• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 110
  • 14
  • 3
  • 1
  • Tagged with
  • 128
  • 45
  • 32
  • 22
  • 18
  • 17
  • 15
  • 14
  • 14
  • 14
  • 13
  • 13
  • 13
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Uma perspectiva pancromática no infravermelho (IR) para análise do complexo IC 5146

Nunes, Natália Amarinho January 2016 (has links)
Ao longo das últimas décadas, observações no IR obtidas pelo telescópio espacial Spitzer aumentaram significantemente a população conhecida de YSOs associados as nuvens moleculares próximas. Com tal censo, estudos recentes têm caracterizado estelas PMS e deteminado parâmetros em diferentes comprimentos de onda. Dada a cobertura restrita de algumas destas nuvens, relativo às suas regiões estendidas, estas populações de YSOs podem representar uma visão limitada da formação estelar nestas regiões. Diante disso, aproveitamos observações no IR médio do WISE, que fornece uma cobertura maior do céu, podendo assim apresentar uma maior população representativa de YSO. Nós estendemos o método de classificação bem estabelecido por Allen et al.(2004) para observações do Spitzer e WISE. Adotamos a fotometria 2MASS como sistema padrão para comparações. Além do aglomerado embebido IC 5146, nós fornecemos uma visão em diversas bandas fotométricas dos 5 novos aglomerados estelares embebidos e sua vizinhança. Em suma, a análise da amostra envolve os seguintes passos: (i) extração fotométricas (2MASS, Spitzer e WISE) de uma região circular; (ii) descontaminação de estrelas de campo para reforçar a morfologia intrínseca do diagrama Cor-magnitude (CMD) (essencial para determinar o avermelhamento, idade e distância do Sol); e (iii) construção de filtros cor-magnitude, para os perfis radiais de densidade estelar (RDPs). Os perfis foram construídos com estrelas selecionadas após a aplicação filtro cor-magnitude (CM) sobre a fotometria observada, o qual isola estrelas com grande probabilidade de serem membros do aglomerado. A distância do IC 5146 foi estimada num valor de 1190 ± 70 pc do Sol. Tal distância tem sido questão de debate na literatura. Entretanto, as distâncias e as incertezas fotométricas dos 5 NBBs sugerem que eles estão associados fisicamente. Estes novos YSOs descobertos, IC 5146 e Streamer possuem idade de 5 ± 3Myr. Concluímos que todo o complexo IC5146 sugere-nos uma concordância morfológica associada com o processo de formação estelar. / Throughout the last decade sensitive infrared observations obtained by the Spitzer Space Telescope signi cantly increased the known population of YSOs associated with nearby molecular clouds. With such a census recent studies have characterized pre-main sequence stars (PMS) and determined parameters from di erent wavelengths. Given the restricted Spitzer coverage of some of these clouds, relative to their extended regions, these YSO populations may represent a limited view of star formation in these regions. We are taking advantage of mid-infrared observations from the NASA Wide Field Infrared Survey Explorer (WISE), which provides an all sky view and therefore full coverage of the nearby clouds, to assess the degree to which their currently known YSO population may be representative of a more complete population. We extend the well established classi cation method of the Spitzer Legacy teams to archived WISE observations. We have adopted 2MASS photometry as a "standard catalogue" for comparisons. Besides the massive embedded cluster IC 5146 we provide a multiband view of ve new embedded clusters in its surroundings that we discovered with WISE. In short, the analysis involves the following for the presently studied cluster sample: (i) extraction of 2MASS/WISE/Spitzer photometry in a wide circular region; (ii) eld-star decontamination to enhance the intrinsic Colour-magnitude diagram (CMD) morphology (essential for a proper derivation of reddening, age, and distance from the Sun); and (iii) construction of Colour-magnitude lters, for more contrasted stellar radial density pro les (RDPs).
12

CaracterizaÃÃo da MicrofÃsica das Nuvens sobre a AmazÃnia Brasileira em RegiÃes de Pasto e Floresta Medida em Situ por AviÃo Instrumentado e sua AplicaÃÃo Direta no Modelo Regional Rams

