• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Estudo dos efeitos da radiação gama no polietileno linear de baixa densidade (PELBD) injetado / Study of effects gamma radiation linear low density polyethylene (LLDPE) injected

Oliveira, Ana Claudia Feitoza de 11 July 2014 (has links)
O uso do método de esterilização por radiação gama ajuda na redução da contaminação microbiológica. O polietileno linear de baixa densidade (PELBD) é um polímero de cadeias lineares e ramificações curtas. Neste trabalho o PELBD injetado foi irradiado por uma fonte de 60Co com 2000 kCi de atividade, na presença de ar, em doses de 5, 10, 20, 50 ou 100 kGy e taxas de dose de cerca de 5 kGy.h-1 em temperatura ambiente (25 ºC). Após a irradiação, foi necessário submeter as amostras a um tratamento térmico em uma estufa por 60 min a 100 ºC para a recombinação e aniquilação dos radicais residuais. Na sequência as amostras injetadas foram irradiadas e caracterizadas para identificar os efeitos de degradação térmica, cisão e reticulação em cada dose. Verificou-se uma degradação térmica da resina ao passar pelo processo de modelagem por injeção confirmada pela análise de FTIR. Os PELBD injetados irradiados nas doses de 5, 10 ou 20 kGy tiveram maior tendência a cisão do que aqueles nas doses de 50 ou 100 kGy, nos quais predominou a reticulação. Desta forma determinaram-se os efeitos da irradiação e do processo nos PELBD moldados por injeção. / The use of the method of sterilization by gamma radiation helps in reducing microbiological contamination. The linear low density polyethylene (LLDPE) is a linear polymer chain with short chain branching. In this work, the LLDPE were irradiated in 60Co gamma source with 2000 kCi of activity, in presence of air, with doses of 5, 10, 20, 50 or 100 kGy, at about 5 kGy.h-1 dose rate, at room temperature. After irradiation, the samples were heated for 60 min at 100 ºC to promote recombination and annihilation of residual radicals. In the sequence LLDPE injected samples were irradiated and characterized to identity the effects of terminal degradation, scission end crosslinking occurred in each dose. There was a thermal degradation of the resin through the process of injection molding confirmed by FTIR analysis. And LLDPE injected irradiated at doses of 5, 10 or 20 kGy has a greater tendency to scission than those at doses of 50 or 100 kGy, where predominated crosslinking consequently the effects of irradiation and injection molding were investigated in LLDPE processed.
2

Estudo dos efeitos da radiação gama no polietileno linear de baixa densidade (PELBD) injetado / Study of effects gamma radiation linear low density polyethylene (LLDPE) injected

Ana Claudia Feitoza de Oliveira 11 July 2014 (has links)
O uso do método de esterilização por radiação gama ajuda na redução da contaminação microbiológica. O polietileno linear de baixa densidade (PELBD) é um polímero de cadeias lineares e ramificações curtas. Neste trabalho o PELBD injetado foi irradiado por uma fonte de 60Co com 2000 kCi de atividade, na presença de ar, em doses de 5, 10, 20, 50 ou 100 kGy e taxas de dose de cerca de 5 kGy.h-1 em temperatura ambiente (25 ºC). Após a irradiação, foi necessário submeter as amostras a um tratamento térmico em uma estufa por 60 min a 100 ºC para a recombinação e aniquilação dos radicais residuais. Na sequência as amostras injetadas foram irradiadas e caracterizadas para identificar os efeitos de degradação térmica, cisão e reticulação em cada dose. Verificou-se uma degradação térmica da resina ao passar pelo processo de modelagem por injeção confirmada pela análise de FTIR. Os PELBD injetados irradiados nas doses de 5, 10 ou 20 kGy tiveram maior tendência a cisão do que aqueles nas doses de 50 ou 100 kGy, nos quais predominou a reticulação. Desta forma determinaram-se os efeitos da irradiação e do processo nos PELBD moldados por injeção. / The use of the method of sterilization by gamma radiation helps in reducing microbiological contamination. The linear low density polyethylene (LLDPE) is a linear polymer chain with short chain branching. In this work, the LLDPE were irradiated in 60Co gamma source with 2000 kCi of activity, in presence of air, with doses of 5, 10, 20, 50 or 100 kGy, at about 5 kGy.h-1 dose rate, at room temperature. After irradiation, the samples were heated for 60 min at 100 ºC to promote recombination and annihilation of residual radicals. In the sequence LLDPE injected samples were irradiated and characterized to identity the effects of terminal degradation, scission end crosslinking occurred in each dose. There was a thermal degradation of the resin through the process of injection molding confirmed by FTIR analysis. And LLDPE injected irradiated at doses of 5, 10 or 20 kGy has a greater tendency to scission than those at doses of 50 or 100 kGy, where predominated crosslinking consequently the effects of irradiation and injection molding were investigated in LLDPE processed.
3

