• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Muon-induced ¹²B and ¹²N on Daya Bay reactor neutrino experiment

Liu, Sishuo, 劉思鑠 January 2014 (has links)
The Daya Bay neutrino experiment is designed for measuring the non-zero value for the neutrino mixing angle θ_13. For rare-event detection experiment such as neutrino detection, double-beta-decay experiments and dark-matter searches, cosmic ray muon produced radioactive isotopes are important background. Understanding more about the cosmic ray muon induced radioactive isotopes will help a lot with more precise measurements. My work here is to measure the absolute production yields of radioactive isotopes using different time windows and energy cuts and the associated work here is to extract different isotopes from the candidate events. Three different fitting methods are provided here for data analysis with Monte Carlo tests. Cross check of the result has been done with other group's work using different data selection criteria as well as fitting method. The power law for energy dependence of total cross-section for all muon-produced radioactive isotopes in scintillator target was tested using data from KamLAND [1] and Borexino [7] and using the result of a similar experiment at the SPS muon beam at CERN [23]. / published_or_final_version / Physics / Master / Master of Philosophy
2

Measurement of the calorimetric energy scale in MINOS

Hartnell, Jeffrey John January 2005 (has links)
MINOS is a long-baseline neutrino oscillation experiment. A neutrino beam is created at the Fermi National Accelerator Laboratory in Illinois and fired down through the Earth. Measurements of the energy spectra and composition of the neutrino beam are made both at the source using the Near detector and 735 km away at the Soudan Underground Laboratory in Minnesota using the Far detector. By comparing the spectrum and flavour composition of the neutrino beam between the two detectors neutrino oscillations can be observed. Such a comparison depends on the accuracy of the relative calorimetric energy scale. This thesis details a precise measurement of the calorimetric energy scale of the MINOS Far detector and Calibration detector using stopping muons with a new "track window" technique. These measurements are used to perform the relative calibration between the two detectors. This calibration has been accomplished to 1.7% in data and to significantly better than 2% in the Monte Carlo simulation, thus achieving the MINOS relative calibration target of 2%. A number of cross-checks have been performed to ensure the robustness of the calorimetric energy scale measurements. At the Calibration detector the test-beam energy between run periods is found to be consistent with the detector response to better than 2% after the relative calibration is applied. The muon energy loss in the MINOS detectors determined from Bethe-Bloch predictions, data and Monte Carlo are compared and understood. To estimate the systematic error on the measurement of the neutrino oscillation parameters caused by a relative miscalibration a study is performed. A 2% relative miscalibration is shown to cause a 0.6% bias in the values of Δm<sup>2</sup> and sin<sup>2</sup>(2θ).
3

mineral oil monitoring system for the Daya Bay neutrino experiment. / 應用於大亞灣中微子實驗的一套白油監測系統 / CUHK electronic theses & dissertations collection / A mineral oil monitoring system for the Daya Bay neutrino experiment. / Ying yong yu Daya Wan zhong wei zi shi yan de yi tao bai you jian ce xi tong