AntÃnio Carlos Santana dos Santos 22 July 2005 (has links)
nÃo hà / Conhecer a microfÃsica de nuvens à fundamental para o entendimento da dinÃmica, bem como a sua aplicaÃÃo direta em modelos regionais de tempo e clima. O trabalho proposto nesta tese tem o objetivo de verificar o comportamento dinÃmico e microfÃsico de nuvens amazÃnicas e, em particular, comparar esse comportamento para nuvens sobre as regiÃes de pasto e floresta no Estado de RondÃnia. Diversas medidas termodinÃmicas e microfisicas obtidas in situ com o aviÃo laboratÃrio Citation II foram analisadas, sendo possÃvel extrair algumas conclusÃes relativas ao comportamento microfÃsico das nuvens formadas sobre pasto e floresta. TambÃm foram feitas diversas simulaÃÃes com o modelo RAMS (Regional Atmospheric Model System): testes de sensibilidade em relaÃÃo à cobertura vegetal (pasto ou floresta), que nÃo apresentaram diferenÃas significativas no perfil vertical da microfÃsica das nuvens; simulaÃÃes feitas inicializando o modelo com o diÃmetro mÃdio ou com a concentraÃÃo de gotÃculas, cujos resultados apresentaram diferenÃas significativas. Os resultados obtidos nas simulaÃÃes inicializadas com a concentraÃÃo de partÃculas mostraram-se bastante prÃximos daqueles observados durante o experimento ABRACOS (Anglo-Brazilian Amazonian Climate Observation Study). / Improving or knowledge on cloud microphysics is fundamental to understand the clouds dynamics, its role in the atmospheric general circulation and energy balance, as well as in weather and climate prediction applications using large-scale and mesoscale models. This work aims to verify the dynamic and microphysical behavior of clouds over the Amazon basin and, in particular, to compare those behaviors over pasture and forest areas in RondÃnia State. Several thermodynamic and microphysics measurements obtained in situ with the University of North Dakota instrumented aircraft (Citation II) were analyzed, allowing us to reach some conclusions about the microphysical and dynamical characteristics of clouds over pasture and forest areas. Cloud-resolving simulations using RAMS model (Regional Atmospheric Model System) were performed in order to assess sensitivities regarding vegetation cover (pasture or forest). The simulations did not show significant differences in the average vertical profiles of cloud microphysics variables (such as mixing rations for the different hydrometeor species). On the other hand, simulations using different model setups (changes in initialization or average diameter or droplets concentration), produced significant differences in precipitation and hydrometeor concentration, per exempe. Finally, simulations in which the droplets concentrations were specified showed better agreement with observations obtained during ABRACOS experiment (Anglo-Brazilian Amazonian Climate Observation Study), than simulations in which average diameter were specified.
13

Eletrificação dos sistemas precipitantes na região Amazônica: processos físicos e dinâmicos do desenvolvimento de tempestades / Electrification of precipitating systems over the Amazon: Physical and dynamical processes of thunderstorm development

