• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • Tagged with
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Contrôle acoustique d'un parc éolien / Acoustic control of wind farms

Dumortier, Baldwin 25 September 2018 (has links)
Actuellement, la construction d’un parc éolien nécessite une étude acoustique qui doit assurer la tranquillité des habitants aux alentours et la conformité au regard de la réglementation en vigueur. Pour ce faire, des mesures acoustiques sont réalisées sur une période d’environ deux semaines. Durant ces mesures, des cycles de marche et d’arrêt des machines sont réalisés afin de mesurer la différence de niveau sonore entre le bruit ambiant (éoliennes en fonctionnement) et le bruit résiduel (éoliennes à l’arrêt). Un plan de bridage des machines est alors calculé et fourni à l’exploitant afin de l’implémenter dans le système de contrôle local des éoliennes (SCADA). Actuellement, ce plan dépend grossièrement des conditions météorologiques et des périodes de la journée, supposées corrélées aux conditions acoustiques. En pratique, cette manière de procéder engendre fréquemment des dépassements du critère réglementaire et/ou des pertes de production électrique. Ceci est dû aux conditions acoustiques qui évoluent sans cesse, à la fois pour le bruit particulier (bruit des éoliennes seules) qui dépend finement des conditions météorologiques, et pour le bruit résiduel qui dépend de toutes les autres sources de l’environnement et qui est fondamentalement de nature stochastique. La thèse vise à proposer un algorithme de contrôle du parc éolien en temps réel basé sur un nouveau paradigme de contrôle. On y étudie la possibilité de contrôler un parc éolien à partir d’un système en boite noire d’estimation temps-réel du niveau résiduel et du niveau particulier par séparation de sources. Dans le manuscrit, on définit tout d’abord une formulation du problème dans le cadre du contrôle en identifiant les problématiques propres à ce sujet, une définition des variables du problème et en se rattachant à l’état de l’art du contrôle. Ensuite, on propose deux solutions complètes de contrôle et une évaluation expérimentale. La première est une solution déterministe, qui s’appuie sur un algorithme d’optimisation combinatoire sous contrainte, et qui s’inspire du contrôle actuel des parcs éoliens tout en tenant compte de l’estimation par séparation de sources, alors supposée exacte. On y propose en outre une étude de la capacité du système déterministe à satisfaire le critère réglementaire français qui est aujourd’hui calculé à l’aide de médianes temporelles des variables acoustiques. La seconde est une solution stochastique, qui est basée sur une représentation d’état des variables acoustiques et des incertitudes gaussiennes. Elle inclut un filtrage de Kalman non-linéaire, afin de fusionner l’incertitude sur le modèle acoustique et l’incertitude de séparation de sources, un algorithme espérance-maximisation afin de ré-estimer les incertitudes du problème qui varient d’un parc à un autre, et une adaptation robuste de l’algorithme combinatoire afin de prendre en compte les incertitudes estimées / Currently, acoustic studies are required to set wind farms up. They must ensure the tranquility of the inhabitants around the farms in accordance with current regulations. For this purpose, acoustic measurements are made during a couple of weeks. When measuring, the wind turbines are periodically stopped in order to evaluate the difference between ambient noise levels (with the turbines on) and residual noise levels (with the turbines off). A curtailment plan is then computed and sent to the wind farm owner in order to set it up in the local turbine control system (SCADA). Currently, the curtailment plan roughly depends on the weather conditions and the time of the day which are allegedly correlated to the acoustic variables. In practice, it frequently leads to violations of the acoustic constraints or electrical power loss. This is because the acoustic conditions constantly and strongly evolve over time: the wind turbine noise level finely depends on the weather conditions and the residual noise level depends on all the other acoustic sources and has therefore a stochastic nature. The goal of the thesis is to design a principled real-time control algorithm for wind farms. To do so, we investigate the use of a black-box source separation system that estimates the residual noise level and the wind turbine noise level. We first provide a theoretical formulation of the problem by accounting for specific practical issues, by defining the variables of the problem and by binding these issues to the state of the art. Then, we propose two complete control solutions and run an experimental evaluation. The first solution is a deterministic algorithm based on a constrained combinatorial optimization algorithm, which is inspired by the current approach for controlling wind farms while exploiting the source separation system. Moreover, we present a study of its ability to fulfill the French acoustic constraints that are computed as temporal medians of the acoustic variables. The second solution is stochastic and based on a state-space model defined by means of Gaussian uncertainties. It features a nonlinear Kalman filter in order to fuse the uncertainties of the model and of the source separation system, an Expectation-Maximization algorithm that computes the uncertainties for a specific farm, and a robust variant of the deterministic algorithm that takes the estimated uncertainties into account when computing the optimal command
2

Stratégies de commande pour déplacer une meute de capteurs dédiés à l'identification de sources chauffantes mobiles / Control strategies of mobiles sensors for quasi on-line identification of mobile heating source

Tran, Thanh phong 29 June 2017 (has links)
De nombreux systèmes physiques complexes sont modélisés à l’aide de systèmes d’équations aux dérivées partielles comprenant éventuellement des couplages et des non linéarités. Dans ce cadre, les problématiques de commande qui cherchent à définir quels sont les moyens d’actions (éventuellement en dimension infinie) permettant d’atteindre un état désiré ne sont pas triviales.Il en est de même pour l’identification en ligne de caractéristiques du système physique à partir d’informations fournies par des observations pertinentes. Cet aspect est souvent considéré comme un problème inverse dont la résolution pose de nombreuses questions spécifiques et ardues.Afin d’illustrer la problématique du déplacement judicieux d’un ensemble de capteurs mobiles pour reconstruire un terme source dans une équation aux dérivées partielles paraboliques, un dispositif est décrit dans cette étude. Il décrit des phénomènes de convection et diffusion éventuellement non linéaires.Le travail décrit dans ce document est destiné à développer une méthodologie complète en vue de réaliser une conception optimale d'expériences dans le cadre de problèmes mal posés non linéaires associés à l'évaluation de paramètres inconnus dans des systèmes décrits par des équations aux dérivées partielles. Le prototype expérimental a pour objet de tester les performances des stratégies de déploiement optimal d'un ensemble de capteurs mobile afin d’identifier des paramètres de plusieurs sources chauffantes en mouvement. / Many complex physical systems are modeled using systems of partial differential equations including possibly coupling and non-linearity. In this context, the determination of control strategies (in infinite dimension) in order to achieve a desired state is not trivial. It is obvious that quasi on-line identification of characteristics of the physical system from information provided by relevant sensors is quite complex. This optimization problem is often formulated as an inverse problem, whose resolution raises many specific questions. To illustrate the problem of the moving of a set of mobile sensors to identify a term source in parabolic partial differential equations, an experimental device is proposed in this study. Both phenomena of convection and diffusion (possibly non-linear) are taken into account. The work described in this document is intended to develop a comprehensive methodology to achieve an optimal design of experiments for nonlinear ill-posed problems associated with the evaluation of unknown parameters in systems described by partial differential equations. The experimental prototype is intended to test the performance of strategies for optimal deployment of a mobile set of sensors to identify parameters of multiple heating sources in movement.

Page generated in 0.0697 seconds