Spelling suggestions: "subject:"ortodontia estabilidade"" "subject:"ortodontia stabilidade""
1 |
DETERMINAÇÃO DAS FORMAS DO ARCO DENTÁRIO INFERIOR NA OCLUSÃO NORMAL NATURALTriviño, Tarcila 02 March 2005 (has links)
Made available in DSpace on 2016-08-03T16:31:09Z (GMT). No. of bitstreams: 1
Trivino T.pdf: 22091 bytes, checksum: f8158ccecd4c4b563ce8a5bf81d03ae5 (MD5)
Previous issue date: 2005-03-02 / Com a finalidade de determinar as formas do arco dentário inferior de maior incidência na oclusão normal natural, utilizou-se um método matemático associado ao emprego de uma função polinomial, o qual foi aplicado a 63 modelos de arcadas inferiores selecionados a partir de 6118 adolescentes. Todos
os indivíduos eram portadores de dentição permanente, incluindo os segundos molares, e oclusão normal natural. Em cada dente foi fixada uma esfera de vidro, que teve a função de simular o acessório do aparelho ortodôntico, sendo utilizada
na medição das distâncias entre o centro da imagem dessas esferas aos eixos x e y. Após a digitalização dos modelos de gesso, as imagens foram plotadas em um programa de computador, a fim de se obterem a função polinomial de sexto grau e o gráfico dessa função para os 126 segmentos de curva, originados das secções das imagens em lado direito e esquerdo. A seguir organizaram-se esses segmentos, de acordo com as características da curvatura anterior dos arcos
dentários, em oito grupos diferentes de formas, que receberam as denominações de Forma A, Forma B, Forma C, Forma D, Forma E, Forma F, Forma G, Forma H. Cada grupo foi, então, dividido em três subgrupos, conforme os tamanhos
pequeno, médio e grande. Os resultados indicaram 23 formas representativas do arco dentário inferior e uma forma média para a oclusão normal natural.
|
2 |
AVALIAÇÃO DA ESTABILIDADE DAS ALTERAÇÕES PROMOVIDAS PELO APARELHO REGULADOR DE FUNÇÃO FRÄNKEL-2 NOS ARCOS DENTÁRIOS / Evaluation of occlusal changes stability obtained by Fränkel s function regulator- 2 in dental archesTanaka, Tânia Gnecchi 18 February 2008 (has links)
Made available in DSpace on 2016-08-03T16:31:11Z (GMT). No. of bitstreams: 1
TANIA GNECCHI TANAKA.pdf: 1091027 bytes, checksum: c0f0a2aaf27893d2606dd406f55aac7e (MD5)
Previous issue date: 2008-02-18 / This study analyzed the stability of occlusal alterations promoted by the Fränkel function regulator type 2 (FR-2), on a mean posttreatment period of 7.16 years. The study was conducted on 54 pairs of dental casts obtained from 18 patients with Class II division 1 malocclusion, with initial mean age of 10.77 years, treated with the RF-2 for 18 months and reevaluated after a mean period of 7.16 years. The dental casts were evaluated at treatment onset (T1), treatment completion (T2) and at 7.16 years after treatment (T3). Analysis comprised transverse and sagittal alterations, the Little irregularity index, as well as the treatment priority index (TPI). Changes occurring in the study periods were assessed by analysis of variance (ANOVA) followed by the Bonferroni test for multiple comparisons, at a significance level of 0.05. The results revealed that treatment with the FR-2 promoted a statistically significant transverse increase in both maxillary and mandibular arches; however, at the posttreatment period, there was partial or total relapse of this increase in most dimensions investigated. Maxillary and mandibular arch lengths were reduced throughout the study period. The Little irregularity index was stable during treatment, yet was increased at the posttreatment period. Moreover, treatment with the FR-2 provided a statistically significant decrease in the TPI, indicating the efficacy of treatment, which was stable at the posttreatment period. Therefore, the appliance FR-2 demonstrated to be effective for dental correction of Class II division 1 malocclusion, with stability of results at 7.16 years after treatment. However, with regard to the transverse increase in dental arches obtained during treatment, there was partial or total relapse of all variables analyzed.(AU) / O objetivo do presente estudo consistiu em analisar a estabilidade das alterações oclusais em 18 pacientes com má oclusão de Classe II, divisão 1, idade média inicial de 10,77 anos, tratados com o aparelho regulador de função RF-2 durante 18 meses e reavaliados num período de pós-tratamento 7,16 anos, em média. Os 54 modelos de gesso foram avaliados no início do tratamento (T1), no final do tratamento (T2) e decorridos 7,16 anos pós-tratamento (T3). Foram analisadas as alterações transversais e sagitais; o Índice de irregularidade de Little e o Índice de Prioridade de Tratamento (IPT). As alterações ocorridas nos períodos analisados foram verificadas por meio da análise de Variância- ANOVA e, em seguida, pelo teste de comparações múltiplas de Bonferroni, com o valor crítico adotado de 0,05. Os resultados demonstraram que o tratamento com o RF-2 promoveu um aumento transversal estatisticamente significante, tanto no arco dentário superior quanto no inferior, porém, no período pós-tratamento, houve recidiva parcial ou mesmo total deste aumento na maioria das dimensões analisadas. Já o comprimento dos arcos dentários superior e inferior diminuiu durante todo o período avaliado. O Índice de Irregularidade de Little apresentou-se estável durante o tratamento, entretanto aumentou no período pós-tratamento. Além disso, o tratamento com o RF-2 proporcionou uma diminuição estatisticamente significante do IPT, refletindo a eficácia do tratamento realizado uma vez que esta diminuição permaneceu estável no período pós-tratamento. Portanto, o aparelho RF-2 demonstrou ser eficaz na correção dentária da má oclusão de Classe II, divisão 1, com estabilidade dos resultados decorridos 7,16 anos após o tratamento. Porém, em relação ao ganho transversal nos arcos dentários obtido durante o tratamento, houve recidiva parcial ou total de todas as variáveis analisadas.(AU)
|
Page generated in 0.0533 seconds