• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • Tagged with
  • 6
  • 6
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Utilização de partículas de ferro para remoção de Al, Cu e Ni em soluções sintéticas

Liendo, Maria Alejandra January 2011 (has links)
Nos últimos anos, têm surgido diversas resoluções a fim da proteção e conservação de águas subterrâneas no território brasileiro. Em conseqüência têm aumentado a necessidade de se desenvolver e se implementar métodos para prevenir e reduzir a contaminação destas águas. Uma das tecnologias emergentes para o tratamento in situ de águas subterrâneas são as barreiras permeáveis reativas - BPRs. Mediante estas, materiais relativamente econômicos, como por exemplo, o ferro são usados para remover diversos tipos de poluentes. No presente trabalho foi investigada a síntese e o uso de partículas de ferro para remover cátions metálicos, comumente achados em águas subterrâneas. Para tal fim foram avaliadas partículas de ferro obtidas mediante diferentes fontes: um produto comercial e partículas de ferro sintetizadas, sendo que uma fração das últimas foi modificada superficialmente. Foi avaliado o comportamento de soluções aquosas de sais de alumínio, cobre e níquel, em contato com as partículas. O procedimento experimental deste estudo incluiu a síntese e a caracterização das partículas obtidas; e os ensaios preliminares para observação da tendência de pH, concentração dos íons e potencial redox. Além disso, foi avaliada a cinética e o equilíbrio das soluções em contato com as partículas de ferro. Assim, com base nos resultados obtidos poder-se-ia concluir que é possível sintetizar-se em laboratório nanopartículas de ferro. Entretanto, devido ao método de síntese utilizado, estas possuem uma porcentagem de impurezas as quais podem afetar tanto as propriedades da solução, quanto às propriedades superficiais. Estas impurezas, no entanto, podem ser eliminadas mediante lavagem com água e/ou álcool. Além disso, as nanopartículas de ferro formam, em solução aquosa, uma camada de óxidos, a qual pode auxiliar na remoção de diferentes compostos. Os cátions de Al3+, Cu2+ e Ni2+ em solução aquosa podem ser removidos com as nanopartículas de ferro sintetizadas. A remoção do alumínio ocorre, majoritariamente, devido a mecanismos de precipitação e à co-precipitação. A remoção do cobre e níquel ocorre, majoritariamente devido a uma combinação de mecanismos de redução e adsorção. / In recent years, there have been several resolutions to protect and conserver the groundwater in Brazil. As a result has increased the need to develop and implement methods to prevent and reduce contamination of these waters resources. One of the emerging technologies for in situ treatment of groundwater is the permeable reactive barriers - PRBs. Through these, materials relatively inexpensive such as iron are used to remove several pollutants. In this study it was investigated the production and use of iron particles. They were used to remove metal cations commonly found in groundwater. For this purpose it was evaluated iron particles obtained from different sources: a commercial and a synthesized product. A fraction of the latter, was superficially modified. The aqueous solutions behavior of salts containing aluminum, copper and nickel, was evaluated individually in contact with the particles. The experimental procedure of the current work included the synthesis and characterization of the particles; and preliminary tests in order to observe the pH, the concentration and the potential redox trends. Furthermore, it was evaluated the kinetics and the equilibrium behavior of the solutions in contact with the iron particles. Hence, as a consequence of the obtained results, it could be say that it is possible to synthesize iron nanoparticles in the laboratory. However, due to the synthesis method used, they have a percentage of impurities that can affect both the solution and the surface properties. The impurities, however, can be removed through water or alcohol washing. Moreover, the iron nanoparticles obtained in aqueous solution has formed an iron oxide layer, which can assist the removal of several compounds. For this reason cations of aluminum, copper and nickel dissolved in aqueous solution can be removed with the synthesized iron nanoparticles. Removal of the aluminum occurs mainly due to precipitation and co-precipitation mechanism. The removal of copper and nickel occurs mostly due to a combination of adsorption and reduction mechanisms.