Albrecht, Rachel Ifanger 13 June 2008 (has links)
Os sistemas convectivos da região Amazônica possuem características microfísicas peculiares, que variam de um caráter convectivo marítimo (estação chuvosa) a continental (estação de transição seca-chuvosa). Essas características modulam a eletrificação desses sistemas, porém ainda não se sabe quais são os processos dominantes que intensificam o número de descargas elétricas de uma estação para outra: efeito dos aerossóis, termodinâmico, grande-escala ou topografia? Para responder à essa pergunta, o objetivo deste trabalho foi identificar e quantificar a importância de cada um desses efeitos na eletrificação dos sistemas convectivos da Amazônia. A metodologia foi baseada em análises de dados observacionais do experimento de campo DRYTOWET e em um modelo numérico com parametrizações de transferências de cargas e descargas elétricas. A análise do ciclo anual das descargas elétricas do tipo nuvem-solo (CGs) mostrou que a atividade elétrica dos sistemas precipitantes da região sudoeste da Amazônia aumenta durante a transição da estação seca para a estação chuvosa (Agosto a Setembro), associada aos sistemas convectivos com maior desenvolvimento vertical que acontecem nesse período. Com o estabelecimento da estação chuvosa (Novembro a Março), o número de CGs diminui porém a atividade elétrica ainda se mantêm. A porcentagem desses totais de CGs que tinham polaridade positiva (+CGs) tem média de 12% durante todo o ano, aumentando drasticamente para até 25% em Setembro, durante a transição entre as estações secas e chuvosa. Esse aumento da %+CGs ocorreu simultaneamente ao aumento da poluição atmosférica provocada pela queima de biomassa das pastagens realizada pelos fazendeiros locais, que as preparam para a agricultura e pecuária durante o início das primeiras chuvas. Por outro lado, o aumento da %+CGs das tempestades também ocorreu preferencialmente sobre a área de pastagem do estado de Rondônia. Através da análise de dados de radar dos sistemas precipitantes que ocorreram durante o experimento DRYTOWET, foi constatado que as tempestades positivas (tempestades que produzem mais de 50% de +CGs em 50% de seu tempo de vida) se formaram em ambientes mais secos e com alturas do nível de convecção por levantamento (NCL, altura da base da nuvem) maiores do que as demais tempestades (tempestades negativas), durante todo o experimento mas com maiores diferenças durante o final da estação seca (Setembro-Outubro). Com altura da base da nuvem mais elevada, a espessura da camada quente (ECQ - base da nuvem até a isoterma de 0oC) diminui, aumentando assim a velocidade das correntes ascendentes através de um melhor processamento da energia potencial disponível para convecção (CAPE) devido a um menor entranhamento. O aumento da velocidade das correntes ascendentes dentro da nuvem resulta em tempestades mais profundas e mais intensas. O efeito do aumento do NCL é uma característica das regiões com vegetação de pastagem, onde a razão entre o calor sensível e latente na superfície é maior do que as áreas florestadas, aumentando a altura da camada limite planetária. As diferenças de concentração total e distribuição de tamanho dos aerossóis devido ao aumento da poluição durante a transição entre as estações seca e chuvosa não foram conclusivas quanto a um possível efeito na distribuição de hidrometeoros das tempestade positivas e negativas, uma vez que o ciclo diurno da concentração dos aerossóis acompanha o ciclo diurno da camada limite planetária, que também regula o efeito da ECQ. Simulações numéricas com um modelo 1D de nuvem, acoplado à parametrizações de transferências de cargas elétricas entre hidrometeoros e raios, mostraram que a estrutura termodinâmica da atmosfera foi a maior responsável pela eletrificação das tempestades simuladas, aumentando a velocidade das correntes ascendentes. O efeito do aumento do número de aerossóis, que inibe da fase quente da nuvem e conseqüentemente fortalece a da fase fria da nuvem fornecendo mais vapor e gotículas de nuvem para essa região, provocou a diminuição da quantidade de granizo nas tempestades simuladas e o aumento de partículas agregadas menores, como os flocos de neve e graupel, diminuindo a freqüência de raios. / Amazonian convective systems have unique microphysical characteristics, varying from a maritime convective behavior (rainy season) to a continental behavior (wet-dry transition season). These characteristics modulate the electrification of these systems, however it is still not well understood which are the dominant processes that intensify the frequency of lightning from one season to another: aerosol effect, thermodynamics, large-scale variability, landscape or topography? To answer this question, the objective of this study was to identify and quantify the importance of each one of these effects on the electrification of convective systems over the Amazon. The methodology was based on the analysis of observational data from the field experiment DRYTOWET and a numerical model with charge transfer parameterizations and lightning discharges. The cloud-to-ground (CG) lightning discharges annual cycle presented that the electrical activity of the southwestern Amazonian precipitating systems increased during the transition between the dry and wet seasons (August to September), in association with the convective systems deepening. With the establishment of the wet season (November to March), the number of CGs decreased but the electrical activity continued. The mean annual percentage of cloud-to-ground lightning of positive polarity (+CGs) was 12%, increasing drastically to 25% in September during the transition between the dry and wet seasons. This percentage of +CGs raise happened simultaneously with the increase in the atmospheric pollution due to the pasture biomass burning, held by local farmers to prepare the soil for agriculture and livestock during the begging of first rains. On the other hand, the increase in %+CGs also occurred preferentially over pasture areas of Rondonia state. Through the analysis of radar precipitating systems that occurred during the field campaign DRYTOWET, it was noted that positive thunderstorms (storms that produced more than 50% of +CGs over 50% of their life time) were initiated in drier and higher lift condensation levels (cloud base height) environments than other storms (negative thunderstorms) during all the field experiment, especially in the end of the dry season (September-October). A higher cloud base height is associated with a shallower warm cloud depth (cloud base height to the 0oC isotherm) and consequently less entrainment, increasing the updrafts due to a more efficient processing of the convective available potential energy (CAPE). This increase in updrafts inside the clouds results in deeper and stronger thunderstorms. The higher cloud base heights is a characteristic from pasture regions, where the ratio between sensible and latent heats at surface is greater than forested areas, which increases the top of the planetary boundary layer. The differences in the aerosol total concentration and size distribution, due to the increase in the atmospheric pollution during the transition between the dry and wet seasons, were inconclusive in a possible aerosol effect in the strength of positive and negative thunderstorms, once the aerosol concentration diurnal cycle follows the cycle of the planetary boundary layer, that also regulates the warm cloud depth effect. Numerical simulation of an 1D cloud model, coupled with charge transfer between the hydrometeors, showed that the thermodynamic structure was the main responsible feature for cloud electrification, increasing the updraft velocities. The pollution effect was masked in simulations, which inhibit the warm precipitation and consequently strength the the mixed and cold regions of the cloud, was responsible for an increase in the number of smaller aggregated particles, like snow flakes and graupel, decreasing the electrification and lightning frequency.
14

Eletrificação dos sistemas precipitantes na região Amazônica: processos físicos e dinâmicos do desenvolvimento de tempestades / Electrification of precipitating systems over the Amazon: Physical and dynamical processes of thunderstorm development

