Projeto de paredes de concreto armado: apresentação das recomendações normativas e avaliação da influência da aberturasVieira, Luara Batalha 31 July 2014 (has links)
Submitted by Giada Bettazzi (giada_firenze@hotmail.com) on 2014-09-29T21:20:02Z
No. of bitstreams: 2
Dissertação_Luara_Batalha_Vieira.pdf: 3887739 bytes, checksum: 9ce466cc66f1ae5424167fd5150bcc7a (MD5)
Artigo_ Luara_Batalha.pdf: 562471 bytes, checksum: bfc4d1fdb3823297a291161b5657a78d (MD5) / Approved for entry into archive by Rodrigo Meirelles (rodrigomei@ufba.br) on 2014-09-30T13:16:22Z (GMT) No. of bitstreams: 2
Dissertação_Luara_Batalha_Vieira.pdf: 3887739 bytes, checksum: 9ce466cc66f1ae5424167fd5150bcc7a (MD5)
Artigo_ Luara_Batalha.pdf: 562471 bytes, checksum: bfc4d1fdb3823297a291161b5657a78d (MD5) / Made available in DSpace on 2014-09-30T13:16:22Z (GMT). No. of bitstreams: 2
Dissertação_Luara_Batalha_Vieira.pdf: 3887739 bytes, checksum: 9ce466cc66f1ae5424167fd5150bcc7a (MD5)
Artigo_ Luara_Batalha.pdf: 562471 bytes, checksum: bfc4d1fdb3823297a291161b5657a78d (MD5) / CAPES / Este trabalho descreve e comenta os fundamentos contidos na NBR 16055 (2012), abordando os materiais utilizados, os procedimentos construtivos e o dimensionamento das paredes de concreto armado, com e sem aberturas. Além da norma brasileira, são comentadas as seguintes normais internacionais: ACI 318M Building Code Requirements for Strucutral Concrete (2008), Designer’s handbook to Eurocode 2: Parte 1.1: Design of concrete structures (1992) e CEB-FIP Model Code (1990). Por fim, são apresentados os resultados do estudo da influência das aberturas no comportamento das paredes de concreto. Para isso, com o auxílio do programa computacional ANSYS®, foram analisadas várias paredes nas quais, tanto as dimensões, quanto as aberturas foram variadas.
|
2 |
Desempenho térmico de habitações do PMCMV em paredes de concreto : estudo de caso em São Carlos-SP e diretrizes de projeto para a Zona Bioclimática 4 / Thermal sensation in low-income brazilian houses built in concrete wallsAlvares, Simone Mesquita 13 June 2018 (has links)
O atual programa de contenção do déficit habitacional brasileiro, Minha Casa Minha Vida, criado em 2009, apesar de numericamente significativo, apresenta uma série de complicações e inadequações. Um importante exemplo é a inadequação das construções à Zona Bioclimática na qual o projeto é construído. Diante desse fato, o conforto térmico do usuário deixa a desejar pois os ambientes são desconfortáveis e nada sustentáveis do ponto de vista ambiental. Neste contexto, o trabalho teve como objetivo avaliar o desempenho térmico de habitações de interesse social do PMCMV na Zona Bioclimática 4 construídas com paredes de concreto armado moldadas no local, técnica de rápida execução que vem sendo utilizada em larga escala no país; complementarmente, foi analisada a percepção do usuário frente às condições de conforto térmico em um desses residenciais. A avaliação do desempenho térmico das habitações foi feita com base nos regulamentos nacionais NBR 15220 e NBR 15575 em seus procedimentos simplificados; para avaliar a ventilação, via método de visualização de escoamento (mesa dágua) e a insolação, via simulação computacional de horas de sombreamento com auxílio de cartas solares; para a avaliação da percepção do usuário frente ao conforto térmico, foram feitas pesquisas de campo em um dos empreendimentos de habitações sociais na zona em estudo tendo como base os questionários ASHRAE 55 juntamente com coleta de dados climáticos de temperatura e umidade relativa e com levantamento de modificações projetuais. A partir dos dados coletados, pôde-se confirmar objetivamente a inadequação aos limites mínimos estabelecidos pelas normas de desempenho térmico nos parâmetros de vedação vertical e cobertura. Em entrevista com os moradores, as casas foram consideradas desconfortáveis termicamente no inverno e verão. A partir do diagnóstico das alterações nos projetos, nota-se que a maior parte das casas sofrem alterações para maior adequação à vida dos moradores, essas que se tornam responsáveis pelo desconforto térmico. Fica evidente a necessidade do aumento da inércia térmica do sistema construtivo, para futuras casas construídas com o referido sistema além da necessidade de um plano de expansão da moradia que oriente o morador a fazer modificações que não prejudiquem o desempenho térmico do edifício e o conforto térmico dos habitantes. / The current Brazilian low-income housing program, named Minha Casa Minha Vida, was created in 2009 by the Brazilian government and despite being numerically significant, it has many significant issues that affect its quality. One important example is the used construction methods that do not take into account the climate or the bioclimatic zones where the houses are located resulting in energy efficiency, environmental and thermal confirm issues. This work is developed in this context and aims to evaluate the objective and subjective thermal performance of the houses built in the Zone 4 with reinforced concrete walls molded in place, which is a widespread construction technique within the studied program. Thermal performance of the dwellings was analyzed in the light of the Brazilian regulation norm NBR15220 and NBR 15575. Surveys based on ASHRAE 55 norm were conducted to evaluate the user\'s thermal comfort perception and in situ measurements were taken at the studied bioclimatic zone. From the data collected, we conclude that the houses do not meet the norm limits and that they are also subjectively uncomfortable, during summer and winter. As means to increase comfort, we note that all houses dwellers modified their houses making it clear that future houses should have more thermal inertia and that, as the program expands, dwellers should be instructed to not make construction changes that might affect their thermal comfort.