CARACTERIZAÇÃO REOLÓGICA E TÉRMICA DE BLENDAS POLIMÉRICAS DE PEBD/ m-PELBD PROCESSADAS EM EXTRUSORAS MONO E DUPLA ROSCA

Patel, Volnei 09 December 2011 (has links)
Made available in DSpace on 2017-07-21T20:42:44Z (GMT). No. of bitstreams: 1 Volnei Patel.pdf: 2182418 bytes, checksum: 0c02f090d39438a33dbc14bd153a4062 (MD5) Previous issue date: 2011-12-09 / In this work, blends of PEBD/m-PELBD with typical applications in the area of packaging films were studied. Thermal and rheological properties of blends of PEBD/m-PELBD were analyzed in the proportions of 80/20; 75/25; 70/30; 65/35;60/40, as well as the pure polymers. The samples were processed in single and twin screw extruders, thus allowing the evaluation of the influence of homogenization on the thermal and rheological properties. The effect of variations of the compositions of the blends on thermal properties was analyzed using the Differential Scanning Calorimetry technique (DSC), and the effect of variation in the rheology of the blends was analyzed in parallel plate and capillary rheometer for the various compositions and at different temperatures. The results obtained from the thermal analysis showed no variations in the melting and crystallization temperatures with variation of the composition, and the pure m-PELBD presented a melting temperature of 108ºC and PEBD 105ºC. The rheological analysis showed the high influence of PEBD in viscosity at low shear rates, presenting high viscosity. However, as of 100 1/s the reversal of the viscosity curves is observed,where m-PELBD has more influence. By means of rheological analysis, the phase behavior of the blends was investigated, which proved insoluble in all compositions in the molten state. However, due to the close proximity of the values of the melting temperature of the pure components, it was not possible to identify the expected second melting peak in the thermal analysis. Comparing the thermal and rheological results of the processed blends in the extruders of single and twin screws, no significant variations were observed. The thermal and rheological results obtained in this study show that possible small variations in composition during the feed dispensing process in the extruder would not generate significant instabilities in the process. / No presente trabalho foram estudadas blendas de PEBD/m-PELBD com aplicações típicas na área de filmes para embalagens. Foram analisadas as propriedades térmicas e reológicas das blendas de PEBD/m-PELBD nas proporções 80/20; 75/25; 70/30; 65/35; 60/40, bem como dos polímeros puros. As amostras foram processadas em extrusoras mono e dupla rosca, desta forma possibilitando avaliar a influencia da homogeneização nas propriedades térmicas e reológicas. O efeito das variações das composições das blendas nas propriedades térmicas foi analisado através da técnica de calorimetria exploratória diferencial (DSC), e os efeitos das variações na reologia da blenda foram analisados em reômetro de placa paralelas e capilar para as diversas composições e em diferentes temperaturas. Os resultados obtidos nas analises térmicas não apresentaram variações nas temperaturas de fusão e cristalização, com variação da composição, sendo que o m-PELBD puro apresentou uma temperatura de fusão de 108ºC, e o PEBD 105ºC. As analises reológicas demonstraram à alta influência do PEBD na viscosidade em baixas taxas de cisalhamento, apresentando viscosidade elevada. Porém, a partir de 100 1/s observa-se inversão das curvas de viscosidade, onde o m-PELBD influencia mais. Através de análises reológicas foi investigado o comportamento de fase das blendas, a qual se mostrou imiscível em todas as composições no estado fundido. Entretanto, devido à grande proximidade dos valores de temperatura de fusão dos componentes puros, na analise térmica não foi possível identificar o segundo pico de fusão esperado. Comparando os resultados reológicos e térmicos das blendas processadas em extrusora de rosca simples e dupla rosca, não foram observadas variações significativas. Os resultados térmicos e reológicos obtidos no presente estudos mostram que possíveis pequenas oscilações de composição durante o processo de dosagem na alimentação da extrusora não gerariam instabilidades significativas no processo.
4

Blendas PEAD/m-PELBD modificadas com argila organofílica.

