• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 442
  • 120
  • 109
  • 55
  • 43
  • 9
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • Tagged with
  • 969
  • 969
  • 148
  • 125
  • 119
  • 114
  • 100
  • 91
  • 79
  • 79
  • 72
  • 66
  • 63
  • 60
  • 55
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
531

Crescimento e caracterização de fibras monocristalinas de fluoretos do tipo LiYsub(1-x)TRsub(x)Fsub(4) (TR=terras raras)

ESPIRITO SANTO, ANA M. do 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:50:58Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:48Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Neste trabalho, foram estudados os processos de crescimento e caracterização de fibras monocristalinas de LiF e de LiYF4 (YLF) puras e dopadas com érbio (Er) ou neodímio (Nd) para aplicações ópticas. O crescimento destas fibras foi efetuado pelo método de micro-pulling-down (µ-PD) e o uso desta técnica é inédito para a obtenção de fibras monocristalinas destes fluoretos. Para tal finalidade, foi inicialmente construído no IPEN, um protótipo do sistema de µ-PD no modo resistivo para a compreensão dos parâmetros experimentais. Posteriormente, um equipamento comercial foi instalado e especialmente adaptado para o puxamento de fibras de fluoretos. Foram obtidas fibras monocristalinas de LiF, com boa qualidade óptica e estrutural e dimensões uniformes: diâmetros entre 0,5 e 1 mm e comprimentos de até 15 cm. A avaliação para o uso destas fibras como meio laser ativo indicou que suas propriedades ópticas são semelhantes às observadas em cristais volumétricos. Foi investigada a influência da geometria do capilar e cadinho, da atmosfera de crescimento e da composição de partida na estabilidade do processo de crescimento de fibras de YLF pelo método de µ-PD. Este material é muito sensível às contaminações procedentes da atmosfera de crescimento e a formação da fase estequiométrica, durante o crescimento da fibra, depende fortemente da atmosfera, da velocidade de puxamento e da composição de partida. Foram obtidas, de forma reprodutível, fibras puras com diâmetro uniforme (0,5 à 0,8 mm) e longo comprimento da fase estequiométrica (até 60 mm). Fibras de YLF com dopagens nominais de 10 mol% e 40 mol% de Er e com 1,7 mol% de Nd foram também obtidas com sucesso. As fibras de YLF:Er são homogêneas e livres de trincas, com distribuição regular de dopante e concentração próxima ao valor nominal. O perfil de distribuição de Nd na fibra de YLF:Nd é diferenciado. O valor do coeficiente de distribuição efetivo k foi estimado em 0,58; valor este superior aos valores encontrados para cristais volumétricos de YLF:Nd. A investigação das propriedades ópticas de absorção e emissão evidenciou características semelhantes às observadas em cristais volumétricos dopados com Nd, permitindo considerar as fibras de YLF:Nd com potencial para uso como meio laser ativo em dispositivos ópticos compactos com bombeamento por diodo. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP / FAPESP:01/07337-3
532

Desenvolvimento de biofilme formado por Candida albicans in vitro para estudo da terapia fotodinamica / Candida albicans biofilm development in vitro for photodynamic therapy study

