A model predictive control strategy for load shifting in a water pumping scheme with maximum demand charges

Van Staden, Adam Jacobus 24 August 2010 (has links)
The aim of this research is to affirm the application of closed-loop optimal control for load shifting in plants with electricity tariffs that include time-of-use (TOU) and maximum demand (MD) charges. The water pumping scheme of the Rietvlei water purification plant in the Tshwane municipality (South Africa) is selected for the case study. The objective is to define and simulate a closed-loop load shifting (scheduling) strategy for the Rietvlei plant that yields the maximum potential cost saving under both TOU and MD charges. The control problem is firstly formulated as a discrete time linear open loop optimal control model. Thereafter, the open loop optimal control model is converted into a closedloop optimal control model using a model predictive control technique. Both the open and closed-loop optimal control models are then simulated and compared with the current (simulated) level based control model. The optimal control models are solved with integer programming optimization. The open loop optimal control model is also solved with linear programming optimization and the result is used as an optimal benchmark for comparisons. Various scenarios with different simulation timeouts, switching intervals, control horizons, model uncertainty and model disturbances are simulated and compared. The effect of MD charges is also evaluated by interchangeably excluding the TOU and MD charges. The results show a saving of 5.8% to 9% for the overall plant, depending on the simulated scenarios. The portion of this saving that is due to a reduction in MD varies between 69% and 92%. The results also shows that the closed-loop optimal control model matches the saving of the open loop optimal control model, and that the closed-loop optimal control model compensates for model uncertainty and model disturbances whilst the open loop optimal control model does not. AFRIKAANS : Die doel van hierdie navorsing is om die applikasie van geslote-lus optimale beheer vir las verskuiwing in aanlegte met elektrisiteit tariewe wat tyd-van-gebruik (TVG) en maksimum aanvraag (MA) kostes insluit te bevestig. Die water pomp skema van die Rietvlei water reiniging aanleg in die Tshwane munisipaliteit (Suid-Afrika) is gekies vir die gevalle studie. Die objektief is om 'n geslote-lus las verskuiwing (skedulering) strategie vir die Rietvlei aanleg te definieer en te simuleer wat die maksimum potensiaal vir koste besparing onder beide TVG en MA kostes lewer. Die beheer probleem is eerstens gevormuleer as 'n diskreet tyd lineêre ope-lus optimale beheer model. Daarna is die ope-lus optimale beheer model aangepas na ‘n geslote-lus optimale beheer model met behulp van 'n model voorspellende beheer tegniek. Beide die ope- en geslote-lus optimale beheer modelle is dan gesimuleer en vergelyk met die huidige (gesimuleerde) vlak gebaseerde beheer model. Die optimisering van optimale beheer modelle is opgelos met geheeltallige programmering. Die optimisering van die ope-lus optimale beheer model is ook opgelos met lineêre programmering en die resultaat is gebruik as 'n optimale doelwit vir vergelykings. Verskeie scenarios met verskillende simulasie stop tye, skakel intervalle, beheer horisonne, model onsekerheid en model versteurings is gesimuleer en vergelyk. Die effek van MA kostes is ook geevalueer deur inter uitruiling van die TVG en MA kostes. Die resultate toon 'n besparing van 5. 8% tot 9% vir die algehele aanleg, afhangend van die gesimuleerde scenarios. Die deel van die besparing wat veroorsaak is deur 'n vermindering in MA wissel tussen 69% en 92%. Die resultate toon ook dat die geslote-lus optimale beheer model se besparing dieselfde is as die besparing van die ope-lus optimale beheer model, en dat die geslote-lus optimale beheer model kompenseer vir model onsekerheid en model versteurings, terwyl die ope-lus optimale beheer model nie kompenseer nie. Copyright / Dissertation (MEng)--University of Pretoria, 2010. / Electrical, Electronic and Computer Engineering / unrestricted
2

Optimal sizing and operation of pumping systems to achieve energy efficiency and load shifting

