types. Additional tests were performed to determine the digital photographic imaging of FXG analyses viability and the application of FXG dosimetry on intracavitary brachytherapy. The good performance of the FXG dosimeter in the tests that were carried out indicates that this dosimeter may be applied to the tri-dimensional dose evaluation in radiotherapic treatments using electrons and neutron beams.
17

Projeto, construção e caracterização de um dosímetro para radiação de nêutrons / Design, construction and characterization of a dosimeter for neutron radiation

Eduardo de Brito Souto 30 March 2007 (has links)
Com o objetivo de monitorar o crescente número de trabalhadores potencialmente expostos à radiação de nêutrons, foi projetado e desenvolvido um dosímetro individual para campos mistos nêutron-gama. O dosímetro proposto foi caracterizado para o espectro de energia de uma fonte de Amerício-Berílio e para o intervalo de dose de interesse da proteção radiológica (até 20 mSv). Para tanto utilizou-se a dosimetria termoluminescente de albedo e a dosimetria de traços nucleares, técnicas consagradas na literatura internacional, empregando materiais de fabricação nacional e de baixo custo. Um policarbonato comercial, denominado SS-1, foi caracterizado para aplicação como detector sólido de traços nucleares. Os parâmetros para revelação química e ampliação dos traços, assim como a metodologia de avaliação dos detectores foram determinados. Estudou-se a resposta dos detectores TLD-600, TLD-700 e SS-1 em campos mistos nêutrongama de uma fonte de Amerício-Berílio e definiu-se um algoritmo para cálculo da dose de nêutrons e de radiação gama. A razão entre as respostas para nêutrons térmicos, de albedo e rápidos permite analisar o espectro ao qual o dosímetro foi submetido e corrigir a resposta do detector de traços para variações no ângulo de incidência da radiação. O novo dosímetro está pronto e apresenta desempenho para ser usado como dosímetro de nêutrons no Brasil. / An individual dosimeter for neutron-gamma mixed field dosimetry was design and developed aiming monitoring the increasing number of workers potentially exposed to neutrons. The proposed dosimeter was characterized to an Americium-Beryllium source spectrum and dose range of radiation protection interest (up to 20 mSv). Thermoluminescent albedo dosimetry and nuclear tracks dosimetry, traditional techniques found in the international literature, with materials of low cost and national production, were used. A commercial polycarbonate, named SS-1, was characterized for solid state tack detector application. The chemical etching parameters and the methodology of detectors evaluation were determined. The response of TLD-600, TLD-700 and SS-1 were studied and algorithms for dose calculation of neutron and gamma radiation of Americium- Beryllium sources were proposed. The ratio between thermal, albedo and fast neutrons responses, allows analyzing the spectrum to which the dosimeter was submitted and correcting the track detector response to variations in the radiation incidence angle. The new dosimeter is fully characterized, having sufficient performance to be applied as neutron dosimeter in Brazil.
18

Avaliação dosimétrica da solução fricke gel usando a técnica de espectrofotometria para aplicação na dosimetria de elétrons e nêutrons / Dosimetric evaluation of the fricke gel dosimeter using the spectrophotometric technique for application in electron and neutron dosimetry