SUZUKI, LUIS C. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:57Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:21Z (GMT). No. of bitstreams: 0 / A terapia fotodinâmica, do inglês photodynamic therapy (PDT) é uma fototerapia baseada na utilização de um fotossensibilizador (FS) na presença da luz em baixa intensidade em comprimento de onda ressonante à absorção do FS e que podem sensibilizar sistemas biológicos, gerando espécies reativas de oxigênio. Estudos mostram que a PDT apresenta um efeito letal em Candida albicans. O biofilme formado por C. albicans é a causa mais freqüente de infecções associadas a cateteres, possuindo uma comprovada resistência a antifúngicos, sendo que a remoção do cateter colonizado é quase sempre necessária. No entanto, poucos trabalhos na literatura relatam o comportamento e a resposta de C. albicans organizado em biofilme frente à PDT. Os objetivos deste trabalho foram desenvolver uma metodologia para formação in vitro de biofilme de C. albicans, verificar a sensibilidade do biofilme de C. albicans frente à terapia fotodinâmica antimicrobiana utilizando como FS o azul de metileno (AM) e a hipocrelina B:La+3 e analisar o biofilme através da Tomografia de Coerência Óptica (OCT) antes e depois da PDT. Para a formação do biofilme, foram confeccionados discos de silicone elastomérico oriundos de cateteres. Os fotossensibilizadores foram diluídos em solução de PBS, sendo que o AM teve duas concentrações diferentes testadas no biofilme: 100M e 1mM e a HBLa+3 somente uma de 10M. A irradiação de ambos os corantes com os microrganismos foi feita através de dois LEDs diferentes, um vermelho com = 630nm ± 20nm e outro azul com = 460nm ± 30nm. Foi realizada uma curva de fração de sobrevivência em função do tempo de irradiação de cada amostra com biofilme e de suspensão do microrganismo em formato de leveduras para verificar a susceptibilidade destes frente à PDT. As leveduras apresentaram 100% de redução em ambos os fotossensibilizadores, porém em tempos de irradiação diferentes (30s para a HBLa+3 e 6 min para o AM na concentração de 100M). Quando a terapia foi aplicada em biofilme, o AM em 100M não apresentou nenhuma redução significativa, enquanto que em concentração de 1mM houve redução de 100% após 6 min de irradiação. Já a HBLa+3 mostrou pouca redução em biofilme na concentração de 10M (menos de 1 log de redução. Concluímos que o microrganismo C. albicans se organizou em biofilme padronizado nos discos elastoméricos oriundos de cateteres e através do OCT, o biofilme medido apresentou 110m de espessura, informando uma mudança óptica ao ser submetido pela PDT com o AM 1mM. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
533

Avaliacao dos efeitos promovidos pela radiacao azul na remineralizacao do esmalte dentario in vitro / Effects of blue light irradiation on dental enamel remineralization in vitro

KATO, ILKA T. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:49Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:45Z (GMT). No. of bitstreams: 0 / Este trabalho foi desenvolvido com o objetivo de avaliar os efeitos da luz azul na remineralização do esmalte. Adicionalmente foi desenvolvida uma metodologia de análise para a avaliação de alterações minerais do esmalte dental por meio da tomografia por coerência óptica. Lesões foram formadas em amostras de esmalte dental bovino por meio da imersão em solução tampão de acetato subsaturado (2 mL/mm2 e 6,25 mL/mm2) por 32 h. As amostras foram irradiadas com um LED azul com emissão em 455±20 nm, potência de 110 mW, irradiância de 1,4 W/cm2, tempo de irradiação de 10 s e exposição radiante de 13,8 J/cm2. Posteriormente, as amostras foram submetidas à ciclagem de pH durante oito dias à 37 oC para induzir a remineralização. A avaliação do conteúdo mineral foi realizada por meio do teste de dureza seccional e por tomografia por coerência óptica (OCT). Na avaliação por dureza observou-se que as amostras do grupo irradiado apresentaram menor conteúdo mineral que as amostras do grupo não irradiado. A diferença entre os grupos foi mais evidente nas amostras submetidas à formação de lesão em maior volume de solução desmineralizadora. Por meio da técnica de OCT foram observadas diferenças significativas entre o sinal do esmalte hígido e desmineralizado. Após a remineralização, as amostras irradiadas apresentaram menor conteúdo mineral que as não irradiadas; porém, não foram observadas diferenças significativas entre os grupos. Com base nos resultados deste estudo, pode-se concluir que a irradiação com luz azul (l=455nm) promoveu a inibição da remineralização do esmalte dental. A metodologia empregada nas análises por OCT permitiu a avaliação quantitativa da perda mineral no esmalte; porém, este resultado não foi alcançado na avaliação da remineralização. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
534

Estudo do perfil vertical de aerossóis na troposfera utilizando a técnica de LIDAR

SOUZA, RENATA F. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:25:48Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:33Z (GMT). No. of bitstreams: 1 11315.pdf: 4284842 bytes, checksum: 94ad34802b7652ff6ef2b3584c12f794 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP / FAPESP:01/07304-8
535

Estudos opticos de defeitos produzidos por irradiacao em monocristais de LiF:Mg

RANIERI, IZILDA M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:29:14Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:03:50Z (GMT). No. of bitstreams: 1 01098.pdf: 1845667 bytes, checksum: 1511b170df22e6ca5456a95e441d26c5 (MD5) / Dissertacao (Mestrado) / IEA/D / Instituto de Energia Atomica - IEA
536