NASCIMENTO, Uédson Alexandre do. 26 June 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-06-26T11:43:08Z No. of bitstreams: 1 UÉDSON ALEXANDRE DO NASCIMENTO - TESE (PPGCEMat) 2016.pdf: 2537041 bytes, checksum: 43e8f4d37a08e791d0323dc0ce915cb4 (MD5) / Made available in DSpace on 2018-06-26T11:43:08Z (GMT). No. of bitstreams: 1 UÉDSON ALEXANDRE DO NASCIMENTO - TESE (PPGCEMat) 2016.pdf: 2537041 bytes, checksum: 43e8f4d37a08e791d0323dc0ce915cb4 (MD5) Previous issue date: 2016-02-26 / Neste trabalho, blendas de polietileno de alta densidade com polietileno linear de baixa densidade metalocênico, PEAD/m-PELBD, foram preparadas empregando uma extrusora dupla rosca, cônica, contrarotacional interpenetrante e os efeitos do tipo e do teor do m-PELBD nas propriedades de impacto e de tração foram estudados. A blenda PEAD/m-PELBD com melhor relação de propriedades, tenacidade/rigidez, foi modificada com argila montmorilonita organofílica comercial Cloisite 20A, nos teores de 1, 3, 5 e 10 pcr, visando à obtenção de um híbrido com propriedades comparáveis, particularmente, em processamento e tenacidade/rigidez, às da resina de PEAD importada, PEAD Dowlex IP–10262, utilizada para fabricação de embalagens injetadas para o envase e transporte de produtos químicos perigosos. De acordo com os resultados da caracterização mecânica (impacto e tração), ficou evidenciado que o tipo e o teor de m-PELBD influenciaram nestas propriedades. Dentre os m-PELBDs estudados, Flexus 7200 e Flexus 9200, o Flexus 7200 resultou na melhor relação de propriedades e dentre os teores avaliados (10, 17 e 25%), o teor de 17% foi mais efetivo. A blenda PEAD/17% m-PELBD, blenda 7217, apresentou resistência à tração no escoamento comparável a da resina importada; resistência ao impacto 57,7% superior e módulo elástico 23,6% inferior. Como a rigidez da blenda 7217 foi inferior à da resina importada, a mesma foi modificada com a argila Cloisite 20A. De acordo com os dados de difratometria de raios X (DRX), a incorporação da argila à blenda 7217, em todos os teores estudados, não resultou na formação de nanocompósitos. Apesar disso, as propriedades de cristalinidade (determinada por calorimetria exploratória diferencial – DSC) e de estabilidade térmica (determinada por termogravimetria - TGA) da blenda 7217 modificada com 10 pcr de argila (7217AO-10), foram superiores as da blenda pura. A resistência à tração foi mantida, a resistência ao impacto diminuiu e o módulo elástico aumentou, em relação a blenda pura. Em comparação com a resina importada, a resistência à tração do híbrido 7217AO-10 foi 8% superior, a resistência ao impacto foi 12% inferior e o módulo elástico 7% inferior. De forma geral, a blenda 7217, modificada com 10 pcr de argila, apresentou processabilidade e propriedades mecânicas comparáveis as da resina importada (PEAD Dowlex IP–10262). / Blends of high density polyethylene with metallocene linear low density polyethylene, HDPE/m-LLDPE, were prepared by melt compounding in a twin-screw extruder. The m-LLDPE type and content effects on impact and tensile properties were studied. According to the results, these parameters influenced the properties of m-LLDPE. The blend prepared with m-LLDPE Flexus 7200 with the 17% concentration (7217 blend) showed the best properties. However, their hardness was lower than the HDPE Dowlex IP-10262 resin, used for dangerous chemicals transport containers manufacture. The 7217 blend was modified with organophilic montmorillonite (Cloisite 20A organoclay). The diffraction X-ray data (XRD) showed that the 7217 blend modification, with organoclay, on all studied concentrations, did not result in nanocomposites. Nevertheless, the crystallinity properties (determined by differential scanning calorimetry – DSC) and thermal stability (determined by thermogravimetric analysis – TGA) of the 7217 blend, modified with 10 phr of organoclay (7217AO-10) were higher than the pure blend. In addition, the modified blend showed decreased impact resistance, increased elastic modulus and the same tensile strength. As compared to Dowlex IP-10262 HDPE, the tensile strength of 7217AO-10 hybrid was 8% higher, the impact strength was 12% lower and the elastic modulus was 7% lower. In general, the processability and mechanical properties of 7217 blend, modified with 10phr of Cloisite 20A, were similar to that HDPE Dowlex IP-10262. Therefore, this hybrid has great use potencial for dangerous chemicals transport containers manufacture, replacing the HDPE Dowlex IP-10262 resin.

Page generated in 0.025 seconds