2

Utilização de partículas de ferro para remoção de Al, Cu e Ni em soluções sintéticas

Liendo, Maria Alejandra January 2011 (has links)
Nos últimos anos, têm surgido diversas resoluções a fim da proteção e conservação de águas subterrâneas no território brasileiro. Em conseqüência têm aumentado a necessidade de se desenvolver e se implementar métodos para prevenir e reduzir a contaminação destas águas. Uma das tecnologias emergentes para o tratamento in situ de águas subterrâneas são as barreiras permeáveis reativas - BPRs. Mediante estas, materiais relativamente econômicos, como por exemplo, o ferro são usados para remover diversos tipos de poluentes. No presente trabalho foi investigada a síntese e o uso de partículas de ferro para remover cátions metálicos, comumente achados em águas subterrâneas. Para tal fim foram avaliadas partículas de ferro obtidas mediante diferentes fontes: um produto comercial e partículas de ferro sintetizadas, sendo que uma fração das últimas foi modificada superficialmente. Foi avaliado o comportamento de soluções aquosas de sais de alumínio, cobre e níquel, em contato com as partículas. O procedimento experimental deste estudo incluiu a síntese e a caracterização das partículas obtidas; e os ensaios preliminares para observação da tendência de pH, concentração dos íons e potencial redox. Além disso, foi avaliada a cinética e o equilíbrio das soluções em contato com as partículas de ferro. Assim, com base nos resultados obtidos poder-se-ia concluir que é possível sintetizar-se em laboratório nanopartículas de ferro. Entretanto, devido ao método de síntese utilizado, estas possuem uma porcentagem de impurezas as quais podem afetar tanto as propriedades da solução, quanto às propriedades superficiais. Estas impurezas, no entanto, podem ser eliminadas mediante lavagem com água e/ou álcool. Além disso, as nanopartículas de ferro formam, em solução aquosa, uma camada de óxidos, a qual pode auxiliar na remoção de diferentes compostos. Os cátions de Al3+, Cu2+ e Ni2+ em solução aquosa podem ser removidos com as nanopartículas de ferro sintetizadas. A remoção do alumínio ocorre, majoritariamente, devido a mecanismos de precipitação e à co-precipitação. A remoção do cobre e níquel ocorre, majoritariamente devido a uma combinação de mecanismos de redução e adsorção. / In recent years, there have been several resolutions to protect and conserver the groundwater in Brazil. As a result has increased the need to develop and implement methods to prevent and reduce contamination of these waters resources. One of the emerging technologies for in situ treatment of groundwater is the permeable reactive barriers - PRBs. Through these, materials relatively inexpensive such as iron are used to remove several pollutants. In this study it was investigated the production and use of iron particles. They were used to remove metal cations commonly found in groundwater. For this purpose it was evaluated iron particles obtained from different sources: a commercial and a synthesized product. A fraction of the latter, was superficially modified. The aqueous solutions behavior of salts containing aluminum, copper and nickel, was evaluated individually in contact with the particles. The experimental procedure of the current work included the synthesis and characterization of the particles; and preliminary tests in order to observe the pH, the concentration and the potential redox trends. Furthermore, it was evaluated the kinetics and the equilibrium behavior of the solutions in contact with the iron particles. Hence, as a consequence of the obtained results, it could be say that it is possible to synthesize iron nanoparticles in the laboratory. However, due to the synthesis method used, they have a percentage of impurities that can affect both the solution and the surface properties. The impurities, however, can be removed through water or alcohol washing. Moreover, the iron nanoparticles obtained in aqueous solution has formed an iron oxide layer, which can assist the removal of several compounds. For this reason cations of aluminum, copper and nickel dissolved in aqueous solution can be removed with the synthesized iron nanoparticles. Removal of the aluminum occurs mainly due to precipitation and co-precipitation mechanism. The removal of copper and nickel occurs mostly due to a combination of adsorption and reduction mechanisms.