|
3 |
Desempenho térmico de habitações do PMCMV em paredes de concreto : estudo de caso em São Carlos-SP e diretrizes de projeto para a Zona Bioclimática 4 / Thermal sensation in low-income brazilian houses built in concrete wallsSimone Mesquita Alvares 13 June 2018 (has links)
O atual programa de contenção do déficit habitacional brasileiro, Minha Casa Minha Vida, criado em 2009, apesar de numericamente significativo, apresenta uma série de complicações e inadequações. Um importante exemplo é a inadequação das construções à Zona Bioclimática na qual o projeto é construído. Diante desse fato, o conforto térmico do usuário deixa a desejar pois os ambientes são desconfortáveis e nada sustentáveis do ponto de vista ambiental. Neste contexto, o trabalho teve como objetivo avaliar o desempenho térmico de habitações de interesse social do PMCMV na Zona Bioclimática 4 construídas com paredes de concreto armado moldadas no local, técnica de rápida execução que vem sendo utilizada em larga escala no país; complementarmente, foi analisada a percepção do usuário frente às condições de conforto térmico em um desses residenciais. A avaliação do desempenho térmico das habitações foi feita com base nos regulamentos nacionais NBR 15220 e NBR 15575 em seus procedimentos simplificados; para avaliar a ventilação, via método de visualização de escoamento (mesa dágua) e a insolação, via simulação computacional de horas de sombreamento com auxílio de cartas solares; para a avaliação da percepção do usuário frente ao conforto térmico, foram feitas pesquisas de campo em um dos empreendimentos de habitações sociais na zona em estudo tendo como base os questionários ASHRAE 55 juntamente com coleta de dados climáticos de temperatura e umidade relativa e com levantamento de modificações projetuais. A partir dos dados coletados, pôde-se confirmar objetivamente a inadequação aos limites mínimos estabelecidos pelas normas de desempenho térmico nos parâmetros de vedação vertical e cobertura. Em entrevista com os moradores, as casas foram consideradas desconfortáveis termicamente no inverno e verão. A partir do diagnóstico das alterações nos projetos, nota-se que a maior parte das casas sofrem alterações para maior adequação à vida dos moradores, essas que se tornam responsáveis pelo desconforto térmico. Fica evidente a necessidade do aumento da inércia térmica do sistema construtivo, para futuras casas construídas com o referido sistema além da necessidade de um plano de expansão da moradia que oriente o morador a fazer modificações que não prejudiquem o desempenho térmico do edifício e o conforto térmico dos habitantes. / The current Brazilian low-income housing program, named Minha Casa Minha Vida, was created in 2009 by the Brazilian government and despite being numerically significant, it has many significant issues that affect its quality. One important example is the used construction methods that do not take into account the climate or the bioclimatic zones where the houses are located resulting in energy efficiency, environmental and thermal confirm issues. This work is developed in this context and aims to evaluate the objective and subjective thermal performance of the houses built in the Zone 4 with reinforced concrete walls molded in place, which is a widespread construction technique within the studied program. Thermal performance of the dwellings was analyzed in the light of the Brazilian regulation norm NBR15220 and NBR 15575. Surveys based on ASHRAE 55 norm were conducted to evaluate the user\'s thermal comfort perception and in situ measurements were taken at the studied bioclimatic zone. From the data collected, we conclude that the houses do not meet the norm limits and that they are also subjectively uncomfortable, during summer and winter. As means to increase comfort, we note that all houses dwellers modified their houses making it clear that future houses should have more thermal inertia and that, as the program expands, dwellers should be instructed to not make construction changes that might affect their thermal comfort.
|