1 |
Nuclear activation techniques and methods of elemental concentration determination in bioenvironmental studiesFarooqi, Asad Saeed January 1991 (has links)
No description available.
|
2 |
Determination of silver using cyclic epithermal neutron activation analysisPun, Tin-Hei 26 October 2010 (has links)
A fast pneumatic transfer facility was installed at the Nuclear Engineering Teaching Laboratory (NETL) of the University of Texas at Austin for the purpose of cyclic thermal and epithermal neutron activation analysis. In this work efforts were focused on the evaluation of cyclic epithermal neutron activation analysis (CENAA). Various NIST and CANMET certified materials were analyzed by the system. Experiment results showed 110Ag as one of the isotopes favored by the system. Thus, the system was put into practical application for identifying silver concentration in the Arctic atmospheres in air filters collected in 2009, and traces in metallic ores Comparison of silver concentrations via CENAA with the CANMET certified reference materials gave very good results. / text
|
3 |
Development of a prompt-gamma, neutron-activation analysis facility at the Texas A&M University Nuclear Science CenterInyang, Otu Effiong 15 May 2009 (has links)
A prompt-gamma, neutron-activation analysis facility earlier developed at the Nuclear Science Center of Texas A&M University could not be used successfully to analyze geologic samples due to high detection background, low neutron fluence rate and poor detection equipment . A systematic investigation into the performance capability of a prompt-gamma, neutron activation analysis facility was undertaken in this research project. The facility was reconstructed and used to obtain prompt-gamma spectra of chlorine and cadmium and from the spectra, the net peak area counts for the most intense prompt-gamma-ray energies were obtained. A theoretical model was developed which can predict the net peak area counts expected on these prompt-gamma-ray energies using the thermal neutron fluence rate at the sample position, the absolute efficiency of the detector, and the mass and partial gamma-ray production cross section data for the samples. The experimental and predicted results were compared to establish the performance capability of the reconstructed facility. Good agreements between experimental and predicted results were obtained for chlorine, but results from cadmium showed larger discrepancies due to self-shielding effects. Corrections for self-shielding effects were applied to results from cadmium and the experimental and predicted results were also in good agreement. The satisfactory results indicate that it is possible to implement the prompt-gamma, neutron-activation analysis technique at Beam Port #1 of the Nuclear Science Center Reactor. To be able to obtain excellent results from other samples, improvements in shielding materials to attain a lower detection background and a highly efficient detection system should be incorporated.
|
4 |
Development of a prompt-gamma, neutron-activation analysis facility at the Texas A&M University Nuclear Science CenterInyang, Otu Effiong 15 May 2009 (has links)
A prompt-gamma, neutron-activation analysis facility earlier developed at the Nuclear Science Center of Texas A&M University could not be used successfully to analyze geologic samples due to high detection background, low neutron fluence rate and poor detection equipment . A systematic investigation into the performance capability of a prompt-gamma, neutron activation analysis facility was undertaken in this research project. The facility was reconstructed and used to obtain prompt-gamma spectra of chlorine and cadmium and from the spectra, the net peak area counts for the most intense prompt-gamma-ray energies were obtained. A theoretical model was developed which can predict the net peak area counts expected on these prompt-gamma-ray energies using the thermal neutron fluence rate at the sample position, the absolute efficiency of the detector, and the mass and partial gamma-ray production cross section data for the samples. The experimental and predicted results were compared to establish the performance capability of the reconstructed facility. Good agreements between experimental and predicted results were obtained for chlorine, but results from cadmium showed larger discrepancies due to self-shielding effects. Corrections for self-shielding effects were applied to results from cadmium and the experimental and predicted results were also in good agreement. The satisfactory results indicate that it is possible to implement the prompt-gamma, neutron-activation analysis technique at Beam Port #1 of the Nuclear Science Center Reactor. To be able to obtain excellent results from other samples, improvements in shielding materials to attain a lower detection background and a highly efficient detection system should be incorporated.
|
5 |
Aplicacao do metodo de ativacao neutronica a determinacao de mercurio total e outros elementos de interesse em amostras de solo e sedimento da Serra do Navio e Bacia do Rio Vila Nova, AmapaGONCALVES, CRISTINA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:17Z (GMT). No. of bitstreams: 1
05408.pdf: 10272523 bytes, checksum: f76b1c2fee05365386402c5aa1063133 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
6 |
Analise de elementos-traco presentes em aerossois da peninsula Antartica pelo metodo de ativacao com neutronsLOUREIRO, ANA L.M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:36:08Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:59:22Z (GMT). No. of bitstreams: 1
03968.pdf: 1649642 bytes, checksum: 95e6e89ec5ba0b4cdf75c95e00c7fb9a (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
7 |
Determinacao de componentes inorganicos em plasticos pelo metodo de analise por ativacao neutronicaMATEUS, SANDRA F. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:25:39Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:44Z (GMT). No. of bitstreams: 1
06789.pdf: 8523465 bytes, checksum: cf621ab32dfdca4609c1f77439a6f0f7 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
8 |
Desenvolvimento de um software de espectrometria gama para analise por ativacao com neutrons utilizando o conceito de codigo livre / Development of a gamma ray spectrometry software for neutron activation analysis using the open source conceptLUCIA, SILVIO R. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:55:19Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:56Z (GMT). No. of bitstreams: 0 / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
9 |
Determinacao de Pt, Pd, Ir e Au em materiais geologicos de referencia por analise por ativacao com neutrons: uma comparacao entre dois metodosNOGUEIRA, CLAUDIO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:38:26Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:29Z (GMT). No. of bitstreams: 1
05827.pdf: 4162110 bytes, checksum: 4818bf19a034f75fcbef60b0310a8176 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
10 |
Aplicacao do metodo de ativacao neutronica a determinacao de mercurio total e outros elementos de interesse em amostras de solo e sedimento da Serra do Navio e Bacia do Rio Vila Nova, AmapaGONCALVES, CRISTINA 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:42:43Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:57:17Z (GMT). No. of bitstreams: 1
05408.pdf: 10272523 bytes, checksum: f76b1c2fee05365386402c5aa1063133 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
|
Page generated in 0.0346 seconds