Spelling suggestions: "subject:"penetrômetro dde impacto"" "subject:"penetrômetro dee impacto""
1 |
Projeto conceitual de um instrumento para avaliar o estado de compactação do soloMerino Pérez, Mauricio 26 April 2016 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Mecânica, 2016. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-06-24T13:28:21Z
No. of bitstreams: 1
2016_MauricioMerinoPérez.pdf: 5764870 bytes, checksum: 3d0e9b606bf4103d7b82352967b71d2e (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-06-30T19:18:27Z (GMT) No. of bitstreams: 1
2016_MauricioMerinoPérez.pdf: 5764870 bytes, checksum: 3d0e9b606bf4103d7b82352967b71d2e (MD5) / Made available in DSpace on 2016-06-30T19:18:27Z (GMT). No. of bitstreams: 1
2016_MauricioMerinoPérez.pdf: 5764870 bytes, checksum: 3d0e9b606bf4103d7b82352967b71d2e (MD5) / A verificação do estado de compactação é parte fundamental no desenvolvimento e crescimento da produtividade no plantio. O método mais utilizado é a determinação da resistência à penetração por meio do uso de um penetrômetro de impacto. O penetrômetro de impacto é um instrumento de medida dinâmica que tem como princípio de funcionamento a penetração de uma haste através de uma força que provém do impacto de um peso que compõe o equipamento e cai de uma altura constante. A medida realizada torna-se indireta, porque os dados obtidos na medição são levados para uma equação, para assim poder determinar o grau de compactação, isso pode causar incertezas e inexatidão nos dados obtidos. O objetivo desta pesquisa foi a concepção de um novo instrumento de medição de Umidade e Resistência à penetração do solo. Para tanto, utiliza-se um método sistemático para o projeto de produto mecatrônico que emprega o modelo de Integração de Requisitos e a Abordagem ex-ante na fase do Projeto Informacional. A concepção ocorreu a partir das analises das necessidades e restrições dos clientes. Durante a aplicação dos métodos sistemáticos na fase de projeto conceitual, foram utilizadas ferramentas como a DSM para determinar a arquitetura do produto por modularização quando possível. O resultado obtido tem ênfase em componentes e dispositivos necessários para o funcionamento do instrumento e o baixo custo dos mesmos. Constatou-se a eficácia das metodologias adotadas para o desenvolvimento da concepção do instrumento. Os testes funcionais foram determinantes na verificação e avaliação dos módulos que apresentam maior risco para o sucesso da concepção do produto. _______________________________________________________________________________________________ ABSTRACT / The verification of the state of compaction is fundamental in the development and productivity growth in the plantation. The most widely used method is the impact penetrometer developed to determine penetration resistance. The impact penetrometer is a dynamic measuring instrument that operates through the insertion of a rod into the ground .This insertion happens thanks to a resultant force from the impact of a weight in an anvil. This weight is elevated to a certain height and it is dropped freely until it hits the anvil. The measurement made becomes indirectly, because the data obtained in the measurement is taken to an equation, and thus, to determine the state of compaction which can cause uncertainties and inaccuracies in the data obtained. The aim of this research was the conception of a new instrument for measuring moisture and penetration resistance of the soil. For this, it required a systematic approach for Mechatronics product design that uses the model of integration of requirements and the ex-ante approach in the informational phase of the project. The concept of this work came up from the analysis of the needs and restrictions of customers. During the application of systematic methods in the conceptual phase of the project, there were used tools like DSM to determine product architecture by modulation when it was possible. The result obtained has emphasis on components and devices necessary for operation of the instrument and the lower prices of themselves. The effectiveness of the methodologies adopted were proved, for the development of the design of the instrument. Functional tests were decisive in the verification and evaluation of the modules that showed a higher risk for successful product conception.