Caracterizacao espectroscopica de complexos hipocrelina B: lantanideos para uso em terapia fotodinamica / Spectroscopic characterization of hypocrellin B: lanthanide complexes for use in photodynamic therapy

TOFFOLI, DANIEL J. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:20Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:04:18Z (GMT). No. of bitstreams: 0 / Um estudo das propriedades ópticas do cromóforo hipocrelina B (HB) e de seus complexos com os íons lantânio (La3+), európio (Eu3+) e térbio (Tb3+) em soluções em etanol foi realizado. Tal pigmento enquadra-se como um promissor fotossensibilizador de segunda geração dadas suas ótimas propriedades, tais como rápido metabolismo in vivo e principalmente elevado rendimento quântico de geração de oxigênio singleto (FD). O presente trabalho foi desenvolvido em duas etapas: a primeira consistiu do estudo espectroscópico dos complexos de hipocrelina B (HB) com os íons lantanídeos (Ln3+), e a segunda, de testes de PDT in vitro em cultura do fungo Candida albicans. Na primeira etapa do trabalho, a melhor razão molar entre HB e Ln3+ foi verificada através do monitoramento do pico de absorção em maior comprimento de onda de cada um dos complexos. O maior deslocamento do pico de absorção da HB (de 589 nm para 614 nm) foi notado para os complexos com razão de 1 mol de HB para 2 mols de íon lantanídeo. Observou-se que a emissão da HB e de seus complexos ocorre desde cerca de 600 nm até 750 nm. Foi possível, com base nos espectros de absorção e de emissão, calcular os valores de níveis de energia da molécula e de seus complexos. Todos os fotossensibilizadores apresentaram como menor nível de energia valor superior a 0,98 eV, o que é um indício de sua capacidade de geração de oxigênio singleto. Foram determinadas as constantes de dimerização das amostras, de maneira a identificar sua tendência à formação de dímeros ou agregados de ordem superior, e os valores obtidos para a HB e seus complexos com lantânio, európio e térbio foram, respectivamente, de 4,7.104, 3,6.105, 2,1.105 e 1,0.105 M-1. Todas as amostras mostraram-se estáveis perante a ação de luz de 532 nm de até 400 mW/cm2 de intensidade pelo período de uma hora de irradiação. As capacidades de geração de oxigênio singleto das amostras foram determinadas tanto através do método espectroscópico direto (detecção da emissão do oxigênio singleto em torno de 1270 nm) quanto do método químico indireto (variações na absorção em 440 nm do composto RNO). Notou-se que para a HB o método direto indicou haver geração de oxigênio singleto, e o método químico revelou que esta espécie é gerada à taxa de 2,8.10-4 s-1; para HB:La3+ (1:1) obteve-se aumento de 32% na geração de oxigênio singleto em relação à HB, e para HB:La3+ (1:2), determinou-se taxa de 3,0.10-4 s-1 pelo método indireto. Com base nos dados experimentais obtidos, verificou-se que o melhor dentre os complexos estudados foi o HB:La3+ (1:2), sendo este e seu precursor HB então aplicados em testes de PDT antimicrobiana in vitro, constituindo a segunda etapa do trabalho. A concentração de HB ideal para trabalho obtida foi de 10 M. Notou-se eliminação total de microorganismos com apenas 30 segundos de irradiação com LED de 460 nm e intensidade de 333 mW/cm2 tanto para o complexo como para o seu precursor. Porém, com excitação em 660 nm com esta mesma intensidade, apenas HB:La3+ (1:2) se mostrou efetivo, chegando ao efeito fotodinâmico total após 6 minutos de irradiação; a redução causada pela HB no mesmo intervalo de tempo foi bem menos pronunciada, o que comprova a eficiência do fotossensibilizador produzido. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
537

Estudo dos defeitos TLsup(0)(1) e INsup(0)(1) em aletos alcalinos: protótipo de um centro de cor como meio laser ativo

VIEIRA JUNIOR, NILSON D. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:01Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:16Z (GMT). No. of bitstreams: 1 12443.pdf: 2922274 bytes, checksum: 7d02b1a5da45929ce2a07f698d1c4935 (MD5) / Tese (Doutoramento) / IEA/T / Instituto de Fisica, Universidade de Sao Paulo - IF/USP
538