Rachel Ifanger Albrecht 13 June 2008 (has links)
Os sistemas convectivos da região Amazônica possuem características microfísicas peculiares, que variam de um caráter convectivo marítimo (estação chuvosa) a continental (estação de transição seca-chuvosa). Essas características modulam a eletrificação desses sistemas, porém ainda não se sabe quais são os processos dominantes que intensificam o número de descargas elétricas de uma estação para outra: efeito dos aerossóis, termodinâmico, grande-escala ou topografia? Para responder à essa pergunta, o objetivo deste trabalho foi identificar e quantificar a importância de cada um desses efeitos na eletrificação dos sistemas convectivos da Amazônia. A metodologia foi baseada em análises de dados observacionais do experimento de campo DRYTOWET e em um modelo numérico com parametrizações de transferências de cargas e descargas elétricas. A análise do ciclo anual das descargas elétricas do tipo nuvem-solo (CGs) mostrou que a atividade elétrica dos sistemas precipitantes da região sudoeste da Amazônia aumenta durante a transição da estação seca para a estação chuvosa (Agosto a Setembro), associada aos sistemas convectivos com maior desenvolvimento vertical que acontecem nesse período. Com o estabelecimento da estação chuvosa (Novembro a Março), o número de CGs diminui porém a atividade elétrica ainda se mantêm. A porcentagem desses totais de CGs que tinham polaridade positiva (+CGs) tem média de 12% durante todo o ano, aumentando drasticamente para até 25% em Setembro, durante a transição entre as estações secas e chuvosa. Esse aumento da %+CGs ocorreu simultaneamente ao aumento da poluição atmosférica provocada pela queima de biomassa das pastagens realizada pelos fazendeiros locais, que as preparam para a agricultura e pecuária durante o início das primeiras chuvas. Por outro lado, o aumento da %+CGs das tempestades também ocorreu preferencialmente sobre a área de pastagem do estado de Rondônia. Através da análise de dados de radar dos sistemas precipitantes que ocorreram durante o experimento DRYTOWET, foi constatado que as tempestades positivas (tempestades que produzem mais de 50% de +CGs em 50% de seu tempo de vida) se formaram em ambientes mais secos e com alturas do nível de convecção por levantamento (NCL, altura da base da nuvem) maiores do que as demais tempestades (tempestades negativas), durante todo o experimento mas com maiores diferenças durante o final da estação seca (Setembro-Outubro). Com altura da base da nuvem mais elevada, a espessura da camada quente (ECQ - base da nuvem até a isoterma de 0oC) diminui, aumentando assim a velocidade das correntes ascendentes através de um melhor processamento da energia potencial disponível para convecção (CAPE) devido a um menor entranhamento. O aumento da velocidade das correntes ascendentes dentro da nuvem resulta em tempestades mais profundas e mais intensas. O efeito do aumento do NCL é uma característica das regiões com vegetação de pastagem, onde a razão entre o calor sensível e latente na superfície é maior do que as áreas florestadas, aumentando a altura da camada limite planetária. As diferenças de concentração total e distribuição de tamanho dos aerossóis devido ao aumento da poluição durante a transição entre as estações seca e chuvosa não foram conclusivas quanto a um possível efeito na distribuição de hidrometeoros das tempestade positivas e negativas, uma vez que o ciclo diurno da concentração dos aerossóis acompanha o ciclo diurno da camada limite planetária, que também regula o efeito da ECQ. Simulações numéricas com um modelo 1D de nuvem, acoplado à parametrizações de transferências de cargas elétricas entre hidrometeoros e raios, mostraram que a estrutura termodinâmica da atmosfera foi a maior responsável pela eletrificação das tempestades simuladas, aumentando a velocidade das correntes ascendentes. O efeito do aumento do número de aerossóis, que inibe da fase quente da nuvem e conseqüentemente fortalece a da fase fria da nuvem fornecendo mais vapor e gotículas de nuvem para essa região, provocou a diminuição da quantidade de granizo nas tempestades simuladas e o aumento de partículas agregadas menores, como os flocos de neve e graupel, diminuindo a freqüência de raios. / Amazonian convective systems have unique microphysical characteristics, varying from a maritime convective behavior (rainy season) to a continental behavior (wet-dry transition season). These characteristics modulate the electrification of these systems, however it is still not well understood which are the dominant processes that intensify the frequency of lightning from one season to another: aerosol effect, thermodynamics, large-scale variability, landscape or topography? To answer this question, the objective of this study was to identify and quantify the importance of each one of these effects on the electrification of convective systems over the Amazon. The methodology was based on the analysis of observational data from the field experiment DRYTOWET and a numerical model with charge transfer parameterizations and lightning discharges. The cloud-to-ground (CG) lightning discharges annual cycle presented that the electrical activity of the southwestern Amazonian precipitating systems increased during the transition between the dry and wet seasons (August to September), in association with the convective systems deepening. With the establishment of the wet season (November to March), the number of CGs decreased but the electrical activity continued. The mean annual percentage of cloud-to-ground lightning of positive polarity (+CGs) was 12%, increasing drastically to 25% in September during the transition between the dry and wet seasons. This percentage of +CGs raise happened simultaneously with the increase in the atmospheric pollution due to the pasture biomass burning, held by local farmers to prepare the soil for agriculture and livestock during the begging of first rains. On the other hand, the increase in %+CGs also occurred preferentially over pasture areas of Rondonia state. Through the analysis of radar precipitating systems that occurred during the field campaign DRYTOWET, it was noted that positive thunderstorms (storms that produced more than 50% of +CGs over 50% of their life time) were initiated in drier and higher lift condensation levels (cloud base height) environments than other storms (negative thunderstorms) during all the field experiment, especially in the end of the dry season (September-October). A higher cloud base height is associated with a shallower warm cloud depth (cloud base height to the 0oC isotherm) and consequently less entrainment, increasing the updrafts due to a more efficient processing of the convective available potential energy (CAPE). This increase in updrafts inside the clouds results in deeper and stronger thunderstorms. The higher cloud base heights is a characteristic from pasture regions, where the ratio between sensible and latent heats at surface is greater than forested areas, which increases the top of the planetary boundary layer. The differences in the aerosol total concentration and size distribution, due to the increase in the atmospheric pollution during the transition between the dry and wet seasons, were inconclusive in a possible aerosol effect in the strength of positive and negative thunderstorms, once the aerosol concentration diurnal cycle follows the cycle of the planetary boundary layer, that also regulates the warm cloud depth effect. Numerical simulation of an 1D cloud model, coupled with charge transfer between the hydrometeors, showed that the thermodynamic structure was the main responsible feature for cloud electrification, increasing the updraft velocities. The pollution effect was masked in simulations, which inhibit the warm precipitation and consequently strength the the mixed and cold regions of the cloud, was responsible for an increase in the number of smaller aggregated particles, like snow flakes and graupel, decreasing the electrification and lightning frequency.
15