3

Utilização de partículas de ferro para remoção de Al, Cu e Ni em soluções sintéticas

Liendo, Maria Alejandra January 2011 (has links)
Nos últimos anos, têm surgido diversas resoluções a fim da proteção e conservação de águas subterrâneas no território brasileiro. Em conseqüência têm aumentado a necessidade de se desenvolver e se implementar métodos para prevenir e reduzir a contaminação destas águas. Uma das tecnologias emergentes para o tratamento in situ de águas subterrâneas são as barreiras permeáveis reativas - BPRs. Mediante estas, materiais relativamente econômicos, como por exemplo, o ferro são usados para remover diversos tipos de poluentes. No presente trabalho foi investigada a síntese e o uso de partículas de ferro para remover cátions metálicos, comumente achados em águas subterrâneas. Para tal fim foram avaliadas partículas de ferro obtidas mediante diferentes fontes: um produto comercial e partículas de ferro sintetizadas, sendo que uma fração das últimas foi modificada superficialmente. Foi avaliado o comportamento de soluções aquosas de sais de alumínio, cobre e níquel, em contato com as partículas. O procedimento experimental deste estudo incluiu a síntese e a caracterização das partículas obtidas; e os ensaios preliminares para observação da tendência de pH, concentração dos íons e potencial redox. Além disso, foi avaliada a cinética e o equilíbrio das soluções em contato com as partículas de ferro. Assim, com base nos resultados obtidos poder-se-ia concluir que é possível sintetizar-se em laboratório nanopartículas de ferro. Entretanto, devido ao método de síntese utilizado, estas possuem uma porcentagem de impurezas as quais podem afetar tanto as propriedades da solução, quanto às propriedades superficiais. Estas impurezas, no entanto, podem ser eliminadas mediante lavagem com água e/ou álcool. Além disso, as nanopartículas de ferro formam, em solução aquosa, uma camada de óxidos, a qual pode auxiliar na remoção de diferentes compostos. Os cátions de Al3+, Cu2+ e Ni2+ em solução aquosa podem ser removidos com as nanopartículas de ferro sintetizadas. A remoção do alumínio ocorre, majoritariamente, devido a mecanismos de precipitação e à co-precipitação. A remoção do cobre e níquel ocorre, majoritariamente devido a uma combinação de mecanismos de redução e adsorção. / In recent years, there have been several resolutions to protect and conserver the groundwater in Brazil. As a result has increased the need to develop and implement methods to prevent and reduce contamination of these waters resources. One of the emerging technologies for in situ treatment of groundwater is the permeable reactive barriers - PRBs. Through these, materials relatively inexpensive such as iron are used to remove several pollutants. In this study it was investigated the production and use of iron particles. They were used to remove metal cations commonly found in groundwater. For this purpose it was evaluated iron particles obtained from different sources: a commercial and a synthesized product. A fraction of the latter, was superficially modified. The aqueous solutions behavior of salts containing aluminum, copper and nickel, was evaluated individually in contact with the particles. The experimental procedure of the current work included the synthesis and characterization of the particles; and preliminary tests in order to observe the pH, the concentration and the potential redox trends. Furthermore, it was evaluated the kinetics and the equilibrium behavior of the solutions in contact with the iron particles. Hence, as a consequence of the obtained results, it could be say that it is possible to synthesize iron nanoparticles in the laboratory. However, due to the synthesis method used, they have a percentage of impurities that can affect both the solution and the surface properties. The impurities, however, can be removed through water or alcohol washing. Moreover, the iron nanoparticles obtained in aqueous solution has formed an iron oxide layer, which can assist the removal of several compounds. For this reason cations of aluminum, copper and nickel dissolved in aqueous solution can be removed with the synthesized iron nanoparticles. Removal of the aluminum occurs mainly due to precipitation and co-precipitation mechanism. The removal of copper and nickel occurs mostly due to a combination of adsorption and reduction mechanisms.