Otimizacao do metodo de polimerizacao para producao de detectores plasticos cintiladores de grandes dimensoes

COSTA, NELSON P. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:43:46Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:55Z (GMT). No. of bitstreams: 1 06650.pdf: 4804396 bytes, checksum: 4f29fb57f44398a132f7549c46a4c525 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
539

Validacao de metodos para as tecnicas de WDXRF e OES-SPARK na analise de acos. Calculo de incerteza de medicao para amostras de process, aco classe API / Validation of methods for WDXRF and OES-SPARK techniques in steel analysis. Determination of the uncertainty of measurements for API steel plant sample

SILVA, CARLOS E. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:26:15Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:10:32Z (GMT). No. of bitstreams: 0 / Em conseqüência do aumento da demanda de gás e petróleo no mercado nacional e internacional, as especificações e certificações dos resultados de analises químicas de tubos para gasodutos e oleodutos têm se tornados cada vez mais exigentes. Um contínuo desenvolvimento tem sido realizado para a melhoria de aços microligados da classe API (American Petroleum Institute). As propriedades do aço dependem do controle da composição química e parâmetros de processo durante sua fabricação. Neste trabalho, foi realizada comparação das incertezas de medição entre as técnicas de espectrometria de fluorescência de raios X por comprimento de onda (WDXRF) e de emissão óptica com fonte de arco voltaico (OES-spark) nas análises de acompanhamento de processo na produção de aços classe API. Usualmente, este tipo de análise requer menos de 40 segundos para completa caracterização química para ajuste nos parâmetros de processo de produção. As principais fontes de influência nas análises químicas foram avaliadas por planejamento de experimentos. Os elementos constituintes e traço como Al, Si, P, S, Ti, V, Cr, Mn, Co, Ni, Cu, As, Nb, Mo e Sn foram determinados utilizando as metodologias normalizadas pela ASTM E-322, E-415, E-1009 e E-1085. Os materiais de referência certificados 185A e 187A da CMI (Czech Metrology Institute) foram utilizados para avaliação dos métodos. As incertezas das medições de resultados e a validação com relação a repetitividade e reprodutibilidade das medições foram obtidas conforme os testes estatísticos, recomendados pela norma ISO/IEC 17025. A incerteza de medição para cada elemento é discutida para ambas as técnicas. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
540

Desenvolvimento de um algoritimo otimizado para caracterização de fluxos microfluídicos utilizando padrões de speckle presentes no sinal de tomografia por coerência óptica / Development of an optimized algorithm for the characterization of microflow using speckle patterns present in optical coherence tomography signal

PRETTO, LUCAS R. de 11 June 2015 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2015-06-11T17:44:49Z No. of bitstreams: 0 / Made available in DSpace on 2015-06-11T17:44:49Z (GMT). No. of bitstreams: 0 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O presente trabalho abordou o sistema de Tomografia por Coerência Óptica (OCT) e sua aplicação à área de microfluídica. Para tanto, foram realizados testes de caracterização física de circuitos microfluídicos, utilizando modelos 3D (tridimensionais) construídos a partir de imagens de OCT destes circuitos. A técnica foi, assim, avaliada como potencial ferramenta de auxílio na aferição de microcanais. Indo além, este trabalho estuda e desenvolve técnicas de análise para fluxos microfluídicos, em especial técnicas baseadas no padrão de speckle. Em primeiro momento, métodos já existentes foram estudados e aprimorados, como o Speckle Variance OCT, em que foi obtido um ganho de 31% em tempo de processamento. Outros métodos, como o LASCA (Laser speckle Contrast Analysis), baseados na autocorrelação de speckle, são adaptados às imagens de OCT. Derivado do LASCA, o método de análise desenvolvido baseado na autocorrelação de intensidade motivou o desenvolvimento de um arranjo de OCT próprio e software de aquisição customizado, com taxa de amostragem da ordem de 8 kHz. O método proposto foi, então, capaz de distinguir fluxos volumétricos variados, e seus limites de detecção foram testados, comprovando sua viabilidade de aplicação para análise de movimento browniano e fluxos volumétricos abaixo de 10 μl/min. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP / FAPESP:13/05492-9

Page generated in 0.0974 seconds