Microphysical Analysis and Modeling of Amazonic Deep Convection / Análise e Modelagem Microfísica da Convecção Profunda Amazônica

Basso, João Luiz Martins 16 July 2018 (has links)
Atmospheric moist convection is one of the main topics discussed on weather and climate. This study purpose is to understand why different and similar cloud microphysics parameterizations produce different patterns of precipitation at the ground through several numerical sensitivity tests with the WRF model in the simulation of a squall line case observed on the Amazon region. Four different bulk microphysics parameterizations (Lin, WSM6, Morrison, and Milbrandt) were tested, and the main results show that statistical errors do not change significantly among each other for the four numerical domains (from 27 km up to 1 km grids). The correlations between radar rainfall data and the simulated precipitation fields show the double-moment parameterization Morrison scheme was the one that displayed better results in the overall: While Morrison scheme show 0.6 correlation in the western box of the 1 km domain, WSM6 and Lin schemes show 0.39 and 0.05, respectively. Nevertheless, because this scheme presents good correlations with the radar rain rates, it also shows a fairly better system lifecycle, evolution, and propagation when compared to the satellite data. Although, the complexity that the way microphysics variables are treated in both one-moment and double-moment schemes in this case study do not highly affect the simulatios results, the tridimensional vertical cross-sections show that the Purdue Lin and Morrison schemes display more intense systems compared to WSM6 and Milbrandt schemes, which may be associated with the different treatments of the ice-phase microphysics. In the specific comparison between double-moment schemes, the ice quantities generated by both Morrison and Milbrandt schemes highly affected thesystem displacement and rainfall intensity. This also affects the vertical velocities intensity which, in its, turn, changes the size of the cold pools. Differences in ice quantities were responsible for distinct quantities of total precipitable water content, which is related with the verticallly integrated ice mixing ratio generated by Morrison. The system moves faster in Milbrandt scheme compared to Morrison because the scheme generated more graupel quantities, which is smaller in size than hail, and it evaporates easier in the processes inside the cloud due to its size. This fact also changed the more intense cold pools intensity for Milbrandt scheme compared to Morrison. / A convecção atmosférica é um dos principais tópicos discutidos no tempo e clima. O objetivo deste estudo é entender por que diferentes e semelhantes parametrizações de microfísica de nuvens produzem diferentes padrões de precipitação no solo através de vários testes numéricos de sensibilidade com o modelo WRF na simulação de um caso de linha de instabilidade observado na região amazônica. Quatro diferentes parametrizações microfísicas de tipo bulk (Lin, WSM6, Morrison e Milbrandt) foram testadas, e os principais resultados mostram que os erros estatísticos não se alteram significativamente entre si para os quatro domínios numéricos (da grade de 27 km até a de 1 km). As correlações entre dados pluviométricos de radar e os campos de precipitação simulados mostram que o esquema Morrison de parametrização de duplo momento foi o que apresentou melhores resultados, no geral: enquanto o esquema de Morrison mostra correlação 0,6 na caixa oeste do domínio de 1 km, os esquemas WSM6 e Lin mostram 0,39 e 0,05, respectivamente. No entanto, como esse esquema apresenta boas correlações com as taxas de chuva do radar, ele também mostra um ciclo de vida, evolução e propagação do sistema relativamente melhores quando comparado aos dados de satélite. Embora a complexidade com que as variáveis microfísicas são tratadas nos esquemas de um momento e de duplo momento neste estudo de caso não afetam muito os resultados simulados, as seções transversais verticais tridimensionais mostram que os esquemas de Purdue Lin e Morrison exibem mais intensos em comparação com os esquemas WSM6 e Milbrandt, que podem estar associados aos diferentes tratamentos da microfísica da fase de gelo. Na comparação específica entre esquemas de momento duplo, as quantidades de gelo geradas pelos esquemas de Morrison e Milbrandt afetaram muito o deslocamento do sistema e a intensidade da chuva. Isso também afeta a intensidade das velocidades verticais que, por sua vez, altera o tamanho das piscinas frias. As diferençaas nas quantidades de gelo foram responsáveis por quantidades distintas de conteúdo total de água, que está relacionado com a razão de mistura de gelo verticalmente integrada gerada por Morrison. O sistema se move mais rápido no esquema de Milbrandt comparado a Morrison porque o esquema gerou mais quantidades de graupel, que é menor em tamanho do que o granizo, e evapora mais facilmente nos processos dentro da nuvem devido ao seu tamanho. Este fato também mudou a intensidade das piscinas frias mais intensas, porém menores em extensão horizontal, para o esquema Milbrandt em comparação com Morrison.
16

