Imagens ultra-sônicas em modo-B com técnicas de abertura focal sintética - SAFT. / Ultrasonic imaging in B-mode with synthetic aperture focusing tecnique - SAFT.

Jinbo, Maro 02 April 2007 (has links)
Este trabalho trata do estudo e aplicação da técnica de abertura focal sintética (SAFT) na geração de imagens por ultra-som em modo-B com transdutores matriciais lineares, para aplicação em ensaios não destrutivos. Sinais em modo-A são adquiridos e armazenados correspondentes ao meio inspecionado. Implementaram-se duas estratégias de processamento baseadas no método SAFT. A primeira consiste em um elemento central do array emitindo e todos recebendo, resultando em imagens com uma baixa energia acústica envolvida. A outra estratégia considera cada um dos elementos do array emissores e receptores gerando imagens de melhor qualidade, mas requer um maior tempo de processamento. Aplicaram-se técnicas de processamento digital de sinais como: filtragem, extração da envoltória, retificação, compressão logarítmica, interpolação e janelas de ponderação. Arquivos de dados foram gerados com um array de 128 elementos pelos pesquisadores da Universidade de Michigan e disponibilizados no site. Esses foram utilizados para a elaboração e otimização dos algoritmos no MatlabR. As imagens obtidas foram analisadas com relação a alguns parâmetros como a resolução axial e lateral, o contraste e o tempo de processamento. Foi confeccionado, no Laboratório de Ultra-Som da Escola Politécnica da Universidade de São Paulo, transdutor array de 16 elementos. Realizaram-se experimentos, adquirindo-se sinais que foram processados, gerando imagens referentes ao meio inspecionado. / This work deals with the study and application of the synthetic aperture focusing technique (SAFT) for generating ultrasonic images in mode-B with linear array transducers for nondestructive testing applications. Modo-A signals are acquired and stored corresponding to the inspected medium. It was implemented two processing strategies based on SAFT. The first one consists of an array emitting with the central element and receiving with all the elements, resulting in images with a low acoustic energy involved. The second considers each one of the emitting and receiving elements of the array, generating images of better quality but requiring a longer processing time. Digital signal processing techniques were applied such as: filtering, envelope detection, rectification, logarithmic compression, interpolation, and weighting windows. Data were generated with a 128-element array by researchers from the University of Michigan and made available at the institution website. These data were used for elaborating and optimizing the algorithms using MatlabR. The acquired images were analyzed regarding some parameters as axial and lateral resolution, contrast and the processing time. A 16-element array was confectioned in the Ultrasound Laboratory of the School of Engineering at the University of São Paulo. Experiments were conducted and signals were acquired and processed, resulting in images of the inspected medium.
2

Imagens ultra-sônicas em modo-B com técnicas de abertura focal sintética - SAFT. / Ultrasonic imaging in B-mode with synthetic aperture focusing tecnique - SAFT.