4

Avaliação do processo de transporte e remediação com nano ferro de valência zero em um solo residual contaminado com cromo hexavalente / Evaluation of transport process and remediation with nano zero valent iron in a residual contaminated soil with hexavalent chromiun

Reginatto, Cleomar January 2017 (has links)
O homem cada vez mais interfere e contamina o meio ambiente. Acidentes envolvendo o derramamento de substâncias químicas no solo tem sido cada vez mais frequente, gerando preocupação aos órgãos ambientais, visto que essa contaminação promove riscos à saúde humana, o que torna necessário intervenções que impulsionam o aprimoramento de técnicas de remediação. Dentre essas técnicas, a utilização de nanopartículas, em especial as nanopartículas de ferro de valência zero, têm se destacado para uso em remediação devido ao baixo custo de produção, elevada reatividade para contaminantes orgânicos e inorgânicos e baixa toxicidade. Para contaminantes inorgânicos não se tem definidas as melhores relações de nano ferro em relação ao contaminante e também o comportamento no solo. Dessa forma o objetivo do trabalho foi avaliar o transporte e a aplicação de nanopartículas de ferro para remediação de um solo residual argiloso, contaminado com cromo hexavalente. O trabalho foi dividido em três fases, em que na primeira foi avaliado a melhor concentração, tipo de nano ferro e determinação do parâmetro de filtração através do uso do ensaio em coluna de parede flexível com corpos de prova indeformados. Na segunda fase, a partir dos resultados da primeira, foram realizados ensaios de remediação do solo contaminado em bancada para se definir as melhores relações entre o nano ferro e o contaminante. E na terceira fase foram realizados ensaios com corpos de prova deformados e contaminados (800mg/Kg de Cr(VI)), para se avaliar a influência da pressão de injeção na eficiência do processo de redução do Cr (VI) Para realização dos ensaios de coluna, foi utilizado um solo residual argiloso, moldando-se corpos de prova de 5 cm de diâmetro e 5 cm de altura, utilizados na fase 1 e 3. Para avaliação do transporte e determinação do parâmetro de mobilidade de filtração foram utilizados 3 tipos de nanopartículas de ferro com e sem estabilizantes, nas concentrações de (1g/L, 4g/L, 7g/L e 10g/L), avaliando mudança na condutividade hidráulica do solo e concentração retida no meio. O parâmetro de filtração foi determinado utilizando-se o modelo analítico proposto por Reddy et al., (2014). Os resultados demonstram que as nanopartículas apresentam uma alta reatividade, porém baixa mobilidade para concentrações mais elevadas, tendo influência também o uso de estabilizantes. Os melhores valores obtidos nesta fase foram para concentrações de 1g/L e 4g/L, tanto para a mobilidade, quanto para a mudança na condutividade do meio O parâmetro de filtração, variou de 10-3s-1, para o nano ferro com surfactante e 10-2s-1, para o nano ferro sem surfactante. Para a remediação do cromo hexavalente se observou uma eficiência de 87% para a relação de 1000mg de Fe° para 23 mg de Cr(VI). Utilizando 4g/L na referida relação agente redutor e contaminante, em coluna se observou que maiores valores de pressão aumentam a eficiência da redução, porém acabam favorecendo a colmatação dos vazios do solo pelas nanopartículas. Utilizando uma pressão de 100Kpa, se obteve um valor de redução máximo próximo de 50%, muito menor que aqueles em bancada. Assim o uso de nanopartículas de ferro é eficiente para remediação de um solo argiloso contaminado com cromo (VI) ex situ, pois o contato do contaminante com o agente redutor se torna mais fácil pela melhor homogeneização do solo. As nanopartículas com surfactante apresentam melhor movimentação no solo e menor valor de filtração, sendo indicado o uso de uma concentração de até 4 g/L para não alterar as características naturais do meio. / The human being is constantly interfering and contaminating the environment. Accidents evolving the spill of chemical and toxic substances in the soil has been more frequently nowadays. This topic became a concern to the environmental regulation departments around the world, since this contaminations promote risks to the human health. In this way the necessity for improvements in the remediation techniques is required. Among the techniques, the use of nanoparticles zero valent iron has being highlight for use in