• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação comparativa da efetividade das placas oclusais confeccionadas em relação central ou máxima intercuspidação em pacientes com DTM /

Hamata, Marcelo Matida. January 2006 (has links)
Orientador: Paulo Renato Junqueira Zuim / Banca: Alício Rosalino Garcia / Banca: Osvaldo Luiz Bezzon / Resumo: A posição de relação central (RC) para a confecção de placas oclusais é muito discutível. Dessa forma, quando existe estabilidade oclusal, a máxima intercuspidação (MI) poderia ser utilizada como ponto de referência, eliminando a necessidade de registro interoclusal. O presente trabalho tem por objetivo comparar a efetividade de placas oclusais confeccionadas a partir de modelos articulados nessas duas posições. Para isso, 20 pacientes com desordens temporomandibulares (DTM) e dor de origem muscular foram divididos em dois grupos de 10 e tratados com placas confeccionadas nas posições de MI ou RC. Estes foram avaliados por meio de exame clínico, eletrognatográfico e eletromiográfico, antes e após três meses de terapia. Os resultados permitiram verificar que os dois tipos de placa atuaram de forma semelhante. Entretanto, a confecção de placas oclusais a partir da MI mostrou ser uma técnica mais fácil e menos onerosa do que a de RC. / Abstract: Centric relation (CR) position to fabricate occlusal splints is very discussable. In this way, when there is occlusal stability, intercuspal position (IP) could be used as a reference point, eliminating the interocculsal record necessity. The purpose of the present study was to compare the effectiveness of occlusal splints fabricated from models articulated in these two positions. Twenty patients with temporomandibular disorders (TMD) of myogenous origin were divided in two groups with 10 each, which were treated with splints fabricated in the CR or IP. The patients were evaluated by clinical, electrognathographic and electromyographic examinations, before and tree months after the therapy. Results showed similar levels of effectiveness of both kinds of splint. However, the fabrication of the splints from IP technique is easier and less onerous than the CR. / Mestre
2

Avaliação da atividade elétrica e limiar de dor à pressão dos músculos masseter e temporal anterior com placas de diferentes espessuras /

Ribeiro, Adriana Barbosa. January 2010 (has links)
Resumo: A hiperatividade muscular associada ou não a alterações oclusais pode ser um fator desencadeante das desordens temporomandibulares (DTMs). Qualquer alteração nas estruturas do aparelho estomatognático pode promover um desequilíbrio funcional da mandíbula. A algometria por pressão bem como a eletromiografia tem sido utilizadas como métodos de diagnóstico e controle da evolução terapêutica dos músculos da mastigação. Diversos tratamentos buscam diminuir os sintomas característicos das DTMs pelo restabelecimento do equilíbrio, dentre os quais vale citar a terapia oclusal por meio da placa interoclusal. Uma das dificuldades durante a confecção dos dispositivos interoclusais é determinar a sua espessura. Este critério pode influenciar a eficiência, o desempenho da função de relaxamento e o tratamento da dor muscular. O objetivo deste estudo foi avaliar o efeito da espessura da placa, da consistência do alimento e do gênero, na atividade elétrica e no limiar de dor à pressão (LDP) nos músculos masseter e temporal anterior. Para verificar o efeito de diferentes espessuras de placas interoclusais foram selecionados 20 pacientes assintomáticos que utilizaram placas com espessuras 3 e 6 mm. Foram obtidas médias a partir dos valores encontrados em cada paciente, sendo avaliados lados de trabalho e não-trabalho, por meio de registros da atividade elétrica durante a mastigação de dois tipos diferentes de látex e limiar de sensibilidade dos músculos masseter e temporal anterior. Após sua obtenção, os dados foram tabulados e submetidos à análise estatística, a um nível de 5% de significância (p<0,05). Pode-se concluir que as placas de diferentes espessuras (tratamentos) e o gênero não alteraram a atividade elétrica, porém a maior consistência do alimento proporcionou atividades elétricas mais elevadas. O limiar de dor à pressão... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The muscular hyperactivity with or without occlusal changes can is a trigger of temporomandibular disorders (TMD). Any change in the structures of the stomatognathic system can promote a functional imbalance of the jaw. The algometry pressure and electromyography has been used as methods of diagnosis and therapy control of the evolution of the muscles of mastication. Several treatments seek to reduce the symptoms characteristic of TMD by restoring the occlusal, among which worth mentioning the occlusal therapy through the plate interocclusal. One of the difficulties during the construction of the splint device is to determine its thickness. This criterion can influence the efficiency, performance of the function of relaxation and treatment of muscle pain provided by interocclusal devices. The objective of this study was to evaluate the thickness of the plate, consistency of the food and gender, in the electric activity and threshold of pain to the pressure (LDP) in the muscles to masseter and anterior temporal. patients in whom signs were established with thickness 3 and 6 mm. Medium were obtained from each side to work and working from records of electrical activity during mastication of two latex sensitivity threshold of the masseter and anterior temporal of all patients. After obtaining the data, the data were tabulated and subjected to statistical analysis, a 5% level of significance (p <0.05). It It was observed that the plates of different thicknesses (treatments) and the gender had not modified the electric activity, however the biggest consistency of the food provided higher electric activities. The threshold of pain to the pressure was modified with the use of the plates of different thicknesses only for the temporal muscle of the work side, as well as was superior for the men in all the muscles evaluated, however the mastication activity did not influence in the LDP / Orientador: Paulo Renato Junqueira Zuim / Coorientador: Alicio Rosalino Garcia / Banca: Karina HelgaTúrcio de Carvalho / Banca: Vinícius Pedrazzi / Mestre
3