Maro Jinbo 02 April 2007 (has links)
Este trabalho trata do estudo e aplicação da técnica de abertura focal sintética (SAFT) na geração de imagens por ultra-som em modo-B com transdutores matriciais lineares, para aplicação em ensaios não destrutivos. Sinais em modo-A são adquiridos e armazenados correspondentes ao meio inspecionado. Implementaram-se duas estratégias de processamento baseadas no método SAFT. A primeira consiste em um elemento central do array emitindo e todos recebendo, resultando em imagens com uma baixa energia acústica envolvida. A outra estratégia considera cada um dos elementos do array emissores e receptores gerando imagens de melhor qualidade, mas requer um maior tempo de processamento. Aplicaram-se técnicas de processamento digital de sinais como: filtragem, extração da envoltória, retificação, compressão logarítmica, interpolação e janelas de ponderação. Arquivos de dados foram gerados com um array de 128 elementos pelos pesquisadores da Universidade de Michigan e disponibilizados no site. Esses foram utilizados para a elaboração e otimização dos algoritmos no MatlabR. As imagens obtidas foram analisadas com relação a alguns parâmetros como a resolução axial e lateral, o contraste e o tempo de processamento. Foi confeccionado, no Laboratório de Ultra-Som da Escola Politécnica da Universidade de São Paulo, transdutor array de 16 elementos. Realizaram-se experimentos, adquirindo-se sinais que foram processados, gerando imagens referentes ao meio inspecionado. / This work deals with the study and application of the synthetic aperture focusing technique (SAFT) for generating ultrasonic images in mode-B with linear array transducers for nondestructive testing applications. Modo-A signals are acquired and stored corresponding to the inspected medium. It was implemented two processing strategies based on SAFT. The first one consists of an array emitting with the central element and receiving with all the elements, resulting in images with a low acoustic energy involved. The second considers each one of the emitting and receiving elements of the array, generating images of better quality but requiring a longer processing time. Digital signal processing techniques were applied such as: filtering, envelope detection, rectification, logarithmic compression, interpolation, and weighting windows. Data were generated with a 128-element array by researchers from the University of Michigan and made available at the institution website. These data were used for elaborating and optimizing the algorithms using MatlabR. The acquired images were analyzed regarding some parameters as axial and lateral resolution, contrast and the processing time. A 16-element array was confectioned in the Ultrasound Laboratory of the School of Engineering at the University of São Paulo. Experiments were conducted and signals were acquired and processed, resulting in images of the inspected medium.
3

Aplicação do ensaio de Eddy Current Phased Array em componentes aeroespaciais

João Carlos Matarezi 15 December 2009 (has links)
Na área de Ensaios Não Destrutivos, o ensaio por eddy current (correntes parasitas) é uma técnica eletromagnética largamente utilizada nas indústrias aeroespacial, nuclear e petroquímica. Esse ensaio detecta descontinuidades superficiais e subsuperficiais, prevenindo acidentes. A técnica phased array surgiu para suprir carências, como o enorme tempo gasto para execução do ensaio em materiais de geometria complexa e falta de registro do ensaio. Essa técnica, já bastante utilizada em outros países, ainda é pouco utilizada no Brasil, por não haver estudos que comprovem a viabilidade econômica, os níveis de detectabilidade de descontinuidades e a confiabilidade dos resultados. Este trabalho tem como objetivo comparar as técnicas do ensaio por Correntes Parasitas convencional com a técnica por phased array, em materiais e peças especificamente utilizados no setor aeronáutico e espacial. Foram selecionadas amostras de materiais e peças, para que pudessem ser aplicadas ambas as técnicas e comparados os resultados. Foi realizado um levantamento bibliográfico das principais normas e especificações utilizadas neste segmento, para verificar a compatibilidade dos métodos. Para atender ao objetivo deste trabalho, foram realizados sete experimentos, variando o material e as técnicas. Após a realização dos ensaios, observou-se uma grande redução de tempo na execução do ensaio, com consequente redução de custos e maior detectabilidade das descontinuidades, com o uso da técnica por phased array. Portanto, baseado nos resultados encontrados, pode-se afirmar que a técnica por phased array pode ser utilizada neste segmento, com vantagens sobre a técnica convencional. / In the area of nondestructive testing, eddy current testing is an electromagnetic technique widely used in aerospace, nuclear and petrochemical industries. This test detects surface and subsurface discontinuities, preventing accidents. Phased array technique has emerged to fill in the gaps, as the enormous time spent implementing the test of large parts or complex geometry and lack of trial registration. This technique, already widely used in others countries, is not used in Brazil, there is no studies proving the economic viability, levels of detectability of discontinuities and reliability of the results. This study aims to compare the conventional technique by eddy current testing with phased array technique, in particular materials and parts used in aeronautics and space sector. Samples of materials and parts were prepared, so that could be applied both techniques and compared the results. A literature survey of the main standards and specifications for this segment was conducted to verify the compatibility of the methods. To meet the objective of this work, seven experiments were performed, varying the material and techniques. After the tests, there was a significant time reduction with the use of phased array technique, costs reduction and increased detectability of discontinuities. Based on the results, it can be said that phased array technique can be used in this segment, with advantages over the conventional technique.