Zhang, He 22 September 2011 (has links)
This dissertation presents a pumping system operation efficiency improvement solution that includes optimal selection and control of the water pump. This solution is formulated based on the performance, operation, equipment and technology (POET) framework. The focus is on the minimization of the operational energy cost. This efficiency improvement solution is divided into three stages in accordance with the operation category of the POET framework. The first stage is to select the optimal pump capacity by considering both energy efficiency and load shifting requirements. The second stage is to develop a flexible pump controlling strategy that combines and balances the contributions from energy efficiency and load shifting. The last stage is to improve the robustness of the control system using the closed-loop model predictive control approach. An optimal pump capacity selection model is formulated. In this model, additional capacity requirements for load shifting are considered along with the traditional energy efficiency requirements. By balancing the contributions from load shifting and energy efficiency, the operational energy cost can be reduced by up to 37%. An optimal pump control is formulated. The objective of this control model is to balance the energy efficiency and load shifting contributions during the operation and minimize the operational energy cost. This control model is tested under different operational conditions and it is compared to other existing control strategies. The simulation and comparison results show that the proposed control strategy achieves the lowest operational energy cost in comparison to other strategies. This optimal pump control model is further modified into the closed-loop model predictive control format to increase the robustness of the control system under operation uncertainties. A mixed integer particle swarm optimization algorithms is employed to solve the optimization problems in this research. AFRIKAANS : Hierdie verhandeling bied ’n verbeterde oplossing vir die operasionele doeltreffendheid van pompstelsels wat die optimale keuse en beheer van die waterpomp insluit. Hierdie oplossing is geformuleer op ’n raamwerk wat werkverrigting, bedryf, toerusting en tegnologie in ag neem. Die oplossing fokus op die vermindering van bedryfsenergie koste. Hierdie oplossing is onderverdeel in drie fases soos bepaal deur die bedryfskategorie gegrond op die bogenoemde raamwerk: Die eerste fase is die keuse van die optimale pompkapasiteit deur beide energiedoeltreffendheid en lasverskuiwing in ag te neem. Die tweede fase is om ’n buigbare pompbeheer strategie te ontwikkel wat ’n goeie balans handhaaf tussen die onderskeie bydraes van energiedoeltreffendheid en lasverskuiwing. Die derde fase is om die stabiliteit van die beheerstelsel te verbeter deur gebruik te maak van ’n geslote-lus beheermodel met voorspellende beheer (Predictive Control). ’n Model vir die keuse van optimale pompkapasiteit is geformuleer. In hierdie model word vereistes vir addisionele pompkapasiteit vir lasverskuiwing sowel as vereistes in terme tradisionele energiedoeltreffendheid in ag geneem. Deur die regte verhouding tussen die onderskeie bydraes van energiedoeltreffendheid en lasverskuiwing te vind kan ’n besparing van tot 37% op die energiekoste verkry word. Optimale pompbeheer is geformuleer. Die doel van die beheermodel is om die bydraes van energiedoeltreffendheid en lasverskuiwing te balanseer en om die bedryfsenergie koste te minimiseer. Hierdie beheermodel is getoets onder verskillende bedryfstoestande en dit is vergelyk met ander bestaande beheerstrategiee. Die simulasie en vergelyking van resultate toon dat die voorgestelde beheerstrategie die laagste bedryfsenergie koste behaal in vergelyking met ander strategiee. Hierdie optimale pomp beheermodel is verder aangepas in ’n geslote beheermodel met voorspellende beheerformaat om die stabiliteit van die beheerstelsel te verbeter onder onsekere bedryfstoestande. ’n Gemende heelgetal partikel swerm optimisasie (Mixed interger particle swarm optimization) algoritme is gebruik om die optimiseringsprobleme op te los tydens hierdie navorsingsoefening. / Dissertation (MEng)--University of Pretoria, 2011. / Electrical, Electronic and Computer Engineering / Unrestricted