• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

SO2 and O2 separation by using ionic liquid absorption / S.L. Rabie

Rabie, Samuel Liversage January 2012 (has links)
In order to reduce the amount of pollution that is generated by burning fossil fuels alternative energy sources should be explored. Hydrogen has been identified as the most promising replacement for fossil fuels and can be produced by using the Hybrid Sulphur (HyS) cycle. Currently the SO2/O2 separation step in the HyS process has a large amount of knock out drums. The aim of this study was to investigate new technology to separate the SO2 and O2. The technology that was identified and investigated was to separate the SO2 and O2 by absorbing the SO2 into an ionic liquid. In this study the maximum absorption, absorption rate and desorption rate of SO2 from the ionic liquid [BMIm][MeSO4] with purities of 95% and 98% was investigated. These ionic liquid properties were investigated for pure O2 at pressures ranging from 1.5 to 9 bar(a) and for pure SO2 at pressures from 1.5 to 3 bar(a) at ambient temperature. Experiments were also carried out where the composition of the feed-stream to the ionic liquid was varied with compositions of 0, 25, 50, 75 and 100 mol% SO2 with O2 as the balance. For each of these compositions the temperature of the ionic liquid was changed from 30oC to 60oC, in increments of 10oC. The absorption rate of SO2 in the ionic liquid increased when the mole percentage SO2 in the feed stream was increased. When the temperature of the ionic liquid was decreased the maximum amount of SO2 that the ionic liquid absorbed increased dramatically. However, the absorption rate was not influenced by a change in the absorption temperature. The experimental results for the maximum SO2 absorption were modelled with the Langmuir absorption model. The model fitted the data well, with an average standard deviation of 17.07% over all the experiments. In order to determine if the absorption reaction was endothermic or exothermic the Clausius-Clapeyron equation was used to calculate the heat of desorption for the desorption step. The heat of desorption data indicated that the desorption of SO2 from this ionic liquid was an endothermic reaction because the heat of desorption values was positive. Therefore the absorption reaction was exothermic. From the pressure-change experiments the results showed that the mole percentage of O2 gas that was absorbed into the ionic liquid was independent of the pressure of the O2 feed.On the other hand, there was a clear correlation between the mole percentage SO2 that was absorbed into the ionic liquid and the feed pressure of the SO2. When the feed pressure of the SO2 was increased the amount of SO2 absorbed also increased, this trend was explained with Fick’s law. In the study the effect of the ionic liquid purity on the SO2 absorption capacity was investigated. The experimental results for the pressure experiments showed that the 95% and 98% pure ionic liquid absorbed about the same amount of SO2. During the temperature experiments the 95% pure ionic liquid absorbed more SO2 than the 98% pure ionic liquid for all but two of the experiments. However the 95% pure ionic liquid also absorbed small amounts of O2 at 30 and 40oC which indicated that the 95% pure ionic liquid had a lower selectivity than the 98% pure ionic liquid. Therefore, the 95% pure ionic liquid had better SO2 absorption capabilities than the 98% pure ionic liquid. These result showed that the 98% pure ionic liquid did not absorb more SO2 than the 95% pure ionic liquid, but it did, however, show that the 98% pure ionic liquid had a better selectivity towards the SO2. Hence, it can be concluded that even with the O2 that is absorbed it would be economically more advantageous to use the less expensive 95% pure ionic liquid rather than the expensive 98% pure ionic liquid, because the O2 would not influence the performance of the process negatively in such low quantities. / Thesis (MIng (Chemical Engineering))--North-West University, Potchefstroom Campus, 2013
2