|
2 |
Comparação entre três penetrômetros na avaliação da resistência mecânica do solo à penetração de um latossolo vermelho eutroférrico / Comparison between three penetrometers in the evaluation of the soil penetration mechanical resistance of a red eutroferric latosolMenezes, Thiago Antonio Villa 02 March 2018 (has links)
Segundo estudo de 2015 da FAO, 33% da área agricultável mundial estão degradados. Um dos principais problemas é a compactação do solo, causada pelo tráfego de máquinas ou animais em solo acima da capacidade de suporte de carga ou fora da condição de trafegabilidade. A compactação do solo desencadeia problemas ambientais e agronômicos como erosão, lixiviação e baixa produtividade. Sua reversão é um processo lento, caro, violento e ineficiente, por isso a melhor saída é previni-la. Para tanto, uma recomendação é mapeá-la regularmente. Um indicador indireto da compactação é a resistência (ou impedância) mecânica do solo à penenetração. O penetrômetro é o instrumento que mede a resistência da introdução de uma haste de ponta cônica no solo; teoricamente, solos mais compactados oferecem maior resistência. Há uma variedade de modelos de penetrômetro no mercado e literatura: bancada ou campo, manual ou automático, estático (penetrógrafo) ou dinâmico (de impacto), com ou sem registro eletrônico de dados etc. Naturalmente, surge a dúvida se é possível comparar dados de penetrômetros diferentes. Alguns trabalhos debruçaram-se sobre essa hipótese, mas a literatura ainda é escassa. Nos poucos artigos publicados, não hão há consenso a respeito da comparabilidade entre penetrômetros diferentes, que ora concordam, ora divergem. No presente trabalho, compararam-se os penetrômetros de campo Sondaterra PI-60 (impacto), Falker PLG1020 (manual) e Falker Solotrack (automático). O experimento observacional foi realizado em um latossolo vermelho eutroférrico de texturas argilosa, argiloarenosa e franco-argiloarenosa em Pirassununga-SP. A resistência mecânica foi avaliada simultaneamente pelos três penetrômetros em oito camadas entre 0,00-0,40 m, abaixo, dentro e acima do intervalo friável do local (10,2-35,1%(v/v)). Sob a mesma condição de umidade do solo, os três penetrômetros concordaram (não houve diferença estatística a 5%) em 58% das observações. Acordaram mais entre si os penetrômetros manual-automático (76%) e impacto-automático (70% das observações). Mesmo onde divergiram, as diferenças mínima, média e máxima de resistência foram respectivamente de 0,61; 0,91 e 1,23 MPa (excluindo-se a camada superficial 0,00-0,05 m), não interferindo no diagnóstico prático da compactação do solo. Em geral, PI-60 > Soltorack > PLG1020 (2,31; 2,14 e 1,91 MPa respectivamente). A compatibilidade entre penetrômetros abaixo, dentro e acima do intervalo friável foi a mesma: 31%, 36% e 33% das observações na mesma ordem. Não houve convergência em apenas três observações (de 120), todas na camada superficial. A resistência variou inversamente com a umidade do solo nos três penetrômetros, concordando com resultados semelhantes na literatura. Em média, a resistência diminuiu de 0,0596 MPa a cada acréscimo de 1% na umidade volumétrica (R2 = 0,44). Concluiu-se que é seguro comparar valores de resistência de penetrômetros diferentes desde que tenham sido coletados sob a mesma condição de umidade do solo. / According to a 2015 FAO study, 33% of the world\'s arable land is degraded. One of the main problems is soil compaction, caused by the traffic of machines or animals on soil over the load bearing capacity or outside of the trafficable condition. Soil compaction triggers environmental and agronomic problems such as erosion, leaching and low productivity. Its reversal is a slow, expensive, violent and inefficient process, so the best way out is to prevent it. To do so, a recommendation is to map it regularly. An indirect indicator of compaction is the mechanical resistance (or impedance) of the soil to penetration. The penetrometer is the instrument that measures the resistance of the introduction of a conical tipped rod into the ground; theoretically, more compacted soils offer greater resistance. There are a variety of penetrometer models in the market and literature: bench or field, manual or automatic, static (penetrograph) or dynamic (impact), with or without electronic data record etc. Of course, the question arises whether it is possible to compare data from different penetrometers. Some papers have dealt with this hypothesis, but the literature is still scarce. In the few articles published, there is no consensus about the comparability between different penetrometers, which now agree, or differ. In the present work, we compared the field sensors Sondaterra PI-60 (manual dynamic), Falker PLG1020 (manual static) and Falker Solotrack (automatic static). The observational experiment was carried out in a red eutroferric latosol (USDA oxisol) of clay, sandy clay and sandy clay loam textures in Pirassununga-SP, Brazil. The mechanical strength was evaluated simultaneously by the three penetrometers in eight layers between 0,00-0,40 m, below, within and above the friable interval of the site (10.2-35.1%(v/v)). Under the same soil moisture condition, the three penetrometers agreed (there was no statistical difference at 5%) in 58% of the observations. Best agreed among themselves the automatic-manual static (76%) and automatic-dynamic (70% of observations) penetrometers. Even where they diverged, the minimum, mean and maximum resistance differences were respectively 0.61; 0.91 and 1.23 MPa (excluding the superficial layer 0.00-0.05 m), values that do not interfere with the practical diagnosis of soil compaction. In general, PI-60 > Solotrack > PLG1020 (2.31, 2.14 and 1.91 MPa respectively). The compatibility between penetrometers below, within and above the friable interval was the same: 31%, 36% and 33% of observations in the same order. There was no convergence in only three observations (of 120), all in the superficial layer. The resistance varied inversely with soil moisture in the three penetrometers, agreeing with similar results in the literature. On average, the resistance decreased by 0.0596 MPa for each increment of 1% in the volumetric humidity (R2 = 0.44). It was concluded that it is safe to compare resistance values from different penetrometers provided they have been collected under the same soil moisture condition.
|
3 |
Comparação entre três penetrômetros na avaliação da resistência mecânica do solo à penetração de um latossolo vermelho eutroférrico / Comparison between three penetrometers in the evaluation of the soil penetration mechanical resistance of a red eutroferric latosolThiago Antonio Villa Menezes 02 March 2018 (has links)
Segundo estudo de 2015 da FAO, 33% da área agricultável mundial estão degradados. Um dos principais problemas é a compactação do solo, causada pelo tráfego de máquinas ou animais em solo acima da capacidade de suporte de carga ou fora da condição de trafegabilidade. A compactação do solo desencadeia problemas ambientais e agronômicos como erosão, lixiviação e baixa produtividade. Sua reversão é um processo lento, caro, violento e ineficiente, por isso a melhor saída é previni-la. Para tanto, uma recomendação é mapeá-la regularmente. Um indicador indireto da compactação é a resistência (ou impedância) mecânica do solo à penenetração. O penetrômetro é o instrumento que mede a resistência da introdução de uma haste de ponta cônica no solo; teoricamente, solos mais compactados oferecem maior resistência. Há uma variedade de modelos de penetrômetro no mercado e literatura: bancada ou campo, manual ou automático, estático (penetrógrafo) ou dinâmico (de impacto), com ou sem registro eletrônico de dados etc. Naturalmente, surge a dúvida se é possível comparar dados de penetrômetros diferentes. Alguns trabalhos debruçaram-se sobre essa hipótese, mas a literatura ainda é escassa. Nos poucos artigos publicados, não hão há consenso a respeito da comparabilidade entre penetrômetros diferentes, que ora concordam, ora divergem. No presente trabalho, compararam-se os penetrômetros de campo Sondaterra PI-60 (impacto), Falker PLG1020 (manual) e Falker Solotrack (automático). O experimento observacional foi realizado em um latossolo vermelho eutroférrico de texturas argilosa, argiloarenosa e franco-argiloarenosa em Pirassununga-SP. A resistência mecânica foi avaliada simultaneamente pelos três penetrômetros em oito camadas entre 0,00-0,40 m, abaixo, dentro e acima do intervalo friável do local (10,2-35,1%(v/v)). Sob a mesma