remediation process due it's low cost for production, low toxicity and high reactivity for organic and inorganic contaminants. For inorganic contaminants the best nanoiron/contaminant ration and also the behavior in the soil have not been defined. Thus, the objective of this work was to evaluate the transport and the application of iron nanoparticles for the remediation of residual clay soil contaminated with hexavalent chromium The work is divided in three phases: The first evaluated the best concentration, type of nanoiron and determination of the filtration parameter through the use of the flexible wall column test with undeformed specimens. In the second phase, from the results of the first phase remediation tests were carried out on the contaminated soil in the workbench to define the best relations between the nanoiron and the contaminant. In the third phase, tests with deformed and contaminated test specimens (800 mg / kg Cr (VI)) were carried out to evaluate the influence of the injection pressure on the Cr (VI) reduction efficiency. To perform the column tests, a residual clay soil was used, molding test pieces 5 cm in diameter and 5 cm in height, used in phase 1 and 3. For evaluation of the transport and determination of the parameter of mobility of filtration (1 g / L, 4 g / L, 7 g / L and 10 g / L) were used, evaluating changes in soil hydraulic conductivity and the concentration retained in the system. The filtration parameter was determined using the analytical model proposed by Reddy et al., (2014).The results demonstrate that the nanoparticles have a high reactivity, but low mobility at higher concentrations, and also the use of stabilizers. The best values obtained in this phase were for concentrations of 1g/L and 4 g/L, both for mobility and for the change in conductivity of the system The filtration parameter ranged from 10-3s-1, for the nanoiron with surfactant and 10-2s-1, to the nanoiron without surfactant. For the remediation of the hexavalent chromium, an efficiency of 87% was observed for the ratio of 1000mg Fe ° to 23mg Cr (VI). By using 4g / L in the referred reducing agent and contaminant ratio, it was observed in column that higher pressure values increase the reduction efficiency, but they end up favoring the filling of the voids of the soil by the nanoparticles. Using a pressure of 100Kpa, a maximum reduction value of around 50% was obtained, much lower than those in bench. Thus, the use of iron nanoparticles is efficient for the remediation of a clay soil contaminated with chromium (VI) in deformed samples, since the contact of the contaminant with the reducing agent is made easier by better homogenization of the soil. The nanoparticles with surfactant present better a better movement in the soil and a lower filtration value, being indicated the use of a concentration of up to 4 g/l in order not to alter the natural characteristics of the system.
5

Avaliação do processo de transporte e remediação com nano ferro de valência zero em um solo residual contaminado com cromo hexavalente / Evaluation of transport process and remediation with nano zero valent iron in a residual contaminated soil with hexavalent chromiun

Reginatto, Cleomar January 2017 (has links)
O homem cada vez mais interfere e contamina o meio ambiente. Acidentes envolvendo o derramamento de substâncias químicas no solo tem sido cada vez mais frequente, gerando preocupação aos órgãos ambientais, visto que essa contaminação promove riscos à saúde humana, o que torna necessário intervenções que impulsionam o aprimoramento de técnicas de remediação. Dentre essas técnicas, a utilização de nanopartículas, em especial as nanopartículas de ferro de valência zero, têm se destacado para uso em remediação devido ao baixo custo de produção, elevada reatividade para contaminantes orgânicos e inorgânicos e baixa toxicidade. Para contaminantes inorgânicos não se tem definidas as melhores relações de nano ferro em relação ao contaminante e também o comportamento no solo. Dessa forma o objetivo do trabalho foi avaliar o transporte e a aplicação de nanopartículas de ferro para remediação de um solo residual argiloso, contaminado com cromo hexavalente. O trabalho foi dividido em três fases, em que na primeira foi avaliado a melhor concentração, tipo de nano ferro e determinação do parâmetro de filtração através do uso do ensaio em coluna de parede flexível