SO2 and O2 separation by using ionic liquid absorption / S.L. Rabie

Rabie, Samuel Liversage January 2012 (has links)
In order to reduce the amount of pollution that is generated by burning fossil fuels alternative energy sources should be explored. Hydrogen has been identified as the most promising replacement for fossil fuels and can be produced by using the Hybrid Sulphur (HyS) cycle. Currently the SO2/O2 separation step in the HyS process has a large amount of knock out drums. The aim of this study was to investigate new technology to separate the SO2 and O2. The technology that was identified and investigated was to separate the SO2 and O2 by absorbing the SO2 into an ionic liquid. In this study the maximum absorption, absorption rate and desorption rate of SO2 from the ionic liquid [BMIm][MeSO4] with purities of 95% and 98% was investigated. These ionic liquid properties were investigated for pure O2 at pressures ranging from 1.5 to 9 bar(a) and for pure SO2 at pressures from 1.5 to 3 bar(a) at ambient temperature. Experiments were also carried out where the composition of the feed-stream to the ionic liquid was varied with compositions of 0, 25, 50, 75 and 100 mol% SO2 with O2 as the balance. For each of these compositions the temperature of the ionic liquid was changed from 30oC to 60oC, in increments of 10oC. The absorption rate of SO2 in the ionic liquid increased when the mole percentage SO2 in the feed stream was increased. When the temperature of the ionic liquid was decreased the maximum amount of SO2 that the ionic liquid absorbed increased dramatically. However, the absorption rate was not influenced by a change in the absorption temperature. The experimental results for the maximum SO2 absorption were modelled with the Langmuir absorption model. The model fitted the data well, with an average standard deviation of 17.07% over all the experiments. In order to determine if the absorption reaction was endothermic or exothermic the Clausius-Clapeyron equation was used to calculate the heat of desorption for the desorption step. The heat of desorption data indicated that the desorption of SO2 from this ionic liquid was an endothermic reaction because the heat of desorption values was positive. Therefore the absorption reaction was exothermic. From the pressure-change experiments the results showed that the mole percentage of O2 gas that was absorbed into the ionic liquid was independent of the pressure of the O2 feed.On the other hand, there was a clear correlation between the mole percentage SO2 that was absorbed into the ionic liquid and the feed pressure of the SO2. When the feed pressure of the SO2 was increased the amount of SO2 absorbed also increased, this trend was explained with Fick’s law. In the study the effect of the ionic liquid purity on the SO2 absorption capacity was investigated. The experimental results for the pressure experiments showed that the 95% and 98% pure ionic liquid absorbed about the same amount of SO2. During the temperature experiments the 95% pure ionic liquid absorbed more SO2 than the 98% pure ionic liquid for all but two of the experiments. However the 95% pure ionic liquid also absorbed small amounts of O2 at 30 and 40oC which indicated that the 95% pure ionic liquid had a lower selectivity than the 98% pure ionic liquid. Therefore, the 95% pure ionic liquid had better SO2 absorption capabilities than the 98% pure ionic liquid. These result showed that the 98% pure ionic liquid did not absorb more SO2 than the 95% pure ionic liquid, but it did, however, show that the 98% pure ionic liquid had a better selectivity towards the SO2. Hence, it can be concluded that even with the O2 that is absorbed it would be economically more advantageous to use the less expensive 95% pure ionic liquid rather than the expensive 98% pure ionic liquid, because the O2 would not influence the performance of the process negatively in such low quantities. / Thesis (MIng (Chemical Engineering))--North-West University, Potchefstroom Campus, 2013
3

Physiological and biochemical responses of avocado fruit to controlled atmosphere storage

Basuki, Eko, University of Western Sydney, Hawkesbury, Faculty of Science and Technology January 1998 (has links)
The primary objective of the research was to study the physiological and biochemical changes in Hass avocado fruit stored in different combination of oxygen and carbon dioxide concentrations at both 0 degrees and 5 degrees Centigrade (C), and to determine whether storage in controlled atmosphere (CA) can decrease the incidence of chilling injury (CI). A secondary objective was to identify possible correlations between CA, the incidence of CI, the activity of some ripening related enzymes and changes in proteins during ripening at 20 degrees C following storage at low temperatures. Fruit suffered no CI and ripened normally following CA storage for 3 weeks at both 0 degrees and 5 degrees C, then transferred to air for 6 days at 20 degrees C. CI symptoms did develop after CA storage for 6 and 9 weeks at 0 degrees C. Changes in proteins during ripening were analysed by 2D-PAGE. Some polypeptides were detected in unripe fruit but decreased with ripening. Polypeptides of 16.5, 25, 36 and 56 kD (kilo Dalton) were present early in ripening and their levels further increased during ripening. The appearance of three ripening related polypeptides with estimated molecular weights 80 kD (pI 3.6), 36 kD (pI 5.8) and 16.5 kD (pI 5.7) was observed in fruit at the climacteric stage. Three polypeptides with estimated molecular weights of 41 kD (pI7.8), 36 kD (pI 5.8) and 33 kD (pI 5.1) were found in air stored fruit but were not detected in fruit stored in CA. This research showed that CA did not ameliorate CI at 0 degrees C, instead storage at 0 degrees C caused a premature increase in ethylene production when the fruit were returned to air at 20 degrees C. In contrast, CA storage at 5 degrees C retarded ethylene production and ripening in fruit after it was returned to air at 20 degrees C. / Doctor of Philosophy (PhD)

Page generated in 0.0281 seconds