condição de umidade do solo, os três penetrômetros concordaram (não houve diferença estatística a 5%) em 58% das observações. Acordaram mais entre si os penetrômetros manual-automático (76%) e impacto-automático (70% das observações). Mesmo onde divergiram, as diferenças mínima, média e máxima de resistência foram respectivamente de 0,61; 0,91 e 1,23 MPa (excluindo-se a camada superficial 0,00-0,05 m), não interferindo no diagnóstico prático da compactação do solo. Em geral, PI-60 > Soltorack > PLG1020 (2,31; 2,14 e 1,91 MPa respectivamente). A compatibilidade entre penetrômetros abaixo, dentro e acima do intervalo friável foi a mesma: 31%, 36% e 33% das observações na mesma ordem. Não houve convergência em apenas três observações (de 120), todas na camada superficial. A resistência variou inversamente com a umidade do solo nos três penetrômetros, concordando com resultados semelhantes na literatura. Em média, a resistência diminuiu de 0,0596 MPa a cada acréscimo de 1% na umidade volumétrica (R2 = 0,44). Concluiu-se que é seguro comparar valores de resistência de penetrômetros diferentes desde que tenham sido coletados sob a mesma condição de umidade do solo. / According to a 2015 FAO study, 33% of the world\'s arable land is degraded. One of the main problems is soil compaction, caused by the traffic of machines or animals on soil over the load bearing capacity or outside of the trafficable condition. Soil compaction triggers environmental and agronomic problems such as erosion, leaching and low productivity. Its reversal is a slow, expensive, violent and inefficient process, so the best way out is to prevent it. To do so, a recommendation is to map it regularly. An indirect indicator of compaction is the mechanical resistance (or impedance) of the soil to penetration. The penetrometer is the instrument that measures the resistance of the introduction of a conical tipped rod into the ground; theoretically, more compacted soils offer greater resistance. There are a variety of penetrometer models in the market and literature: bench or field, manual or automatic, static (penetrograph) or dynamic (impact), with or without electronic data record etc. Of course, the question arises whether it is possible to compare data from different penetrometers. Some papers have dealt with this hypothesis, but the literature is still scarce. In the few articles published, there is no consensus about the comparability between different penetrometers, which now agree, or differ. In the present work, we compared the field sensors Sondaterra PI-60 (manual dynamic), Falker PLG1020 (manual static) and Falker Solotrack (automatic static). The observational experiment was carried out in a red eutroferric latosol (USDA oxisol) of clay, sandy clay and sandy clay loam textures in Pirassununga-SP, Brazil. The mechanical strength was evaluated simultaneously by the three penetrometers in eight layers between 0,00-0,40 m, below, within and above the friable interval of the site (10.2-35.1%(v/v)). Under the same soil moisture condition, the three penetrometers agreed (there was no statistical difference at 5%) in 58% of the observations. Best agreed among themselves the automatic-manual static (76%) and automatic-dynamic (70% of observations) penetrometers. Even where they diverged, the minimum, mean and maximum resistance differences were respectively 0.61; 0.91 and 1.23 MPa (excluding the superficial layer 0.00-0.05 m), values that do not interfere with the practical diagnosis of soil compaction. In general, PI-60 > Solotrack > PLG1020 (2.31, 2.14 and 1.91 MPa respectively). The compatibility between penetrometers below, within and above the friable interval was the same: 31%, 36% and 33% of observations in the same order. There was no convergence in only three observations (of 120), all in the superficial layer. The resistance varied inversely with soil moisture in the three penetrometers, agreeing with similar results in the literature. On average, the resistance decreased by 0.0596 MPa for each increment of 1% in the volumetric humidity (R2 = 0.44). It was concluded that it is safe to compare resistance values from different penetrometers provided they have been collected under the same soil moisture condition.
|
Page generated in 0.0861 seconds