Thyago Fressatti Mangueira 31 July 2009 (has links)
Neste trabalho as principais características dosímetricas da solução Fricke Xilenol Gel (FXG) foram estabelecidas para futura aplicação clínica na dosimetria de elétrons. As curvas de dose resposta para feixes de nêutrons térmicos para pesquisa em Terapia por Captura de Nêutrons (BNCT) e feixes elétrons de aplicação industrial também foram determinadas. A técnica padrão de leitura utilizada foi espectrofotometria. Para o feixe clínico as reprodutibilidades intra e inter-lotes da solução FXG são melhores que 1,4 % e 5,1 % respectivamente, o comportamento da resposta para o intervalo de dose entre 0,2 e 40 Gy é linear e independente da energia e da taxa de dose para o intervalo estudado. Devido aos efeitos da oxidação natural do FXG o tempo ótimo entre o preparo e a irradiação é de 24h e o comportamento da curva de dose resposta não se altera no período estudado para a variação da absorvância líquida do dosímetro. Para o estudo com o campo de nêutrons as curvas de dose resposta do FXG apresentaram comportamento linear em todo intervalo de dose estudado, e para campos industriais de elétrons o comportamento é exponencial decrescente. De acordo com os resultados obtidos para os feixes de radiação estudados, não houve alteração na posição das bandas características do espectro de absorção do FXG. Como testes adicionais, foi determinada a viabilidade do uso do método de leitura do FXG por imagens fotográficas digitais e aplicação do FXG na dosimetria para braquiterapia intracavitária. O bom desempenho do dosímetro FXG nos testes realizados indica que este pode ser utilizado na avaliação tridimensional da dose em tratamento radioterápicos. / In this work the main dosimetric characteristics of the Fricke Xylenol Gel (FXG) solution were established for further application in the measurement of dose distribution of clinical electron fields. The dose-response curves of the FXG in a neutron field were also evaluated for the research in Boron Neutron Capture Therapy (BNCT) and industrial electron fields. The standard reading technique was the spectrophotometric. For the clinical field, the intra and inter-batch reproducibility are better than 1.4% and 5.1 %, respectively, the response presents a linear behavior for doses ranging from 0.2 to 40 Gy independently of the energy and the dose rate in the studied ranges. Due to the effects of the FXG natural oxidation, the optimum elapsed time between FXG preparation and irradiation was established as 24h period and the behavior of the dose-response curve of the FXG using the variation in the absorbance relative to the non-irradiated dosimeter as a basis during the whole studied period were not altered. The dose-response to the industrial electron beam presented an exponential decreasing behavior and the neutron beam for research in BNCT presented a linear behavior for the complete studied dose range. According to the obtained results for the different types of radiation studied for the FXG, there was no change in the position of the characteristic bands of the absorption spectrum due to the interaction of these radiation types. Additional tests were performed to determine the digital photographic imaging of FXG analyses viability and the application of FXG dosimetry on intracavitary brachytherapy. The good performance of the FXG dosimeter in the tests that were carried out indicates that this dosimeter may be applied to the tri-dimensional dose evaluation in radiotherapic treatments using electrons and neutron beams.
19

Avaliação de dados nucleares para dosimetria de nêutrons / Evaluation of nuclear data for neutron dosimetry

TARDELLI, TIAGO C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:16Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:21Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
20

Avaliação de dados nucleares para dosimetria de nêutrons / Evaluation of nuclear data for neutron dosimetry

TARDELLI, TIAGO C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:16Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:21Z (GMT). No. of bitstreams: 0 / Doses absorvidas e doses efetivas podem ser calculadas utilizando códigos computacionais de transporte de radiação. A qualidade desses cálculos depende dos dados nucleares, no entanto, são raras as informações sobre as diferenças nas doses causadas por diferentes bibliotecas. O objetivo desse estudo é comparar os valores de dose (absorvida e efetiva) obtidos utilizando diferentes bibliotecas de dados nucleares devido a uma fonte externa de nêutrons na faixa de 10-11 a 20 MeV. As bibliotecas de dados nucleares são: JENDL 4.0, JEFF 3.1.1 e ENDF/B-VII.0. Cálculos de doses foram realizados utilizando o código MCNPX considerando o modelo antropomórfico da ICRP-110. As diferenças nos valores das doses absorvidas utilizando as bibliotecas JEFF 3.1.1 e a ENDF/B.VII são pequenas, em torno de 1%, porém os resultados obtidos com a JENDL 4.0 apresentam diferenças de até 85 % compara aos resultados da ENDF/B-VII.0 e JEFF 3.1.1. Diferenças nas doses efetivas são em torno de 1,5% entre ENDF/B-VII.0 e JEFF 3.1.1, e 11 % entre ENDF/B-VII.0 e JENDL 4.0. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP

Page generated in 0.0229 seconds