com corpos de prova indeformados. Na segunda fase, a partir dos resultados da primeira, foram realizados ensaios de remediação do solo contaminado em bancada para se definir as melhores relações entre o nano ferro e o contaminante. E na terceira fase foram realizados ensaios com corpos de prova deformados e contaminados (800mg/Kg de Cr(VI)), para se avaliar a influência da pressão de injeção na eficiência do processo de redução do Cr (VI) Para realização dos ensaios de coluna, foi utilizado um solo residual argiloso, moldando-se corpos de prova de 5 cm de diâmetro e 5 cm de altura, utilizados na fase 1 e 3. Para avaliação do transporte e determinação do parâmetro de mobilidade de filtração foram utilizados 3 tipos de nanopartículas de ferro com e sem estabilizantes, nas concentrações de (1g/L, 4g/L, 7g/L e 10g/L), avaliando mudança na condutividade hidráulica do solo e concentração retida no meio. O parâmetro de filtração foi determinado utilizando-se o modelo analítico proposto por Reddy et al., (2014). Os resultados demonstram que as nanopartículas apresentam uma alta reatividade, porém baixa mobilidade para concentrações mais elevadas, tendo influência também o uso de estabilizantes. Os melhores valores obtidos nesta fase foram para concentrações de 1g/L e 4g/L, tanto para a mobilidade, quanto para a mudança na condutividade do meio O parâmetro de filtração, variou de 10-3s-1, para o nano ferro com surfactante e 10-2s-1, para o nano ferro sem surfactante. Para a remediação do cromo hexavalente se observou uma eficiência de 87% para a relação de 1000mg de Fe° para 23 mg de Cr(VI). Utilizando 4g/L na referida relação agente redutor e contaminante, em coluna se observou que maiores valores de pressão aumentam a eficiência da redução, porém acabam favorecendo a colmatação dos vazios do solo pelas nanopartículas. Utilizando uma pressão de 100Kpa, se obteve um valor de redução máximo próximo de 50%, muito menor que aqueles em bancada. Assim o uso de nanopartículas de ferro é eficiente para remediação de um solo argiloso contaminado com cromo (VI) ex situ, pois o contato do contaminante com o agente redutor se torna mais fácil pela melhor homogeneização do solo. As nanopartículas com surfactante apresentam melhor movimentação no solo e menor valor de filtração, sendo indicado o uso de uma concentração de até 4 g/L para não alterar as características naturais do meio. / The human being is constantly interfering and contaminating the environment. Accidents evolving the spill of chemical and toxic substances in the soil has been more frequently nowadays. This topic became a concern to the environmental regulation departments around the world, since this contaminations promote risks to the human health. In this way the necessity for improvements in the remediation techniques is required. Among the techniques, the use of nanoparticles zero valent iron has being highlight for use in remediation process due it's low cost for production, low toxicity and high reactivity for organic and inorganic contaminants. For inorganic contaminants the best nanoiron/contaminant ration and also the behavior in the soil have not been defined. Thus, the objective of this work was to evaluate the transport and the application of iron nanoparticles for the remediation of residual clay soil contaminated with hexavalent chromium The work is divided in three phases: The first evaluated the best concentration, type of nanoiron and determination of the filtration parameter through the use of the flexible wall column test with undeformed specimens. In the second phase, from the results of the first phase remediation tests were carried out on the contaminated soil in the workbench to define the best relations between the nanoiron and the contaminant. In the third phase, tests with deformed and contaminated test specimens (800 mg / kg Cr (VI)) were carried out to evaluate the influence of the injection pressure on the Cr (VI) reduction efficiency. To perform the column tests, a residual clay soil was used, molding test pieces 5 cm in diameter and 5 cm in height, used in phase 1 and 3. For evaluation of the transport and determination of the parameter of mobility of filtration (1 g / L, 4 g / L, 7 g / L and 10 g / L) were used, evaluating changes in soil hydraulic conductivity and the concentration retained in the system. The filtration parameter was determined using