January 2013 (has links)
大亚湾反应堆中微子振荡实验通过在不同基线位置测量核电反应堆产生的反中微子的比率及其能量谱,达到精确测量中微子混合角θ₁₃,使sin²2θ₁₃ 的精度在90%置信水平不低于0.01。 / 大亚湾实验一共有8 个反中微子探测器,放置在3 个实验大厅中。反中微子探测器的基本设计是3 层同心圆柱结构:最外层是高5 米直径5 米的不锈钢钢罐,中间有两个有机玻璃罐,直径分别为4 米、3 米,高度分别为4 米、3 米。最内的有机玻璃罐装有掺钆的液体闪烁体,作为探测中微子的靶物质。中间层处于4 米有机玻璃罐与3 米罐之间,装有普通液体闪烁体,用于收集掺钆液体闪烁体中产生的γ 光子能量沉积。最外层是透明的白油,主要用来屏蔽来自钢罐与192 只光电倍增管的天然放射。这些光电倍增管都是安装在钢罐上,浸没于白油中,由液体闪烁体放出的光子全都要经过白油才能被光电倍增管接收,所以,我们需要监测白油光学性质的变化,确保实验结果能够达到精度目标。 / 我们设计并完成一套自动监测光在白油中的衰减的系统。此系统利用一颗高功率发光二极管发出光脉冲,经过50 米的光纤进入反中微子探测器中。通过单光仪内置的步进马达,可以选择特定波长的光进行监测。在反中微子探测器的底部装有一个隅角棱镜,它能把光纤射出的光反射回探测器的顶部,使得光在白油中的传播长度倍增至8 米左右。反射回来的光被白油监测系统的2 英寸光电倍增管接收,信号再通过一个高速模数转换器处理。比较反射信号与参考信号的大小,就可以监测白油对光强的衰减随时间的变化。 / 在本篇论文中,我会详细介绍白油监测系统的设计过程与安装完成后实际运行,取数以及分析的情况。 / The Daya Bay reactor neutrino experiment aims at measuring the neutrino mixing angle θ₁₃ with a sensitivity of 0.01 or better in sin²2θ₁₃ at the 90% confidence level, through a measurement of the relative rates and energy spectra of reactor anti-neutrinos at different baselines. / There are eight anti-neutrino detectors (AD) deployed in three experimental sites. The AD has a three-zone cylindrical structure. Two acrylic vessels with diameter of 3 m and 4 m, and height of 3 m and 4 m respectively, are nested inside a 5m-diameter stainless steel vessel (SSV). The inner most volume, confined by the 3m-diameter inner acrylic vessel (IAV), is filled with Gadolinium doped liquid scintillator (GdLS), which acts as the neutrino target. The medium volume between the IAV and the 4m-outer acrylic vessel (OAV), is filled with normal liquid scintillator (LS) to capture gamma particles emitted from the target. The outer most volume is filled with transparent mineral oil (MO) which shields radiations from the steel or the 192 photo- multipliers (PMT) from entering the target. Since all the PMTs are mounted near the stainless steel wall of the SSV in the MO, the photons emitted by the liquid scintillator have to travel through MO before being detected by the PMT. It is crucial to monitor the optical properties of the MO for achieving the sensitivity of 0.01 in sin²2 θ₁₃. / We have designed and developed an automatic system for monitoring the light attenuation in the MO. The system utilizes a high power LED to send light pulses into the AD through a 50 m optical fiber. With the stepping motor driven monochromator, we can select several wavelengths in one monitoring run. There is a corner cube retro-reflector at the bottom of the AD, which reflects the light back to the top of the AD, thus doubling the light path in the mineral oil to around 8 m. The reflected light is received by the 2" PMT of the MO monitoring system and digitized by a flash ADC. By comparing the reflected and reference signals of the LED pulses, we can monitor the attenuation in the MO. / I will discuss the detailed design and performance of this MO monitoring system and data taken in the AD calibration runs. / Detailed summary in vernacular field only. / Detailed summary in vernacular field only. / Detailed summary in vernacular field only. / Detailed summary in vernacular field only. / Chen, Xiaocong = 應用於大亞灣中微子實驗的一套白油監測系統 / 陳瀟聰. / Thesis (Ph.D.)--Chinese University of Hong Kong, 2013. / Includes bibliographical references (leaves 106-108). / Electronic reproduction. Hong Kong : Chinese University of Hong Kong, [2012] System requirements: Adobe Acrobat Reader. Available via World Wide Web. / Abstracts also in Chinese. / Chen, Xiaocong = ying yong yu Daya Wan zhong wei zi shi yan de yi tao bai you jian ce xi tong / Chen Xiaocong. / Chapter 1 --- Introduction of the Daya Bay Reactor Neutrino Experiment --- p.1 / Chapter 1.1 --- Neutrino Oscillation --- p.1 / Chapter 1.1.1 --- The Discovery of Neutrino --- p.1 / Chapter 1.1.2 --- Oscillation Phenomenology --- p.3 / Chapter 1.1.3 --- Disappearance Probability --- p.4 / Chapter 1.2 --- the Daya Bay Reactor Neutrino Experiment --- p.6 / Chapter 1.2.1 --- Knowledge of the Oscillation Parameters Before Daya Bay --- p.6 / Chapter 1.2.2 --- Overview of the Daya Bay Experiment --- p.8 / Chapter 1.2.3 --- Layout of the Experimental Halls --- p.10 / Chapter 1.2.4 --- Antineutrino Detection --- p.12 / Chapter 1.2.5 --- Relative Measurements --- p.13 / Chapter 1.2.6 --- Significance of θ₁₃ --- p.14 / Chapter 1.2.7 --- The Antineutrino Detector --- p.15 / Chapter 1.2.8 --- Devices on the AD Lid --- p.17 / Chapter 1.3 --- Physics Result from the Daya Bay Experiment --- p.18 / Chapter 2 --- Design and Prototyping of the Mineral Oil Clarity Monitoring System --- p.20 / Chapter 2.1 --- Design --- p.20 / Chapter 2.1.1 --- Motivation of the Mineral Oil Clarity Monitoring System --- p.20 / Chapter 2.1.2 --- Attenuation of Mineral Oil --- p.24 / Chapter 2.1.3 --- MO Clarity Monitoring Scheme --- p.26 / Chapter 2.1.4 --- The Light Source for the MO Clarity Monitoring System --- p.28 / Chapter 2.1.5 --- Hardware inside the MO Clarity Box --- p.31 / Chapter 2.2 --- Prototyping of the Mineral Oil Clarity Monitoring System --- p.34 / Chapter 2.2.1 --- The Setup of the Prototype --- p.34 / Chapter 2.2.2 --- Stability Test of the Prototype --- p.36 / Chapter 2.2.3 --- Tolerance against the Deformation of the AD Lid --- p.39 / Chapter 2.2.4 --- Summary of the Tests on the Prototype --- p.40 / Chapter 3 --- Production and Installation of the Hong Kong Mineral Oil Clarity System --- p.42 / Chapter 3.1 --- Production and Component Tests --- p.42 / Chapter 3.1.1 --- Corner Cube Retroreflector --- p.42 / Chapter 3.1.2 --- Optical Fiber --- p.43 / Chapter 3.1.3 --- Calibration of the Monochromator --- p.45 / Chapter 3.1.4 --- Absolute Gain Measurement of the 2" PMT --- p.46 / Chapter 3.1.5 --- the Flash-ADC --- p.51 / Chapter 3.1.6 --- The Diffuser Ball --- p.53 / Chapter 3.2 --- Onsite Installation --- p.57 / Chapter 3.2.1 --- The Corner Cube --- p.57 / Chapter 3.2.2 --- Installation of the Acrylic Window and Leak Checking . --- p.58 / Chapter 3.2.3 --- Optical Alignment of the Collimator --- p.65 / Chapter 3.2.4 --- Cabling --- p.66 / Chapter 4 --- Operation of the MO Clarity Monitoring System --- p.68 / Chapter 4.1 --- Commissioning of the MO Clarity Monitoring System --- p.68 / Chapter 4.2 --- Data Processing --- p.70 / Chapter 4.2.1 --- Fitting of the PMT Waveforms --- p.71 / Chapter 4.2.2 --- Numerical Integration of the Peaks in the PMT Waveform --- p.75 / Chapter 4.3 --- EMI Pickup Problem --- p.79 / Chapter 4.4 --- MO Clarity Monitoring Results for the Eight ADs --- p.84 / Chapter 4.4.1 --- AD1 --- p.84 / Chapter 4.4.2 --- AD2 --- p.86 / Chapter 4.4.3 --- AD3 --- p.88 / Chapter 4.4.4 --- AD4 --- p.90 / Chapter 4.4.5 --- AD5 --- p.92 / Chapter 4.4.6 --- AD6 --- p.93 / Chapter 4.4.7 --- AD7 --- p.95 / Chapter 4.4.8 --- AD8 --- p.96 / Chapter 4.5 --- Comparison with Simulation Result --- p.98 / Chapter 4.5.1 --- Introduction of the NuWa Simulation --- p.98 / Chapter 4.5.2 --- Simulation Result with Displacement of the Optical Hole --- p.99 / Chapter 4.5.3 --- Possible Cause for the Large Uncertainty in the MO Monitoring Run for Some ADs --- p.100 / Chapter 4.6 --- Precision of the MO Monitoring System and Stability of the MO Attenuation Length --- p.102 / Chapter 5 --- Summary --- p.104 / Bibliography --- p.105
4

Implementing a data analysis system for the calibration of an iodine neutrino detector

Sages, Harry M. January 1997 (has links)
This study presents a comprehensive overview of the significance and results of implementing a data analysis for the calibration of an iodine neutrino detector. Previous neutrino detectors have failed to confirm the standard solar model or settle the question of a massive neutrino. An iodine detector, which was proposed in 1988, is being constructed to hopefully resolve these issues. Before the iodine detector can give conclusive results, it must first be calibrated. Because there is no standard neutrino source, these calibrations must be done indirectly. The method for calibrating the 127-Iodine detector is by using a (p,n) reaction at 0' on an iodine target and a proton beam provided by the Indiana University Cyclotron FacHity (IUCF). When a neutrino is captured by 127-Iodine, the nucleus becomes an excited state of 127-Xenon at an energy of 125 keV. By measuring the Gwnow Teller strength fimction of the transition from the ground state in 127-Iodine to the 125 keV excited state in 127-Xenon, the iodine detector can be suitably calibrated. / Department of Physics and Astronomy

Page generated in 0.0849 seconds