Análise de propriedades de nuvens em função da profundidade óptica do aerossol a partir de produtos derivados pelo MODIS da região amazônica durante a estação seca / Analysis of the cloud properties as a function of the aerosol optical depth from MODIS products in the Amazon region during the dry season

Rocha, Vinicius Roggerio da 01 December 2011 (has links)
Os efeitos da interação entre aerossóis e nuvens foram estudados neste trabalho através da análise das propriedades ópticas de nuvens em função da profundidade óptica do aerossol (AOD). A região de trabalho foi a Amazônia, particularmente durante a estação seca e na transição entre a estação seca e a chuvosa, quando as queimadas lançam grande quantidade de partículas na atmosfera. Foram utilizados produtos derivados do MODIS (Moderate Resolution Imaging Spectroradiometer), sendo dois artigos utilizados como referência (Yu et al., 2007 e Koren et al., 2008). Observou-se comportamento de correlação entre fração de cobertura de nuvens e AOD conforme previsto em Koren et al. (2008) para outros anos estudados (2002 a 2008), nas estações seca e de transição entre seca e úmida, e em seis áreas menores de estudo de diferentes regiões da Amazônia, utilizando resultados das passagens da manhã (satélite Terra) e da tarde (satélite Aqua). Essas análises também foram realizadas restringindo-se os dados a situações atmosféricas semelhantes, conforme conteúdo de vapor dágua e instabilidade atmosférica, sendo observado o efeito microfísico através de médias, mas o radiativo não foi observado. / The effects of the interaction between aerosols and clouds are studied in this work by analyzing the optical properties of clouds as a function of the aerosol optical depth (AOD). The studied area is the Amazon region, particularly during the dry season and the transition between the dry to wet season, when fires release large amounts of particles in the atmosphere. MODIS (Moderate Resolution Imaging Spectroradiometer) products are used and two papers are used as reference (Yu et al., 2007 and Koren et al., 2008). As observed by Koren et al. (2008), correlation between cloud cover fraction and AOD was observed in this study, for a larger database, including years 2002 to 2008, both during the dry seasons and the transition between dry to wet. Six smaller areas in the Amazon were also investigated, using results from morning (Terra satellite) and afternoon (Aqua satellite) overpasses. These tests were also conducted by restricting the data according to atmospheric conditions such as water vapor content intervals and atmospheric instability. In this case, only the microphysical effect was observed, but not the radiative.
17

Estudo experimental de oscilações em um orbitron sujeito a um campo elétrico R.F. externo

José Celso Thomaz Júnior 01 January 1989 (has links)
No Orbitron, elétrons de um pequeno filamento aquecido são injetados entre dois cilindros coaxiais com energia e modelo angular tal que eles orbitam ao redor do cilindro central (uma d.d.p. é aplicada entre os cilindros). Com a superposição de um potencial r.f. ao potencial logarítmico presente no Orbitron, picos de corrente negativa no catodo (cilindro externo) são observados para frequências bem definidas, indicando a ejeção dos elétrons de sua órbita original, presumivelmente devido à um alargamento da órbita com aumento do apogeu até sua coleta no cilindro externo. O comportamento das frequências observadas com vários parâmetros característicos so Orbitron foram estudados e um modelo teório é proposto.
18