O efeito da espessura da placa interoclusal sobre a atividade elétrica e a temperatura dos músculos temporal anterior e masseter durante o repouso e o apertamento dental /

Pita, Murillo Sucena. January 2009 (has links)
Resumo: O aumento da atividade muscular, induzido pelo apertamento dental, pode ser considerado como fator etiológico ou agravante das desordens temporomandibulares (DTMs), e essa atividade tem sido explorada de maneira direta através da eletromiografia e indiretamente pela variação da temperatura superficial cutânea sobre os músculos mastigatórios. As placas oclusais são os métodos não-invasivos mais utilizados para o tratamento das DTMs, particularmente as que afetam os músculos mastigatórios, objetivando a redução dessa hiperatividade muscular. Entretanto, há controvérsias em relação ao estabelecimento da sua espessura ideal. O objetivo do presente estudo, foi determinar o efeito da espessura de placas miorrelaxantes (3 mm e 6 mm) sobre a atividade elétrica e a temperatura dos músculos temporal anterior e masseter durante o repouso e o apertamento dental, considerando-se a condição assintomática de 20 indivíduos (10 homens e 10 mulheres) selecionados através do questionário Research Diagnostic Criteria (RDC). Os registros eletromiográficos foram realizados por meio do software "Bio EMG" (Biopack - System Bio-Research) e a temperatura das superfícies musculares realizada com o auxílio de um termômetro digital infravermelho (ICEL TD-971), com as respectivas medidas em microvolts ([V) e graus Celsius (ºC). Os resultados obtidos, analisados estatisticamente em um nível de 5% de significância (p<0,05), evidenciaram o aumento da atividade elétrica e a diminuição da temperatura dos músculos temporal anterior e masseter durante o apertamento dental em relação ao repouso. Entretanto não houve diferenças estatisticamente significativas em relação à atividade elétrica e a temperatura dos músculos mastigatórios entre as condições com e sem placa, entre o gênero masculino e feminino, bem como entre as espessuras de placas analisadas. / Abstract: The increased of muscles activity, induced for dental clenching can be considered as causing or aggravating factor of temporomandibular disorders (TMD), and this activity has been exploited in a straightforward manner using electromyography and indirectly by the variation in skin surface temperature on the masticatory muscles. The occlusal splints are non-invasive methods more utilized for the treatment of TMD, particularly those from the masticatory muscles, aiming at the reduction of muscle hyperactivity. However, there are controversies regarding the establishment of their ideal thickness. The aim of this study was to determine the effect of thickness of the occlusal splints (3 mm and 6 mm) on the electrical activity and temperature of the anterior temporal and masseter muscles during dental clenching and resting, considering the asymptomatic condition of 20 individuals (10 males and 10 females) selected through the questionnaire Research Diagnostic Criteria (RDC). The electromyographic data were analyzed by the software Bio EMG (Biopack - Bio-Research System) and the surface temperatures of muscle carried out with the aid of a digital infrared thermometer (ICEL TD-971) and the corresponding measures in microvolts ([V) and degrees Celsius (ºC). The results, analyzed in a 5% of significance (p <0.05), showed increased electrical activity and lowering the temperature of the anterior temporal and masseter muscles during dental clenching in relation to the rest. However there were no statistically significant differences in relation to temperature and electrical activity of masticatory muscles between conditions with and without splints, between males and females, and between the thicknesses of occlusal splints analyzed. / Orientador: Paulo Rentato Junqueira Zuim / Coorientador: Alicio Rosalino Garcia / Banca: Karina Helga Turcio de Carvalho / Banca: Osvaldo Luiz Bezzon / Mestre

Page generated in 0.0679 seconds