the analytical model proposed by Reddy et al., (2014).The results demonstrate that the nanoparticles have a high reactivity, but low mobility at higher concentrations, and also the use of stabilizers. The best values obtained in this phase were for concentrations of 1g/L and 4 g/L, both for mobility and for the change in conductivity of the system The filtration parameter ranged from 10-3s-1, for the nanoiron with surfactant and 10-2s-1, to the nanoiron without surfactant. For the remediation of the hexavalent chromium, an efficiency of 87% was observed for the ratio of 1000mg Fe ° to 23mg Cr (VI). By using 4g / L in the referred reducing agent and contaminant ratio, it was observed in column that higher pressure values increase the reduction efficiency, but they end up favoring the filling of the voids of the soil by the nanoparticles. Using a pressure of 100Kpa, a maximum reduction value of around 50% was obtained, much lower than those in bench. Thus, the use of iron nanoparticles is efficient for the remediation of a clay soil contaminated with chromium (VI) in deformed samples, since the contact of the contaminant with the reducing agent is made easier by better homogenization of the soil. The nanoparticles with surfactant present better a better movement in the soil and a lower filtration value, being indicated the use of a concentration of up to 4 g/l in order not to alter the natural characteristics of the system.
6

Avaliação do processo de transporte e remediação com nano ferro de valência zero em um solo residual contaminado com cromo hexavalente / Evaluation of transport process and remediation with nano zero valent iron in a residual contaminated soil with hexavalent chromiun

Reginatto, Cleomar January 2017 (has links)
O homem cada vez mais interfere e contamina o meio ambiente. Acidentes envolvendo o derramamento de substâncias químicas no solo tem sido cada vez mais frequente, gerando preocupação aos órgãos ambientais, visto que essa contaminação promove riscos à saúde humana, o que torna necessário intervenções que impulsionam o aprimoramento de técnicas de remediação. Dentre essas técnicas, a utilização de nanopartículas, em especial as nanopartículas de ferro de valência zero, têm se destacado para uso em remediação devido ao baixo custo de produção, elevada reatividade para contaminantes orgânicos e inorgânicos e baixa toxicidade. Para contaminantes inorgânicos não se tem definidas as melhores relações de nano ferro em relação ao contaminante e também o comportamento no solo. Dessa forma o objetivo do trabalho foi avaliar o transporte e a aplicação de nanopartículas de ferro para remediação de um solo residual argiloso, contaminado com cromo hexavalente. O trabalho foi dividido em três fases, em que na primeira foi avaliado a melhor concentração, tipo de nano ferro e determinação do parâmetro de filtração através do uso do ensaio em coluna de parede flexível com corpos de prova indeformados. Na segunda fase, a partir dos resultados da primeira, foram realizados ensaios de remediação do solo contaminado em bancada para se definir as melhores relações entre o nano ferro e o contaminante. E na terceira fase foram realizados ensaios com corpos de prova deformados e contaminados (800mg/Kg de Cr(VI)), para se avaliar a influência da pressão de injeção na eficiência do processo de redução do Cr (VI) Para realização dos ensaios de coluna, foi utilizado um solo residual argiloso, moldando-se corpos de prova de 5 cm de diâmetro e 5 cm de altura, utilizados na fase 1 e 3. Para avaliação do transporte e determinação do parâmetro de mobilidade de filtração foram utilizados 3 tipos de nanopartículas de ferro com e sem estabilizantes, nas concentrações de (1g/L, 4g/L, 7g/L e 10g/L), avaliando mudança na condutividade hidráulica do solo e concentração retida no meio. O parâmetro de filtração foi determinado utilizando-se o modelo analítico proposto por Reddy et al., (2014). Os resultados demonstram que as nanopartículas apresentam uma alta reatividade, porém baixa mobilidade para concentrações mais elevadas, tendo influência também o uso de estabilizantes. Os melhores valores obtidos nesta fase foram para concentrações de 1g/L e 4g/L, tanto para a mobilidade, quanto para a mudança na condutividade do meio O parâmetro de filtração, variou de 10-3s-1, para o nano ferro com surfactante e 10-2s-1, para o nano ferro sem