Uma nova visão sobre a periferia das Nuvens de Magalhães

Pieres, Adriano January 2017 (has links)
Nossa amostra de trabalho consistiu das cercanias das Nuvens de Magalhães dentro da area amostrada pelo Dark Energy Survey. Nos concentramos na amostra de aglomerados da Grande Nuvem de Magalhães e na descoberta de uma sobredensidade estelar associada a Pequena Nuvem de Magalhães, sobre as quais faremos aqui uma breve descrição, baseada nos resumos já publicados. A Grande Nuvem de Magalhães possui um sistema rico e diversificado de aglomerados estelares, cujas idades, abundâncias químicas e posições oferecem informação a respeito do histórico de formação estelar desta galáxia. Nós usamos as imagens dos dados de verificação científica do Dark Energy Survey para aumentar o censo de aglomerados conhecidos na região externa da Grande Nuvem de Magalhães e para determinar os parâmetros físicos de uma grande número destes objetos usando uma amostra homogênea, tanto fotom elétrica quanto espacialmente. Nossa amostra contém 255 aglomerados identificados visualmente, dos quais 109 não estão listados em nenhum catálogo prévio. Nós quantificamos o efeito de adensamento estelar para a amostra produzida pela equipe de gerenciamento dos dados do Dark Energy Survey e concluímos que a completeza da amostra estelar e < 10% no centro de aglomerados típicos da Grande Nuvem de Magalhães. Desenvolvemos então um arranjo de tarefas para amostrar e medir as magnitudes e posições das estrelas nos candidatos a aglomerados da Grande Nuvem de Magalhães utilizando o conjunto de pacotes daophot. Tamb em implementamos um método de máxima probabilidade para ajustar perfis de densidade individuais, bem como diagramas cor-magnitude. Para 117 aglomerados (de um total de 255) dos candidatos, sendo 28 aglomerados até então não catalogados, obtivemos idades, metalicidades, m odulo de distância e parâmetros estruturais confiáveis, confirmando sua natureza de sistemas físicos. The distribution of cluster metallicities shows a radial dependence, with no clusters more metal-rich than [Fe/H] ' 0:7 beyond 8 kpc from the center of that galaxy. The age distribution has two peaks at ' 1.2 Gyr and ' 2.7 Gyr. The age-metallicity relation shows that even with an external sample, there is a global agreement with other studies that sampled more central regions of the Large Magellanic Cloud. In addition, this age-metallicity relation is well described as bounded by the analytical model from Pagel & Tautvaisiene (1998) and the empirical model from Harris & Zaritsky (2009). But neither of them describes accurately the clusters set. We also report here the discovery of a stellar over-density 8 north of the center of the Small Magellanic Cloud, baptized as SMCNOD (Small Magellanic Cloud Northern Over-Density), using data from the rst two years of the Dark Energy Survey (DES) and the rst year of the MAGellanic SatelLITEs Survey (MagLiteS). The SMCNOD is indistinguishable in age, metallicity and distance from the nearby SMC stars, being primarly composed of intermediate-age stars (6 Gyr, Z=0.001), with a small fraction of young stars (1 Gyr, Z=0.01). The SMCNOD has an elongated shape with an ellipticity = 0:6 and a size of 6x2 deg. It has an absolute magnitude of MV = 7:7, rh = 2:1 kpc, and V (r < rh) = 31.2 mag arcsec2. We estimate a stellar mass of 105 M , following a Kroupa mass function. The SMCNOD was probably removed from the SMC disk by tidal stripping, since it is located near the head of the Magellanic Stream, and the literature indicates likely recent LMC-SMC encounters. This scenario is supported by the lack of signi cant HI gas. Other potential scenarios for the SMCNOD origin are a transient over-density within the Small Magellanic Cloud tidal radius or a primordial SMC satellite in advanced stage of disruption. Estimamos uma massa estelar de 105 massas solares, seguindo uma função de massa inicial de Kroupa. A SMCNOD foi provavelmente removida do disco da Pequena Nuvem de Magalhães via tidal stripping, pois e localizada próximo da extremidade da Corrente de Magalhães (Magellanic Stream) e, segundo a literatura, houve recentes encontros entre a LMC e a SMC. Este cenário e apoiado pela significante falta de Hidrogênio neutro. Outros cenários potenciais para a origem da SMCNOD são: uma sobredensidade transitória dentro do raio de mar e ou uma satélite primordial em estado avançado de ruptura. / Our working sample comprised the outskirts of the Magellanic Clouds encompassed by the Dark Energy Survey. We focused in the star cluster system of the Large Magellanic Cloud and on the discovery of a stellar over-density associated to the Small Magellanic Cloud, which we will brie y describe here, based on already published abstracts. The Large Magellanic Cloud harbors a rich and diverse system of star clusters, whose ages, chemical abundances, and positions provide information about the Large Magellanic Cloud history of star formation. We use Science Veri cation imaging data from the Dark Energy Survey to increase the census of known star clusters in the outer Large Magellanic Cloud and to derive physical parameters for a large sample of such objects using a spatially and photometrically homogeneous data set. Our sample contains 255 visually identi ed cluster candidates, of which 109 were not listed in any previous catalog. We quantify the crowding e ect for the stellar sample produced by the Dark Energy Survey Data Management pipeline and conclude that the stellar completeness is < 10% inside typical Large Magellanic cluster cores. We therefore develop a pipeline to sample and measure stellar magnitudes and positions around the cluster candidates using daophot. We also implement a maximumlikelihood method to t individual density pro les and colour-magnitude diagrams. For 117 (from a total of 255) of the cluster candidates (28 uncatalogued clusters), we obtain reliable ages, metallicities, distance moduli and structural parameters, con rming their nature as physical systems.
19

Análise de propriedades de nuvens em função da profundidade óptica do aerossol a partir de produtos derivados pelo MODIS da região amazônica durante a estação seca / Analysis of the cloud properties as a function of the aerosol optical depth from MODIS products in the Amazon region during the dry season

Vinicius Roggerio da Rocha 01 December 2011 (has links)
Os efeitos da interação entre aerossóis e nuvens foram estudados neste trabalho através da análise das propriedades ópticas de nuvens em função da profundidade óptica do aerossol (AOD). A região de trabalho foi a Amazônia, particularmente durante a estação seca e na transição entre a estação seca e a chuvosa, quando as queimadas lançam grande quantidade de partículas na atmosfera. Foram utilizados produtos derivados do MODIS (Moderate Resolution Imaging Spectroradiometer), sendo dois artigos utilizados como referência (Yu et al., 2007 e Koren et al., 2008). Observou-se comportamento de correlação entre fração de cobertura de nuvens e AOD conforme previsto em Koren et al. (2008) para outros anos estudados (2002 a 2008), nas estações seca e de transição entre seca e úmida, e em seis áreas menores de estudo de diferentes regiões da Amazônia, utilizando resultados das passagens da manhã (satélite Terra) e da tarde (satélite Aqua). Essas análises também foram realizadas restringindo-se os dados a situações atmosféricas semelhantes, conforme conteúdo de vapor dágua e instabilidade atmosférica, sendo observado o efeito microfísico através de médias, mas o radiativo não foi observado. / The effects of the interaction between aerosols and clouds are studied in this work by analyzing the optical properties of clouds as a function of the aerosol optical depth (AOD). The studied area is the Amazon region, particularly during the dry season and the transition between the dry to wet season, when fires release large amounts of particles in the atmosphere. MODIS (Moderate Resolution Imaging Spectroradiometer) products are used and two papers are used as reference (Yu et al., 2007 and Koren et al., 2008). As observed by Koren et al. (2008), correlation between cloud cover fraction and AOD was observed in this study, for a larger database, including years 2002 to 2008, both during the dry seasons and the transition between dry to wet. Six smaller areas in the Amazon were also investigated, using results from morning (Terra satellite) and afternoon (Aqua satellite) overpasses. These tests were also conducted by restricting the data according to atmospheric conditions such as water vapor content intervals and atmospheric instability. In this case, only the microphysical effect was observed, but not the radiative.
20

Estudo de aglomerados estelares das nuvens de magalhães usando fotometria CCD na banda V

Carvalho, Luziane Oliveira 02 June 2005 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In this work we present CCD photometry in the V band for 13 star clusters in the Magellanic Clouds (LI0, L54, L59, L85, L96, NGC 1818, NGC 1866, NGC 1868, NGC 1978, NGC 2157, NGC 2213, NGC 2214, Hll). Photometric calibration has been done using standard stars from the E-regions (Graham, 1982) and the least square system GAUSSFIT (Jefferys et aI.,1988). The mean error obtained was less than 0.01 mag at a 66% confidence leveI. Cluster centers have been determinated using an implementation of the Djorgovski autocorrelation algorithm (1988) with a I" mean error. CCD frames have/ been cleaned of stellar contamination using the DAOPHOT package from IRAF, where probable non-clusters stars have been removed. We made the surface photometry in the V band and used the model considered for Elson, Fall and Freeman (1987) to fit the surface brightness curves. The clusters structural parameters, obtained from fitted brightness profiles, have been used to obtain luminosity and mass estimation for all clusters. / Nesse trabalho apresentamos a fotometria CCD na banda V de 13 aglomerados estelares das Nuvens de Magalhães (LI0, L54, L59, L85, L96, NGC 1818, NGC 1866, NGC 1868, NGC 1978, NGC 2157, NGC 2213, NGC 2214, Hll). A calibração fotométrica foi feita utilizando estrelas padrão de regiões-E (Graham, 1982) e o sistema de ajuste por mínimos quadrados GaussFit (Jefferys et al.,1988). O erro médio obtido é menor que 0.01 mag para um nível de confiança de 66%. O centro dos aglomerados foi determinado utilizando-se uma implementação do algoritmo de autocorrelação de Djorgovski (1988) com um erro médio de I". As imagens foram limpas de contaminação estelar utilizando o pacote DAOPHOT do IRAF, onde estrelas provavelmente não pertencentes aos aglomerados foram subtraídas. Fizemos a fotometria superficial na banda V e utilizamos o modelo proposto por Elson, Fall e Freeman (Elson et aI., 1987) para ajustar as curvas de brilho superficial. Os parâmetros estruturais dos aglomerados, obtidos a partir do ajuste dos dados de brilho superficial, foram utilizados para fazer uma estimativa da luminosidade e da massa de cada aglomerado.

Page generated in 0.056 seconds