surfactante. Para a remediação do cromo hexavalente se observou uma eficiência de 87% para a relação de 1000mg de Fe° para 23 mg de Cr(VI). Utilizando 4g/L na referida relação agente redutor e contaminante, em coluna se observou que maiores valores de pressão aumentam a eficiência da redução, porém acabam favorecendo a colmatação dos vazios do solo pelas nanopartículas. Utilizando uma pressão de 100Kpa, se obteve um valor de redução máximo próximo de 50%, muito menor que aqueles em bancada. Assim o uso de nanopartículas de ferro é eficiente para remediação de um solo argiloso contaminado com cromo (VI) ex situ, pois o contato do contaminante com o agente redutor se torna mais fácil pela melhor homogeneização do solo. As nanopartículas com surfactante apresentam melhor movimentação no solo e menor valor de filtração, sendo indicado o uso de uma concentração de até 4 g/L para não alterar as características naturais do meio. / The human being is constantly interfering and contaminating the environment. Accidents evolving the spill of chemical and toxic substances in the soil has been more frequently nowadays. This topic became a concern to the environmental regulation departments around the world, since this contaminations promote risks to the human health. In this way the necessity for improvements in the remediation techniques is required. Among the techniques, the use of nanoparticles zero valent iron has being highlight for use in remediation process due it's low cost for production, low toxicity and high reactivity for organic and inorganic contaminants. For inorganic contaminants the best nanoiron/contaminant ration and also the behavior in the soil have not been defined. Thus, the objective of this work was to evaluate the transport and the application of iron nanoparticles for the remediation of residual clay soil contaminated with hexavalent chromium The work is divided in three phases: The first evaluated the best concentration, type of nanoiron and determination of the filtration parameter through the use of the flexible wall column test with undeformed specimens. In the second phase, from the results of the first phase remediation tests were carried out on the contaminated soil in the workbench to define the best relations between the nanoiron and the contaminant. In the third phase, tests with deformed and contaminated test specimens (800 mg / kg Cr (VI)) were carried out to evaluate the influence of the injection pressure on the Cr (VI) reduction efficiency. To perform the column tests, a residual clay soil was used, molding test pieces 5 cm in diameter and 5 cm in height, used in phase 1 and 3. For evaluation of the transport and determination of the parameter of mobility of filtration (1 g / L, 4 g / L, 7 g / L and 10 g / L) were used, evaluating changes in soil hydraulic conductivity and the concentration retained in the system. The filtration parameter was determined using the analytical model proposed by Reddy et al., (2014).The results demonstrate that the nanoparticles have a high reactivity, but low mobility at higher concentrations, and also the use of stabilizers. The best values obtained in this phase were for concentrations of 1g/L and 4 g/L, both for mobility and for the change in conductivity of the system The filtration parameter ranged from 10-3s-1, for the nanoiron with surfactant and 10-2s-1, to the nanoiron without surfactant. For the remediation of the hexavalent chromium, an efficiency of 87% was observed for the ratio of 1000mg Fe ° to 23mg Cr (VI). By using 4g / L in the referred reducing agent and contaminant ratio, it was observed in column that higher pressure values increase the reduction efficiency, but they end up favoring the filling of the voids of the soil by the nanoparticles. Using a pressure of 100Kpa, a maximum reduction value of around 50% was obtained, much lower than those in bench. Thus, the use of iron nanoparticles is efficient for the remediation of a clay soil contaminated with chromium (VI) in deformed samples, since the contact of the contaminant with the reducing agent is made easier by better homogenization of the soil. The nanoparticles with surfactant present better a better movement in the soil and a lower filtration value, being indicated the use of a concentration of up to 4 g/l in order not to alter the natural characteristics of the system.

Page generated in 0.0864 seconds